Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cyber Physical Security”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

An Artificially Intelligent Physical Model-Checking Approach to Detect Switching-Related Attacks on Power Systems

Decentralized and hierarchical microgrid control strategies have lain the groundwork for shaping the future smart grid. Such control approaches require the cooperation between microgrid operators in control centers, intelligent microcontrollers, and remote terminal units via secure and reliable communication networks. In order to enhance the security and complement the work of network intrusion detection systems, this paper presents an artificially intelligent physical model-checking that detects tampered-with circuit breaker switching control commands whether, due to a cyber-attack or human error. In this technique, distributed agents, which are monitoring sectionalized areas of a given microgrid, will be trained and continuously adapted to verify that incoming control commands do not violate the physical system operational standards and do not put the microgrid in an insecure state. The potential of this approach has been tested by deploying agents that monitor circuit breakers status commands on a 14-bus IEEE benchmark system. The results showed the accuracy of the proposed framework in characterizing the power system and successfully detecting malicious and/or erroneous control commands.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Literature Review on Modeling Cyber Networks and Evaluating Cyber Risks

The National Infrastructure Simulations and Analysis Center (NISAC) conducted a literature review on modeling cyber networks and evaluating cyber risks. The literature review explores where modeling is used in the cyber regime and ways that consequence and risk are evaluated. The relevant literature clusters in three different spaces: network security, cyber-physical, and mission assurance. In all approaches, some form of modeling is utilized at varying levels of detail, while the ability to understand consequence varies, as do interpretations of risk. This document summarizes the different literature viewpoints and explores their applicability to securing enterprise networks.

97 MATHEMATICS AND COMPUTING↗

Federation of UML models for cyber physical use cases

This method employs the concept of federation, which is defined as the use of existing models that represent aspects of a system in specific domains (such as physical and cyber security domains) and building interfaces to link all of domain models. Federation seeks to build on existing bodies of work. Some examples include the Common Information Models (CIM) maintained by the International Electrotechnical Commission Technical Committee 57 (IEC TC 57) for the electric power industry. Another relevant model is the CIM maintained by the Distributed Management Task Force (DMTF)? this CIM defines a representation of the managed elements in an Information Technology (IT) environment. The power system is an example of a cyber-physical system, where the cyber systems, consisting of computing infrastructure such as networks and devices, play a critical role in the operation of the underlying physical electricity delivery system. Measurements from remote field devices are relayed to control centers through computer networks, and the data is processed to determine suitable control actions. Control decisions are then relayed back to field devices. It has been observed that threat actors may be able to successfully compromise this cyber layer in order to impact power system operation. Therefore, future control center applications must be wary of potentially compromised measurements coming from field devices. In order to ensure the integrity of the field measurements, these applications could make use of compromise indicators from alternate sources of information such as cyber security. Thus, modern control applications may require access to data from sources that are not defined in the local information model. In such cases, software application interfaces will require integration of data objects from cross-domain data models. When incorporating or federating different domains, it is important to have subject matter experts work together, recognizing that not everyone has the same knowledge, responsibilities, focus, or skill set.

Source record↗

Federating Cyber and Physical Models for Event-Driven Situational Awareness

The purpose of this paper is to describe a novel method to improve electric power system monitoring and control software application interoperability. This method employs the concept of federation, which is defined as the use of existing models that represent aspects of a system in specific domains (such as physical and cyber security domains) and building interface to link all of domain models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Two-Stage Optimization Framework for Detecting and Correcting Parameter Cyber-Attacks in Power System State Estimation

One major tool of Energy Management Systems for monitoring the status of the power grid is State Estimation. Since the results of state estimation are used within the energy management system, the security of the state estimation process is most important. The focus research in this area is on detecting False Data Injection attacks on measurements. While this is important, State Estimation also rely on database that are used to describe the relationship between measurements and systems' states. This paper presents a two-stage programming framework to detect and correct attacks in the parameters of the measurement model used by the state estimation process in the Energy Management System. In the first stage, an estimate of the line parameters ratios are obtained. In the second stage, the estimated ratios from stage I are used in a Bi-Level model for obtaining a final estimate of the measurements' model parameters. Hence, the presented framework does not only unify the detection and correction in a single optimization run, but also provide a monitoring scheme for the SE database that is typically considered static. In addition, in the two stages, linear programming framework is preserved. For validation, the IEEE 118 bus system is used for implementation. The results of this paper illustrate the effectiveness of the proposed model for detecting attacks in the database used in the state estimation process.

state estimation, two-stage optimization, cyber-ph↗

Data-driven Cyberattack Detection for Photovoltaic (PV) Systems through Analyzing Micro-PMU Data

With increasing exposure to software-based sensing and control, Photovoltaic (PV) systems are facing higher risks of cyber attacks. Here, to ensure the system stability and minimize potential economic losses, it is imperative to monitor operating states and detect attacks at the early stage. To meet this demand, Micro-Phasor Measurement Units (μPMU) are increasingly popular in monitoring distribution networks. However, due to the relatively low sampling rate, μPMU has not yet been used to detect and classify cyber-attacks in power electronics enabled smart grid. To our knowledge, this is one of the first attempts to use μPMU to detect cyber attacks that degrade the performance of power electronics systems. We propose to apply data-driven methods on micro-PMU data to implement attack detection. We have evaluated data-driven methods, including decision tree (DT), K-nearest neighbor (KNN), support vector machine (SVM), artificial neural network (ANN), long short-term memory (LSTM) and convolutional neural network (CNN). The proposed CNN model achieves the required performances with the highest 99.23% accuracy and 0.9963 F 1 score.

14 SOLAR ENERGY↗

Transformer Health Monitoring via Synchrophasors

Traditional transformer protection schemes such as differential protection operate once the transformer is in a critical state. Proactive means of transformer health evaluation such as Sweep Frequency Response Analysis, can only be performed periodically with the transformer out-of-service. This work presents a framework where the health and structural integrity of transformers is monitored via synchrophasors in real-time. Synchrophasors and subspace estimation techniques are used to build reduced-order models which are then analyzed across multiple domains. A diagnostics algorithm is developed and tested via Matlab simulations. Test results are promising, opening up new prospects in transformer protection research.

cyber-physical security↗

Phasor Measurement Units Optimal Placement and Performance Limits for Fault Localization

Here, the performance limits of faults localization are investigated using synchrophasor data. The focus is on a non-trivial operating regime where the number of Phasor Measurement Unit (PMU) sensors available is insufficient to have full observability of the grid state. Proposed analysis uses the Kullback Leibler (KL) divergence between the distributions corresponding to different fault location hypotheses associated with the observation model. This analysis shows that the most likely locations are concentrated in clusters of buses more tightly connected to the actual fault site akin to graph communities. Consequently, a PMU placement strategy is derived that achieves a near-optimal resolution for localizing faults for a given number of sensors. The problem is also analyzed from the perspective of sampling a graph signal, and how the placement of the PMUs i.e. the spatial sampling pattern and the topological characteristic of the grid affect the ability to successfully localize faults. To highlight the superior performance of presented fault localization and placement algorithms, the proposed strategy is applied to a modified IEEE 34, IEEE-123 bus test cases and to data from a real distribution grid. Additionally, the detection of cyber-physical attacks is also examined where PMU data and relevant Supervisory Control and Data Acquisition (SCADA) network traffic information are compared to determine if a network breach has affected the integrity of the system information and/or operations.

42 ENGINEERING↗

A Trilevel Model for Segmentation of the Power Transmission Grid Cyber Network

Network segmentation of a power grid's communication system can make the grid more resilient to cyberattacks. Here we develop a novel trilevel programming model to optimally segment a grid communication system, taking into account the actions of an information technology (IT) administrator, attacker, and grid operator. The IT administrator is allowed to segment existing networks, and the attacker is given a budget to inflict damage on the grid by attacking the segmented communication system. Finally, the grid operator can redispatch the grid after the attack to minimize damage. The resulting problem is a trilevel interdiction problem that we solve using a branch and bound algorithm for bilevel problems. We demonstrate the benefits of optimal network segmentation through case studies on the 9-bus Western System Coordinating Council (WSCC) system and the 30-bus IEEE system. These examples illustrate that network segmentation can significantly reduce the threat posed by a cyberattacker.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deception-Based Cyber Attacks on Hierarchical Control Systems using Domain-Aware Koopman Learning

Industrial control systems are subject to cyber attacks that produce physical consequences. These attacks can be both hard to detect and protracted. Here, we focus on deception-based sensor bias attacks made against a hierarchical control system where the attacker attempts to be stealthy. We develop a a data-driven, optimization-based attacker model and use the Koopman operator to represent the system dynamics in a domain-aware and computationally efficient manner. Using this model, we compute several different attacks against a high-fidelity commercial building emulator and compare the impacts of those attacks to each other. Finally, we discuss some computational considerations and identify avenues for future research.

koopman operator, Cyber-Physical Security, machine↗

Sensor and Actuator Attacks on Hierarchical Control Systems with Domain-Aware Operator Theory

Cyber-Physical Systems (CPSs) provide opportunities for cyber attacks to have physical impacts. Advanced Persistent Threats (APTs) are a subclass of cyber threats that act stealthily to avoid detection and enable long-term attacks. Here, we build on our past work in APT modelling to combine deception-based sensor bias attacks and direct actuator manipulations in attacks against a hierarchical control system. That past work used the Koopman operator to develop a data-driven, domain-aware, optimization-based attacker model. Using an expansion of this model, we compute several different attacks, including multiple simultaneous attacks, against a high-fidelity commercial building emulator and compare the impacts of those attacks to each other. One next step of interest is to construct a defender system, built on the same modelling approach, designed to detect and mitigate such attacks.

koopman operator, Cyber-Physical Security, machine↗

Perturbation-Based Diagnosis of False Data Injection Attack Using Distributed Energy Resources

Modern smart grid relies on various sensor measurements for its operational control. In a successful false data injection attack, the attacker manipulates the measurements from the grid sensors such that undetected errors are introduced into the estimates of the system parameters leading to catastrophic situations. This paper proposes a novel perturbation based false data injection attack detection mechanism that utilizes inverter based distributed energy resources (DERs) to create low magnitude perturbation signal in the distribution system voltage that is inconsequential to the normal grid operation. Two voltage sensitivity analysis based algorithms are designed to identify the optimal set of DERs that can create the voltage perturbation signal of desired magnitude. An analytical method of voltage sensitivity analysis is used to compute the magnitude of voltage perturbation signal at each node in a computationally efficient manner. Then, a detection mechanism is developed that checks for the presence of the perturbation sequence in each sensor measurement. A sensor measurement is deemed authentic if the voltage perturbation signal is present in the data. In case of sensor malfunction or cyber-attack, the perturbation signal will not be present in the measurement data. Performance of the proposed attack detection mechanism is validated via simulation of the IEEE 69 bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Source Authentication of Distribution Synchrophasors for Cybersecurity of Microgrids

This letter proposes a hybrid approach combining Self-Adaptive Mathematical Morphology (SAMM) and Time-Frequency (TF) techniques to authenticate the source information of Distribution Synchrophasors (DS) within near-range locations. The SAMM can adaptively regulate the synchrophasors variations which are representatives of local environmental characteristics. Subsequently, TF mapping is employed to extract informative signatures from the regulated synchrophasors variation. Finally, Random Forest Classification (RFC) is used to correlate the extracted signatures with the source information based on the derived TF mapping. Experiment results using DS collected at multiple small geographical scales validated the proposed methodology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Cyber-Attack Detection for PV Farms via Time-Frequency Domain Features

The internetworking of grid-connected power electronics converters (PECs) in photovoltaic (PV) farms has inevitably expanded the cyber-attack surfaces. Here this paper presents a comprehensive study on cyber-attack detection and diagnosis for PEC-enabled PV farms via single waveform sensor to distinguish between normal conditions, open-circuit faults, short-circuit faults, and cyber-attacks. To our knowledge, this has not been attempted before. Firstly, we propose frequency-domain magnitude-based residuals to identify short-circuit faults and a time-domain mean current vector-based feature to distinguish open-circuit faults from other threats. These features can fully reflect the specific physical characteristics of PV farms during threat duration. Secondly, unlike micro phasor measurement units (µPMU) and raw electric waveform-based methods, the proposed innovative features can address novel cyber-attacks that are excluded from the training process. Thirdly, an online hardware-in-the-loop (HIL) testbed using the OPAL-RT real-time digital simulator has verified the effectiveness. The monitoring system runs in real-time while using HIL as an operational solar farm and a National Instruments (NI) data acquisition card as the electric waveform sensor at the point of coupling.

42 ENGINEERING↗

Resilient State Recovery Using Prior Measurement Support Information

Resilient state recovery of cyber-physical systems has attracted much research attention due to the unique challenges posed by the tight coupling between communication, computation, and the underlying physics of such systems. By modeling attacks as additive adversary signals to a sparse subset of measurements, this resilient recovery problem can be formulated as an error correction problem. To achieve exact state recovery, most existing results require less than 50% of the measurement nodes to be compromised, which limits the resiliency of the estimators. In this paper, we show that observer resiliency can be further improved by incorporating data-driven prior information. Here, we provide an analytical bridge between the precision of prior information and the resiliency of the estimator. By quantifying the relationship between the estimation error of the weighted ℓ 1 observer and the precision of the support prior, this quantified relationship provides guidance for the estimator’s weight design to achieve optimal resiliency. Several numerical simulations and an application case study are presented to validate the theoretical claims.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Southeastern Power Administration 2008 Annual Report

Dear Secretary Chu: I am pleased to submit Southeastern Power Administration’s (Southeastern’s) fiscal year (FY) 2008 Annual Report for your review. The information included in this document reflects our agency’s programs, accomplishments, operational and financial activities for the 12-month period beginning October 1, 2007 and ending September 30, 2008. Southeastern marketed more than 4.5 billion kilowatt-hours of energy to 491 wholesale customers in ten southeastern states this past year. Revenues from the sale of this power totaled approximately $263 million. Drought conditions persisted in the southeastern region of the United States during FY 2008 placing strains on our natural and financial resources. Power purchases for FY 2008 totaled $91 million. Approximately $44 million of this amount was for replacement power which is paid only during adverse water conditions in order to meet our customers’ contract requirements. With the continued financial assistance and support of our Federal power customers, funding for capitalized equipment purchases and replacements at U.S. Army Corps of Engineers’ (Corps) hydroelectric projects provided much needed repairs and maintenance for these aging facilities. Southeastern’s cyber and physical security programs continued to be reviewed and updated to meet Department of Energy (DOE), Homeland Security, and North American Electric Reliability Corporation (NERC) standards and requirements. In the coming year, Southeastern will continue open communication and cooperation with DOE, the Federal power customers, and the Corps to maximize the benefits of our region’s water resources. Although competing uses of water and the prolonged drought conditions will present another challenging year for our agency, Southeastern’s employees will meet these challenges and continue to provide reliable hydroelectric power to the people in the southeast. Sincerely, Kenneth E.Legg Administrator

Kerr-Philpott System↗