Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CsY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Instrumental and analytic techniques for separating protons from electrons in the cosmic ray flux

Techniques are being investigated to aid in distinguishing between electrons and the large background of interacting protons which simulate electron-induced electromagnetic cascades. For cosmic ray primaries, incident on the HECRE ionization spectrometer, statistical criteria are employed to test the cascade curves with the incident energy and starting point as free parameters. The physical significance of the distribution of apparent cascade starting points is being studied using Monte Carlo 100-GeV protons. The proposed use of a CsI detector module (totally-active and high Z) to further discriminate against protons is described.

Crannell, C. J.↗

Fragmentation cross sections of 2.1-GeV/nucleon C-12 and O-16 ions

Measurement of the total fragmentation cross sections of C-12 and O-16 ions incident in CsI target and tungsten scintillator modules. The analysis described is based on a one-module criterion for determining the location of an interaction. The results are independent of the windows used, provided that corrections are made for interactions simulated by energy loss fluctuations in the individual modules and for Delta Z ? 1 interactions missed because of the use of wide windows. The cross sections obtained are in general agreement with the values obtained in other experiments for various target nuclei.

Cheshire, D. L.↗

Search for gamma ray lines from supernovae and supernova remnants

A gamma ray monitor with a NaI crystal shielded with a cup-shaped CsI cover was contained in the rotating wheel compartment of the OSO-7 spacecraft for measuring the gamma ray spectra from 0.3 to 10 MeV in search for gamma ray lines from a possible remnant in the Gum Nebula and the apparent Type I supernovae in NGC5253. A brief analysis of data yielded no positive indications for X-rays, gamma ray lines, or continuum from these sources.

Chupp, E. L.↗

The UCSD/MIT hard X-ray and low energy gamma ray experiment for HEAO-A

An HEAO-A spacecraft is described which is scheduled for launch in April 1977 to survey the sky in the 0.15 keV to 10 MeV range of X-rays with improved sensitivity and angular resolution. The spectral and time variations of discrete sources, and the spectrum and isotropy of the diffuse component will be measured. A hard X-ray and low energy gamma ray experiment is described which will use as an array of seven (NaI)(Tl)/CsI(Na) phoswich detectors and eight large CsI(Na) shields. Detector events are pulse-height analyzed with a selectable time resolution of 0.1, 0.005, or 0.00002 sec. The instrument background is expected to be comprised of approximately equal parts of diffuse gamma rays entering the aperture, radioactive decay of spallation products, and gamma ray leakage through the shields. Detailed background predictions are presented, and sensitivity estimates indicate that the Crab nebula should be detected up to approximately 5 MeV. Approximate 1% isotropy limits for the diffuse component of cosmic gamma rays should be achieved, and its spectrum measured with improved precision.

Matteson, J. L.↗

High pressure far infrared spectroscopy of ionic solids

A high-pressure far-infrared cell operating at up to truly hydrostatic pressures of 8 kbar is described and used to determine the anharmonic self-energies associated with the transverse optic modes of ionic solids in which q approximately equals zero. The cell allows far-infrared studies in the spectral range below 120 reciprocal cm. The transverse optic modes were investigated to determine their mode Gruneisen constants and the pressure dependence of their inverse lifetimes in RbI, CsI, and TlCl.

Lowndes, R. P.↗

Spectroscopic determination of electrical conductivity in an MHD duct from absolute intensity measurements

Measurements of the electrical conductivity in the NASA Lewis cesium seeded, H2-O2 MHD duct have been previously reported. In order to corroborate the above measurements and to analyze the possibility of nonuniform seed injection as a cause of the deviations, a spectroscopic investigation of the plasma conductivity has been undertaken. Transverse profiles of the absolute integrated intensity were measured from the optically thin lines of CSI-.5664 microns and .5636 microns. Radial profiles of emission coefficient were obtained from the measured transverse profiles of intensity by Abel inversion. Radial profiles of electrical conductivity were then obtained under two different assumptions. In the first, the Cs seed fraction is assumed uniform and equal to the measured flow rate at the time when the temperature and conductivity were obtained. In the second method, the local temperature and pressure are taken to be those given by a one-dimensional channel calculation including heat transfer and friction. In this case profiles of conductivity and seed fractions are obtained. The results of the two methods are compared to the previously measured conductivity.

Wang, S. Y.↗

A balloon-borne Ge/Li/ spectrometer for gamma-ray astronomy

On June 10, 1974, a new high-resolution gamma ray spectrometer operating in the energy range of 0.05 to 10 MeV was successfully balloon-flight tested. This system uses four 40 cu cm Ge(Li) crystals in a single cryostat as prime sensors. A 6.35 cm thick CsI (Na) shield provides background rejection and collimation, defining a solid angle of 0.095 sr. Cooling is provided by a liquid-nitrogen dewar. The system was highly stable with spectral resolution of better than 2.5 keV at 1 MeV for the flight duration. The background total count rate was about 20 counts/sec. Numerous lines were observed, most of which originated from secondary neutron interactions in the spectrometer. The sensitivity of the system to line emissions originating in cosmic point sources is 0.0001 to 0.001 photons per sq cm s over the energy range.

Jacobson, A. S.↗

Fragmentation cross-section of relativistic oxygen ions and determination of overlap parameter

Results are presented for measurements of total fragmentation cross sections of relativistic O-16 ions in CsI crystals, which were performed using a monochromatic bevatron ion beam at energies of 0.5 and 2.1 GeV/nucleon. The total fragmentation cross section at each energy is determined on the basis of detected changes in the charge of the incident ions, and the values obtained at both energies are found to be the same to within the experimental errors. Values of the O-16 nucleon radius and overlap parameter are derived simultaneously from the measured cross sections.

Verma, S. D.↗

Temperature distributions of a cesium-seeded hydrogen-oxygen supersonic free jet

The hydrogen-oxygen plasma was generated at combustion chamber pressures ranging from 0.5 to 2.0 megapascals and for various seed ratios (1 to 10 percent). The plasma was observed as the atmospheric exhaust from a Mach 2 rocket test facility. Transverse profiles of the absolute integrated intensity were measured with the optically thin CsI lines (0.5664 and 0.5636 microns) at a range of axial positions downstream of the 5-cm-diameter combustor nozzle exit. Radial profiles of the emission coefficient were obtained from the measured transverse profiles of intensity by Abel inversion. Temperatures were then determined from the emission coefficients for conditions of local thermodynamic equilibrium using particle densities generated by a two-dimensional free jet computer program. Temperature results show the inherent effects of compression and expansion pressure waves characteristic of a free jet exiting from a supersonic nozzle.

Wang, S. Y.↗

Determination of boron and lithium by recording the products from (n, alpha) reactions

Irradiation with thermal neutrons in the VVR-S reactor provides a nondestructive method for determining the presence of boron and lithium in solids. The charged particles produced in the reactions Li-6(n,alpha)H-3 and B-10(n,alpha)Li-7 were detected using CsI single crystal. For alpha-particle spectrometry in the boron determination, an ionization chamber (W and Sn electrodes, 99% Ar + 1% H2) was developed allowing both absolute and relative measurements. In determining boron in lithium-containing samples, both scintillation and ionization chambers are used. In determining lithium in minerals, the error was 1.5%, and the sensitivity 0.00005 wt.%. In the determination of boron in SiC with a concentration of boron approximately (3 plus or minus 2) the error given by the alpha-range uncertainty was 15%.

Lobanov, Y. M.↗

Background of a shielded Ge(Li) spectrometer at balloon altitudes

The background data obtained from an actively shielded Ge(Li) spectrometer flown on a balloon were analyzed and a preliminary model was developed to explain background features including the intensity and time profile of line emission. These features can be explained by a combination of secondary radiation originating in the CsI shield and atmospheric secondary radiation leaking through it.

Mahoney, W. A.↗

The ISEE-C gamma ray burst spectrometer

The technical properties, operation, and expected sensitivity are discussed for an experiment intended to search for narrow lines in the spectra of gamma ray bursts during the ISEE-C mission. At the heart of the experiment is a radiatively cooled germanium solid state photon detector. The instrumentation is capable of storing the entire spectrum of all but the largest bursts in the energy range 0.05-6.5 MeV. In addition, it analyzes the signals from two CsI detectors in two other experiments on the spacecraft and records event time histories from these to a few millisecond accuracy. A background mode permits spectral analysis during quiet times and will allow the determination of physically interesting upper limits for narrow lines in the diffuse gamma ray background radiation.

Teegarden, B. J.↗

The UCSD/MIT hard X-ray and low energy gamma-ray experiment for HEAO-1 - Design and early results

Primary scientific objectives of the experiment are the measurement of the spectra and time variations of discrete sources and the spectrum and isotropy of the diffuse background, all in the 10 keV to 10 MeV energy range. The instrument consists of an array of 7 NaI(Tl)/CsI(Na) phoswich-type detectors and 8 large CsI(Na) shields. In order to achieve the maximum sensitivity allowed by weight, data rate and funding constraints of the mission, three detector and aperture geometries were selected. The instrument's total sensitive area is 494 sq cm. The fields of view vary from 1.7 deg x 20 deg FWHM at low energies to 43 deg FWHM at high energies. The basic instrument concepts, details of the mechanical and electrical design, and pre-launch calibrations are presented. In-orbit performance is described and background measurements are analyzed and used to estimate the experiment's ultimate sensitivity.

Matteson, J. L.↗

The hard X-ray burst spectrometer on the solar maximum mission

The primary scientific objective of the spectrometer is to provide a greater understanding of the role of energetic electrons in solar flares. This will be achieved by observations of high energy X-rays in the energy range from 20 to 200 keV with time resolution of 0.128s on a continuous basis and as short as 1 ms for limited intervals. The X-ray detector is an actively shielded CsI(Na) crystal with a thickness of 0.635 cm and a sensitive area of 71 sq cm. In the first year after launch, it is expected that approximately 1000 flares above the sensitivity threshold of 0.2 photons/(sq cm s) lasting for one second, will be detected.

Orwig, L. E.↗

Two-dimensional ultraviolet imagery with a microchannel-plate/resistive-anode detector

An imaging ultraviolet detector has been designed for use with a precision pointed telescope flown on a sounding rocket. Resolution of better than 80 microns over a field of 5 mm has been achieved. The ultraviolet image is converted to electrons at the front surface of a CsI coated chevron microchannel-plate electron multiplier. For each photoelectron, the multiplier produces a burst of about 3,000,000 electrons, which impinges on a tellurium-coated resistive anode with four evaporated hyperbolic readout electrodes. The sizes of the four resulting output pulses are digitized to 10 bit accuracy and telemetered to the ground, where they are divided in pairs to give the x and y coordinates of the photoelectron event. The coordinates are used to generate a picture in real time, and are recorded for computer processing later. The detector was successfully flown in December 1978. Good images of Jupiter and Capella in hydrogen Lyman alpha emission were obtained.

Opal, C. B.↗

Evaluation of high specific-heat ceramic for regenerator use at temperatures between 2-30 K

Specific heat, thermal conductivity (both in the range 2-30 K), and microhardness data were measured on the ceramics labelled LS-8, LS-8A, and LS-8A doped with CsI, SnCl2, and AgCl. A work hardened sample of LS-8A was also studied in an effort to determine the feasibility of using these types of LS-8 materials to replace Pb spheres in the regenerator of the JPL cryocooler. The LS-8A materials are all more than an order of magnitude harder than Pb, and the dopants do not significantly improve the hardness. However, the SnCl2 dopant has a remarkable effect in improving the specific heat and thermal conductivity of LS-8A. The SnCl2 doping level which maximized the regenerator enthalpy change in going from an unloaded to a loaded condition was found to be 0.2 percent SnCl2 in LS-8A. It was also found that the enthalpy change for a regenerator employing the LS-8A material is more than three times larger than for the Pb spheres case. The use of rods, rather than spheres, of optimally doped LS-8A in regenerators is discussed.

Lawless, W. N.↗

Space Telescope digicon technology

The objective of this program was to develop the technology and construct a number of tubes conforming to the chosen configuration. A total of ten starts were made and ten tubes went through to test. Of the ten tubes three were CsI on LiF, six were CsTe on MgF2 and one was KNaCsSb on SiO2. All three faceplate crystals sealed successfully using indium as the sealant. In addition, a number of test seals were made and two photocathode sample runs were made. The tasks E-field, faceplate, anti-corona and electron optical analysis were actively pursued and the results integrated into the BASD HRS project.

Alting-Mees, H. R.↗

Design and performance of the solar maximum mission Hard X-ray Burst Spectrometer

The Hard X-ray Burst Spectrometer acquires data on the temporal and energy distribution of solar X-rays in the energy region from 25 to 385 keV. The detector system is a CsI(Na) central detector, and an anti-coincidence shield with photomultiplier tubes optically coupled to the central and shield crystals. Additional detectors are included for calibration and South Atlantic Anomaly monitoring. A 15 channel pulse height analysis is performed over the energy range every 128 milliseconds. This instrument is capable of handling event rates up to 500 kHz and provides high rate data up to 100 kHz with low spectral distortion. Nine accumulated rates are telemetered every 8.192 seconds. A unique feature of the instrument is the ability to sample rates from the central detector or shield with a one millisecond minimum time resolution. Such samples are stored in a 32768 sample memory with a 40 percent pretrigger event history and a 60 percent posttrigger history.

Workman, L. G.↗