BICEP Array: 150 GHz Detector Module Development

The Background Imaging of Cosmic Extragalactic Polarization (BICEP)/Keck (BK) collaboration is currently leading the quest for the highest-sensitivity measurements of the polarized cosmic microwave background (CMB) anisotropies on a degree scale with a series of cryogenic telescopes, of which BICEP Array (BA) is the latest Stage-3 upgrade with a total of ~ 32,000 detectors. The instrument comprises 4 receivers spanning 30–270 GHz, with the low-frequency 30/40 GHz deployed to the South Pole Station in late 2019. The full complement of receivers is forecast to set the most stringent constraints on the tensor-to-scalar ratio r. Building on these advances, the overarching small-aperture telescope concept is already being used as the reference for further Stage-4 experiment design. This paper describes the development of the BICEP Array 150 GHz detector module and its fabrication requirements, with highlights on the high-density time division multiplexing (TDM) design of the cryogenic circuit boards. The low-impedance wiring required between the detectors and the frst stage of superconducting quantum interference device amplifers is crucial to maintaining a stable bias current on the detectors. Here, a novel multilayer FR4 Printed Circuit Board with superconducting traces, capable of reading out up to 648 detectors, is detailed along with its validation tests. An ultra-high-density TDM detector module concept we developed for a CMB-S4-like experiment that allows up to 1920 detectors to be read out is also presented. TDM has been chosen as the detector readout technology for the Cosmic Microwave Background Stage-4 (CMB-S4) experiment based on its proven low-noise performance, predictable costs, and overall maturity of the architecture. The heritage for TDM is rooted in mm- and sub-mm-wave experiments dating back 20 years and has since evolved to support a multiplexing factor of 64x in Stage-3 experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimization of a single module of CUPID

CUPID is the next generation experiment which will use scintillating cryogenic calorimeters to search for the neutrinoless double β decay. This unobserved process would shed light on the nature of the neutrino, which up to our knowledge could be a Majorana or a Dirac particle, and would give us an important hint to explain the lack of antimatter in the universe. This ambitious search needs a detector with unique characteristics such as an extremely low background level and an excellent energy resolution. CUPID is now in advanced R&D state to optimize the detector design in order to completely exploit the potentialities of scintillating cryogenic calorimeters. In the following I will describe the test performed at the LNGS (Laboratori Nazionali del Gran Sasso) of a single module of the future CUPID detector. In this contribution we present the performance obtained with a novel assembly concept, proving that it matches the requirements for CUPID.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Crosstalk Effects in Microwave SQUID Multiplexed TES Bolometer Readout

Transition-edge sensor (TES) bolometers are broadly used for background-limited astrophysical measurements from the far-infrared to mm-waves. Many planned future instruments require increasingly large detector arrays, but their scalability is limited by their cryogenic readout electronics. Microwave SQUID multiplexing offers a highly capable scaling solution through the use of inherently broadband circuitry, enabling readout of hundreds to thousands of channels per microwave line. As with any multiplexing technique, the channelization mechanism gives rise to electrical crosstalk which must be understood and controlled so as to not degrade the instrument sensitivity. Here, in this study, we explore implications relevant for TES bolometer array applications, focusing in particular on upcoming mm-wave observatories such as the Simons Observatory and AliCPT. We model the relative contributions of the various underlying crosstalk mechanisms, evaluate the difference between fixed-tone and tone-tracking readout systems, and discuss ways in which crosstalk nonlinearity will complicate on-sky measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CMB-S4 Instrument Modeling and Development for CMB-S4

During this thirteen month award, we focused on two main tasks relevant to the development of the CMB-S4 project: (1) The refinement of sensitivity models and use of those to optimize the instrument design, and (2) the final development and testing a cryogenic blackbody calibrator prototype, of which we then produced three copies for CMB-S4's detector testing systems at FNAL, SLAC and UIUC.

47 OTHER INSTRUMENTATION↗

Demonstration of a 1820 channel multiplexer for transition-edge sensor bolometers

The scalability of most transition-edge sensor arrays is limited by the multiplexing technology, which combines their signals over a reduced number of wires and amplifiers. Here, in this Letter, we present and demonstrate a multiplexer design optimized for transition-edge sensor bolometers with 1820 sensors per readout unit, a factor of two more than the previous state-of-the-art. The design is optimized for cosmic microwave background imaging applications, and it builds on previous microwave superconducting quantum interference device multiplexers by doubling the available readout bandwidth to the full 4–8 GHz octave. Evaluating the key performance metrics of yield, sensitivity, and crosstalk through laboratory testing, we find an end-to-end operable detector yield of 78%, a typical nearest-neighbor crosstalk amplitude of ∼0.4%, and a median white noise level of 83 pA/$\sqrt{\textrm{Hz}}$ due to the multiplexer, corresponding to an estimated contribution of 4% to the total system noise for a ground-based cosmic microwave background telescope. Additionally, we identify a possible path toward reducing resonator loss for future designs with reduced noise. We expect these developments to alleviate the system complexity, cryogenic requirements, and cost of future large arrays of low temperature detectors.

cosmic microwave background↗

High-energy X-ray imaging with a Germanium MM-PAD hybrid pixel detector

Germanium is a high-Z sensor material with excellent energy resolution and attractive properties for high-energy photon detection. Despite its advantages, the need for cryogenic operation and challenges in the fabrication of pixelated high-purity germanium have hindered the development of segmented detectors. We report on the fabrication and performance of a germanium imaging detector with 150 μm pixel pitch hybridized to the MM-PAD ASIC. The detector was capable of high-resolution radiographic imaging and has a fast temporal response. Additionally, we describe the detector's upper operating temperature limits using both the MM-PAD and MARS ASICs, achieving stable operation up to 130 K and 190 K, respectively.

36 MATERIALS SCIENCE↗

Characterization and QC practice of 16-channel ADC ASIC at cryogenic temperature for Liquid Argon TPC front-end readout electronics system in DUNE experiment

ColdADC is a low-noise 16-channel analog-to-digital converter ASIC designed for cold readout electronics of Liquid Argon Time Projection Chambers (LArTPCs) in the Deep Underground Neutrino Experiment (DUNE). ColdADC was specifically designed for operation at cryogenic temperatures (77 K–89 K). Cold electronics is considered to be an enabling technology for liquid argon detectors in neutrino experiments. The main function of the chip is to digitize signals from the 16-channel charge-sensitive amplifier designed at BNL (LArASIC) and send digitized signals to the data aggregator and serializer chip (COLDATA). ColdADC operates with a resolution of 12 bits and a sampling rate of 2 MS/s per channel. A complete characterization of prototype chips was conducted at cryogenic temperature, involving power consumption, noise and linearity performance. In the first DUNE Far-Detector module, 384000 data channels will be read out, corresponding to 24000 ColdADC chips. Therefore, systematic testing of ColdADC chips at cryogenic temperature is vital for the quality and reliability of DUNE Single-Phase modules. We have developed a Quality Control (QC) test stand that includes ColdADC evaluation and characterization at cryogenic temperature. The QC procedure was applied to a first batch of 33 chips, corresponding to 528 data channels. The obtained results meet all the required DUNE specifications for ColdADC. Moreover, the testing outcome allowed us to identify possibilities of performance optimization that are currently being addressed in the design of the next version of the chip. The Quality Control procedure is proved to be successful and will be a reference design for future large-batch production testing of final ColdADC ASICs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonequilibrium dynamics of two-level systems directly after cryogenic alternating bias

Two-level systems (TLSs) are a dominant decoherence mechanism in superconducting qubits, microwave kinetic inductance detectors, and quantum dots. TLSs are tunneling states commonly found in amorphous materials and interfaces, which interact electromechanically, leading to energy loss. Fluctuations in the frequency of the TLSs are a significant problem for qubit operation and force recalibration every few hours. In this study, we probe the effect of alternating bias at cryogenic temperatures on TLSs in a purpose-built LC oscillator. When an in situ alternating bias is applied, the steady-state spectra of the TLSs disappear. Spectroscopy reveals transient behavior, in which the TLS frequency fluctuates on the order of minutes. Thermal cycling above 10 K reverses these effects, restoring the TLS spectrum to its original state. Importantly, the intrinsic loss tangent of the LC oscillator remains unchanged before and after the application of the alternating bias. We propose that the disappearance of the steady-state spectrum is caused by nonequilibrium energy buildup from strain in the oxide film introduced by the pulsed voltage-bias sequence. Understanding this nonequilibrium energy could shed light on TLS fluctuations and reduce the calibration requirements for qubits.

general physics↗

Development of an MKID frequency-to-pixel LED mapper for SPT-3G+

SPT-3G+ is the next-generation camera for the South Pole Telescope (SPT). SPT is designed to measure the cosmic microwave background (CMB) and the mm/sub-mm sky. The planned focal plane consists of 34,000 microwave kinetic inductance detectors (MKIDs), divided among three observing bands centered at 220, 285, and 345 GHz. Each readout line is designed to measure 800 MKIDs over a 500 MHz bandwidth, which places stringent constraints on the accuracy of the frequency placement required to limit resonator collisions that reduce the overall detector yield. To meet this constraint, we are developing a two-step process that first optically maps the resonance to a physical pixel location, and then next trims the interdigitated capacitor (IDC) to adjust the resonator frequency. We present a cryogenic LED apparatus operable at 300 mK for the optical illumination of SPT-3G+ detector arrays. We demonstrate integration of the LED controls with the GHz readout electronics (RF-ICE) to take data on an array of prototype SPT-3G+ detectors. We show that this technique is useful for characterizing defects in the resonator frequency across the detector array and will allow for improvements in the detector yield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of correlated charge noise in superconducting qubits at an underground facility

The charge environment of superconducting qubits may be studied through the introduction of controlled, quantified amounts of ionizing radiation. We measure space- and time-correlated charge jumps on a four-qubit device, operating 107 meters below the Earth’s surface in a low-radiation, cryogenic facility designed for the characterization of low-threshold particle detectors. The rock overburden of this facility reduces the cosmic ray muon flux by over 99% compared to laboratories at sea level. Combined with 4π coverage of a movable lead shield, this facility enables quantifiable control over the flux of ionizing radiation on the qubit device. Long-time-series charge tomography measurements on these weakly charge-sensitive qubits capture discontinuous jumps in the induced charge on the qubit islands, corresponding to the interaction of ionizing radiation with the qubit substrate. The rate of these charge jumps scales with the flux of ionizing radiation on the qubit package, as characterized by a series of independent measurements on another energy-resolving detector operating simultaneously in the same cryostat with the qubits. Using lead shielding, we achieve a minimum charge jump rate of $0.19^{+0.04}_{-0.03}$ mHz, almost an order of magnitude lower than that measured in surface tests, but a factor of roughly seven higher than expected based on reduction of ambient gammas alone. We operate four qubits for over 22 consecutive hours with zero correlated charge jumps at length scales above three millimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The DUNE Photon Detection System

DUNE is an underground neutrino oscillation experiment that will be performing precision measurements of the PMNS matrix to determine unambiguously the mass ordering and the leptonic CP violation. It also comprises a rich non-accelerator physics program for the detection of supernova neutrinos, nucleon decay, and BSM physics. DUNE employs a high-power neutrino beam under construction at Fermilab together with the DUNE Near Detector, and four liquid argon TPCs (Far Detector) that will be installed at the Sanford Underground Research Facility in South Dakota, 1300 km away from the neutrino source. The photon detection system (PDS) – which records the 128 nm scintillation light of argon and provides the time of interaction of the beam neutrinos in the Far Detector - is critical for studying nucleon decay and detecting Supernova Neutrino Bursts. The PDS also complements the calorimetric measurement performed by the TPC (i.e. the charge readout) and contributes to the energy calibration and time performance of the Far Detector. The article is an overview of the design of the PDS for the first DUNE far detector module, with special emphasis on VUV light trapping in a cryogenic environment, its technical challenges, and the expected physics performance. The status of the construction of the PDS and its validation in the Run II of ProtoDUNE-SP will be also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Nuclear Structure Functions at Jefferson Lab

This thesis presents a study of nuclear modification of quark distributions (the EMC effect) using inclusive electron-scattering data from Jefferson Lab Hall C, with emphasis on experiment E12-10-008 (XEM2). The analysis spans nuclei from light to heavy targets and combines measurements at multiple spectrometer settings to constrain EMC ratios over a broad range in Bjorken-x and Q2. A complete analysis framework was developed to extract charge-normalized and efficiency-corrected yields, including detector calibrations, beam-current calibration, density-loss corrections for cryogenic targets, background subtraction, radiative and Coulomb corrections, and systematic studies. Instrumental cross-checks, including HMS–SHMS comparisons and reconstruction studies, show that residual spectrometer differences are predominantly multiplicative in the kinematic region relevant to the EMC analysis. The extracted EMC ratios are broadly consistent with previous measurements while extending coverage across many nuclei. The EMC slope increases from light to heavy nuclei and shows signs of saturation at large A. After accounting for the dominant A dependence, the results are consistent with no isospin dependence, but also consistent with the predicted modification from the isovector model.

Sharda, Abhyuday [Univ. of Tennessee, Knoxville, T↗

A sub-5 ps jitter time-to-digital converter ASIC with back-gate delay tuning in 22 nm CMOS

We present the design of a Time-to-Digital Converter (TDC) ASIC together with performance characterization results at cryogenic temperature (6-8 K), and at room temperature using emulated Low-Gain Avalanche Detector (LGAD) signals. The TDC design uses a two-step architecture with a ring-oscillator based counter and a Vernier delay line fine TDC. The TDC is implemented in an FD-SOI process, and back-gate tuning is used not only to correct threshold variation due to cryogenic operation, but also as a novel way to tune TDC delay elements with very little overhead. Using this technique, we demonstrate a design with very low power (0.5 mW) and area (0.003 mm 2 ). We present test results using the Fermilab Constant Fraction Discriminator (FCFD) ASIC to produce discriminated signals from an internal charge injection mechanism that mimics the waveform and signal amplitude of minimum ionizing particles impinging on LGAD sensors. We characterize the time precision of the full system and verify that the TDC ASIC contributes a negligible amount to the total system time precision, fully consistent with the expected jitter contribution of less than 5 ps. In conclusion, the results presented here demonstrate the utility of our TDC for applications in physics and quantum communications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flow and thermal modelling of the argon volume in the DarkSide-20k TPC

The DarkSide-20k dark matter experiment, currently under construction at LNGS, features a dual-phase time projection chamber (TPC) with a ∼ 50 t argon target from an underground well. At this scale, it is crucial to optimise the argon flow pattern for efficient target purification and for fast distribution of internal gaseous calibration sources with lifetimes of the order of hours. To this end, we have performed computational fluid dynamics simulations and heat transfer calculations. The residence time distribution shows that the detector is well-mixed on time-scales of the turnover time (∼ 40 d). Notably, simulations show that despite a two-order-of-magnitude difference between the turnover time and the half-life of 83m Kr of 1.83 h, source atoms have the highest probability to reach the centre of the TPC 13 min after their injection, allowing for a homogeneous distribution before undergoing radioactive decay. We further analyse the thermal aspects of dual-phase operation and define the requirements for the formation of a stable gas pocket on top of the liquid. We find a best-estimate value for the heat transfer rate at the liquid-gas interface of 62 W with an upper limit of 144 W and a minimum gas pocket inlet temperature of 89 K to avoid condensation on the acrylic anode. This study also informs the placement of liquid inlets and outlets in the TPC. The presented techniques are widely applicable to other large-scale, noble-liquid detectors.

47 OTHER INSTRUMENTATION↗

FGMS-poster

Idaho National Laboratory (INL) performs post irradiation examination (PIE) of tri-structural isotropic (TRISO)-coated particle fuel to help qualify it for high temperature gas cooled reactors. TRISO fuel compacts are re-irradiated in the Neutron Radiography Reactor (NRAD) to generate the short lived fission products needed for fission product release testing. The Fuel Accident Condition Simulator (FACS) furnace and newly added Screen Neutron Irradiated Fuel for Failure (SNIFF) furnace heat the compacts in helium to temperatures of up to 2,000°C, prompting fission product release—predominantly gaseous xenon and krypton isotopes and condensable products such as cesium—from failed particles. These released isotopes are transported to a fission gas monitoring system (FGMS 1 or FGMS 3), where they accumulate in cryogenic cold traps and are quantified using high-purity germanium (HPGe) detectors. The addition of SNIFF and FGMS 3 increases throughput by enabling simultaneous testing of multiple compacts. Furthermore, automated INL developed software provides continuous, near-real time monitoring of fission product inventories and manages the liquid nitrogen cooling of the traps. These system enhancements improve the efficiency, data quality, and testing capacity of TRISO fuel performance evaluations.

07 - ISOTOPES AND RADIATION SOURCES↗

The Simons Observatory: Cryogenic half wave plate rotation mechanism for the small aperture telescopes

We present the requirements, design, and evaluation of the cryogenic continuously rotating half-wave plate (CHWP) for the Simons Observatory (SO). SO is a cosmic microwave background polarization experiment at Parque Astronómico de Atacama in northern Chile that covers a wide range of angular scales using both small (Ø0.42 m) and large (Ø6 m) aperture telescopes. In particular, the small aperture telescopes (SATs) focus on large angular scales for primordial B-mode polarization. To this end, the SATs employ a CHWP to modulate the polarization of the incident light at 8 Hz, suppressing atmospheric 1/f noise and mitigating systematic uncertainties that would otherwise arise due to the differential response of detectors sensitive to orthogonal polarizations. The CHWP consists of a 505 mm diameter achromatic sapphire HWP and a cryogenic rotation mechanism, both of which are cooled down to ~50 K to reduce detector thermal loading. Under normal operation, the HWP is suspended by a superconducting magnetic bearing and rotates with a constant 2 Hz frequency, controlled by an electromagnetic synchronous motor. We find that the number of superconductors and the number of magnets that make up the superconducting magnetic bearing are important design parameters, especially for the rotation mechanism’s vibration performance. The rotation angle is detected through an angular encoder with a noise level of 0.07 μrad √ $\overline{s}$. During a cooldown process, the rotor is held in place by a grip-and-release mechanism that serves as both an alignment device and a thermal path. In this paper, we provide an overview of the SO SAT CHWP: its requirements, hardware design, and laboratory performance.

47 OTHER INSTRUMENTATION↗

Conceptual design of the modular detector and readout system for the CMB-S4 survey experiment

We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background – Stage four (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60% of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4’s science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 m2 of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗