Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Configurable lighting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

{gamma} spectroscopy around doubly magic {sup 48}Ca by heavy-ion transfer reactions

{gamma} spectroscopy of neutron-rich nuclei around {sup 48}Ca is performed by the heavy-ion transfer reaction {sup 48}Ca on {sup 64}Ni at 282 MeV, with the PRISMA-CLARA setup at Legnaro Laboratory. Angular distributions, polarizations and lifetimes analysis probe spin and parities of several excited states, shading lights on their configuration. In the one neutron transfer channels, {sup 49}Ca and {sup 47}Ca, states arising by coupling a single particle to the 3{sup -} phonon of {sup 48}Ca are observed, showing the robustness of nuclear collectivity in rather light systems. The work demonstrates the feasibility of complete in-beam {gamma}-spectroscopy with heavy-ion transfer reactions and provides a method that can be further exploited in the future with heavy targets and radioactive beams.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Exploratory study of the effects of wing-leading-edge modifications on the stall/spin behavior of a light general aviation airplane

Configurations with full-span and segmented leading-edge flaps and full-span and segmented leading-edge droop were tested. Studies were conducted with wind-tunnel models, with an outdoor radio-controlled model, and with a full-scale airplane. Results show that wing-leading-edge modifications can produce large effects on stall/spin characteristics, particularly on spin resistance. One outboard wing-leading-edge modification tested significantly improved lateral stability at stall, spin resistance, and developed spin characteristics.

Source record↗

Jitter minimization flexure pointing system

The illustrative embodiments provide for a telescope. The telescope includes a housing; an optical assembly disposed inside the housing and configured to gather light from a distant object; and a jitter reduction system connected to the housing. The jitter reduction system includes a first flexure assembly comprising a first base to which is attached to a first armature connected to a first linear motor winding configured to push out a first flexure connected to the first armature and to push out a second flexure connected to the first armature opposite the first flexure, wherein the first flexure and the second flexure have a first normal axis pointing through a center of mass of the optical assembly.

42 ENGINEERING↗

Tracking the Light-Induced Excited-State Dynamics and Structural Configurations of an Extraordinarily Long-Lived Metastable State at Room Temperature

Time-resolved X-ray (Tr-XAS) and optical transient absorption (OTA) spectroscopy in the pico-microsecond time scale coupled with Density Functional theory calculations are applied to study the light-induced spin crossover processes of a Fe-based macrocyclic complex in solution. Tr-XAS analysis after light illumination shows the formation of a seven-coordinated high spin quintet metastable state which relaxes to a six-coordinated high spin configuration before decaying to ground state. Kinetic analysis of the macrocyclic complex reveals an unprecedented long-lived decay lifetime of ~42.6 µs. Comparative studies with a non-macrocyclic counterpart illustrate a significantly shortened ~568-old decay lifetime of ~75 ns, and highlight the importance of the ligand arrangement in stabilizing the reactivity of the excited state. Lastly, OTA analysis shows the seven-coordinated high spin state to be formed within ~6.2 ps. Finally, these findings provide a complete understanding of the spin crossover reaction and relaxation pathways of the macrocyclic complex, and reveal the importance of a flexible coordination environment for their rational design.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ethylene monitoring and control system

A system that can accurately monitor and control low concentrations of ethylene gas includes a test chamber configured to receive sample gas potentially containing an ethylene concentration and ozone, a detector configured to receive light produced during a reaction between the ethylene and ozone and to produce signals related thereto, and a computer connected to the detector to process the signals to determine therefrom a value of the concentration of ethylene in the sample gas. The supply for the system can include a four way valve configured to receive pressurized gas at one input and a test chamber. A piston is journaled in the test chamber with a drive end disposed in a drive chamber and a reaction end defining with walls of the test chamber a variable volume reaction chamber. The drive end of the piston is pneumatically connected to two ports of the four way valve to provide motive force to the piston. A manifold is connected to the variable volume reaction chamber, and is configured to receive sample gasses from at least one of a plurality of ports connectable to degreening rooms and to supply the sample gas to the reactive chamber for reaction with ozone. The apparatus can be used to monitor and control the ethylene concentration in multiple degreening rooms.

Nelson, Bruce N.↗

Ethylene monitoring and control system

A system that can accurately monitor and control low concentrations of ethylene gas includes a test chamber configured to receive sample gas potentially containing an ethylene concentration and ozone, a detector configured to receive light produced during a reaction between the ethylene and ozone and to produce signals related thereto, and a computer connected to the detector to process the signals to determine therefrom a value of the concentration of ethylene in the sample gas. The supply for the system can include a four way valve configured to receive pressurized gas at one input and a test chamber. A piston is journaled in the test chamber with a drive end disposed in a drive chamber and a reaction end defining with walls of the test chamber a variable volume reaction chamber. The drive end of the piston is pneumatically connected to two ports of the four way valve to provide motive force to the piston. A manifold is connected to the variable volume reaction chamber, and is configured to receive sample gasses from at least one of a plurality of ports connectable to degreening rooms and to supply the sample gas to the reactive chamber for reaction with ozone. The apparatus can be used to monitor and control the ethylene concentration in multiple degreening rooms.

Nelson, Bruce N.↗

Recirculating Etalon Spectrometer

Systems, methods, and devices may provide an optical scheme that achieves simultaneous wavelength channels and maintains the resolution and luminosity of an etalon. Various embodiments may provide a method to optically recirculate the light reflected from the etalon back through the same etalon at new angles. Various embodiments create an etalon spectrometer based on angular dispersion without moving parts and without losing the light that is not initially transmitted. Various embodiments may provide a spectrally-resolved receiver and/or transmitter. Various embodiments may provide a system including a retro-reflector, a detector or transmitter array, and an etalon disposed between the retro-reflector and the detector or transmitter array, wherein the retro-reflector is configured to redirect light reflected by the etalon back to the etalon at a different angle of incidence than an original angle of incidence on the etalon of the light reflected by the etalon.

Stephen, Mark A.↗

Development of large volume double ring penning plasma discharge source for efficient light emissions

In this paper, the development of large volume double ring Penning plasma discharge source for efficient light emissions is reported. The developed Penning discharge source consists of two cylindrical end cathodes of stainless steel having radius 6 cm and a gap 5.5 cm between them, which are fitted in the top and bottom flanges of the vacuum chamber. Two stainless steel anode rings with thickness 0.4 cm and inner diameters 6.45 cm having separation 2 cm are kept at the discharge centre. Neodymium (Nd{sub 2}Fe{sub 14}B) permanent magnets are physically inserted behind the cathodes for producing nearly uniform magnetic field of {approx}0.1 T at the center. Experiments and simulations have been performed for single and double anode ring configurations using helium gas discharge, which infer that double ring configuration gives better light emissions in the large volume Penning plasma discharge arrangement. The optical emission spectroscopy measurements are used to complement the observations. The spectral line-ratio technique is utilized to determine the electron plasma density. The estimated electron plasma density in double ring plasma configuration is {approx}2 Multiplication-Sign 10{sup 11} cm{sup -3}, which is around one order of magnitude larger than that of single ring arrangement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact imaging system using a co-linear, high-intensity LED illumination unit to minimize window reflections for background-oriented schlieren, shadowgraph, photogrammetry and machine vision measurements

One aspect of the present disclosure is an imaging system including an optical sensor defining an optical axis. The system further includes a light source. The system may include an optical beam splitter, and may also include an optional diffusing lens that may be configured to diffuse and/or collimate light from the light source and direct light exiting the diffusing lens to the optical beam splitter. The optical beam splitter is configured to direct light from the light source along the optical axis of the optical sensor.

Bathel, Brett F.↗

Photoluminescent nanofiber composites, methods for fabrication, and related lighting devices

A photoluminescent nanofiber composite includes a nanofiber substrate, first luminescent particles, and second luminescent particles. The first luminescent particles are supported by the nanofibers and span at least a portion of a substrate surface, as a layer on the substrate surface, or with some particles located in a bulk of the substrate, or both. The second luminescent particles are disposed on the substrate. The second luminescent particles may be disposed directly on the substrate surface or on the first luminescent particles. The second luminescent particles may be deposited in a pattern of deposition units. The first and second luminescent particles are configured for emitting light of different respective wavelengths in response to excitation by a light beam. One or more surface treatment coatings may be provided at different locations.

36 MATERIALS SCIENCE↗

Tidally Excited Modes and δ Scuti Pulsations in the Eclipsing Triple Star IM Persei

IM Per is a triple star system whose eclipsing pair masses and radii are accurate to within 1%. The Transiting Exoplanet Survey Satellite (TESS) light curve of the program target exhibits partial eclipses and multiple oscillations with millimagnitude-level amplitudes. It is found that the oscillations affect eclipse timing measurements. Binary modeling of the high-quality TESS data indicates that the eclipsing components of the triple system are twin dwarfs with parameters of M {sub 2}/M {sub 1} = 0.995, R {sub 2}/R {sub 1} = 0.901, and Δ(T{sub eff,1}–T{sub eff,2}) = 12 K in an eccentric (e = 0.049), detached configuration. The third light of l {sub 3} = 0.054 may mostly come from a G-type tertiary companion. Our predicted parallax of 1.52 ± 0.09 mas is concurrent with the Gaia measurement of 1.52 ± 0.05 mas. Multifrequency analysis of the outside-eclipse residuals reveals 22 significant pulsation signals: 4 in the gravity-mode region (0.03−2.22 day{sup −1}) and 18 in the pressure-mode region (9.19−25.12 day{sup −1}). Of the low frequencies, f {sub 11} and f {sub 14} are orbital harmonics that can be identified as tidally excited modes. The pulsation periods and constants for the high frequencies, and the position in the Cepheid instability strip demonstrate that the pulsating component of IM Per is a δ Sct variable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ADRIANO2 Calorimeter Performance from 2022 Test Beams

A novel high-granularity dual-readout calorimetric technique was developed as part of the T1604 collaboration. The ADRIANO2 Calorimeter Prototype consists of a pair of optically isolated, small sized tiles made of scintillating plastic and lead glass. Čerenkov light from the lead glass are exploited to for high resolution timing measurements, while high granularity from scintillating plastic can be used to probe the spatial component of the particle shower. This setup works for excellent energy resolution and particle detection for REDTOP as it is crucial for a calorimeter to detect the decay products of eta/eta-prime mesons. Measurements were collected on ADRIANO2 between February to December 2022 to evaluate the detector performance at Fermilab’s Test Beam Facility. The key metrics extracted from my analysis are the detector’s efficiency for various tile configuration and light-yield which will then be used as parameters for an upgraded REDTOP monte-carlo simulation campaign. An in-depth analysis of ADRIANO2 performance are detailed in this presentation.

43 PARTICLE ACCELERATORS↗

Reversible storage of a weak light pulse in a thermal atomic medium

We investigate the storage and retrieval of a weak signal pulse in a medium composed of N {Lambda}-type three-level atoms in thermal motion. Both atomic internal and translational degrees of freedom are treated quantum mechanically, based on which momentum families that are closed with respect to the action of the interaction Hamiltonian are defined. We introduce momentum-dependent collective atomic density operators by sorting the atoms into groups according to their momenta and establish Heisenberg equations for these atomic operators and the signal field. Because of the thermal-motion-dependent dephasing effect in the establishment of electromagnetically induced transparency of the medium, the efficiency of transfer between the signal pulse and the medium is reduced. The numerical simulations show that the performance of the scheme can be improved by applying the copropagation configuration of the light fields and preparing the atoms initially with a small width of the thermal momentum distribution, which is assumed to be the Gaussian function, or in the state where the Raman-Nath approximation is tenable.

74 ATOMIC AND MOLECULAR PHYSICS↗

Doubly heavy baryons in a Salpeter model with AdS/QCD inspired potential

The spectrum of baryons with two heavy quarks is predicted, assuming a configuration of a light quark and a heavy diquark. The masses are computed within a semirelativistic quark model, using a potential obtained in a gauge-gravity (anti-de Sitter/QCD) framework. All the parameters defining the model are determined fitting the meson spectrum. The obtained mass of {xi}{sub cc} is in agreement with the measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving the Visible and Infrared Contrast Ratio of Microshutter Arrays

Three device improvements have been developed that dramatically enhance the contrast ratio of microshutters. The goal of a microshutter is to allow as much light through as possible when the shutters are in the open configuration, and preventing any light from passing through when they are in the closed position. The ratio of the transmitted light that is blocked is defined here as the contrast ratio. Three major components contribute to the improved performance of these microshutters: 1. The precise implementation of light shields, which protect the gap around the shutters so no light can leak through. It has been ascertained that without the light shield there would be a gap on the order of 1 percent of the shutter area, limiting the contrast to a maximum of 100. 2. The precise coating of the interior wall of each microshutter was improved with an insulator and metal using an angle deposition technique. The coating prevents any infrared light that finds an entrance on the surface of the microshutter cell from being emitted from a sidewall. Since silicon is in effect transparent to any light with a wavelength longer than .1 micrometer, these coatings are essential to blocking any stray signals when the shutters are closed. 3. A thin film of molybdenum nitride (MoN) was integrated onto the surface of the microshutter blade. This film provides the majority of light blockage over the microshutter and also ensures that the shutter can be operated over a wide temperature range by maintaining its flatness. These improvements were motivated by the requirements dictated by the James Webb Space Telescope NIRSpec instrument. The science goals of the NIRSpec require observing some of the very faintest objects in a given field of view that also may contain some very bright objects. To observe the faint objects, the light from the bright objects - which could be thousands of times brighter - must be completely blocked. If a closed microshutter is even slightly transmissive, a very bright object will still transmit a small signal, which can be larger than a signal from a very faint object transmitted through an open shutter. Since this situation can completely corrupt the results, it was necessary that the closed shutters be able to attenuate light by at least a factor of 2,000. There currently exist four flight-quality microshutter arrays that have been fully or are currently undergoing testing and the results support that the three improvements described above have successfully led to contrast levels greater than 50,000 in over 99 percent of the microshutters at an operating temperature of 35 K. Applications for these high-contrast microshutters are in the photomask generation and stepper equipment used to make integrated circuits and microelectromechanical (MEMS) devices. Since microshutters are a reconfigurable optical element, their versatility in these industries provides an improvement over printed masks and fixed projection alignment systems.

Jhabvala, Murzy↗

System and method for monitoring integrity of a wellbore

A detector assembly includes scintillators configured to generate a light signal in response to an impinging backscatter signal, where the scintillators are arranged in a first pattern, a plurality of first detectors, where each first detector is coupled to a scintillator and configured to receive a first portion of a light signal from that scintillator, and where the first detectors are arranged in a second pattern aligned with the first pattern, a plurality of second detectors, where each second detector is disposed adjacent a scintillator and configured to receive a second portion of the light signal from that scintillator, and where the plurality of second detectors is arranged in a third pattern, and a scintillator collimator including a plurality of openings and configured to selectively receive the backscatter signal, where the detector assembly is configured to provide depth resolution, azimuthal resolution, a defect type, a defect size, or combinations thereof.

36 MATERIALS SCIENCE↗

Gamma-ray spectroscopic characterization of long, rapidly-grown KSr 2 I 5 :Eu crystals

Collimation and volumetric studies were done to evaluate the gamma-ray spectroscopic performance of KSr 2 I 5 :Eu scintillators grown via the vertical Bridgman method. To demonstrate practical crystal growth for large-scale production, Ø1 in. × 6 in. long crystals were grown using fast pulling rates up to 5 mm/h and short cooling times. The long crystals were sectioned into shorter Ø1 in. cylinders to investigate sample-to-sample variation of scintillation properties, the effects of self-absorption and scintillation non-uniformity using different gamma-ray excitation configurations. The best light output and energy resolution achieved for the largest volume and aspect ratio crystals (60 cm 3 Ø1 in x 4.7 in. long) were 53,500 ph/MeV and 4.6% at 662 keV. Finally, we produced eight Ø1 in. × 1 in. (12.5 cm 3 ) cylindrical samples, four from each boule, with energy resolutions between 3.1%-3.5% at 662 keV.

36 MATERIALS SCIENCE↗