Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cost reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

A Process with Decoupled Absorber Kinetics and Solvent Regeneration through Membrane Dewatering and In-Column Heat Transfer (Final Report)

This report summarizes the work conducted on project DE-FE0031604 where University of Kentucky Center for Applied Energy (UK CAER) has validated its intensified CO 2 capture process through substantial enhancements to the kinetics of the absorption process and energy reductions by absorber temperature profile modification, dewatering and heat integration technologies for achieving significant capital and operating cost reductions. To address DOE’s objective of improving post-combustion CO 2 capture technology and reducing associated cost, UK CAER employed an intensified process which combined three key aspects targeted at overcoming inherent limitations or barriers in the conventional CO 2 capture and desorption process. The process designed to be independent of the type of solvent used, included (1) the use of 3-D printed two-channel structured packing material to control the temperature profile and increase the CO 2 absorption rate in the absorber, (2) a zeolite membrane dewatering unit for dewatering of the carbon-rich solvent to decouple solvent concentration needs for CO 2 absorption and desorption, and (3) a rich-split feed with two-phase flow heat transfer prior to the stripper that provided a secondary point of vapor generation to provide energy savings in steam extraction and solvent regeneration. The project was executed over two budget periods. This involved testing of individual process components which included the advanced heat transfer packing and the dewatering membrane on UK CAER’s 30 liter per minute (L/min) CO 2 (3” Column) capture bench unit with simulated flue gas in the first budget period. Subsequent scaled-up testing of these components together with the split-feed configuration were also tested in UK CAER’s 0.1 MWth CO 2 capture unit with coal-derived flue gas in the second-budget period. Long term studies were done during this period to assess process and solvent performance over extended duration. Project partners Lawrence Livermore National Laboratory (LLNL) and Media & Process Technology (MPT) led the development efforts for the advanced packing material and dewatering membrane respectively. Data from the long term testing was used as input for an environmental, health and safety (EH&S) assessment for the process and scaled technology performed by ALL4 LLC. Trimeric Corporation also completed a techno-economic analysis (TEA) for the UK CAER technology which was compared to the DOE reference Case B12B. Tests on the 3” column capture unit showed that the advanced heat transfer packing could be used to lower the bulge temperature in the absorber, and this was also proven in the scaled testing in the 0.1 MWth CO 2 capture unit. The bulge temperature could be lowered by >10 °C, changing the temperature profile in the absorber, and showed potential to enhance absorption with the ability to tailor the profile to provide conditions suitable for a solvent’s properties and kinetics. Conditions for short term evaluation of a 19” zeolite dewatering membrane on the 3” column capture unit yielded desirable fluxes and sustained rejection rates of >80%. However, for the scaled testing of six membrane modules consisting of 21 parts of 31-inch-long membrane tubes in each bundle (surface area 0.3 m 2 ), over a more extended duration, similar rejection rates could not be achieved. With the split-feed of the rich stream to the stripper, improved heat recovery minimized waste heat exiting the top of the stripper. The stripper exhaust temperatures could be reduced by >10 °C; reducing the amount of water vaporization contributed to lowering the regeneration energy by ~ 15%. The energy benefit could be sustained from the long term monitoring of the solvent performance. The solvent properties were not significantly impacted over the long-term operations. The benefits of the UK CAER process demonstrated experimentally were mostly validated from the TEA comparing a commercial scale application of the technology to DOE reference Case B12B. The cost of CO 2 capture for the UK CAER technology was estimated to be ~$34.97/tonne of CO 2 captured; a reduction of 23% compared to Case B12B. The increase in cost of electricity was also shown to be 16% lower than that of Case B12B. The total parasitic demand was also shown to be 11% lower. The key drivers for the benefits are a result of the process intensification approaches employed in the UK CAER technology for enhanced solvent performance, effective heat recovery and improved energy performance. The EH&S assessment did not find any major environmental concerns or barriers to the full scale implementation of the technology.

20 FOSSIL-FUELED POWER PLANTS↗

Optimization and Techno-Economic Comparison of Regenerators and Recuperators in sCO2 Recompression Brayton Cycles for Concentrating Solar Power Applications

Supercritical CO2 power cycles might be capable of providing the cost reductions and efficiency improvements necessary to reach concentrating solar power (CSP) cost targets, but require large, highly effective recuperators. Fixed-bed regenerators are a periodic heat exchanger that could be an effective yet low-cost alternative to these recuperators. This study presents a techno-economic comparison of regenerators and recuperators for a 100 MWe supercritical CO2 power cycle for CSP applications. We quantify the levelized cost of energy (LCOE) for the power plant with both types of heat exchangers, and explore sensitivity of LCOE to parameters such as CSP-specific capital costs, power cycle component capital costs, and regenerator valve replacements costs. Results indicate that the incumbent printed circuit heat exchangers achieve the lowest LCOE, unless the upper extreme of PCHE capital cost and lower extremes of regenerator and valve capital and O&M costs are realized. Sensitivity analysis also illustrates that the primary heat exchanger cost is the most influential of power cycle components, and that CSP component capital cost is more influential than power cycle capital costs. This illustrates the importance of reducing the cost of heliostats, receivers, and thermal energy storage for achieving CSP LCOE targets.

OTHER INSTRUMENTATION,SOLAR ENERGY↗

Technology Demonstration of a High-Pressure Swirl Oxy-Coal Combustor

This technical report presents the exploration of the design and prototyping of a High-Pressure Swirl Oxy-coal Combustor. Pressurized oxy-coal combustion systems have the potential to improve efficiency along with an increased carbon capture rate. Reduction of flue gas at higher pressure, smaller system size, and capital cost reductions render high-pressure oxy-coal systems particularly attractive as next-generation energy-producing systems. High-pressure oxy-coal combustion systems are a recent concept, and thus operability issues of combustor designs for such systems are not fully understood. Significant challenges exist to maintain oxy-coal combustion stability at elevated pressure and a high CO 2 diluent environment. Although a body of knowledge exists for high-pressure oxygen combustion in rocket engines (or similar applications), it is yet to be strategized how these fundamental concepts can be translated to low-temperature CO 2 diluent combustion regimes. The realization of the pressurized oxy-coal based systems requires combustor components to be designed and demonstrated for an operating pressure over 10 bar. However, pressurized oxy-coal combustor design information at this pressure range and scale relevant to validate those proposed systems is currently limited. Experimental data from MWth scale oxy-coal combustors are needed to identify the optimal trade-off between net efficiency and systems size. The proposed effort is aimed at demonstrating a 1 MWth down-fired swirl Oxy-Coal combustor and investigate the interrelation between combustor operating conditions (pressure; flame stability; flue gas recirculation ratio) and conversion efficiencies to minimize oxygen requirements. One of the key challenges is to configure burner design (i.e., swirl number and injector) and operating conditions for high-pressure oxy-coal combustion systems. These experiments differ from current systems partly due to the high theoretical flame temperature and related burner operability issues associated with oxy-combustion. An ASPEN PLUS® model study for 550 MWe TIPS and ENEL pressurized oxy-coal systems with CO 2 recirculation was performed to evaluate system design, subsystems sizing, and operating condition determination. The system analysis effort included TRL and technology gap determination of subsystems and critical components. This information was scaled to develop design requirements (design pressure and flue gas recirculation: RR Flue Gas = $\frac{m_{flue}}{m_{total}}$) for the 1 MWth combustor. The effects of a wide range of carbon dioxide recirculation ratios on the thermal efficiency of ENEL and TIPS cycles are studied. The pressure of 10 bar and 80 bar are used for ENEL and TIPS cycles, respectively. The thermal efficiency of ENEL is significantly higher than the efficiency of TIPS at a pressure of less than 10 bar. The insights from system analysis were then used to design a 1 MWth swirl oxy-coal combustor. Flame temperature analysis and material strength analysis was performed to determine the combustor thickness. The structural integrity of the combustor was validated by finite element analysis using Abacus® and Hypermesh®. Feasibility of igniters and secondary burners are investigated in successful high-pressure oxy-methane combustion. The secondary burners are designed in such a way that it can operate between 100 to 500 kW firing input. Three generations of the pintle injector were designed based on swirl numbers (S=0, 0.9, and 1.2). Key pintle injector parameters such as pintle size, pintle orifice size, spray pattern were investigated by cold flow tests. Information from these tests was used to modify injector design for smooth and successful operation. A 5 mm pintle orifice size was decided upon as the optimum size for oxy-coal operation for the combustor. Shadow sizing experiments were performed to identify the atomization rate of each injector. Different coal water slurry mixtures (30 – 50% coal by wt% in the mixture) at various total momentum ratios (TMR) were investigated for this purpose. These experiments provided decisive information to choose the best design of the injector. The injector with 1.2 swirl provided higher atomization in all cases than other designs. The mean equivalent droplet size of the jet was similar at different TMR and mixture ratios using this injector, thus making it suitable for use in most cases. Therefore, the 1.2 swirl-pintle injector was chosen for the shakedown test. The combustor and other sub-systems, including feed systems and control and data acquisition, have been manufactured, assembled, and integrated. The total system integration and installation began on July 1, 2020. The shake-down tests and initial operational capability demonstration are expected to be completed by September 30, 2020.

01 COAL, LIGNITE, AND PEAT↗

DCFC + Hydrogen Station Design Optimization [Slides]

Both direct current fast charging (DCFC) and Hydrogen stations are working to create successful long-term business models; however, analyses for DCFC and hydrogen fueling infrastructure are almost always performed separately. This work provides a detailed exploration of the benefit of integrating DCFC and hydrogen stations to lower the total system cost from load balancing and equipment cost sharing. To achieve this we have adapted the REopt optimization framework to simultaneously optimize the design and operation of integrated DCFC and H2 fueling station. Results indicate that 1) combining hydrogen fueling and DCFC stations can significantly reduce lifetime costs compared to separated stations. 2) Co-location with additional site load reduces DCFC costs, however, integration of DCFC with hydrogen provides an even greater cost reduction. 3) Adding PV to combined stations further reduces the lifetime station cost. 4) Capital investments in station combination today can help reduce the cost of operating DCFC tomorrow and 5) product diversification acts as a hedge against variability and enables a more dynamic response to market changes.

08 HYDROGEN↗

Low Cost High-Performance HRE-Free 3-in-1 Electric Drive Unit

The project team completed work to expand upon American Axle & Manufacturing’s (AAM) baseline technology and develop a high-speed, AC induction electric drive unit (EDU) with total direct-oil-cooling and integrated power electronics. The project accelerated advancements in EDU technology by allowing AAM to build upon the progress made in developing the underlying baseline technologies. The following seven improvements to AAM’s baseline technology were implemented in this research and development program: 1) Increased speed (30k RPM) AC induction motor, 2) Silver-sintering of discrete silicon carbide (SiC) metal-oxide-semiconductor field-effect transistors (MOSFET) to heat sinks, 3) Electrically insulated rotor bars, 4) Optimized lamination steel, 5) EDU-integrated 650VDC inverter package, 6) Over-molded stator with molded liners, and 7) 650VDC power-dense stator design. The successful development of the technology resulted in a meaningful cost reduction for EDU systems in the market. Coupled with falling battery system costs, lower EDU costs will likely accelerate the market acceptance and related production scaling of battery electric vehicles. The objective of this project was to research, develop, and test a Heavy Rare Earth (HRE)-free 3-In-1 electric drive unit (EDU) that has class leading power density and cost. The key technologies to be developed were anticipated to meet or exceed the Department of Energy (DOE) targets of a cost ≤ $\$$7/kilowatt (kW), power density ≥ 12 kW/liter, and operating voltage ≥ 600 VDC.

33 ADVANCED PROPULSION SYSTEMS↗

Design and Experimental Demonstration of an Additive Manufactured Smart Oxy-Methane Burner for High Pressure and Supercritical Combustion

Pressurized oxy combustion-based systems can improve efficiency by recovering latent heat of the steam in the Flue Gas and achieving 90% CO2 capture. In addition, the novel Directly Heated Supercritical Carbon Dioxide (DH-SCO2) power cycles can achieve high thermal efficiencies and provide nearly full carbon capture. Additionally, due to the reduction of flue gas at higher pressure, smaller system size and capital cost reductions are also possible. Recent thermodynamic analysis of the DH-SCO2 cycle performed by the UTEP research team shows that combustion conditions in the vicinity of 300 bar pressure and 1000-1400 K temperature allow for relatively high system efficiencies while operating within the limit of available combustor materials. However, the realization of a directly heated supercritical power cycle requires combustion systems to operate in supercritical conditions and at temperature far below the blowout limit of conventional flames (above 1500 K). The thermodynamic properties along with the combustion properties and kinetics are unexplored at such conditions. Additionally, the interaction of the supercritical environment with energy components is also unknown. High-pressure combustion tests are performed using a smart burner at some intermediate pressure ranges (<20 bar) to help minimize these knowledge gaps. The knowledge obtained from the high-pressure test will assist in understanding the combustion chamber pressurization mechanism, ignition and flame behavior at the elevated pressure. The obtained data will act as a systematic first step in testing at higher pressures of 100 and 300 bar pressures.The primary purpose of this Dissertation is to demonstrate the operability of a low NOx smart burner for oxy-methane combustion at high pressure (< 20 bar) and scalable up to supercritical conditions. A shear co-axial smart burner is designed with a real-time temperature monitoring capability to understand the burner face interaction at high-pressure conditions. In addition, the burner has four independent injection ports to allow the independent injection of fuel and dilution gases in the combustor. The maximum operating capability of the burner is 575 kWth. The burner was fabricated using a Laser Powder Bed Fusion process with Nickel Alloy 718. A powder removal technology was invented comprising ultrasonic vibration, liquid nitrogen exposure and media blasting to remove powders from internal channels of the burner. The burner operability tests are performed in the high-pressure combustor and the swirl combustor. The high-pressure combustor was used to investigate the burner operability and thermal soak back at different pressurized conditions. The experimental tests in high-pressure combustor up to 275 kWth input resulted in 16.5 bar chamber pressure and 198°C thermal soaks back to the burner. The burner was capable of providing the required thermal input within a 3% deviation range. In addition, soot formation occurred at high-pressure tests. The swirl combustor was used to observe the flame stability of the burner. Flame lift-off was observed for jet velocities above 450 m/s. Additionally, lift-off decreased for low co-flow velocities. CO2 dilution experiments showed increased flame instabilities for all conditions above 50% dilution ratios. At lower thermal inputs, partial flame blow-offs occurred for dilution ratios above 50%. All conditions significantly reduced the flame temperature and increased the flame lift-off height. Finally, a 2nd generation AM smart burner was designed using the knowledge from the 1st generation burner experiments. The 2nd generation burner incorporated two sets of swirlers with 0.9 swirl no. A cooling system was also designed for long-duration tests at higher pressures. The thermal input and division of the burner's power are kept the same as the 1st generation burner. The burner is to be fabricated using nickel-alloy 718 for high-pressure handling capability. The design can sustain at high-pressure conditions up to 100 bar.

Islam, Md Nawshad Arslan↗

Screening aqueous organic redox couples for spontaneous hydrogen generation on catalysts

Two low-cost redox couples with near neutral or alkaline pH - 7,8-dihydroxyphenazine-2-sulfonic acid (DHPS) and chrome chelated ethylenediaminetetraacetic acid (Cr-EDTA) with ammonia – are identified to generate hydrogen evolution spontaneously on Pt/C catalysts. Cr-EDTA redox couple has two times higher hydrogen evolution rate than that of DHPS, and the charged Cr-EDTA molecules are fully utilized to generate hydrogen gas, while ~ 50% of DHPS molecules are utilized to produce hydrogen spontaneously on Pt/C catalysts. The Cr-EDTA electrolyte enables cost reduction by allowing cheap raw material of Cr and corrosion resistant alloy instead of costly superalloy for catalytic reactor systems. Furthermore, the Cr-EDTA with ammonia as a negolyte for flow batteries was validated to suppress hydrogen evolution side reaction, reach 99% of coulombic efficiency in flow cell operation paired with Fe(CN)6 redox couple near neutral pH.

08 HYDROGEN↗

Cost Projections for Utility-Scale Battery Storage (2020 Update)

In this work we describe the development of cost and performance projections for utility-scale lithium-ion battery systems, with a focus on 4-hour duration systems. The projections are developed from an analysis of 19 publications that consider utility-scale storage costs. The suite of publications demonstrates varied cost reductions for battery storage over time. Figure ES-1 shows the low, mid, and high cost projections developed in this work (on a normalized basis) relative to the published values. Figure ES-2 shows the overall capital cost for a 4-hour battery system based on those projections, with storage costs of $\$$144/kWh, $\$$208/kWh, and $\$$293/kWh in 2030 and $\$$88/kWh, $\$$156/kWh, and $\$$219/kWh in 2050. Battery variable operations and maintenance costs, lifetimes, and efficiencies are also discussed, with recommended values selected based on the publications surveyed.

14 SOLAR ENERGY↗

Cost Projections for Utility-Scale Battery Storage: 2021 Update

In this work we describe the development of cost and performance projections for utility-scale lithium-ion battery systems, with a focus on 4-hour duration systems. The projections are developed from an analysis of recent publications that consider utility-scale storage costs. The suite of publications demonstrates varied cost reductions for battery storage over time. Figure ES-1 shows the low, mid, and high cost projections developed in this work (on a normalized basis) relative to the published values. Figure ES-2 shows the overall capital cost for a 4-hour battery system based on those projections, with storage costs of $\$$143/kWh, $\$$198/kWh, and $\$$248/kWh in 2030 and $\$$87/kWh, $\$$149/kWh, and $\$$248/kWh in 2050. Battery variable operations and maintenance costs, lifetimes, and efficiencies are also discussed, with recommended values selected based on the publications surveyed.

25 ENERGY STORAGE↗

Recent advances in metallographic polishing for SRF application

This paper is an overview of the metallographic polishing R\&D program covering Niobium and Copper substrates treatment for thin film coating as an alternative fabrication pathway for 1.3 GHz elliptical cavities. The presented research is the result of a collaborative effort between IJCLab, CEA/Irfu, HZB, and KEK in order to develop innovative surface processing and cavity fabrication protocols capable of meeting stringent requirements for SRF surfaces, including the reduction of safety risks and ecological footprint, enhancing reliability, improving the surface roughness, and potentially allowing cost reduction. The research findings will be disclosed.

Hryhorenko, O.↗

Recent advances in metallographic polishing for SRF application

This paper is an overview of the metallographic polishing R\&D program covering Niobium and Copper substrates treatment for thin film coating as an alternative fabrication pathway for 1.3 GHz elliptical cavities. The presented research is the result of a collaborative effort between IJCLab, CEA/Irfu, HZB, and KEK in order to develop innovative surface processing and cavity fabrication protocols capable of meeting stringent requirements for SRF surfaces, including the reduction of safety risks and ecological footprint, enhancing reliability, improving the surface roughness, and potentially allowing cost reduction. The research findings will be disclosed.

Hryhorenko, O.↗

Enhancement of Optical Efficiency of CSP Mirrors for Reducing O&M Cost via Near-Continuous Operation of Self-Cleaning Electrodynamic Screens (EDS). Final Report

Over the past decade, techno-economical advancements in solar energy systems, particularly the improvement in the conversion efficiency of PV modules made with mono-crystalline silicon solar cells from 12% to 20%, as well as the cost reduction in manufacturing by a factor of about 10%, have made it possible to achieve a levelized cost of electricity (LCOE) in PV plants that is comparable to, or less than, the cost of deriving electricity from fossil fuels. Operating PV plants in mid-latitude sun-belt regions, where the solar irradiance level is highest, provides a high annual energy-yield (kWh/kWp) due to two factors: (1) the availability of predictable high solar irradiance throughout the year with the fewest interruptions in solar flux from clouds and rain, and (2) the increased conversion efficiency of crystalline solar cells, as recombination loss has decreased with increased intensity of the sunlight that illuminates the silicon solar cells. Semi-arid and desert regions, however, are plagued by high atmospheric dust concentrations and frequent sand storms. The deposition of a layer of dust on the optical surfaces of solar collectors such as PV modules and concentrating mirrors reduces the transmission efficiency of sunlight that actually reaches the solar cells or receivers, resulting in high energy-yield soiling loss. There are two major cost components to operating a solar plant: (1) installation costs, and (2) operation-and-maintenance (O&M) costs. There is no fuel cost; hence operating a solar plant in a semi-arid or desert region provides high returns on investment if soiling losses are mitigated via efficient cleaning methods and optimized cleaning frequency. If solar collectors are not cleaned, the accumulation of dust layers on solar collectors may cause the operation of such plants in arid regions to become economically unviable. Washing solar collectors with water and detergent, as is most commonly done now, is an efficient method for cleaning. The conventional approach in utility-scale solar plants is to use a large truck with a water tank and pump system for spraying deionized water on the surface of the solar collectors. Robotic cleaning with brushes, used for many solar plants, requires lesser water for cleaning. The water consumed using semi-automated cleaning of PV modules in utility-scale solar plants is approximately 2 liters/m 2 per cleaning cycle. The total optical surface area of the solar collectors in 1 TW-scale solar installation will be more than 3 × 109 m 2 ; hence an enormous amount of water be needed for cleaning. There simply is not enough fresh water in the sun-belt areas of the world for predicted cleaning needs. In solar power plants, the estimated cost of cleaning solar collectors includes expenses related to the equipment used, labor, cost of transportation of water, the energy required for cleaning, plus ancillary costs whereas the cost of water is not considered. The water used is obtained from sources located close to plant sites, unmindful of the environmental and societal impact as the power plants are oftentimes located in regions that face severe drought. This practice is very similar to the cost calculations in deriving the levelized cost of electricity (LCOE) in conventional power plants based on burning fossil fuel such as coal and gas, while disregarding the cost of climate change and health effects. Unless a water-free or low-water cleaning method is established, the expansion of solar plants may lose public support in areas suffering long intervals of drought. The goal of this research project has been the development and application of the Electrodynamic Screen (EDS) as a means for a water-free, scalable cleaning process applicable to solar-power installations, including rooftop applications. We describe here the development of an EDS film-based cleaning process as an emerging method for use on PV modules, parabolic troughs, and heliostats. This report aims to show the feasibility of integrating or retrofitting EDS films onto the optical surfaces of solar collectors (both PV and CSP) while maintaining high transmission or reflection efficiency. The cleaning action provided by the EDS film is an active method to remove dust deposits by electrodynamic force. Current lab-scale prototype EDS films, retrofitted onto solar panels and mirrors, have shown to be capable of maintaining optical transmission or specular-reflection efficiencies higher than 90% of initial values under clean conditions. The optical surfaces of solar collectors laminated with EDS films can remove more than 90% of deposited dust when the EDS is activated for less than two minutes. As an electrodynamic dust removal process, the EDS film-based method is designed primarily for the removal of dust in solar installations located in semi-arid and desert areas, where the atmosphere is often dry and dusty and rainfall is infrequent. While EDS film application minimizes water consumption and facilitates cleaning as frequently as needed, it has limitations in removing contaminants such as soot, organic pollutants deposited as fine films on the surface, and bird droppings. The dust removal efficiency of the EDS is maximum at relative humidity RH is 40 to 50% and decreases at when RH > 65%. Many solar plant sites undergo diurnal and seasonal cycles of high ambient, early afternoon temperatures and an RH that reaches the dew point early in the morning. These variations in atmospheric conditions do not limit the operation of the EDS film. This report presents a brief review of the progress and the potential of EDS film technology for mitigating the impact of dust on solar collectors via water-free cleaning, as well as current technical challenges regarding efficiency and durability. Our experimental data on the performance of EDS films show that: (1) the dust-removal efficiency (DRE) can reach levels higher than 90%, (2) the specular reflectivity (SR) of EDS film-laminated second-surface mirrors reach levels in excess of 90%, (3) the specular reflectivity restoration (SRR) can exceed 90%, (4) the output-power restoration (OPR) of PV modules can exceed 95%, and (5) the optical transmission efficiency (TE) of the EDS films can be greater than 90%. Working with Sandia National Laboratories (NM), Corning Research and Development Corporation (NY), Eastman Kodak (NY), Tomark-Worthen Industries (NH), and EDS Chile SPA (Chile), we have produced EDS film-laminated PV modules and demonstrated their self-cleaning functions without requiring water. We have demonstrated that the operational range of EDS films will cover the expected ambient temperature of solar fields at RH cycling varying from 20 to 95% as long as the EDS films are activated in the RH range 20 to 50%. (Typical solar-field climates in deserts and semi-arid lands often reach near dew point in coastal areas.) Our experiments on the application of hydrophobic-fluorinated nanoparticle coatings on EDS film surfaces show that the EDS operational range can be extended to higher RH levels that approach the dew point. At Eastman Kodak, as one of our industrial partners, we were able to establish a process for manufacturing EDS films using flexographic printing of the electrodes onto transparent polymer films. This process utilizes an existing manufacturing line at Eastman Kodak that allows fabrication of medium-scale EDS films (26 cm × 30 cm). The manufacturing process has the capacity to produce EDS films at high production speeds. The medium-scale EDS films that have been printed at Kodak were evaluated in the lab at Boston University. The EDS films produced at Kodak were laminated at Tomark-Worthen using an industrial scale vacuum laminator to produce EDS film stacks, which can be affixed onto the optical surfaces of PV modules or concentrating mirrors. The EDS film stack consists of the EDS films that have Willow® Glass (WG) which has a thickness of 100 μm as the front surface. The WG sheets obtained from Corning Research and Development Corporation are customized in size and shape to cover the active area of the EDS films. The back surface of the EDS film stack is integrated onto the optical surface of the solar panel or mirror using optically clear adhesive (OCA) films or silicone adhesives. The OCA films (thickness 25 μm) are produced by 3M. The EDS film stacks have the architecture: WG/OCA/EDS Film/OCA/ over PV module or solar mirror. The power-supply units needed for activating the electrodes of the EDS film were designed and produced at Boston University. These power supply units provide three-phase, 1.2 kV voltage pulses at a very low current (micro-ampere) level and at a low frequency (≈ 5 Hz). The voltage pulses are applied to the electrodes in a sequence such that the train of pulses resembles a unidirectional traveling wave of electrical field on the surface of the EDS film. The dust particles on the surface become charged electrostatically and are levitated by the Coulomb force. The lateral sweeping action of the traveling electric field created by the three-phase voltages pulses then sweeps the dust off the surface. The energy consumed by the EDS electrodes is less than 0.2 Wh/m 2 /cleaning cycle, enabling energy-efficient restoration of output power (OPR) of PV module or specular reflectivity restoration (SRR) for solar mirrors. The EDS system consists of (1) an EDS film stack laminated onto the solar collectors, (2) connection of the EDS film to its power supply unit and (3) Interconnection of the power supply to PV modules or solar mirrors. Design, construction and assessment of field-testing units that have EDS stack laminated PV modules for evaluating the performance of the EDS films in solar fields is being carried out at BU. Our progress under this project, aimed at the advancement of EDS film technology, has reached DOE Technology Readiness Level (TRL) 6. Based on the extensive laboratory evaluations and limited field trials, as well as contacts with potential users, we believe that the technology has reached its commercial stage. We are conducting a cost analysis using the National Renewable Energy Laboratory (NREL) System Advisory Model (SAM) and are preparing for field trials of EDS films in different solar fields in the US, Chile, India and in the Middle East. A brief description of EDS film performance, construction and testing of the field-test unit, autonomous operation of the field-test unit for evaluating EDS performance in increasing energy yield, associated revenue savings, and water conservation is presented.

14 SOLAR ENERGY↗

Cost Projections for Utility-Scale Battery Storage: 2023 Update

In this work we describe the development of cost and performance projections for utility-scale lithium-ion battery systems, with a focus on 4-hour duration systems. The projections are developed from an analysis of recent publications that include utility-scale storage costs. The suite of publications demonstrates wide variation in projected cost reductions for battery storage over time. We use the recent publications to create low, mid, and high cost projections. Projected storage costs are $245/kWh, $326/kWh, and $403/kWh in 2030 and $159/kWh, $226/kWh, and $348/kWh in 2050. Battery variable operations and maintenance costs, lifetimes, and efficiencies are also discussed, with recommended values selected based on the publications surveyed.

25 ENERGY STORAGE↗

ROTA-CAP™: An Intensified Carbon Capture System Using Rotating Packed Beds (Final Scientific/Technical Report)

GTI Energy and Carbon Clean Solutions Limited successfully designed, constructed, and operated an integrated ROTA-CAP carbon capture skid. ROTA-CAP™ is a process intensification technology, applied for post-combustion carbon capture, which utilizes the centrifugal forces generated from rotation of rotating packed beds as well as advanced solvents to achieve increased mass transfer rates 1-2 orders of magnitude higher than conventional columns while substantially decreasing footprint. The test skid, which consisted of a dual stage RPB absorber with external interstage cooling and a single stage RPB regenerator, was operated at capacities up to 0.5 tonne/day of CO 2 capture with flue gas concentrations ranging from 4% to 22% CO 2 by vol. CO 2 removal rates greater than 95% were achieved, with CO 2 product purity also exceeding 95% by vol. Over 1,600 hours of operation were accumulated throughout the project, including over 1,000 hours of operation of the with real flue gas containing at least 9.8% CO 2 by vol. The skid was operated continuously for 24 hours per day and 7 days per week over the course of 7 long-term test campaigns, with the campaigns ranging from approximately 2-4 weeks per campaign. A techno-economic analysis was performed, and a cost of capture of $\$$41.18/tonne CO 2 was calculated for the ROTA-CAP process, compared to $\$$45.75/tonne for a Cansolv-based process. These results show a cost reduction of approximately 10% compared to the Cansolv-based process. Although this still exceeds the target cost of capture of $\$$30/tonne specified for this project, GTI expects that the cost of capture can be further reduced through further optimization of the design and technology. GTI also performed an engineering design review to determine the scale-up potential of the technology, with the results of the preliminary assessment indicating that it appears to be feasible to scale up the RPB technology to 4,000 TPD. It was also determined that both horizontal and vertical rotor orientations are feasible, though there are mechanical advantages to the vertical orientation.

20 FOSSIL-FUELED POWER PLANTS↗

Low-Cost, Dispatch-Constrained Electricity for H2 Production

The presentation, part of the Solar-Derived Hydrogen: Understanding and Implementing the Cost Reduction Drivers Panel at the North America Smart Energy Week 2019, discusses considerations for using low-cost, dispatch-constrained electricity for hydrogen production.

39 EE - Hydrogen and Fuel Cell Technologies (EE-3F↗

Development & Validation of Low-Cost, Highly-Durable, Spinel-Based Materials for SOFC Cathode-Side Contact (Final Report)

A cathode-side contact layer is required to provide and maintain stable electrical conduction paths between the interconnect and cathode in a solid oxide fuel cell (SOFC) stack assembly and thus minimize the ohmic resistance and stack power loss. Current cathode-interconnect contact materials are based on noble metals, electrically-conductive perovskites, their composite materials, etc. These materials are either too expensive or do not possess the overall balanced performance required for the cathode-side contact application. To achieve the DOE SOFC system cost and performance stability goals, a new generation of low-cost, high-performance contact materials needs to be developed. In this project, spinel-based materials thermally converted from the Fe-Ni and Co-Mn based alloy precursors were developed and validated for the cathode-side contact application. The precursor alloy compositions were optimized via a combination of composition screening in the (Ni,Fe) 3 O 4 and (Mn,Co) 3 O 4 spinel system, alloy design using physical metallurgy principles, and cost considerations. The alloy powders with the desired composition and particle size were manufactured via gas atomization. The optimal process parameters for thermal conversion of these alloy precursor layers to a spinel-based layer were identified, i.e., 900°C x 2h in air, which is close to the initial stack firing condition. The area-specific resistances (ASRs) of the interconnect/contact/cathode test assemblies with the developed contact layer were determined for various durations (up to 5000 h) under simulated cathodic operation conditions. Some of the alloy-derived spinel contacts exhibited the lowest ASR and ASR degradation rate. The in-stack performance of the most promising alloy-derived contact layer is currently being evaluated via stack testing. To reduce the stack cost, the Co-Mn based alloy powders were utilized as the precursor for synthesis of dense spinel-based interconnect coating. By optimizing both the initial powder size/distribution and the alloy powder composition, a dense (Mn,Co) 3 O 4 -based spinel coating was achieved. Furthermore, co-sintering of the coating/contact dual-layer structure under the initial stack firing condition was realized by utilizing the tailored Co-Mn alloy precursors. Cost analysis of the developed technology indicated a total stack cost reduction of around 10.6% with the implementation of co-sintering of the interconnect coating and the contact layer during initial stack firing. Since low-cost processes such as screen printing is utilized in the precursor application and no reduction heat treatment is needed for the coating formation, the developed technology can be readily implemented at the industrial partner’s manufacturing facilities with no additional capital investment needed.

08 HYDROGEN↗

Small Reactors in Microgrids: Technology Modeling and Selection (Net-Zero Microgrid Program Project Report)

This report demonstrates the capabilities of the net-zero microgrid (NZM) Xendee platform for modeling an SR module with electricity, heat extraction and thermal storage in microgrids configurations. The model effectively captures the most important technical and economic considerations for SR technology specific analysis: cost and operational characteristics of SR technology and financial costs and incentives. The model can analyze multiple scenarios to establish metrics for cost-competitive and zero-carbon microgrids connected to the grid or completely isolated. The model is fully integrated within the Xendee platform for modeling and analysis of clean energy microgrids with storage and generation from renewable energy sources. The model captures the capabilities, constraints, and nuances of SR by incorporating parameters related to plant economics, design efficiency and performance, plant operation and component and fuel lifespan. The cost and operational parameters modeled in the SR module are specific to the technology selected for integration in the microgrid. Cost parameters recognize advanced nuclear technology for modular production and installation based on economies of scale from factory manufacture and related commissioning, and cost reduction through technology maturation—first-of-a-kind (FOAK) and nth-of-a-Kind (NOAK). The cost parameters include installation, operations and maintenance (O&M), fuel refueling cycle, and reactor life. Installation cost reflects economies of scale due to unit sizing at scale and colocation. O&M economies of scale for both fixed- and variable-cost fuel life-cycle costs are incurred at every refueling interval, with separate front- and back-end fuel costs, as well as waste-handling and disposition costs. This report investigates key characteristics of different SR technologies suitable for microgrid applications, including design principles, sizing, coolant properties, temperature ratings, fuel structures, and life-cycle considerations. This also includes fuel technologies applicable to these SR systems, alongside strategies for nuclear-waste and spent-fuel management and approaches to address safety, security, and proliferation challenges. Four primary groups of SR technologies are examined: water-cooled, liquid-metal-cooled, high-temperature gas-cooled, and molten-salt-cooled systems. In this report, an initial guideline for technology selection is established, aligning the characteristics of the technologies with the requirements of microgrids. The selection of technology in a microgrid is influenced by various factors, including financial capacity, location and accessibility, demand type and characteristics, reliability and resilience requirements, area constraints, and the lifespan of the microgrid. The types of electrical and non-electrical applications within the microgrid also play a significant role in technology selection. The characteristics of SRs, such as their smaller size, modularity, transportability, long refueling interval, improved safety features, ability to operate in autonomous or semi-autonomous mode, and provision of high-grade heat, are particularly appealing for microgrids. Furthermore, a list of considerations for implementing SRs in microgrids is outlined. The SR model is created to be continuously improved with the acquisition of actual data on investment and operational costs, experience with supply chains, production at scale, and field deployments. In the near term, performance data on applications in microgrids will become available from lessons learned from laboratory tests, such as those planned for the Microreactor Applications Research Validation and Evaluation Project (MARVEL), led by Idaho National Laboratory (INL). The SR model incorporates scenario data and known SR design specifications, enabling technoeconomic analysis for SR deployment in microgrids. It specifically considers the distinctive attributes of SRs as generators in technoeconomic studies. SRs can be modeled and analyzed with generation from renewable-energy sources, energy storage, and flexible loads over a range of functionality and applications. This offers a comprehensive tool for feasibility studies, scenario development, and sensitivity analysis for “what-if” consideration of any range of assumptions about SRs in microgrids and other aggregations of distributed-energy resources, including virtual power plants.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗