Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data centers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The National Space Science Data Center: An operational perspective

The National Space Science Data Center (NSSDC) manages over 110,000 data tapes with over 4,000 data sets. The size of the digital archive is approximately 6,000 GBytes and is expected to grow to more than 28,000 GBytes by 1995. The NSSDC is involved in several initiatives to better serve the scientific community and improve the management of current and future data holdings. These initiatives address the need to manage data to ensure ready access by the user and manage the media to ensure continuing accessibility and integrity of the data. An operational view of the NSSDC, outlining current policies and procedures that have been implemented to ensure the effective use of available resources to support service and mission goals, and maintain compliance with prescribed data management directives is presented.

Blitstein, Ronald↗

Data Centers and Digital Assurance Workshop 2 – Prioritizing Digital Assurance Challenges, Session 2

The second session of the TADA (Technical Assistance for Digital Assurance) Data Centers Cohort, held on November 10, 2025, focused on prioritizing digital assurance challenges at the intersection of data centers and the electric grid. Building on the foundational concepts introduced in Workshop 1, this session deepened the application of the Threat–Vulnerability–Consequence (TVC) framework and emphasized the urgency of addressing cybersecurity, supply chain integrity, and operational reliability. Participants explored the growing convergence of digital and physical systems, the expanding attack surface due to global supply chain dependencies, and the implications of AI-driven load behavior. Real-world incidents—including the Volt Typhoon campaign and vulnerabilities in Solarman and Deye platforms—were analyzed to illustrate the risks of unpatched systems, insecure APIs, and inadequate vendor oversight. Key themes included architecture and interface weaknesses, governance gaps, and human and procedural shortcomings. The workshop also examined the evolving regulatory landscape, highlighting new federal mandates around Foreign Entity of Concern (FEOC) compliance and large-load reliability standards. Through interactive exercises, stakeholders ranked and mapped digital assurance risks from their respective perspectives—utilities, operators, and vendors—laying the groundwork for mitigation strategies and shared accountability models to be developed in Workshop 3. Session 2 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Alternative Fuels Data Center

This presentation provides an overview of the Alternative Fuels Data Center for the 2026 Transportation Technologies Annual Merit Review, including project objectives, milestone, approach to developing and maintaining the website, project accomplishments and progress, and collaboration with other national labs and external partners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Guidelines for submitting data to the National Space Science Data Center

The mission of the National Space Science Data Center (NSSDC) is to disseminate space science data for further analysis beyond that provided by the principal investigators (PIs) or team leaders (TLs) and their coworkers. Consequently, the NSSDC is responsible for the acquisition, organization, storage, retrieval, announcement, and distribution of scientific data obtained mainly from satellites and spacecraft. Any scientist may acquired data from the NSSDC and use them in further studies, either alone or in conjunction with data from ground-based or spacecraft experiments. With the responsibility for archiving data is the concomitant responsibility for distributing the documentation necessary to make those data usable. Since the group most knowledgeable about a particular experiment and its data is the PI or TL and his coworkers, and since the NSSDC cannot possibly supply the qualified personnel needed to write this documentation comprehensively, it is the responsibility of the PI or TL to provide the essential documentation. The NSSDC will support this effort by defining what is needed, by reviewing what is provided, and by reproducing and distributing the resulting documentation with the data. For a high-use data set, the NSSDC may publish the documentation as a Data Users Note; for a low-use data set, the NSSDC may distribute a Xerox, microfilm, or microfiche copy of the documentation.

Source record↗

Optically connected memory for disaggregated data centers

Recent advances in integrated photonics enable the implementation of reconfigurable, high-bandwidth, and low energy-per-bit interconnects in next-generation data centers. We propose and evaluate an Optically Connected Memory (OCM) architecture that disaggregates the main memory from the computation nodes in data centers. OCM is based on micro-ring resonators (MRRs), and it does not require any modification to the DRAM memory modules. We calculate energy consumption from real photonic devices and integrate them into a system simulator to evaluate performance. Here, our results show that (1) OCM is capable of interconnecting four DDR4 memory channels to a computing node using two fibers with 1.02 pJ energy-per-bit consumption and (2) OCM performs up to 5.5× faster than a disaggregated memory with 40G PCIe NIC connectors to computing nodes.

97 MATHEMATICS AND COMPUTING↗

LANL HPC Data Center Monitoring (Summer 2022 Talk) [Slides]

HPC Monitoring is tasked with the understanding of everything that happens in the Data Center. They get to that understanding by: collecting logs and metrics, processing data, analyzing data, displaying information, and receiving alerts on events. Their ultimate (and probably unreachable) goal is a holistic view of the Data Center and an understanding of how everything is correlated.

97 MATHEMATICS AND COMPUTING↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Toward higher-radix switches with co-packaged optics for improved network locality in data center and HPC networks [Invited]

In this work, we study the network locality improvements that can be achieved by using co-packaged optics in data center and high-performance computing (HPC) networks. The increased escape bandwidth offered by co-packaged optics can enable switches with speeds of 51.2 Tb/s and beyond. From a network architecture perspective, the key advantages of introducing co-packaged optics at the switch points include the implementation of large-scale topologies of >12,000 end points with 4× higher bisection bandwidth and the reduction of the required number of switches by >40% compared with state-of-the-art approaches. From a network operation perspective, improved network locality and faster operation can be achieved since the higher-radix switches can mitigate the impact of network contention. Placing applications under fewer leaf switches reduces the number of packets that cross the spine switches in a leaf-spine topology. The proposed scheme is evaluated via discrete-event simulations: we initially evaluate the network locality properties of the system by using virtual-machine traces from a production data center, and we subsequently quantify the performance improvements by simulating an all-to-all pattern for a variety of message sizes over a number of nodes. The results suggest that co-packaged optics form a promising solution for keeping up with bandwidth scaling in future networks. The virtual-machine analysis shows that large-scale applications can be placed under up to 50% fewer first-level switches, while the network analysis shows speedups of up to 7.1, which translates to execution time reductions of up to 26% and 42.7% for applications with communication ratios of 0.3 and 0.5, respectively.

99 GENERAL AND MISCELLANEOUS↗

NASA’s Atmospheric Science Data Center’s Approach to a Cloud-Based Model of Ingest, Archival, and Distribution of TEMPO Data: Methods, Challenges, and Best Practices

The National Aeronautics and Space Administration's (NASA) Atmospheric Science Data Center (ASDC) at NASA Langley Research Center in Hampton, VA provides atmospheric science data products and services to the science community, including enhanced search and subsetting capabilities for numerous datasets. The ASDC is the official Distributed Active Archive Center (DAAC) of record for the upcoming Tropospheric Emissions: Monitoring of Pollution (TEMPO) instrument. TEMPO will be situated on a geostationary satellite positioned at a longitude near the center of the conterminous United States and focused on North America, making hourly swaths of its field of regard from east to west. ASDC’s data products are currently hosted locally and services (e.g., spatial and temporal subsetting) are managed on premises. The ASDC is planning to provide TEMPO data and services in the cloud through the Earthdata Search platform. This presentation will discuss the ASDC’s approach to a cloud-based model of ingest, archival, and distribution of TEMPO data. Methods, challenges, best practices, lessons learned, and future plans will be discussed.

Iman Nasif↗

Energy Use in Quantum Data Centers: Scaling the Impact of Computer Architecture, Qubit Performance, Size, and Thermal Parameters

As quantum computers increase in size, the total energy used by a quantum data center, including the cooling, will become a greater concern. The cooling requirements of quantum computers, which operate at temperatures near absolute zero, are determined by computing system parameters, including the number and type of physical qubits, the packaging efficiency of the system, and the split between circuits operating at cryogenic temperatures and those operating at room temperature. When combined with thermal system parameters such as cooling efficiency and cryostat heat transfer, the total energy use can be determined using a first-principles energy model. These models show that cooling of quantum computers differs in two fundamental ways from conventional data centers: (1) the energy required for cooling is much greater than the energy required for computation, and (2) the cooling loads are sensitive to the computational architecture. The temperature requirements for different qubit types can change energy requirements by orders of magnitude. Power use and computational power, as quantified by quantum volume, are analytically correlated. Approaches are identified for minimizing energy use in integrated quantum systems relative to computational power. Furthermore, designing a sustainable quantum computer will require both efficient cooling and system design that minimizes cooling requirements.

97 MATHEMATICS AND COMPUTING↗

Fusion and Fission Energy and Science Directorate and Information Technology Services Directorate HPC Cluster Reduction, Consolidation, and Savings in Data Center Space, Power, and Cooling

This report evaluates the benefits of decommissioning six legacy FFESD purchased HPC clusters and consolidating services and workloads into a new HPC cluster named HELIOS. The findings demonstrate significant reductions in the data center power and cooling requirements, data center footprint, and operational overhead, while simultaneously increasing computational capacity.

97 MATHEMATICS AND COMPUTING↗

Accelerating Nuclear-Integrated Data Centers in the USA: SWOT Analysis, Power-Thermal Management Strategies, and Industrial-Scale Demonstration and Potential Deployment

Driven by the growth in digital services, cloud computing, AI, and manufacturing, data centers face rising energy demands that challenge traditional power sources and cooling efficiency. This study explores using nuclear power to meet these demands, focusing on accelerated reactor technology deployment and highlighting needs such as N+1/N+2 power supplies and integrated power-thermal management. A SWOT analysis addresses grid connectivity, reactors, and site selection, particularly DOE sites. Reactor technology demonstration and deployment could be accelerated by leveraging test facilities such as MARVEL, MAGNET, TED, FAS, DOME, LOTUS, ATR, Energy System Proving Grounds, and upcoming Energy Launch Pads, along with modeling and simulation tools such as RELAP5, MOOSE, VERA, RAVEN, and FORCE. The potential power and thermal management options, including various cooling technologies, waste-heat utilization, and an industrial-scale demonstration plan, aim to accelerate the integration of nuclear power and data centers in the USA, while emphasizing community and stakeholder engagement and synergistic efforts.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

NASA's astrophysics archives at the National Space Science Data Center

NASA maintains an archive facility for Astronomical Science data collected from NASA's missions at the National Space Science Data Center (NSSDC) at Goddard Space Flight Center. This archive was created to insure the science data collected by NASA would be preserved and useable in the future by the science community. Through 25 years of operation there are many lessons learned, from data collection procedures, archive preservation methods, and distribution to the community. This document presents some of these more important lessons, for example: KISS (Keep It Simple, Stupid) in system development. Also addressed are some of the myths of archiving, such as 'scientists always know everything about everything', or 'it cannot possibly be that hard, after all simple data tech's do it'. There are indeed good reasons that a proper archive capability is needed by the astronomical community, the important question is how to use the existing expertise as well as the new innovative ideas to do the best job archiving this valuable science data.

Vansteenberg, M. E.↗