Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Multiparticle-hole excitations in nuclei near N = Z = 20: $^{41}$K

This experimental study of high-spin structure near the N = Z = 20 region focuses on 41 K and also reports three newly observed γ transitions in 41 Ca from the same reaction. High-spin states were populated using the 26 Mg( 18 O, p2nγ) 41 K and 26 Mg( 18 O, 3nγ) 41 Ca reactions at a beam energy of 50 MeV at the Florida State University John D. Fox Superconducting Linear Accelerator Laboratory, employing the FSU high-purity germanium detector array. The level scheme of 41 K was extended to 12325 keV, possibly up to J π = 25/2 − or 27/2 + , by means of 25 new γ-ray transitions, and that of 41 Ca to 9916 keV. Linear polarization and angular-distribution measurements were used to provide spin and parity information for several states in the 41 K decay scheme. The results are compared with spsdpf cross-shell shell-model calculations using the FSU interaction. Configurations involving zero or one nucleon promoted from the sd to the fp shell reproduce the energies of many known states reasonably well, while multi-particle excitations reveal a more complex interplay of single-particle motion, collective pairing, and deformation, posing an interesting challenge for future theoretical work.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proton branching ratios in 22 Mg for X-ray bursts

Here, decay protons from 22 Mg energy levels populated through a previously reported 24 Mg(p, t) 22 Mg transfer reaction (Chae et al. in Phys Rev C 79:055804, 2009) have been analyzed for proton branching ratios as a follow-up analysis. The measurement was performed at the Holifield Radioactive Ion Beam Facility of Oak Ridge National Laboratory by utilizing 41-MeV proton beams and 24 Mg solid targets. Decay protons and reaction tritons were simultaneously detected with a silicon detector array. By investigating the 24 Mg(p, t) 22 Mg*(p) 21 Na channels, the proton branching ratios of five 22 Mg excited states were obtained. The measured branching ratios provide constraints on the proton partial widths of the populated 22 Mg levels, which have implications for X-ray burst nucleosynthesis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lifetimes of excited states in $^{16}$C as a benchmark for ab initio developments

Lifetimes of higher-lying states ($2_2^+$ and $4_1^+$) in 16 C have been measured, employing the Gammasphere and Microball detector arrays, as key observables to test and refine ab initio calculations based on interactions developed within chiral Effective Field Theory. The presented experimental constraints to these lifetimes of $\tau ({2_2^+}) = [244, 446]\,~\textrm{fs}$ and $\tau ({4_1^+}) = [1.8, 4]\,~\textrm{ps}$, combined with previous results on the lifetime of the $2_1^+$ state of 16 C, provide a rather complete set of key observables to benchmark the theoretical developments. We present No-Core Shell-Model calculations using state-of-the-art chiral 2- (NN) and 3-nucleon (3N) interactions at next-to-next-to-next-to-leading order for both the NN and the 3N contributions and a generalized natural-orbital basis (instead of the conventional harmonic-oscillator single-particle basis) which reproduce, for the first time, the experimental findings remarkably well. The level of agreement of the new calculations as compared to the CD-Bonn meson-exchange NN interaction is notable and presents a critical benchmark for theory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fast neutron background characterization of the future Ricochet experiment at the ILL research nuclear reactor

Abstract The future Ricochet experiment aims at searching for new physics in the electroweak sector by providing a high precision measurement of the Coherent Elastic Neutrino-Nucleus Scattering (CENNS) process down to the sub-100 eV nuclear recoil energy range. The experiment will deploy a kg-scale low-energy-threshold detector array combining Ge and Zn target crystals 8.8 m away from the 58 MW research nuclear reactor core of the Institut Laue Langevin (ILL) in Grenoble, France. Currently, the Ricochet Collaboration is characterizing the backgrounds at its future experimental site in order to optimize the experiment’s shielding design. The most threatening background component, which cannot be actively rejected by particle identification, consists of keV-scale neutron-induced nuclear recoils. These initial fast neutrons are generated by the reactor core and surrounding experiments (reactogenics), and by the cosmic rays producing primary neutrons and muon-induced neutrons in the surrounding materials. In this paper, we present the Ricochet neutron background characterization using $$^3$$ 3 He proportional counters which exhibit a high sensitivity to thermal, epithermal and fast neutrons. We compare these measurements to the Ricochet Geant4 simulations to validate our reactogenic and cosmogenic neutron background estimations. Eventually, we present our estimated neutron background for the future Ricochet experiment and the resulting CENNS detection significance. Our results show that depending on the effectiveness of the muon veto, we expect a total nuclear recoil background rate between 44 ± 3 and 9 ± 2 events/day/kg in the CENNS region of interest, i.e. between 50 eV and 1 keV. We therefore found that the Ricochet experiment should reach a statistical significance of 4.6 to 13.6 $$\sigma $$ σ for the detection of CENNS after one reactor cycle, when only the limiting neutron background is considered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First observation of collective rotational bands in neutron-rich 142 La and the study of octupole/triaxial deformations in 142,143 La

Collective rotational bands were observed for the first time in neutron-rich odd–odd 142 La by means of γ-γ-γ and γ-γ-γ-γ coincidence measurements of prompt fission γ rays from 252 Cf using multi-detector array Gammasphere. Similarity between the yrast band of 142 La and those of neighboring 144 La, 144 Ce was found and interpreted as quasiparticle excitations. Here, PES calculations suggested triaxial deformation for the ground state of 142La. Considerable triaxial and near zero octupole deformations were deduced for the yrast band of 142 La by the TRS model calculations. The band-crossing observed in the yrast band of 142 La was interpreted to be caused by alignment of the (h 11/2 ) 2 proton pair, and the crossing frequency was best reproduced by the TRS calculations taking into account triaxial deformations. In contrast to the interpretations for the band crossing of 142 La, alignments of the (i 13/2 ) 2 neutron pair were found to be responsible for the band-crossing of the yrast band in the neighboring even-N 143 La, and triaxial degree of freedom was found to play a more significant role than octupole deformations in the nucleus, although its β 3 values deduced are large.

142La↗

Chirped-grating spectrometer-on-a-chip

We demonstrate an on-chip spectrometer readily integrable with CMOS electronics. The structure is comprised of a SiO 2 /Si 3 N 4 /SiO 2 waveguide atop a silicon substrate. A transversely chirped grating is fabricated, in a single-step optical lithography process, on a portion of the waveguide to provide angle and wavelength dependent coupling to the guided mode. The spectral and angular information is encoded in the spatial dependence of the grating period. A uniform pitch grating area, separated from the collection area by an unpatterned propagation region, provides the out-coupling to a CMOS detector array. A resolution of 0.3 nm at 633 nm with a spectral coverage tunable across the visible and NIR (to ∼ 1 µm limited by the Si photodetector) by changing the angle of incidence, is demonstrated without the need for any signal processing deconvolution. This on-chip spectrometer concept will cost effectively enable a broad range of applications that are beyond the reach of current integrated spectroscopic technologies.

Nezhadbadeh, Shima↗

Visible (400- to 700-nm) chirped-grating-coupled waveguide spectrometer

An integrable on-chip spectrometer, based on a transversely-chirped-grating waveguide-coupler for the 400- to 700-nm visible spectral range is demonstrated. For a fixed angle of incidence, the coupling wavelength is dependent on the local grating period and the waveguide structure. The transversely-chirped-input grating is fabricated on a SiO 2 -Si 3 N 4 -SiO 2 waveguide atop a Si substrate by interferometric lithography in two sections on a single silicon substrate. A uniform period grating, separated from the input coupler by a propagation region, is provided for out-coupling to a 2048 element CMOS detector array. The incident light with wavelength spanning 400- to 700-nm is coupled into waveguide at 33.5° through the chirped grating coupler. A resolution of ∼ 1.2 nm is demonstrated without any signal processing reconstruction.

Wang, Xuemei↗

Phase Contrast Imaging Diagnostic on DIII-D (1994-2007); Phase Contrast Imaging Diagnostic on DIII-D and Alcator C-Mod (2007-2010); Experimental Study of Waves, Turbulence and Transport, and Model Validation with Phase Contrast Imaging on DIII-D and Alcator C-Mod (2010-2012); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Measuring High-k Turbulence and Alfven modes (2021-2016); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Full Multi-Scale Measurements (2016-2020) (Final Report)

This report describes the first twenty-five years of development and use of the Phase Contrast Imaging (PCI) diagnostic for measuring plasma fluctuations on the DIII–D tokamak. One of the key challenges in moving tokamak technology forward to the stage of a nuclear reactor remains understanding how energy and particles are transported across the magnetic field by the action of turbulence and waves, and PCI provides a highly flexible and capable measurement of these fluctuations. The PCI diagnostic uses a laser beam to probe the plasma and optical filtering to produce an amplitude variation on a linear detector array which provides an image of the density waves in the plasma. The PCI covers an exceptional range in frequency and wavelength of the measured fluctuations, allowing observation of plasma-sized magnetohydrodynamic (MHD) modes and ion- and electron-scale turbulence. Modulation of the beam amplitude allows measurement of radio frequency (RF) waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast Neutron Radiography Simulations

Conclusions: Elements other than detector array can heavily impact performance; Must consider a variety of alterations to an imaging array to determine an optimal system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of TATB by uHPLC-DAD (V.2.2)

The following procedure describes the method for determining the purity of 1,3,5-triamino 2,4,6-trinitrobenzene (TATB) samples using a High-Performance Liquid Chromatography (HPLC) system fitted with a Diode Array Detector (DAD).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of TATB by HPLC-DAD (V.1.4)

The following procedure describes the method for determining the purity of 1,3,5-triamino 2,4,6-trinitrobenzene (TATB) samples using a High-Performance Liquid Chromatography (HPLC) system fitted with a Diode Array Detector (DAD). This procedure is also applicable for the detection of some impurities present in TATB.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identification and Quantification of Photosynthetic Pigments in Algae (Laboratory Analytical Procedure (LAP))

The Laboratory Analytical Procedure (LAP) outlined here describes a method to quantitatively extract phytopigments from microalgae biomass, as well as to identify and quantify individual pigments based on separation and detection with a High-Performance Liquid Chromatography (HPLC) system coupled to a Diode Array Detector (DAD). Pigments were extracted with greater than 95 % extraction efficiency. Chromatographic conditions allowed for isomeric resolution between pigments and identification based on UV/Vis spectra and comparison to analytical standards.

09 BIOMASS FUELS↗

Diagnostics for PSR Upgrade

This report discusses the diagnostics upgrade plan for the PSR. The PSR diagnostics under discussion include beam position and phase monitor (BPPM), wirescanners, wall current monitors, bunch shape monitors, laser notchers, and diamond array detectors. Existing diagnostics at the PSR include beam position monitors (BPM), a wirescanner, and a wall current monitor. All existing diagnostics need modernization, as part of the PSR upgrade plan. Meanwhile, we will introduce minor changes to improve the existing setups, which will enhance the performance and the longevity of the diagnostics equipment and components in the upgraded PSR operation. On the other hand, new, advanced, and available diagnostic technologies at a high technology readiness level (TRL) can also be considered for implementation for the PSR upgrade. In this note, we go through all types of diagnostics, introducing their basic principle, operating status, and plans for the PSR upgrade.

43 PARTICLE ACCELERATORS↗

Constraining Neutron Star Structure with Indirect Nuclear Reaction Studies

There were zero expenditures charged against the DE-SC0019042 account after 31 August 2022, i.e., there were no charges during the reporting period. The remaining graduate student that was supported by DE-SC0019042, Nisha Singh, has been supported by another grant, DE-FG02-88ER40387 (PI: Carl R. Brune), since 1 September 2022. She has continued with the same projects that were supported by DE-SC0019042, the determination of the level density in 28 Si via the 27Al(d; n) 28 Si reaction and development of an Si detector array for measuring charged-particle coincidences with neutrons. She continues to make good progress towards her Ph.D.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Using DAPPER to extract the photon strength function of 58Fe using the inverse Oslo and shape methods

The photon strength function of 58 Fe has been extracted using both the Oslo and Shape methods from particle-γ coincidence data measured using the Detector Array for Photons, Protons, and Exotic Residues, which probes nuclei utilizing (d,p) reactions in inverse kinematics. Four particle-γ coincidence matrices, each constructed with different treatments of the γ-ray energies, are explored in order to observe the impact on the resulting nuclear level density and photon strength. The final photon strength function reported is found to agree well with previous Oslo measurements of other iron isotopes. Systematic uncertainties are included, using different model parameters and their reported errors to perform the Oslo method normalization. The model-independent Shape method is explored and the functional form of the photon strength function obtained is in agreement with the Oslo method results. A low-energy enhancement is not reported for 58 Fe in this work given possible subtraction issues originating from strongly populated states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First Experimental Test of the Ratio Method

The ratio is a new reaction observable suggested to extract accurately structure information on halo nuclei. It corresponds to the ratio of differential cross sections for scattering and breakup, which is predicted to remove the uncertainty related to the reaction dynamics. We present here the first experimental test of the method for the 11 Be + 12 C collision at E Lab = 20A MeV performed at Texas A&M University. Differential cross sections for scattering and inclusive one-neutron breakup have been measured with the new detector array BlueSTEAl. The ratio of cross sections is very smooth and independent of the projectile-target interaction, which demonstrates the validity of the ratio method. We extend our analysis to existing 11 Be + 208 Pb data, confirming that the method works well on any target.

11Be↗

A Novel Dew Point Meter: Application to the Measurement of the Sulfuric Acid Dew Point for Combustion Flue Gas

Accurate knowledge of acid dew point is essential for industrial and applied combustion applications. Sulfur in the fuel or raw materials is converted to sulfur dioxide (SO2) during combustion, and a portion of the SO2 is oxidized to sulfur trioxide (SO3). The SO3 will react to form H2SO4 vapor when in the presence of water vapor. Even with just trace levels of H2SO4 vapor in the gas phase (1-10 ppm), the dew point can reach 100°C and higher. To avoid acid condensation and the resulting corrosion on heat recovery equipment, plant engineers must ensure that surface temperatures are above the acid dew point, but this decreases the efficiency of thermal energy recovery. Thus, there is a trade-off between minimizing equipment corrosion and maximizing thermal energy recovery, and the acid dew point is a key parameter for this optimization. Commercially available acid dew point meters use electric conductivity sensors. These sensors are known to greatly underestimate the dew point due to their low sensitivity. In addition, no validation testing has been reported for these units and they are often expensive. In this work, we analyze the theory of the sulfuric acid condensation and develop a novel dew point meter based on this analysis. The meter consists of a novel optical instrument that is designed to monitor the slightest appearance of condensation on a hydrophobic window surface as the surface temperature of the window is slowly decreased. In this way, an accurate measurement of the dew point is obtained under a wide range of concentrations. The basis of the instrument is that a collimated beam from a diode laser will generate forward scattered light when the beam encounters surface condensate, and a sophisticated array detector is used to sensitively monitor the onset of light scattering. The measurement procedures are established to rapidly find the acid dew point, while minimizing error. Further, to calibrate the dew point meter we developed a calibration system based on a liquid bubbler that can generate a stable gas flow with a known sulfuric acid dew point. Test results show that the dew point meter can accurately measure acid dew point over a wide range. For H2SO4 vapor concentrations as low as 6 ppm the acid dew point is measured with an error of only ~1°C. To demonstrate the versatility of this instrument, the dew point meter was adapted for use with a high-pressure flow cell to allow for measurements of the dew point of flue gas from pressurized oxy-fuel combustion in a 100 kWth pressurized reactor.

Cheng, Mao↗