Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Crosstalk”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Compact Focal Plane Assembly for Planetary Science

A compact radiometric focal plane assembly (FPA) has been designed in which the filters are individually co-registered over compact thermopile pixels. This allows for construction of an ultralightweight and compact radiometric instrument. The FPA also incorporates micromachined baffles in order to mitigate crosstalk and low-pass filter windows in order to eliminate high-frequency radiation. Compact metal mesh bandpass filters were fabricated for the far infrared (FIR) spectral range (17 to 100 microns), a game-changing technology for future planetary FIR instruments. This fabrication approach allows the dimensions of individual metal mesh filters to be tailored with better than 10- micron precision. In contrast, conventional compact filters employed in recent missions and in near-term instruments consist of large filter sheets manually cut into much smaller pieces, which is a much less precise and much more labor-intensive, expensive, and difficult process. Filter performance was validated by integrating them with thermopile arrays. Demonstration of the FPA will require the integration of two technologies. The first technology is compact, lightweight, robust against cryogenic thermal cycling, and radiation-hard micromachined bandpass filters. They consist of a copper mesh supported on a deep reactive ion-etched silicon frame. This design architecture is advantageous when constructing a lightweight and compact instrument because (1) the frame acts like a jig and facilitates filter integration with the FPA, (2) the frame can be designed so as to maximize the FPA field of view, (3) the frame can be simultaneously used as a baffle for mitigating crosstalk, and (4) micron-scale alignment features can be patterned so as to permit high-precision filter stacking and, consequently, increase the filter bandwidth and sharpen the out-of-band rolloff. The second technology consists of leveraging, from another project, compact and lightweight Bi0.87Sb0.13/Sb arrayed thermopiles. These detectors consist of 30-layer thermopiles deposited in series upon a silicon nitride membrane. At 300 K, the thermopile arrays are highly linear over many orders of magnitude of incident IR power, and have a reported specific detectivity that exceeds the requirements imposed on future mission concepts. The bandpass filter array board is integrated with a thermopile array board by mounting both boards on a machined aluminum jig.

Brown, Ari↗

Dynamic Black-Level Correction and Artifact Flagging in the Kepler Data Pipeline

Instrument-induced artifacts in the raw Kepler pixel data include time-varying crosstalk from the fine guidance sensor (FGS) clock signals, manifestations of drifting moiré pattern as locally correlated nonstationary noise and rolling bands in the images which find their way into the calibrated pixel time series and ultimately into the calibrated target flux time series. Using a combination of raw science pixel data, full frame images, reverse-clocked pixel data and ancillary temperature data the Keplerpipeline models and removes the FGS crosstalk artifacts by dynamically adjusting the black level correction. By examining the residuals to the model fits, the pipeline detects and flags spatial regions and time intervals of strong time-varying blacklevel (rolling bands ) on a per row per cadence basis. These flags are made available to downstream users of the data since the uncorrected rolling band artifacts could complicate processing or lead to misinterpretation of instrument behavior as stellar. This model fitting and artifact flagging is performed within the new stand-alone pipeline model called Dynablack. We discuss the implementation of Dynablack in the Kepler data pipeline and present results regarding the improvement in calibrated pixels and the expected improvement in cotrending performances as a result of including FGS corrections in the calibration. We also discuss the effectiveness of the rolling band flagging for downstream users and illustrate with some affected light curves.

Clarke, B. D.↗

In-Flight Performance of the Polarization Modulator in the CLASP Rocket Experiment

We developed a polarization modulation unit (PMU), a motor system to rotate a waveplate continuously. In polarization measurements, the continuous rotating waveplate is an important element as well as a polarization analyzer to record the incident polarization in a time series of camera exposures. The control logic of PMU was originally developed for the next Japanese solar observation satellite SOLAR-C by the SOLAR-C working group. We applied this PMU for the Chromospheric Lyman‐alpha SpectroPolarimeter (CLASP). CLASP is a sounding rocket experiment to observe the linear polarization of the Lyman‐alpha emission (121.6 nm vacuum ultraviolet) from the upper chromosphere and transition region of the Sun with a high polarization sensitivity of 0.1 % for the first time and investigate their vector magnetic field by the Hanle effect. The driver circuit was developed to optimize the rotation for the CLASP waveplate (12.5 rotations per minute). Rotation non‐uniformity of the waveplate causes error in the polarization degree (i.e. scale error) and crosstalk between Stokes components. We confirmed that PMU has superior rotation uniformity in the ground test and the scale error and crosstalk of Stokes Q and U are less than 0.01 %. After PMU was attached to the CLASP instrument, we performed vibration tests and confirmed all PMU functions performance including rotation uniformity did not change. CLASP was successfully launched on September 3, 2015, and PMU functioned well as designed. PMU achieved a good rotation uniformity, and the high precision polarization measurement of CLASP was successfully achieved.

CLASP↗

The CHARIS IFS for high contrast imaging at Subaru

The Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) is an integral field spectrograph (IFS) being built for the Subaru telescope. CHARIS will take spectra of brown dwarfs and hot Jovian planets in the coronagraphic image provided by the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) and AO188 adaptive optics systems. The system is designed to detect objects five orders of magnitude dimmer than their parent star down to an 80 milliarcsecond inner working angle. For characterization, CHARIS has a high-resolution prism providing an average spectral resolution of R82, R69, and R82 in J, H, and K bands respectively. The so-called discovery mode uses a second low-resolution prism with an average spectral resolution of R19 spanning 1.15-2.37 microns (J+H+K bands). This is unique compared to other high contrast IFS designs. It augments low inner working angle performance by reducing the separation at which we can rely on spectral differential imaging. The principal challenge for a high-contrast IFS is quasi-static speckles, which cause undue levels of spectral crosstalk. CHARIS has addressed this through several key design aspects that should constrain crosstalk between adjacent spectral features to be below 1%. Sitting on the Nasmyth platform, the alignment between the lenslet array, prism, and detector will be highly stable, key for the performance of the data pipeline. Nearly every component has arrived and the project is entering its final build phase. Here we review the science case, the resulting design, status of final construction, and lessons learned that are directly applicable to future exoplanet instruments.

Subaru Coronagraphic Extreme Adaptive Optics (SCEx↗

Laboratory Testing and Performance Verification of the CHARIS Integral Field Spectrograph

The Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) is an integral field spectrograph (IFS) that has been built for the Subaru telescope. CHARIS has two imaging modes; the high-resolution mode is R82, R69, and R82 in J, H, and K bands respectively while the low-resolution discovery mode uses a second low-resolution prism with R19 spanning 1.15-2.37 microns (J+H+K bands). The discovery mode is meant to augment the low inner working angle of the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) adaptive optics system, which feeds CHARIS a coronagraphic image. The goal is to detect and characterize brown dwarfs and hot Jovian planets down to contrasts five orders of magnitude dimmer than their parent star at an inner working angle as low as 80 milliarcseconds. CHARIS constrains spectral crosstalk through several key aspects of the optical design. Additionally, the repeatability of alignment of certain optical components is critical to the calibrations required for the data pipeline. Specifically the relative alignment of the lens let array, prism, and detector must be highly stable and repeatable between imaging modes. We report on the measured repeatability and stability of these mechanisms, measurements of spectral crosstalk in the instrument, and the propagation of these errors through the data pipeline. Another key design feature of CHARIS is the prism, which pairs Barium Fluoride with Ohara L-BBH2 high index glass. The dispersion of the prism is significantly more uniform than other glass choices, and the CHARIS prisms represent the first NIR astronomical instrument that uses L-BBH2as the high index material. This material choice was key to the utility of the discovery mode, so significant efforts were put into cryogenic characterization of the material. The final performance of the prism assemblies in their operating environment is described in detail. The spectrograph is going through final alignment, cryogenic cycling, and is being delivered to the Subaru telescope in April 2016. This paper is a report on the laboratory performance of the spectrograph, and its current status in the commissioning process so that observers will better understand the instrument capabilities. We will also discuss the lessons learned during the testing process and their impact on future high-contrast imaging spectrographs for wavefront control.

Coronagraphic High Angular Resolution Imaging Spec↗

The CHARIS High-Contrast Integral-Field Spectrograph

One of the leading direct Imaging techniques, particularly in ground-based imaging, uses a coronagraphic system and integral field spectrograph (IFS). The Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) is an IFS that has been built for the Subaru telescope. CHARIS has been delivered to the observatory and now sits behind the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) system. CHARIS has 'high' and 'low' resolution operating modes. The "high-resolution" mode is used to characterize targets in J, H, and K bands at ~R70. The "low-resolution" prism is meant for discovery and spans J+H+K bands (1.15-2.37 microns) with a spectral resolution of ~R18. This discovery mode has already proven better than 15-sigma detections of HR8799c,d,e when combining ADI+SDI. Using SDI alone, planets c and d have been detected in a single 24 second image. The CHARIS team is optimizing instrument performance and refining ADI+SDI recombination to maximize our contrast detection limit. In addition to the new observing modes, CHARIS has demonstrated a design with high robustness to spectral crosstalk. CHARIS is in the final stages of commissioning, with the instrument open for science observations beginning February 2017. Here we review the science case, design, on-sky performance, engineering observations of exoplanet and disk targets, and specific lessons learned for extremely high contrast imagers. Key design aspects that will be demonstrated are crosstalk optimization, wavefront correction using the IFS image, lenslet tolerancing, the required spectral resolution to fit exoplanet atmospheres, and the utility of the spectrum in achieving higher contrast detection limits.

Groff, Tyler D.↗

Kepler Instrument Performance: An In-Flight Update

The Kepler Mission is designed to detect the 80 parts per million (ppm) signal from an Earth-Sun equivalent transit. Such precision requires superb instrument stability on time scales up to 2 days and systematic error removal to better than 20 ppm. The sole scientic instrument is the Photometer, a 0.95 m aperture Schmidt telescope that feeds the 94.6 million pixel CCD detector array, which contains both Science and Fine Guidance Sensor (FGS) CCDs. Since Kepler's launch in March 2009, we have been using the commissioning and science operations data to characterize the instrument and monitor its performance. We find that the in-flight detector properties of the focal plane, including bias levels, read noise, gain, linearity, saturation, FGS to Science crosstalk,and video crosstalk between Science CCDs, are essentially unchanged from their pre-launch values. Kepler'sunprecedented sensitivity and stability in space have allowed us to measure both short- and long- term effects from cosmic rays, see interactions of previously known image artifacts with starlight, and uncover several unexpected systematics that affect photometric precision. Based on these results, we expect to attain Kepler's planned photometric precision over 90% of the field of view.

CCD↗

Characterization a single-lens based stereoscopic camera

Traditional stereoscopic vision (3D) is achieved through use of two cameras arranged to emulate human eyes. While this method works on large scale projects, it becomes impractical to use on small scale designs, such as surgical endoscopes, in which the operational area doesn’t allow the immensity of dual camera systems. This project is focused on developing a stereoscopic endoscope using a single camera and Conjugated Multiple-Bandpass Filters (CMBF) to create 3D images. Each filter is designed to allow only a distinct spectrum of light to pass through. The stereoscopic image can be obtained by using filters that reflect and reject wavelengths, complementary to one another. A major concern in all stereovision is crosstalk, defined as the light from one eye image that is present in the other eye image. This incomplete isolation causes deterioration of the 3D image. In our system, the crosstalk comes from imperfect filters. The filter spectrums overlap at certain wavelengths, causing a dim outline of the right eye image to leak into the left eye image and vice versa, a phenomenon known as ghosting. Knowledge of the extent of this phenomenon is critical to creating sustainable, effective stereovision.

Fritz, Eric↗

Power and Signal Integrity Findings in a FPGA Layout for an Aerospace Application

Design principles concerning the use of FPGA are of particular importance in aerospace applications since the neglect of such design principles can cause catastrophic effects in aerospace system, as it will be explained in this paper. FPGA design rules such as power conditioning and signal integrity for properly interfacing high speed FPGA with its interface circuits are discussed in this paper as it relates to aerospace systems. Signal integrity to avoid crosstalk within a FPGA has not been a great concern because most of the attention over the years had been on signal integrity at the PCB level. However, this paper shows a real example of crosstalk within a FPGA in an aerospace application.

Perez, Reinaldo J.↗

On-Orbit Calibration and Performance Assessments of Terra and Aqua Modis Thermal Emissive Bands

Terra and Aqua MODIS have successfully operated for more than 20 and 18 years, respectively, and far exceeded their designed lifetimes of 6 years. MODIS has 36 spectral bands, among which 16 are the thermal emissive bands (TEB) covering a wavelength range from 3.75 to 14.24 μm. Observations from the MODIS TEB have been used to generate a number of data products, such as surface/cloud/atmospheric temperatures, cloud top altitude, and water vapor properties. To a large extent, the quality of the MODIS L1B radiance product has been maintained through the entirety of each mission via extensive on-orbit calibration and validation efforts. MODIS TEB calibration uses a quadratic algorithm and is referenced to an on-board blackbody with its temperature measurements traceable to the NIST standard. We provide an overview of the MODIS instrument operations, key TEB calibration activities, and algorithms used in the latest L1B data Collection 6.1 (C6.1) and describe the TEB on-orbit performance for both Terra and Aqua MODIS. The TEB gain trends have been stable to within 5% over the Terra mission after 2003 under the same electronic configuration, except for bands 27 to 30, and within 3% over the Aqua mission. The Terra MODIS optical crosstalk correction implemented right after launch has been very effective in removing the ghost images in its photoconductive detector bands 32 to 36. Starting from C6.1, an electronic crosstalk correction algorithm has also been applied to the Terra MODIS photovoltaic detector long-wave infrared bands 27 to 30. The noise characterization performance remains stable with most TEB detectors continuously meeting their design requirements. A gradual loss of the Aqua MODIS radiative cooler margin reached its maximum in 2013 and has been slowly recovering since then. On-orbit changes in TEB response versus scan angle are extremely small based on pitch maneuver observations and assessments using vicarious approaches. The remaining challenges in TEB calibration and proposed improvements for the upcoming data collection with L1B data production and reprocessing are discussed.

Terra↗

Analysis of the on-orbit Response-Versus-Scan-angle for the MODIS SWIR Bands Derived from Lunar Observations

The Moderate Resolution Imaging Spectroradiometer (MODIS) on board the Terra and Aqua platforms is a multi-spectral, whiskbroom scanning radiometer with 36 spectral bands covering wavelengths from 0:4 - 14:2 μm. Among these bands, the 20 reflective solar bands (RSB, 0:4 - 2:1 μm) use an on-board solar difuser (SD) and SD stability monitor (SDSM) to track the detector gain changes on orbit. In addition to this, lunar and Earth-view (EV) observations are used in order to characterize the scan-mirror response versus scan angle (RVS), which improves the Earth-view retrieval over the full width of each scan. For the short-wave infrared bands (SWIR, 1:2 - 2:1 μm), the prelaunch RVS has been used for both Aqua and Terra MODIS throughout each mission. While these bands are not expected to have a significant change in the RVS on-orbit, issues such as electronic crosstalk and an out-of-band optical leak have prevented the use of the Moon for deriving the on-orbit RVS for validation. However, recent improvements to the MODIS lunar calibration for the SWIR bands allow us to mitigate the electronic crosstalk impact and derive the RVS for the SWIR bands. In this work, we will assess the impact of this newly derived RVS on the EV data compared to MODIS Collection 6.1. By comparing to EV data obtained from pseudo-invariant calibration sites at different angles-of-incidence on the scan mirror, we can assess the effectiveness of the newly derived RVS from the Moon. We find that while the change in the RVS on-orbit for the SWIR bands is relatively small, applying a correction to the RVS based on the Moon and SD data can provide an improvement for some bands.

MODIS↗

Mock Truss-Braced Wing Loads Calibration Research Utilizing Fiber-Optic Sensors

In support of the National Aeronautics and Space Administration Advanced Air Transonic Transport Truss-Braced Wing structural research, the Armstrong Flight Research Center Flight Loads Laboratory is performing pathfinder tests on a small, scaled test article (dubbed the mock Truss-Braced Wing) to study the application of a loads calibration on a truss-braced wing structure. The addition of a truss to the wing structure, as opposed to a purely cantilever beam setup, changes the strain-gage-based loads calibration techniques. In a truss-braced configuration, the internal shear and moments, inboard of the truss-wing connection, are not directly representative of the external aerodynamic loading as is the case for a traditional cantilever configuration. A 3-axis load cell was used at the wing-to-strut interface to estimate the load sharing between the two structural members. Crosstalk within the 3-axis load cell is added to the measurement uncertainties of the calibration effort, and the results, including crosstalk uncertainties, are presented. The calibration tests presented in this report are used as a pathfinder for developing an understanding how to perform loads calibration on a truss-braced wing structural configuration. The use of distributed fiber-optic strain sensors is leveraged to provide a near-full-span strain profile along the leading and trailing edge of the wing structure for strain-based loads calibration.

Francisco Peña↗

Efficient Mirrorlet Array Based Integral Field Spectrometer for HWO

Habitable World Observatory (HWO) is a NASA strategic mission recommended by 2020 astronomical decadal survey. Integral spectrometers play an important role to verify if the observed exoplanet is habitable. The traditional lenslet array based Integral Field Spectrometer (IFS) has the advantage of simplicity and compactness. However, it does not use detector pixels efficiently in order to prevent wavelength crosstalk among adjacent spectra. The efficient lenslet/mirrorlet IFS combines the advantages from both lenslet based and imager slicer based IFSes—keeping lenslet IFS’s simplicity and compactness, concurrently adding slicer IFS’s detector efficiency. This paper discusses the principle of efficient lenslet/mirrorlet IFS, design philosophy, and efficient spectral trace layout ideals. It uses HWO NIR IFS requirement as an example to provide an efficiency mirrorlet IFS optical design. The high detector efficiency not only reduces Needed detector pixel numbers, but also reduce the high communication rate demanding for much a large multiple instrument mission. The basic idea of the efficient lenslet/mirrorlet array IFS is to design a lenslet/mirrorlet array in such a way that the images from multiple mirrorlets are grouped and aligned as a spectrum from a single slit. Therefore, the number of detector rows used to prevent wavelength crosstalk is no longer needed. This paper is also going to address how to lay the traces on the detector and what is the difference from the traditional lenslet IFS. Our goal is to show that such an IFS is capable to lay all spectral traces onto a 2k x 2k detector array using HWO NIR requirement that has a higher spectral resolving power R = 70 and a large Field of View (FOV) of 96 λ/D.

Exoplanet↗

Laboratory Measurements of Instrumental Signatures of the LSST Camera Focal Plane

Electro-optical testing and characterization of the Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST) Camera focal plane, consisting of 205 charge-coupled devices (CCDs) arranged into 21 stand-alone Raft Tower Modules (RTMs) and 4 Corner Raft Tower Modules (CRTMs), is currently being performed at the SLAC National Accelerator Laboratory. Testing of the camera sensors is performed using a set of custom-built optical projectors, designed to illuminate the full focal plane or specific regions of the focal plane with a series of light illumination patterns: the crosstalk projector, the flat illuminator projector, and the spot grid projector. In addition to measurements of crosstalk, linearity and full well, the ability to project realistically-sized sources, using the spot grid projector, makes possible unique measurements of instrumental signatures such as deferred charge distortions, astrometric shifts due to sensor effects, and the brighter-fatter effect, prior to camera first light. Here we present the optical projector designs and usage, the electro-optical measurements and how these results have been used in testing and improving the LSST Camera instrumental signature removal algorithms.

79 ASTRONOMY AND ASTROPHYSICS↗

Extreme fast charge aging: Effect of electrode loading and NMC composition on inhomogeneous degradation in graphite bulk and electrode/electrolyte interface

Empowering extreme fast charging (XFC) requires a comprehensive understanding of its application with advanced anode and cathode materials in lithium-ion batteries. No report exists for the full extent of limitations for the anode with crosstalk effect from paired cathode as well as Li plating due to electrode loading under XFC. In this study, a combination of cell testing and multiple length characterization is used to investigate XFC aging mechanism in cells with a low loading of 1.5 mAh cm -2 and high loading of 2.5 mAh cm -2 for graphite (Gr)/Ni-rich LiNi x Mn y Co 1-x-y O 2 (NMCs). Operando XRD mappings show 1.5 mAh cm -2 loadings result in higher strain in graphite for all three cathode types. Among the three NMC cathodes, the graphite from NMC532 and NMC811 cells show comparable strain. Scanning electron microscopy (SEM) images show distinct differences between 6-C-charged anodes in two loadings. Significantly increased electrode thickness can be seen due to more damage in the graphite bulk and accumulation of the electrolyte decomposition products in electrode pores. X-ray photoelectron spectroscopy (XPS) reveals both cathode chemistry and Li plating influence the non-uniform SEI composition on graphite surface. We report higher Ni content in NMC811 promotes the higher levels of salt decomposition on the SEI and formation of higher mass of electrolyte aging products.

25 ENERGY STORAGE↗

Subsample Difference Correction for Terra MODIS SWIR Bands 5-7 Using Lunar Observations

The Moderate Resolution Imaging Spectroradiometer (MODIS) is one of the key instruments on board the Terra (EOS (Earth Observing Satellite) AM-1) spacecraft. MODIS has 36 spectral bands ranging in wavelength between 0.4 and 14.2 microns, at three spatial resolutions of 250 meters (bands 1-2), 500 meters (bands 3-7), and 1 kilometer (bands 8-36). For each 1-km sample, the 250-m and 500-m bands use 4 and 2 detectors with each acquiring 4 and 2 subsamples respectively in order to maintain consistent along-scan and along-track resolutions at nadir. The SWIR (Short-Wave Infrared) bands, 57 and 26, share the same focal-plane array as the 1-km thermal emissive bands, 20-25. During one of the two 500-m subsamples for bands 57, sampling of the 1-km bands introduces increased electronic crosstalk contamination, resulting in a subsample difference for both Earth-view and on-board calibrator observations. For this work, we use data from lunar and on-board blackbody observations, which occur at different signal levels for bands 20-25, to derive a correction to the contamination. This correction can be applied to reduce the subsample differences in the MODIS Earth-view data over a wide range of scenes. The impact of this correction on the sensor calibration and Earth-view data will be assessed.

SWIR↗

Spatiotemporal Thermal Coupling in VO 2 Device Arrays

Correlated oxides such as VO 2 exhibit an electrically driven insulator–metal transition (IMT) that underlies their promise for neuromorphic and memory devices. Yet the IMT is not a uniform bulk process but a spatiotemporal phenomenon in which local heating nucleates filaments, contracts or dissolves them with the electric field, and couples to the environment. In this work, we directly image the VO 2 IMT dynamics by mid-wave infrared, thermography synchronized with electrical transport, resolving device temperature with micrometer spatial and microsecond temporal resolution. At the single-device level, we capture the full cycle of filament nucleation, contraction, and relaxation during current/voltage-driven resistive switching. At the array level, we show that heat propagates across etched gaps with an effective length scale of ∼131 µm, enabling cooperative behaviors among electrically isolated devices. Short-range distanced devices exhibit mutual filament attraction and sequential dissolution, while long-range distanced devices differentiate into distinct roles: drivers that initiate switching, cooperative responders that undergo assisted self-oscillations, and passive reporters that record the thermal field. Furthermore, these results reframe thermal crosstalk, long regarded as parasitic, as an intrinsic coupling channel and design principle for organizing collective switching behaviors, with direct implications for emergent circuit functionality in neuromorphic and unconventional computing architectures.

coupling↗

Impact of Anode to Cathode Crossover in Lithium‐metal Batteries With High‐Nickel Cathodes

The advancement of high-energy-density lithium-metal batteries (LMBs) is hindered by the chemical instability of both lithium-metal anode and high-nickel layered oxide cathodes. While cathode-to-anode crossover is well-documented, the reverse process of anode-to-cathode crossover remains underexplored. Here, we systematically investigate such crossovers and the degradation pathway in pouch cells with a localized high-concentration electrolyte, comparing NMC622, NMC811, and NMC90 cathodes paired with lithium-metal and graphite anodes. Despite delivering higher initial capacities, LMBs exhibit faster capacity fade under long-term cycling at 45 °C. To isolate cathode-side degradation, galvanostatic electrochemical impedance spectroscopy (GEIS) measurements of cycled cathodes paired with delithiated lithium iron phosphate (LFP) counter electrodes reveal significantly higher charge-transfer resistance in cathodes cycled with lithium-metal. Surface characterization via X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS) reveals greater electrolyte decomposition on cathodes cycled with lithium metal, leading to thicker, more organic-rich cathode–electrolyte interphases (CEIs), consistent with the elevated charge-transfer resistance observed in GEIS measurements. Notably, NMC90 shows the most pronounced CEI thickening, linking higher cathode surface reactivity to greater susceptibility to anode-to-cathode crossover. This work presents compelling evidence of crosstalk degradation originating from lithium-metal anodes and underscores the importance of cross-interface stability for the design of durable LMBs.

25 ENERGY STORAGE↗