Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detection.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Casting a wide signal net with future direct dark matter detection experiments

As dark matter (DM) direct detection experiments continue to improve their sensitivity they will inevitably encounter an irreducible background arising from coherent neutrino scattering. This so-called "neutrino floor" may significantly reduce the sensitivity of an experiment to DM-nuclei interactions, particularly if the recoil spectrum of the neutrino background is approximately degenerate with the DM signal. This occurs for the conventionally considered spin-independent (SI) or spin-dependent (SD) interactions. In such case, an increase in the experiment's exposure by multiple orders of magnitude may not yield any significant increase in sensitivity. The typically considered SI and SD interactions, however, do not adequately reflect the whole landscape of the well-motivated DM models, which includes other interactions. Since particle DM has not been detected yet in laboratories, it is essential to understand and maximize the detection capabilities for a broad variety of possible models and signatures. Here, we investigate the impact of the background arising from various neutrino sources on the discovery potential of a DM signal for a large class of viable DM-nucleus interactions and several potential futuristic experimental settings, with different target elements. For some momentum suppressed cross sections, large DM particle masses and heavier targets, we find that there is no suppression of the discovery limits due to neutrino backgrounds. Further, we explicitly demonstrate that inelastic scattering, which could appear in models with multicomponent dark sectors, would help to lift the signal degeneracy associated with the neutrino floor. This research could assist with mapping out the optimal DM detection strategy for the next generation of experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

FIRST DETECTION OF >100 MeV GAMMA-RAYS ASSOCIATED WITH A BEHIND-THE-LIMB SOLAR FLARE

We report the first detection of >100 MeV gamma-rays associated with a behind-the-limb solar flare, which presents a unique opportunity to probe the underlying physics of high-energy flare emission and particle acceleration. On 2013 October 11 a GOES M1.5 class solar flare occurred ∼9.°9 behind the solar limb as observed by STEREO-B. RHESSI observed hard X-ray (HXR) emission above the limb, most likely from the flare loop-top, as the footpoints were occulted. Surprisingly, the Fermi Large Area Telescope (LAT) detected >100 MeV gamma-rays for ∼30 minutes with energies up to 3 GeV. The LAT emission centroid is consistent with the RHESSI HXR source, but its uncertainty does not constrain the source to be located there. The gamma-ray spectra can be adequately described by bremsstrahlung radiation from relativistic electrons having a relatively hard power-law (PL) spectrum with a high-energy exponential cutoff, or by the decay of pions produced by accelerated protons and ions with an isotropic pitch-angle distribution and a PL spectrum with a number index of ∼3.8. We show that high optical depths rule out the gamma-rays originating from the flare site and a high-corona trap model requires very unusual conditions, so a scenario in which some of the particles accelerated by the CME shock travel to the visible side of the Sun to produce the observed gamma-rays may be at work.

79 ASTRONOMY AND ASTROPHYSICS↗

Detection of enhancement in number densities of background galaxies due to magnification by massive galaxy clusters

We present a detection of the enhancement in the number densities of background galaxies induced from lensing magnification and use it to test the Sunyaev-Zel'dovich effect (SZE-) inferred masses in a sample of 19 galaxy clusters with median redshift z similar or equal to 0.42 selected from the South Pole Telescope SPT-SZ survey. These clusters are observed by the Megacam on the Magellan Clay Telescope though gri filters. Two background galaxy populations are selected for this study through their photometric colours; they have median redshifts zmedian similar or equal to 0.9 (low-z background) and z(median) similar or equal to 1.8 (high-z background). Stacking these populations, we detect the magnification bias effect at 3.3 sigma and 1.3 sigma for the low-and high-z backgrounds, respectively. We fit Navarro, Frenk and White models simultaneously to all observed magnification bias profiles to estimate the multiplicative factor. that describes the ratio of the weak lensing mass to the mass inferred from the SZE observable-mass relation. We further quantify systematic uncertainties in. resulting from the photometric noise and bias, the cluster galaxy contamination and the estimations of the background properties. The resulting. for the combined background populations with 1 sigma uncertainties is 0.83 +/- 0.24(stat) +/- 0.074(sys), indicating good consistency between the lensing and the SZE-inferred masses. We use our best-fitting eta to predict the weak lensing shear profiles and compare these predictions with observations, showing agreement between the magnification and shear mass constraints. This work demonstrates the promise of using the magnification as a complementary method to estimate cluster masses in large surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Using Temporal Information from Human Mobility Data to Detect Anchor Points

Spatiotemporal mobility data are available in massive quantities, but large quantities of data typically include fewer variables or data fields. Often, the only available fields are User ID, Longitude, Latitude, Timestamp (ULLT). This raises an important question: how much can we infer about human mobility patterns using only these four fields? With ULLT data, we do not know individuals' socioeconomic status information or when they are visiting their anchor points (AP) or locations (such as homes, places of employment, or schools), and it is a modern challenge to use this data to infer these characteristics. When detecting anchor locations with limited input information, verification and validation (VV) are significant challenges. This paper addresses the problem of identifying individuals' anchor locations using only temporal information from spatiotemporal datasets with limited attributes. Our approach does not explicitly use latitude and longitude during analysis. Locationbased information is only employed in the preprocessing stage to identify periods of movement (trips) and stops (dwelling). Beyond this step, all analysis is based on temporal patterns. In theory, if stops and dwell times could be detected through alternative means, our method could function entirely without location-based input. We demonstrate this methodology on the 2017 National Household Travel Survey (NHTS) data, because it includes a carefully designed and collected time use survey with representative sampling and labeled ground truth. The high-quality survey data allows us to test the accuracy of our methods because NHTS contains intended place labels and agent/user characteristics. We have also applied our validated AP identification algorithm on very large-scale GPS based trajectory data for Patterns-of-Life (PoL) assessment and other applications, but due to space limit that could not be presented here.

McBride, Liz [ORNL] (ORCID:0000000286925869)↗

SU-G-201-03: Automation of High Dose Rate Brachytherapy Quality Assurance: Development of a Radioluminescent Detection System for Simultaneous Detection of Activity, Timing, and Positioning

Purpose: Accuracy of positioning, timing and activity is of critical importance for High Dose Rate (HDR) brachytherapy delivery. Respective measurements via film autoradiography, stop-watches and well chambers can be cumbersome, crude or lack dynamic source evaluation capabilities. To address such limitations, a single device radioluminescent detection system enabling automated real-time quantification of activity, position and timing accuracy is presented and experimentally evaluated. Methods: A radioluminescent sheet was fabricated by mixing Gd?O?S:Tb with PDMS and incorporated into a 3D printed device where it was fixated below a CMOS digital camera. An Ir-192 HDR source (VS2000, VariSource iX) with an effective active length of 5 mm was introduced using a 17-gauge stainless steel needle below the sheet. Pixel intensity values for determining activity were taken from an ROI centered on the source location. A calibration curve relating intensity values to activity was generated and used to evaluate automated activity determination with data gathered over 6 weeks. Positioning measurements were performed by integrating images for an entire delivery and fitting peaks to the resulting profile. Timing measurements were performed by evaluating source location and timestamps from individual images. Results: Average predicted activity error over 6 weeks was .35 ± .5%. The distance between four dwell positions was determined by the automated system to be 1.99 ± .02 cm. The result from autoradiography was 2.00 ± .03 cm. The system achieved a time resolution of 10 msec and determined the dwell time to be 1.01 sec ± .02 sec. Conclusion: The system was able to successfully perform automated detection of activity, positioning and timing concurrently under a single setup. Relative to radiochromic and radiographic film-based autoradiography, which can only provide a static evaluation positioning, optical detection of temporary radiation induced luminescence enables dynamic detection of position enabling automated quantification of timing with millisecond accuracy.

60 APPLIED LIFE SCIENCES↗

Applying shot boundary detection for automated crystal growth analysis during in situ transmission electron microscope experiments

In-situ (scanning) transmission electron microscopy (S/TEM) is being developed for numerous applications in the study of nucleation and growth under electrochemical driving forces. For this type of experiment, one of the key parameters is to identify when nucleation initiates. Typically the process of identifying the moment that crystals begin to form is a manual process requiring the user to perform an observation and respond accordingly (adjust focus, magnification, translate the stage etc.). However, as the speed of the cameras being used to perform these observations increases, the ability of a user to “catch” the important initial stage of nucleation decreases (there is more information that is available in the first few milliseconds of the process). Here we show that video shot boundary detection (SBD) can automatically detect frames where a change in the image occurs. We show that this method can be applied to quickly and accurately identify points of change during crystal growth. This technique allows for automated segmentation of a digital stream for further analysis and the assignment of arbitrary time stamps for the initiation of processes that are independent of the user’s ability to observe and react.

36 MATERIALS SCIENCE↗

The Microbial Detection Array Combined with Random Phi29-Amplification Used as a Diagnostic Tool for Virus Detection in Clinical Samples

A common technique used for sensitive and specific diagnostic virus detection in clinical samples is PCR that can identify one or several viruses in one assay. However, a diagnostic microarray containing probes for all human pathogens could replace hundreds of individual PCR-reactions and remove the need for a clear clinical hypothesis regarding a suspected pathogen. We have established such a diagnostic platform for random amplification and subsequent microarray identification of viral pathogens in clinical samples. We show that Phi29 polymerase-amplification of a diverse set of clinical samples generates enough viral material for successful identification by the Microbial Detection Array, demonstrating the potential of the microarray technique for broad-spectrum pathogen detection. We conclude that this method detects both DNA and RNA virus, present in the same sample, as well as differentiates between different virus subtypes. We propose this assay for diagnostic analysis of viruses in clinical samples.

59 BASIC BIOLOGICAL SCIENCES↗

Wave Detection and Tracking Within a Rotating Detonation Engine Through Object Detection

As the operational time window of experimental rotating detonation engines (RDEs) is expanded and the technology matures toward integration within gas turbines, monitoring techniques must evolve to offer computationally efficient and highly time-resolved diagnostics. In this study, computer vision object detection methodology that seeks to reduce data processing time and calculate wave velocity within drastically reduced time intervals as compared to traditional high-frame-rate RDE images analysis techniques is proposed. The adapted you-only-look-once object detection network is trained to detect individual detonation waves within single down-axis RDE images. The wave location and rotational direction detected within a frame are tracked through a series of high-speed images to calculate the frame-to-frame wave velocity with the time-step resolution of $\mathrm{20 μs}$ across a series of frames. The analysis of the annotation box size and image linearization effects is presented, demonstrating the lowest frame-to-frame velocity total uncertainty of $\mathrm{±3.8\%}$ and the highest classification speed of 9.5 frames per second using linearized images. Linearized images “unwrap” the RDE annulus pixel region to a reduced image size. Here, this new method offers great reductions in data processing times and unsteady detonation behavior insight at intervals more comparable to the timescales of detonation wave interactions via the application of machine learning to experimental RDE data.

33 ADVANCED PROPULSION SYSTEMS↗

Dynamical Classification of Trans-Neptunian Objects Detected by the Dark Energy Survey

The outer solar system contains a large number of small bodies (known as trans-Neptunian objects or TNOs) that exhibit diverse types of dynamical behavior. The classification of bodies in this distant region into dynamical classes—subpopulations that experience similar orbital evolution—aids in our understanding of the structure and formation of the solar system. In this work, we propose an updated dynamical classification scheme for the outer solar system. This approach includes the construction of a new (automated) method for identifying mean motion resonances. We apply this algorithm to the current data set of TNOs observed by the Dark Energy Survey (DES) and present a working classification for all of the DES TNOs detected to date. Our classification scheme yields 1 inner centaur, 19 outer centaurs, 21 scattering disk objects, 47 detached TNOs, 48 securely resonant objects, 7 resonant candidates, and 97 classical belt objects. Among the scattering and detached objects, we detect 8 TNOs with semimajor axes greater than 150 au.

79 ASTRONOMY AND ASTROPHYSICS↗

Interactive Rotated Object Detection for Novel Class Detection in Remotely Sensed Imagery

In this paper we propose IRTR-DETR an Interactive and Real-Time Rotated DEtection TRansformer that extends IRTDETR to predict rotated bounding boxes. IRTR-DETR maintains the Human-In-The-Loop (HIL) workflow of IRTDETR but introduces rotation-aware heads for improved detection of objects with arbitrary orientations. Similarly to IRTDETR IRTR-DETR can be trained with a small labeled sample set in an interactive setting but we show that it can also be pretrained on related but not identical data--such as a building damage dataset--before being applied to tasks like identifying buildings under construction. We demonstrate the efficacy of our approach on the publicly available Tiny-DOTA and xBD dataset as well as two study-cases on proprietary datasets of greenhouses and houses under construction ("waffle homes"). Detecting greenhouses is highly relevant in the context of damage assessment while "waffle homes" aid understanding typical floorplans and building codes in different areas both thereby supporting population modeling emergency response and policy planning. Our method outperforms the state of the art in interactive rotated object detection on the Tiny-DOTA dataset by 5.7 percent and improves upon the non interactive RTDETR by 7.85 to 19.39 percent (depending on the number of provided samples) while maintaining its real-time efficiency.

Burges, Marvin [ORNL] (ORCID:0000000312690769)↗

SimLBR: Learning to Detect Fake Images by Learning to Detect Real Images

The rapid advancement of generative models has made the detection of AI-generated images a critical challenge for both research and society. Recent works have shown that most state-of-the-art fake image detection methods overfit to their training data and catastrophically fail when evaluated on curated hard test sets with strong distribution shifts. In this work, we argue that it is more principled to learn a tight decision boundary around the real image distribution and treat the fake category as a sink class. To this end, we propose SimLBR, a simple and efficient framework for fake image detection with Latent Blending Regularization (LBR). Our method significantly improves cross-generator generalization, achieving up to +24.85% accuracy and +69.62% recall on the challenging Chameleon benchmark. SimLBR is also highly efficient, training orders of magnitude faster than existing approaches. Furthermore, we emphasize the need for reliability-oriented evaluation in fake image detection, introducing risk-adjusted metrics and worst-case estimates to better assess model robustness. All the code and models are availabe at: https://github.com/mvrl/SimLBR

Dhakal, Aayush [Washington University, St. Louis]↗

Indirect detection of radiation sources through direct detection of radiolysis products

A system for indirectly detecting a radiation source by directly detecting radiolytic products. The radiation source emits radiation and the radiation produces the radiolytic products. A fluid is positioned to receive the radiation from the radiation source. When the fluid is irradiated, radiolytic products are produced. By directly detecting the radiolytic products, the radiation source is detected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma and neutron detection modeling in the nuclear detection figure of merit (NDFOM) portal

The Nuclear Detection Figure Of Merit (NDFOM) portal is a database of objects and algorithms for evaluating the performance of radiation detectors to detect nuclear material. This paper describes the algorithms used to model the physics and mathematics of radiation detection. As a first-principles end-to-end analysis system, it starts with the representation of the gamma and neutron spectral fluxes, which are computed with the particle and radiation transport code MCNPX. The gamma spectra emitted by uranium, plutonium, and several other materials of interest are described. The impact of shielding and other intervening material is computed by the method of build-up factors. The interaction of radiation with the detector material is computed by a detector response function approach. The construction of detector response function matrices based on MCNPX simulation runs is described in detail. Neutron fluxes are represented in a three group formulation to treat differences in detector sensitivities to thermal, epithermal, and fast neutrons.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Bimetallic Metal–Organic Framework Fe/Co-MIL-88(NH 2 ) Exhibiting High Peroxidase-like Activity and Its Application in Detection of Extracellular Vesicles

Metal–organic frameworks (MOFs) have many attractive features, including tunable composition, rigid structure, controllable pore size, and large specific surface area, and thus are highly applicable in molecular analysis. Depending on the MOF structure, a high number of un-saturated metal sites can be exposed to catalyze chemical reactions. In the present work, we report that by using both Co(II) and Fe(III) to prepare the MIL-88(NH 2 ) MOF, we can produce the bimetallic MOF that can catalyze the conversion of 3,3', 5,5"-tetramethylbenzidine (TMB) to a color product through reaction with H 2 O 2 at a higher reaction rate than the monometallic Fe-MIL-88(NH 2 ). The Michaelis constants (K m ) of the catalytic reaction for TMB and H 2 O 2 are 3-5 times smaller, and the catalytic constants (k cat ) are 5-10 times higher than those of the horse-radish peroxidase (HRP), supporting ultrahigh peroxidase-like activity. These values are also much more superior to those of the HRP-mimicking MOFs reported previously. Interestingly, the bimetallic MOF can be coupled with glucose oxidase (GOx) to trigger the cascade enzymatic reaction for highly sensitive detection of extracellular vesicles (EVs), a family of important biomarkers. Through conjugation to the aptamer that recognizes the marker protein on EV surface, the MOF can help isolate the EVs from biological matrices, which are subsequently labeled by GOx via antibody recognition. The cascade enzymatic reaction between MOF and GOx enables detection of EVs at a concentration as low as 7.8 × 10 4 particles/ml. Further, the assay can be applied to monitor EV secretion by cultured cells, and also can successfully detect the different EV quantities in the sera samples collected from cancer patients and healthy controls. Overall, we prove that the bimetallic Fe/Co-MIL-88(NH 2 ) MOF, with its high peroxidase-activity and high biocompatibility, is a valuable tool deployable in clinical assays to facility disease diagnosis and prognosis.

36 MATERIALS SCIENCE↗

Renewable Surface Fluorescence Sandwich Immunoassay Biosensor for Rapid Sensitive Botulinum Toxin Detection in an Automated Fluidic Format

A renewable surface biosensor for rapid detection of botulinum toxin is described based on fluidic automation of a fluorescence sandwich immunoassay, using a recombinant fragment of the toxin heavy chain as a structurally valid simulant. Monoclonal antibodies AR4 and RAZ1 bind to separate epitopes of both this fragment and the holotoxin. The AR4 antibody was covalently bound to Sepharose beads and used as the capture antibody. A rotating rod flow cell was used to capture these beads delivered as a suspension by the sequential injection flow system, creating a 3.6 microliter column. After perfusing the bead column with sample and washing away the matrix, the column was perfused with Alexa 647 dye-labeled RAZ1 antibody as the reporter. Optical fibers coupled to the rotating rod flow cell at a 90 degree angle to one another delivered excitation light from a HeNe laser and collected fluorescent emission light for detection. After each measurement, the used sepharose beads are released and replaced with fresh beads. In a rapid screening approach to sample analysis, the toxin simulant was detected to concentrations of 10 pM in less than 20 minutes.

59 BASIC BIOLOGICAL SCIENCES↗

The Indirect Detection of GRBs by Ionospheric Response - Detection of GRB060124A

We report on the independent and indirect detection of GRBs by their ionospheric response (SID-Sudden Ionospheric Disturbance) observed at VLF (Very Low Frequency). Although few such detections have been already reported in the past, the capability of such alternative and indirect investigations of GRBs still remains to be investigated in more details. We present and discuss an example of such VLF/SID detection of the GRB 060124A.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The use of Compton scattering in detecting anomaly in soil-possible use in pyromaterial detection

The Compton scattering is able to determine the signature of land mine detection based on dependency of density anomaly and energy change of scattered photons. In this study, 4.43 MeV gamma of the Am-Be source was used to perform Compton scattering. Two detectors were placed between source with distance of 8 cm and radius of 1.9 cm. Detectors of thallium-doped sodium iodide NaI(TI) was used for detecting gamma ray. There are 9 anomalies used in this simulation. The physical of anomaly is in cylinder form with radius of 10 cm and 8.9 cm height. The anomaly is buried 5 cm deep in the bed soil measured 80 cm radius and 53.5 cm height. Monte Carlo methods indicated the scattering of photons is directly proportional to density of anomalies. The difference between detector response with anomaly and without anomaly namely contrast ratio values are in a linear relationship with density of anomalies. Anomalies of air, wood and water give positive contrast ratio values whereas explosive, sand, concrete, graphite, limestone and polyethylene give negative contrast ratio values. Overall, the contrast ratio values are greater than 2 % for all anomalies. The strong contrast ratios result a good detection capability and distinction between anomalies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗