Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cryogen”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Deciphering decomposition pathways of high explosives with cryogenic X-ray Raman spectroscopy

We employed cryogenic X-ray Raman spectroscopy to investigate the early-stage decomposition of the high explosive molecule hexanitrohexaazaisowurtzitane (CL-20). By systematically varying the radiation dose under cryogenic conditions, we induced the decomposition of the molecule using ionizing radiation and observed the evolution of spectral features at the carbon, nitrogen, and oxygen K edges. Through extensive first-principles calculations, we identified key intermediates in the early stages of the decomposition process, resulting from C–C and C–N bond cleavage which leads to the opening of the internal cage structure. A detailed analysis of spectral trends and fingerprints provided evidence supporting N–NO 2 homolytic cleavage as the primary initial decomposition pathway. The combination of advanced core-level spectroscopy methods and state-of-the-art theoretical calculations enabled a comprehensive characterization of the molecular changes induced by controlled radiation dose exposures. In conclusion, our findings establish a benchmark for understanding the decomposition chemistry of high-explosive materials, offering important insights into their stability and reactivity under extreme conditions.

X-ray Raman spectroscopy↗

Cryogenic and Temperature-Dependent Photoelectron Spectroscopy of Metal Complexes

Negative ion photoelectron spectroscopy (NIPES) coupled with electrospray ionization (ESI) has been proved to be a powerful gas-phase spectroscopic tool for characterizing electronic structures and chemical bonding of a variety of cluster anions and corresponding neutral radicals involved in the condensed phase reactions and transformations. Since the acquisition of cryogenic and temperature-controlling capabilities, broader range of research scope has been covered. This review summarizes our recent investigations on metal complexes employing cryogenic ESI-NIPES that provide us essential information towards understanding complicated condensed phase reactions including hydrocarbon activations and electron transfer reactions, and afford us spectroscopic probe of highly reactive transient species and intimate redox pairs. Special attention has been drawn to connect gas phase photodetachment processes with solution phase redox reactions. Photodetachment of transition metal-EDTA complexes has been systematically investigated to model the sequential oxidation reactions of these species in solutions. The obtained gas phase electron affinity (EA) is compared with the solution redox potential (E1/2) and the metal ionization potential (IP) for several series of homologous metal complexes to emphasize their intrinsic correlations with deviations being largely modulated by different degrees of ligand participations.

Yuan, Qinqin↗

Exploring charge transport dynamics in a cryogenic P-type germanium detector

Abstract This study explores the dynamics of charge transport within a cryogenic P-type Ge particle detector, fabricated from a crystal cultivated at the University of South Dakota. By subjecting the detector to cryogenic temperatures and an Am-241 source, we observe evolving charge dynamics and the emergence of cluster dipole states, leading to the impact ionization process at 40 mK. Our analysis focuses on crucial parameters: the zero-field cross-section of cluster dipole states and the binding energy of these states. For the Ge detector in our investigation, the zero-field cross-section of cluster dipole states is determined to be 8.45 × 10 −11 ± 4.22 × 10 −12 cm 2 . Examination of the binding energy associated with cluster dipole states, formed by charge trapping onto dipole states during the freeze-out process, reveals a value of 0.034 ± 0.0017 meV. These findings shed light on the intricate charge states influenced by the interplay of temperature and electric field, with potential implications for the sensitivity in detecting low-mass dark matter.

Physics↗

Proton Improvement Plan II Cryogenic Distribution System thermodynamic design

The Proton Improvement Plan – II (PIP-II) is a superconducting linear accelerator being built at Fermilab that will provide 800 MeV proton beams for neutrino production. The Linac requires cooling at 40 K, 5 K, and 2 K temperatures, which will be provided by cryogenic helium produced by a Helium Cryoplant and distributed by a Cryogenic Distribution System (CDS). Based primarily on the Linac heat load requirements at each temperature and the allowable pressure drop, we have made a preliminary thermodynamic design of the CDS. The design also incorporates special requirements such as controlled and/or fast cooldown of the superconducting RF cavities and their dual maximum allowable working pressures. This paper presents the overall features of the PIP-II CDS, sizing of helium process circuits, different operating modes, and calculated mass flow capacities that cater to these operating modes.

43 PARTICLE ACCELERATORS↗

PIP-II Injector Test Cryogenic Transfer Line

PIP-II Injector Test will test a nearly full-scale front end of PIP-II accelerator. The cryogenic transfer line will provide 2 K, 5 K and 40 K refrigeration for Half Wave Resonator and Single Spoke Resonator cryomodules. This paper will focus on design, installation and operation plan of the cryogenic transfer line.

43 PARTICLE ACCELERATORS↗

Status of the LCLS-II Cryogenic Distribution System

The LINAC Coherent Light Source II (LCLS-II) located at SLAC National Accelerator Laboratory (SLAC) in Menlo Park, CA, is a U.S. Department of Energy project tasked to design and build a world-class x-ray free-electron laser facility for scientific research. The Linac has superconducting radio frequency cryomodules that are connected to the cryogenic plant by the Cryogenic Distribution System (CDS), which consists of distribution boxes with heat exchangers and reliefs, feed caps, end caps, and surface, vertical, and bypass transfer lines. The CDS components were designed and built to specification by industry. The components have been delivered and their installation at SLAC will be discussed. The as-built relief system design will be presented, showing minimization of relief inlet pressure drops while meeting capacity requirements. The relieving flow pressure drops along the lengths of the CDS to centrally located reliefs at the distribution box were analysed to satisfy Pressure Vessel and Process Piping Code criteria to ensure relief performance. The sub-atmospheric 2 K circuit relieving approach will be discussed, which includes a three-way diverter isolation valve suitable for sub-atmospheric service. The component anchoring load design approach and installation into concrete floor will be discussed. This addresses loading, including seismic loading, along the component’s load path to floor anchoring system.

43 PARTICLE ACCELERATORS↗

Time-resolved cryogenic electron tomography for the study of transient cellular processes

Cryogenic electron tomography (cryo-ET) is the highest resolution imaging technique applicable to the life sciences, enabling sub-nanometer visualization of specimens preserved in their near native states. The rapid plunge freezing process used to prepare samples lends itself to time-resolved studies, which researchers have pursued for in vitro samples for decades. Here, we focus on developing a freezing apparatus for time-resolved studies in situ. The device mixes cellular samples with solution-phase stimulants before spraying them directly onto an electron microscopy grid that is transiting into cryogenic liquid ethane. By varying the flow rates of cell and stimulant solutions within the device, we can control the reaction time from tens of milliseconds to over a second prior to freezing. In a proof-of-principle demonstration, the freezing method is applied to a model bacterium, Caulobacter crescentus, mixed with an acidic buffer. Through cryo-ET we resolved structural changes throughout the cell, including surface-layer protein dissolution, outer membrane deformation, and cytosolic rearrangement, all within 1.5 seconds of reaction time. This new approach, Time-Resolved cryo-ET (TR-cryo-ET), enhances the capabilities of cryo-ET by incorporating a sub-second temporal axis and enables the visualization of induced structural changes at the molecular, organelle, or cellular level.

59 BASIC BIOLOGICAL SCIENCES↗

Difficult Measurements of Materials Systems at Cryogenic Temperatures: Cryo-EELS and Cryo-4D-STEM

Scanning/transmission electron microscopy (S/TEM) in materials science has traditionally been accomplished at room temperature due to their solid state in this temperature range and relative insensitivity to radiolysis damage. Cooling to cryogenic temperatures tended to introduce instabilities such as vibration and drift and can lead to the buildup of carbon contamination or ice reducing contrast. The need to expand TEM experimental techniques into new fields such as quantum and battery materials led to new efforts to reduce these instabilities while achieving temperatures at or well below liquid nitrogen (77 K). Further, developments in detector and spectrometer technology brought new capabilities for high resolution electron energy loss spectroscopy (EELS) and scanning nanodiffraction (4D-STEM). These experimental modalities can require even tighter controls of drift, vibration, and exposure time. Here this presentation will discuss accomplishing difficult experiments at cryogenic temperatures in honor of the late Dr. Lena Kourkoutis who inspired and led many such experiments.

36 MATERIALS SCIENCE↗

Optical Interference for the Guidance of Cryogenic Focused Ion Beam Milling Beyond the Axial Diffraction Limit

Using a tri-coincident cryogenic FIB-SEM-LM system, we identify an interferometric optical response that can be used for targeting lamella production to fluorescently labelled structures with accuracy beyond the diffraction limit. We demonstrate the approach using synthetic samples of fluorescent beads embedded in micron-scale droplets of water. Here, we then apply the approach to capture virions inside host cells. Successful targeting is confirmed by cryogenic electron tomography revealing clusters of virions in intracellular vesicles.

Sica, Anthony V. [SLAC National Accelerator Labora↗

Conjugate Multimode Heat Transfer Analysis of Cryogenic EXLO Manipulation

Abstract In this study, a conjugate radiation/conduction multimode heat transfer analysis of cryogenic focused ion beam (FIB) milling steps necessary for producing ex situ lift out specimens under cryogenic conditions (cryo-EXLO) is performed. Using finite volume for transient heat conduction and enclosure theory for radiation heat transfer, the analysis shows that as long as the specimen is attached or touching the FIB side wall trenches, the specimen will remain vitreous indefinitely, while actively cooled at liquid nitrogen (LN2) temperatures. To simulate the time needed to perform a transfer step to move the bulk sample containing the FIB-thinned specimen from the cryo-FIB to the cryo-EXLO cryostat, the LN2 temperature active cooling is turned off after steady-state conditions are reached and the specimen is monitored over time until the critical devitrification temperature is reached. Under these conditions, the sample will remain vitreous for >3 min, which is more than enough time needed to perform the cryo-transfer step from the FIB to the cryostat, which takes only ∼10 s. Cryo-transmission electron microscopy images of a manipulated cryo-EXLO yeast specimen prepared with cryo-FIB corroborates the heat transfer analysis.

Materials Science↗

Low-energy calibration of SuperCDMS HVeV cryogenic silicon calorimeters using Compton steps

Cryogenic calorimeters for low-mass dark matter searches have achieved sub-eV energy resolutions, driving advances in both low-energy calibration techniques and our understanding of detector physics. The energy deposition spectrum of gamma rays scattering off target materials exhibits step-like features, known as Compton steps, near the binding energies of atomic electrons. Here, we demonstrate a successful use of Compton steps for sub-keV calibration of cryogenic silicon calorimeters, utilizing four SuperCDMS High-Voltage eV-resolution detectors operated with 0 V bias across the crystal. This new calibration at 0 V is compared with the established high-voltage calibration using optical photons. The comparison indicates that the detector response at 0 V is about 30% weaker than expected, highlighting challenges in detector response modeling for low-mass dark matter searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Novel technique for the study of pileup events in cryogenic bolometers

Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our approach, which consists of producing controlled pile-up events with a programmable waveform generator, has the benefit that we can reliably and reproducibly control the time separation and relative energy of the individual components of the generated pile-up events. The resulting data allow us to optimize and benchmark analysis strategies to discriminate between individual and pile-up pulses. We describe a test of this technique performed with a small array of detectors at the Laboratori Nazionali del Gran Sasso, in Italy; we obtain a 90% rejection efficiency against pulser-generated pile-up events with rise time of ~15 ms down to time separation between the individual events of 2 ms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A lathe system for micrometre-sized cylindrical sample preparation at room and cryogenic temperatures

A simple two-spindle based lathe system for the preparation of cylindrical samples intended for X-ray tomography is presented. The setup can operate at room temperature as well as under cryogenic conditions, allowing the preparation of samples down to 20 and 50 µm in diameter, respectively, within minutes. Case studies are presented involving the preparation of a brittle biomineral brachiopod shell and cryogenically fixed soft brain tissue, and their examination by means of ptychographic X-ray computed tomography reveals the preparation method to be mainly free from causing artefacts. Since this lathe system easily yields near-cylindrical samples ideal for tomography, a usage for a wide variety of otherwise challenging specimens is anticipated, in addition to potential use as a time- and cost-saving tool prior to focused ion-beam milling. Fast sample preparation becomes especially important in relation to shorter measurement times expected in next-generation synchrotron sources.

36 MATERIALS SCIENCE↗

Low-loss adiabatic fiber-optic coupler for cryogenic photonics

Recent developments in quantum light–matter coupled systems and quantum transducers have highlighted the need for cryogenic optical measurements. In this study, we present a packaged fiber-optic coupler with a coupling efficiency of over 50% for telecom wavelength light down to the mK temperature range. Besides the high coupling efficiency, our method enables sensitive photonic device measurements that are immune to mechanical vibrations present in cryogenic setups.

Optics↗

First Results from a Nb3Sn-Coated 1.5-Cell 650 MHz SRF Cavity for Cryogen-Free Industrial Accelerators

First Results from a Nb3Sn-Coated 1.5-Cell 650 MHz SRF Cavity for Cryogen-Free Industrial Accelerators ABSTRACT = Fermilab is advancing the development of a compact, high-power electron beam accelerator using superconducting radio frequency (SRF) technology as a non-radioactive alternative to traditional radiological sources. The current design targets continuous-wave (CW) operation at \SI{1.6}{MeV} and \SI{20}{kW}. To ensure suitability for industrial environments, the system is being designed for cryogen-free operation, driving the adoption of a novel Nb$_3$Sn-coated 1.5-cell SRF cavity operating at \SI{650}{MHz}. This contribution reports on the fabrication, surface preparation, and Nb$_3$Sn coating process of the cavity, as well as first results from vertical test stand (VTS) measurements performed in a liquid helium bath. These initial tests mark a key milestone toward demonstrating the viability of conduction-cooled Nb$_3$Sn SRF cavities for industrial-scale deployment.

Tagdulang, N. [Fermilab]↗

The DarkSide-20k TPC and underground argon cryogenic system

DarkSide-20k (DS-20k) will exploit the physical and chemical properties of liquid argon (LAr) housed within a large dual-phase time project chamber (TPC) in its direct search for dark matter. The TPC will utilize a compact, integrated design with many novel features to enable the 20t fiducial volume of underground argon. Underground Argon (UAr) is sourced from underground CO _2 2 wells and depleted in the radioactive isotope ^{39} 39 Ar, greatly enhancing the experimental sensitivity to dark matter interactions. Sourcing and transporting the \mathcal{O} 𝒪 (100t) of UAr for (DS-20k) is costly, and a dedicated single-closed-loop cryogenic system has been designed, constructed, and tested to handle the valuable UAr. We present an overview of the (DS-20k) TPC design and the first results from the UAr cryogenic system.

Thorpe, Thomas N.↗

Millikelvin Cryogenics at Fermilab

Millikelvin cryogenics is an emergent area for Fermilab with broad applications in particle detection for the cosmic frontier and quantum information science. Fermilab Cryogenic Engineering currently supports multiple experiments, including the SuperCDMS SNOLAB and ADMX dark matter experiments, along with several millikelvin test facilities. More programs are expected to come online in future.

43 PARTICLE ACCELERATORS↗

C1Po2D-04: Cryogenic Testing of the First HL-LHC Q1/Q3 Cryo-Assembly at

In early 2023, Fermilab is conducting horizontal cryogenic testing of the first Q1/Q3 Cryo-Assembly for the high-luminosity LHC upgrade (HL-LHC). The Cryo-Assembly was installed on the upgraded Fermilab horizontal test stand previously used for testing the LHC inner triplet quadrupoles. The cryogenic process requirements of this test include controlled cool-down and warm-up with a 100 K maximum temperature differential between the two ends of the cold mass, operation of a 1.3 bar, 1.9 K bath of subcooled superfluid helium during power testing and magnetic measurements, and operation at pressure up to 18 bar with full helium recovery after a quench.

Rabehl, R.↗