Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dehumidification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Enhanced cooling tower technology for power plant efficiency increase and operating flexibility

The Final Report describes the results of the work completed during the “Enhanced Cooling Tower Technology for Power Plant Efficiency Increase and Operating Flexibility” project. The objectives of work were to develop and demonstrate the prototype (up to 100 kWth) of an economically viable “all weather” Sub-Dew Point Cooling Tower (SDPCT) with inlet air cooling and dehumidification including testing in laboratory-controlled environment for simulating various ambient conditions. The inlet air is cooled and dehumidified by a Pressure Dehumidifying System (PDHS) installed at the cooling tower inlet.

20 FOSSIL-FUELED POWER PLANTS↗

Opportunities for Catalytic Reactions and Materials in Buildings

Residential and commercial buildings are responsible for over 30% of global final energy consumption and accounts for ~40% of annual direct and indirect greenhouse gas emissions. Energy efficient and sustainable technologies are necessary to not only lower the energy footprint but also lower the environmental burden. Many proven and emerging technologies are being pursued to meet the ever-increasing energy demand. Catalytic science has a significant new role to play in helping address sustainable energy challenges, particularly in buildings, compared to transportation and industrial sectors. Thermally driven heat pumps, dehumidification, cogeneration, thermal energy storage, carbon capture and utilization, emissions suppression, waste-to-energy conversion, and corrosion prevention technologies can tap into the advantages of catalytic science in realizing the full potential of such approaches, quickly, efficiently, and reliably. Catalysts can help increase energy conversion efficiency in building related technologies but must utilize low cost, easily available and easy-to-manufacture materials for large scale deployment. This entry presents a comprehensive overview of the impact of each building technology area on energy demand and environmental burden, state-of-the-art of catalytic solutions, research, and development opportunities for catalysis in building technologies, while identifying requirements, opportunities, and challenges.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extreme Water Uptake of Hygroscopic Hydrogels through Maximized Swelling‐Induced Salt Loading

Abstract Hygroscopic hydrogels are emerging as scalable and low‐cost sorbents for atmospheric water harvesting, dehumidification, passive cooling, and thermal energy storage. However, devices using these materials still exhibit insufficient performance, partly due to the limited water vapor uptake of the hydrogels. Here, the swelling dynamics of hydrogels in aqueous lithiumchloride solutions, the implications on hydrogel salt loading, and the resulting vapor uptake of the synthesized hydrogel–salt composites are characterized. By tuning the salt concentration of the swelling solutions and the cross‐linking properties of the gels, hygroscopic hydrogels with extremely high salt loadings are synthesized, which enable unprecedented water uptakes of 1.79 and 3.86 gg −1 at relative humidity (RH) of 30% and 70%, respectively. At 30% RH, this exceeds previously reported water uptakes of metal–organic frameworks by over 100% and of hydrogels by 15%, bringing the uptake within 93% of the fundamental limit of hygroscopic salts while avoiding leakage problems common in salt solutions. By modeling the salt‐vapor equilibria, the maximum leakage‐free RH is elucidated as a function of hydrogel uptake and swelling ratio. These insights guide the design of hydrogels with exceptional hygroscopicity that enable sorption‐based devices to tackle water scarcity and the global energy crisis.

Graeber, Gustav↗

Influence of the Anions on the Interaction Energy between Water and Ionic Liquids

It is essential to understand the interaction energy between water and ionic liquids (ILs) in search of ILs for dehumidification applications. In this paper, the intermolecular interaction energy between water and 1-ethyl-3-methylimidazolium ([EMIM])-based ILs was investigated. The vapor-liquid equilibrium data were first measured for solutions of [EMIM][BF 4 ], [EMIM][N(CN) 2 ], [EMIM][CF 3 SO 3 ], and [EMIM][CH 3 SO 3 ] with water molar fractions of 8–95 % at temperatures of 303–343 K. The IL-IL and water-IL intermolecular interaction energies were determined by using the correlated non-random two-liquid model. The results revealed that fluorine atoms in anions reduce the attraction energy between IL and water, and thus, decrease the water affinity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Aqueous solution of [EMIM][OAc]: Property formulations for use in air conditioning equipment design

Liquid desiccant air conditioning (LDAC) is a promising alternative to vapor compression refrigeration based space cooling and dehumidification for the reduction of energy consumption and the improvement of indoor air quality. However, its use in the air conditioning market is still very limited due to its high installation cost, intensive carryover, and high cost of operation and maintenance associated to the corrosion of the current desiccant liquids. Substitutes for the traditional desiccant liquids with better properties and no corrosion are highly needed. Ionic liquids, which are salts comprised of organic cations and inorganic anions or organic anions, have high thermal stability, negligible or no vapor pressure, varied solubility in water, low or no corrosion to metals, and low driving temperatures to achieve dew point temperatures. All of those characteristics make them as perfect substitutes for traditional desiccant liquids. Up to date, a very few research groups investigated ILs as potential alternatives to traditional desiccant liquids for LDAC. The study aimed to identify the ionic liquids as ideal desiccant liquids to achieve better cost-effectiveness and higher system performance of LDAC. There were 13 different ionic liquids (IL) identified and screened for the most promising candidate. 1-Ethyl-3-methylimidazolium acetate, [EMIM][OAc], was selected as an ideal candidate for the capable of the most adsorption and desorption. The study was mainly focused on the development of calculation models for the thermo-physical properties of the aqueous solution of [EMIM][OAc] to represent the property data needed for use as the desiccant liquid in sorption-based air conditioning equipment. It aims to provide convenient methods for use in the design and model of the sorption-based air conditioning. Finally, the calculation models for the following thermo-physical properties of the aqueous solution of [EMIM][OAc] were proposed and presented in the study: the vapor pressures, specific heat capacity, density, and dynamic viscosity at various temperatures and concentrations.

1-Ethyl-3-methylimidazolium acetate↗

Performance assessment of radiant cooling system integrated with desiccant assisted DOAS with solar regeneration

The Radiant cooling system integrated with Dedicated Outdoor Air System (DOAS) is a viable substitution for conventional all air system in order to reduce primary energy consumption, as it decouples the cooling and ventilation task. In DOAS major portion of energy is consumed in cooling coil where it dehumidifies the process supply air. This study describes an alternate solution for dehumidification, with the substitution of the desiccant wheel with solar regeneration in place of a chilled water coil based dehumidifier. In this paper, simulations were carried out using EnergyPlus on a reference medium office building to investigate the contribution of solar energy towards the total energy consumption of desiccant assisted DOAS with radiant cooling system. To evaluate the system performance and energy saving potential, desiccant based DOAS is compared with cooling coil assisted DOAS integrated with Radiant cooling system. Simulations were carried out for different solar collector area to evaluate primary energy savings. Results indicate that from 7.4 % to 28.6 % energy saving (according to different collector area) can be achieved due to the solar regeneration in desiccant assisted DOAS, the impact of different solar collector area on potential of energy savings is also described.

42 ENGINEERING↗

Sensitivity of occupant comfort models to humidity and their effect on cooling energy use

Residential building energy consumption in the United States has decreased steadily during the last several decades largely because of advances in building codes as well as voluntary efficiency and labeling programs, which have resulted in the reduction in building sensible loads. Building latent loads have not decreased by the same amount, and field and analytical research studies have concluded that high-efficiency, low-load homes often have elevated indoor humidity levels, possibly leading to occupant discomfort. There are discrepancies in the literature on occupant comfort as it relates to indoor humidity and recommended upper humidity limits. The choice of humidity limit could potentially change results and conclusions on the energy impacts of a new air conditioner or dehumidifier technology, changing ventilation rates, or an improved building envelope. In this study, we use building simulations to explore the impact of humidity control on cooling energy use in efficient residential buildings for different humidity limits. We look at limits based on humidity ratio (or dew point temperature), wet-bulb temperature, relative humidity, and constant slope lines based on the popular comfort models of both Fanger and Gagge. We quantify the additional energy use required to control humidity below these limits. We look at the sensitivity of the results to different temperature and humidity set points, occupant internal gains, moisture buffering levels, evaporator airflow rates, and dehumidifier energy factors. High-efficiency home predicted energy savings are more sensitive to the assumed humidity limit and cooling and dehumidification set points than the other parameters investigated in this paper.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Desalination metamodels and a framework for cross-comparative performance simulations

There is an opportunity to save energy and reduce operational expenses when choosing a suitable desalination method aided by computational modeling. Existing models are not conducive to generalized comparisons between different desalination methods. Therefore, the work in this study developed metamodels for six desalination methods, grouped them into thermal and molecular transport families, and validated their predictive performance within 9% difference from published data. This validated framework allowed comparisons of desalination methods at their prescribed ranges of operational conditions that they were designed for. These conditions specify feed salinity ranges of 1.6 to 2.4 g/kg for Capacitive Deionization and Reverse Osmosis (RO), 2.8 to 4.2 g/kg for Electrodialysis, 28 to 42 g/kg for Thermovapor Compression and Humidification-Dehumidification, and 37 to 55 g/kg for Multi-Effect Distillation (MED). Despite different operational conditions, all models exhibit non-linear, positive correlation between energy consumption and system size in response to feed salinity and production rate. The framework is also employed in a cross-comparative analysis between MED and RO whose results suggest that energy intensity for MED is an order of magnitude greater than RO for the same operational conditions, but actual operational costs are comparable. Overall, the framework is ready for deployment in case studies of actual desalination plants.

42 ENGINEERING↗

Modeling and experimental validation of direct contact crossflow packed beds condenser used in HDH desalination systems

Humidification and dehumidification (HDH) desalination systems are alternatives to reverse osmosis desalination systems, especially for high salinity waters. A HDH system is essentially equipped with a humidifier (also called as evaporator) for air to pick up vapor from saline water, a dehumidifier (also called as condenser) to produce freshwater, and a heating source. HDH systems based on direct contact packed beds heat exchangers have remarkably lower costs than traditional HDH systems due to their inexpensive materials and simple configurations. This paper specifically focuses on direct contact crossflow packed beds condensers, in which cooling water vertically drips through the packed beds, directly contacting the horizontal air-vapor flow. A two-dimensional mathematical model that solves for the enthalpy values of the working fluids is proposed in this paper, and the PDEs are solved using finite differences. To validate the model, an experimental condenser was built and tested. Water temperatures inside the test section at twenty-nine locations were measured, as well as the air vapor temperatures of five locations at the outlet. The measured water and air-vapor temperatures agree with the simulation results with less than 10 % error in most of the compared domain.

42 ENGINEERING↗

Performance study of the cross-flow Maisotsenko cycle in humid climate conditions

This paper presents a first numerical analysis of the cross-flow Maisotsenko cycle (M-Cycle) below dew-point evaporative cooler for humid climates with model including the water vapor condensation phenomenon. Proposed solution allows to cool ambient air below its dew-point temperature, by utilizing cooling energy in air extracted from the building, due to that it can be used as effective pre-cooling solution for traditional systems. Proposed unit has significant advantage over traditional counter and cross-flow units operating in heat recovery mode, hence it is almost insensitive on temperature of exhaust air. This is caused by effective pre-cooling of the exhaust air in its initial part. Operation in humid climates using cold extracted air results in condensation occurrence in the primary air channels, and hence partial dehumidification of the primary airflow (which allows to cool the air before its dew- point temperature). The Maisotsenko cycle exchanger used to recover heat in the air-conditioning system is compared with Maisotsenko exchanger that operates only on the ambient airflow and does not allow to recover heat from the exhaust airflow from a conditioned space. Achieved results showed that M-Cycle below dew-point air cooler can operate more effectively in humid climates than traditional cross-flow Maisotsenko cycle exchanger.

Condensation↗

Calibrated simulation analysis for integration of evaporative cooling and radiant cooling system for different Indian climatic zones

Radiant cooling system (RCS) has proven to be an energy efficient system for meeting a building's cooling requirements. RCS is energy efficient and provides better thermal comfort compared to conventional all-air heating ventilation air conditioning (HVAC) system. To further improve the efficiency of RCS, a parallel evaporative cooling system (cooling tower) is coupled with RCS and analyzed for different climatic condition using calibrated model. A statistical analysis of weather files (based on wet bulb temperature), was used to identify the availability of useful water for cooling tower integration with RCS. A comprehensive simulation feasibility study of the application of cooling tower in RCS was performed for different cities to cover every climatic zones of India. It was found that in summer, the wet bulb temperature (WBT) of different climatic zones, except warm-humid, is suitable for the integration of cooling tower with RCS. An experimental setup was designed and developed for integration of parallel chiller and cooling tower with panel-based RCS for cooling and a dedicated outdoor air system (DOAS) for dehumidification and ventilation. Experiments were conducted for chiller and cooling tower operated RCS in Composite climate of Jaipur, Rajasthan, India. Building Energy Models (BEM) were developed for both the chiller-operated RCS and cooling tower-operated RCS in EnergyPlus and calibrated with the measured data. Using the calibrated models, performance of the system was analyzed for different climatic zones of India. A chiller-operated RCS was considered as a baseline to compare the annual energy saving potential and monthly performance of the cooling tower integrated RCS. Here, in the cooling tower–operated RCS, a total annual savings of 7% in hot and dry climates, 11% in composite climates and 20% in temperate climates was achieved compared to the chiller-operated RCS.

54 ENVIRONMENTAL SCIENCES↗

Material properties of aqueous potassium acetate solutions for use in liquid desiccant air conditioning

We present thermophysical properties of aqueous potassium acetate solutions relevant to their application as a liquid desiccant in air-conditioning systems. Liquid desiccant air conditioners could provide up to 80% energy savings compared to high-efficiency vapor compression air conditioners. However, the commonly used liquid desiccants, particularly chloride salt solutions, are highly corrosive. This precludes the use of metallic components, necessitating specialized plastics and thereby driving up cost, weight, and limiting operational temperature and pressure ranges. Potassium acetate has been identified as a less corrosive alternative, potentially enabling broader material compatibility in LDAC components. In this study we systematically measured and modelled key thermophysical properties of KAc solutions density, vapor pressure, viscosity, specific heat capacity, phase behavior, and diffusion coefficient across a range of concentrations (10 - 70wt%) and temperatures. For instance, KAc exhibits a vapor pressure of 3.1 kPa at 50wt% and 40degrees C, demonstrating dehumidification capability comparable to chloride salts. By providing an extended dataset and associated models, this work advances the understanding needed to design energy-efficient, corrosion mitigating LDAC system.

36 MATERIALS SCIENCE↗

Efficiency analysis of semi-open sorption heat pump systems

Sorption systems traditionally fall into two categories: closed (heat pumps and chillers) and open (dehumidification). Recent work has explored the possibility of semi-open systems, which can perform heat pumping or chilling while utilizing ambient humidity as the working fluid of the cycle, and are still capable of being driven by solar, waste, or combustion heat sources. The efficiencies of closed and open systems are well characterized, and can typically be determined from four temperature s. In this work, the performance potential of semi-open systems is explored by adapting expressions for the efficiency of closed and open systems to the novel semi-open systems. A key new parameter is introduced, which involves five temperatures, since both the ambient dry bulb and ambient dew point are used. Furthermore, this additional temperature is necessary to capture the open absorber performance in terms of both the absorption of humidity and sensible heat transfer with surrounding air.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Additively manufactured multiplexed inertial coalescence filters

Multiphase flows often pose a significant challenge to the efficient and reliable design of thermofluidic systems. This paper describes multiplexed inertial coalescence filters composed of parallel helical pathways, designed to capture fine droplets (<40 µm) through inertial separation while maintaining a low pressure drop (<400 Pa). Filtration efficiencies for 7 µm and 30 µm droplets were characterized for varying flow conditions, with complete capture observed above a threshold flow rate. Models for filtration efficiency and pressure drop were developed and validated against experimental results to allow system design and optimization, enabled by the tunable additive manufacturing approach used to fabricate the filters. Filter quality factor was computed for varying droplet sizes, showcasing exceptional quality factor when compared to state-of-the-art filters documented in the literature. In conclusion, this multiplexed inertial coalescence filtration approach could find use in dehumidification systems, fog harvesting, chemical reactors, and microgravity droplet capture.

3D Printing↗

Experimental investigation of a solar desiccant cooling installation

Desiccant cooling is a technique based on evaporative cooling and air dehumidification using desiccant regenerated by thermal energy. It is particularly interesting when it is driven by waste or solar heat making this technique environmentally friendly. In this paper, an experimental investigation is carried on a desiccant air handling unit powered by vacuum-tube solar collectors. First, the components are studied under various operating conditions. Then overall performance of the installation is evaluated over a day for a moderately humid climate with regeneration solely by solar energy. In these conditions the overall efficiency of the solar installation is 0.55 while the thermodynamic coefficient of performance is 0.45 and the performance indicator based on the electrical consumption is 4.5. Finally, the impact of outside and regeneration conditions on the performance indicators is studied. (author)

14 SOLAR ENERGY↗

Photovoltaic-electrodialysis regeneration method for liquid desiccant cooling system

Liquid desiccant cooling system (LDCS) is an (a novel) air-conditioning system with good energy saving potential. Regenerator is the power centre for LDCS. Currently, the regeneration process is always fuelled by thermal energy. Nevertheless, this regeneration pattern has some disadvantages in that its performance will become poor when the surrounding atmosphere is of high humidity, and the heat provided for regeneration will be unfavourable to the following dehumidification process. To ameliorate that, a new regeneration method is proposed in this paper: a membrane regenerator is employed to regenerate the liquid desiccant in an electrodialysis way; while solar photovoltaic generator is adopted to supply electric power for this process. Analysis has been made about this new regeneration method and the result reveals: this new manner achieves good stability with the immunity against the adverse impact from the outside high humidity; its performance is much higher than that of the thermal regeneration manner while putting aside the low efficiency of the photovoltaic system. Besides, purified water can be obtained in company with the regeneration process. (author)

14 SOLAR ENERGY↗