Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Confidence interval”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Thermophysical Properties of GRCop-84

The thermophysical properties and electrical resistivity of GRCop-84 (Cu - 8 at.% Cr-4 at.% Nb) were measured from cryogenic temperatures to near its melting point. The data were analyzed using weighted regression to determine the properties as a function of temperature and assign appropriate confidence intervals. The results showed that the thermal expansion of GRCop-84 was significantly lower than NARloy-Z (Cu-3 wt. % Ag-0.5 wt. % Zr), the currently used thrust cell liner material. The lower thermal expansion is expected to translate into lower thermally induced stresses and increases in thrust cell liner lives between 2X and 41X over NARloy-Z. The somewhat lower thermal conductivity of GRCop-84 can be offset by redesigning the liners to utilize its much greater mechanical properties. Optimized designs are not expected to suffer from the lower thermal conductivity. Electrical resistivity data, while not central to the primary application, show that GRCop-84 has potential for applications where a combination of good electrical conductivity and strength is required.

Ellis, David L.↗

The Characteristic Dimension of Lyman-Alpha Forest Clouds Toward Q0957+561

Far-ultraviolet spectra of the gravitational lens components Q0957+561 A and B were obtained with the Hubble Space Telescope Faint Object Spectrograph to investigate the characteristic dimension of Lyman-alpha forest clouds in the direction of the quasar. If one makes the usual assumption that the absorbing structures are spherical clouds with a single radius, that radius can be found analytically from the ratio of Lyman-alpha lines in only one line of sight to the number in both. A simple power series approximation to this solution, accurate everywhere to better than 1%, will be presented. Absorption lines in Q0957+561 having equivalent width greater than 0.3 A in the observer's frame not previously identified as interstellar lines, metal lines, or higher order Lyman lines were taken to be Ly-alpha forest lines. The existence of each line in this consistently selected set was then verified by its presence in two archival FOS spectra with approximately 1.5 times higher signal to noise than our spectra. Ly-alpha forest lines appear at 41 distinct wavelengths in the spectra of the two images. One absorption line in the spectrum of image A has no counterpart in the spectrum of image B, and one line in image B has no counterpart in image A. Based on the separation of the lines of sight over the redshift range searched for Ly-alpha forest lines, the density of the absorbing clouds in the direction of Q0957+561 must change significantly over a radius R = 160 (+120, -70) h (sup -1) (sub 50) kpc (H (sub 0) 50 h (sub 50) km s (sup -1) kpc (sup -1), q (sub 0) = 1/2). The 95% confidence interval on R extends from (50 950) h (sup -1) (sub 50) kpc.

Dolan, J. F.↗

The Lyman-Alpha Forest in the Lensed Quasar Q0957+561 and the Characteristic Dimension of the Absorbing Clouds

Far-ultraviolet spectra of the gravitational lens components Q0957+561 A and 9 were obtained with the Hubble Space Telescope Faint Object Spectrograph (FOS) at five equally spaced epochs, one every two weeks. We confirm the flux variability of the quasar's Lyman-alpha and 0 VI emission lines reported by Dolan et al. (1995) in IUE spectra. The fluxes in these lines vary on a time scale of weeks in the observer's rest frame, independently of each other and of the surrounding continuum. The individual spectra of each image were co-added to investigate the properties of the Lyman-alpha forest along the two lines of sight to the quasar. Absorption lines having equivalent width W > 0.3 A in the observer's frame not previously identified by Michalitsianos et al. (1997) as interstellar lines, metal lines, or higher order Lyman lines were taken to be Ly-alpha forest lines. The existence of each line in this consistently selected set was then verified by its presence in two archival FOS spectra with -1.5 times higher signal to noise than our co-added spectra. Ly-alpha forest lines with W > 0.3 A appear at 41 distinct wavelengths in the spectra of the two images. one absorption line in the spectrum of image A has no counterpart in the spectrum of image B and one line in image B has no counterpart in image A. Based on the separation of the lines of sight over the redshift range searched for Ly-forest lines, the density of the absorbing clouds in the direction of Q0957+561 must change significantly over a distance R = 160 (+120, -70)/ h(sub 50) kpc in the simplified model where the absorbers are treated as spherical clouds and the characteristic dimension, R, is the radius. (We adopt H(sub 0) = 50 h(sub 50) km/s/ kpc, q(sub 0) = 1/2, and lambda = 0 throughout the paper.) The 95% confidence interval on R extends from (50 - 950)/h(sub 50) kpc We show in the Appendix that the fraction of Ly-alpha forest lines that appear in only one spectrum can be expressed as a rapidly converging power series in 1/r, where r the ratio of the radius of the cloud to the separation of the two lines of sight at the redshift of the cloud. This power series can be rewritten to give r in terms of the fraction of Ly-forest wavelengths that appear in the spectrum of only one image. A simple linear approximation to the solution that everywhere agrees with the power series solution to better than 0.8% for r > 2 is derived in the Appendix.

Dolan, Joseph↗

Thermocouple Calibration and Accuracy in a Materials Testing Laboratory

A consolidation of information has been provided that can be used to define procedures for enhancing and maintaining accuracy in temperature measurements in materials testing laboratories. These studies were restricted to type R and K thermocouples (TCs) tested in air. Thermocouple accuracies, as influenced by calibration methods, thermocouple stability, and manufacturer's tolerances were all quantified in terms of statistical confidence intervals. By calibrating specific TCs the benefits in accuracy can be as great as 6 C or 5X better compared to relying on manufacturer's tolerances. The results emphasize strict reliance on the defined testing protocol and on the need to establish recalibration frequencies in order to maintain these levels of accuracy.

Lerch, B. A.↗

Assessment of SAGE Version 6.1 Ozone Data Quality

The SAGE-II V6.1 ozone retrievals are shown to be of better precision at all levels and to be much more accurate than previous retrievals in the lower stratosphere below 20 km altitude. A filtering procedure for removing anomalous ozone profiles associated with volcanic aerosol/cloud effects and other identified artifacts in V6.1 ozone is described. The agreement between SAGE and ozonesondes in the mean is shown to be approximately 10% down to the tropopause. Relative to the sondes SAGE tends to slightly overestimate ozone (less than 5%) between 15 and 20 km altitude, and systematically underestimates ozone in the troposphere by approximately 30% in the regions between 8 km altitude and 2 km below the tropopause. The precisions (random errors) of SAGE ozone retrievals above 25 km altitude are estimated to be 4% or better; they are a factor of ten worse below 16 km altitude. Linear trends in the differences between coincident SAGE and ozonesondes measurement are generally less than 0.3 %/year and not significantly different from zero in 95% confidence intervals. Compared to V5.96 retrievals, ozone trend differences between 20 and 50 km altitude are approximately 0. 1 %/year, below 20 km altitude the SAGE II trends are more positive by approximately 0.2 %/year. For the 1984-1999 period the SAGE-II shows a localized ozone loss of -0.4(+/- 0.25) %/year (2gigma) in the tropics at 20 km altitude. In the lower stratosphere between 16 and 22 km altitudes, the SAGE shows significant ozone losses in the mid-latitudes in both Hemispheres during the 1979-1999 periods. The ozone trends range from -0.24(+/- 0.18) to -0.77(+/- 0.46) (2sigma)%/year. However in the 1984-1999 period, the downward trends are smaller (-0.07 to - 0.25 %/year) in this altitude range, and the trends in the integrated column from 12 to 17 km altitude in mid-latitudes (35 deg - 60 deg) are not significantly different from zero (0.1 +?- 0.6 (2sigma)%/year). Averaged over the tropics (20 deg S to 20 deg N) the ozone column above 15 km altitude exhibit a trend of -0.12 +/- 0.08 (2sigma)%/year.

Wang, Hsiang J.↗

Response Surface Methods for Spatially-Resolved Optical Measurement Techniques

Response surface methods (or methodology), RSM, have been applied to improve data quality for two vastly different spatial ly-re solved optical measurement techniques. In the first application, modern design of experiments (MDOE) methods, including RSM, are employed to map the temperature field in a direct-connect supersonic combustion test facility at NASA Langley Research Center. The laser-based measurement technique known as coherent anti-Stokes Raman spectroscopy (CARS) is used to measure temperature at various locations in the combustor. RSM is then used to develop temperature maps of the flow. Even though the temperature fluctuations at a single point in the flowfield have a standard deviation on the order of 300 K, RSM provides analytic fits to the data having 95% confidence interval half width uncertainties in the fit as low as +/-30 K. Methods of optimizing future CARS experiments are explored. The second application of RSM is to quantify the shape of a 5-meter diameter, ultra-light, inflatable space antenna at NASA Langley Research Center.

Danehy, P. M.↗

A Tool for Verification and Validation of Neural Network Based Adaptive Controllers for High Assurance Systems

High reliability of mission- and safety-critical software systems has been identified by NASA as a high-priority technology challenge. We present an approach for the performance analysis of a neural network (NN) in an advanced adaptive control system. This problem is important in the context of safety-critical applications that require certification, such as flight software in aircraft. We have developed a tool to measure the performance of the NN during operation by calculating a confidence interval (error bar) around the NN's output. Our tool can be used during pre-deployment verification as well as monitoring the network performance during operation. The tool has been implemented in Simulink and simulation results on a F-15 aircraft are presented.

Gupta, Pramod↗

Cranial diameter pulsations measured by non-invasive ultrasound decrease with tilt

INTRODUCTION: Intracranial pressure (ICP) may play a significant role in physiological responses to microgravity by contributing to the nausea associated with microgravity exposure. However, effects of altered gravity on ICP in astronauts have not been investigated, primarily due to the invasiveness of currently available techniques. We have developed an ultrasonic device that monitors changes in cranial diameter pulsation non-invasively so that we can evaluate ICP dynamics in astronauts during spaceflight. This study was designed to demonstrate the feasibility of our ultrasound technique under the physiological condition in which ICP dynamics are changed due to altered gravitational force. METHODS: Six healthy volunteers were placed at 60 degrees head-up, 30 degrees headup, supine, and 15 degrees head-down positions for 3 min at each angle. We measured arterial blood pressure (ABP) with a finger pressure cuff, and cranial diameter pulsation with a pulsed phase lock loop device (PPLL). RESULTS: Analysis of covariance demonstrated that amplitudes of cranial diameter pulsations were significantly altered with the angle of tilt (p < 0.001). The 95% confidence interval for linear regression coefficients of the cranial diameter pulsation amplitudes with tilt angle was 0.862 to 0.968. However, ABP amplitudes did not show this relationship. DISCUSSION: Our noninvasive ultrasonic technique reveals that the amplitude of cranial diameter pulsation decreases as a function of tilt angle, suggesting that ICP pulsation follows the same relationship. It is demonstrated that the PPLL device has a sufficient sensitivity to detect changes non-invasively in ICP pulsation caused by altered gravity.

NASA Program Biomedical Research and Countermeasur↗

Survival after aortic valve replacement for severe aortic stenosis with low transvalvular gradients and severe left ventricular dysfunction

OBJECTIVE: We sought to assess whether aortic valve replacement (AVR) among patients with severe aortic stenosis (AS), severe left ventricular (LV) dysfunction and a low transvalvular gradient (TVG) is associated with improved survival. BACKGROUND: The optimal management of patients with severe AS with severe LV dysfunction and a low TVG remains controversial. METHODS: Between 1990 and 1998, we evaluated 68 patients who underwent AVR at our institution (AVR group) and 89 patients who did not undergo AVR (control group), with an aortic valve area < or = 0.75 cm(2), LV ejection fraction < or = 35% and mean gradient < or = 30 mm Hg. Using propensity analysis, survival was compared between a cohort of 39 patients in the AVR group and 56 patients in the control group. RESULTS: Despite well-matched baseline characteristics among propensity-matched patients, the one- and four-year survival rates were markedly improved in patients in the AVR group (82% and 78%), as compared with patients in the control group (41% and 15%; p < 0.0001). By multivariable analysis, the main predictor of improved survival was AVR (adjusted risk ratio 0.19, 95% confidence interval 0.09 to 0.39; p < 0.0001). The only other predictors of mortality were age and the serum creatinine level. CONCLUSIONS: Among select patients with severe AS, severe LV dysfunction and a low TVG, AVR was associated with significantly improved survival.

NASA Discipline Cardiopulmonary↗

Impact of left ventricular outflow tract area on systolic outflow velocity in hypertrophic cardiomyopathy: a real-time three-dimensional echocardiographic study

OBJECTIVES: The aim of this study was to use real-time three-dimensional echocardiography (3DE) to investigate the quantitative relation between minimal left ventricular (LV) outflow tract area (A(LVOT)) and maximal LV outflow tract (LVOT) velocity in patients with hypertrophic obstructive cardiomyopathy (HCM). BACKGROUND: In patients with HCM, LVOT velocity should change inversely with minimal A(LVOT) unless LVOT obstruction reduces the pumping capacity of the ventricle. METHODS: A total of 25 patients with HCM with systolic anterior motion (SAM) of the mitral valve leaflets underwent real-time 3DE. The smallest A(LVOT) during systole was measured using anatomically oriented two-dimensional "C-planes" within the pyramidal 3DE volume. Maximal velocity across LVOT was evaluated by two-dimensional Doppler echocardiography (2DE). For comparison with 3DE A(LVOT), the SAM-septal distance was determined by 2DE. RESULTS: Real-time 3DE provided unique information about the dynamic SAM-septal relation during systole, with A(LVOT) ranging from 0.6 to 5.2 cm(2) (mean: 2.2 +/- 1.4 cm(2)). Maximal velocity (v) correlated inversely with A(LVOT) (v = 496 A(LVOT)(-0.80), r = -0.95, p < 0.001), but the exponent (-0.80) was significantly different from -1.0 (95% confidence interval: -0.67 to -0.92), indicating a significant impact of small A(LVOT) on the peak LVOT flow rate. By comparison, the best correlation between velocity and 2DE SAM-septal distance was significantly (p < 0.01) poorer at -0.83, indicating the superiority of 3DE for assessing A(LVOT). CONCLUSIONS: Three-dimensional echocardiography-measured A(LVOT) provides an assessment of HCM geometry that is superior to 2DE methods. These data indicate that the peak LVOT flow rate appears to be significantly decreased by reduced A(LVOT). Real-time 3DE is a potentially valuable clinical tool for assessing patients with HCM.

NASA Discipline Cardiopulmonary↗

Assessment of internal mammary artery and saphenous vein graft patency and flow reserve using transthoracic Doppler echocardiography

OBJECTIVE: To investigate transthoracic Doppler echocardiography in the identification of coronary artery bypass graft (CABG) flow for assessing graft patency. DESIGN: The initial study group comprised 45 consecutive patients with previous CABG undergoing elective cardiac catheterisation for recurrent ischaemia. The Doppler variables best correlated with angiographic graft patency were then tested prospectively in a further 84 patients (test group). SETTING: Three tertiary referral centres. INTERVENTIONS: Flow velocities in grafts were recorded at rest and during hyperaemia induced by dipyridamole (0.56 mg/kg/4 min), under the guidance of transthoracic colour Doppler flow mapping. Findings on transthoracic Doppler were compared with angiography. MAIN OUTCOME MEASURES: Feasibility of identifying open grafts by Doppler and diagnostic accuracy for Doppler detection of significant (>/= 70%) graft stenosis. RESULTS: In the test group the identification rate for mammary artery grafts was 100%, for saphenous vein grafts to left anterior descending coronary artery 91%, for vein grafts to right coronary artery 96%, and for vein grafts to circumflex artery 90%. Coronary flow reserve (the ratio between peak diastolic velocity under hyperaemia and at baseline) of < 1.9 (95% confidence interval 1.83 to 2.08) had 100% sensitivity, 98% specificity, 87.5% positive predictive value, and 100% negative predictive value for mammary artery graft stenosis. Coronary flow reserve of < 1.6 (95% CI 1.51 to 1.73) had 91% sensitivity, 87% specificity, 85.4% positive predictive value, and 92.3% negative predictive value for significant vein graft stenosis. CONCLUSIONS: Transthoracic Doppler can provide non-invasive assessment of CABG patency.

Multicenter Study↗

Comparison of mode estimation methods and application in molecular clock analysis

BACKGROUND: Distributions of time estimates in molecular clock studies are sometimes skewed or contain outliers. In those cases, the mode is a better estimator of the overall time of divergence than the mean or median. However, different methods are available for estimating the mode. We compared these methods in simulations to determine their strengths and weaknesses and further assessed their performance when applied to real data sets from a molecular clock study. RESULTS: We found that the half-range mode and robust parametric mode methods have a lower bias than other mode methods under a diversity of conditions. However, the half-range mode suffers from a relatively high variance and the robust parametric mode is more susceptible to bias by outliers. We determined that bootstrapping reduces the variance of both mode estimators. Application of the different methods to real data sets yielded results that were concordant with the simulations. CONCLUSION: Because the half-range mode is a simple and fast method, and produced less bias overall in our simulations, we recommend the bootstrapped version of it as a general-purpose mode estimator and suggest a bootstrap method for obtaining the standard error and 95% confidence interval of the mode.

Evolution, Molecular↗

Assessment of the time constant of relaxation: insights from simulations and hemodynamic measurements

The objective of this study was to use high-fidelity animal data and numerical simulations to gain more insight into the reliability of the estimated relaxation constant derived from left ventricular pressure decays, assuming a monoexponential model with either a fixed zero or free moving pressure asymptote. Comparison of the experimental data with the results of the simulations demonstrated a trade off between the fixed zero and the free moving asymptote approach. The latter method more closely fits the pressure curves and has the advantage of producing an extra coefficient with potential diagnostic information. On the other hand, this method suffers from larger standard errors on the estimated coefficients. The method with fixed zero asymptote produces values of the time constant of isovolumetric relaxation (tau) within a narrow confidence interval. However, if the pressure curve is actually decaying to a nonzero pressure asymptote, this method results in an inferior fit of the pressure curve and a biased estimation of tau.

NASA Discipline Cardiopulmonary↗

Examination of two methods for statistical analysis of data with magnitude and direction emphasizing vestibular research applications

When the dependent (or response) variable response variable in an experiment has direction and magnitude, one approach that has been used for statistical analysis involves splitting magnitude and direction and applying univariate statistical techniques to the components. However, such treatment of quantities with direction and magnitude is not justifiable mathematically and can lead to incorrect conclusions about relationships among variables and, as a result, to flawed interpretations. This note discusses a problem with that practice and recommends mathematically correct procedures to be used with dependent variables that have direction and magnitude for 1) computation of mean values, 2) statistical contrasts of and confidence intervals for means, and 3) correlation methods.

Vestibule↗

Estimates of volumetric bone density from projectional measurements improve the discriminatory capability of dual X-ray absorptiometry

To determine whether estimates of volumetric bone density from projectional scans of the lumbar spine have weaker associations with height and weight and stronger associations with prevalent vertebral fractures than standard projectional bone mineral density (BMD) and bone mineral content (BMC), we obtained posteroanterior (PA) dual X-ray absorptiometry (DXA), lateral supine DXA (Hologic QDR 2000), and quantitative computed tomography (QCT, GE 9800 scanner) in 260 postmenopausal women enrolled in two trials of treatment for osteoporosis. In 223 women, all vertebral levels, i.e., L2-L4 in the DXA scan and L1-L3 in the QCT scan, could be evaluated. Fifty-five women were diagnosed as having at least one mild fracture (age 67.9 +/- 6.5 years) and 168 women did not have any fractures (age 62.3 +/- 6.9 years). We derived three estimates of "volumetric bone density" from PA DXA (BMAD, BMAD*, and BMD*) and three from paired PA and lateral DXA (WA BMD, WA BMDHol, and eVBMD). While PA BMC and PA BMD were significantly correlated with height (r = 0.49 and r = 0.28) or weight (r = 0.38 and r = 0.37), QCT and the volumetric bone density estimates from paired PA and lateral scans were not (r = -0.083 to r = 0.050). BMAD, BMAD*, and BMD* correlated with weight but not height. The associations with vertebral fracture were stronger for QCT (odds ratio [QR] = 3.17; 95% confidence interval [CI] = 1.90-5.27), eVBMD (OR = 2.87; CI 1.80-4.57), WA BMDHol (OR = 2.86; CI 1.80-4.55) and WA-BMD (OR = 2.77; CI 1.75-4.39) than for BMAD*/BMD* (OR = 2.03; CI 1.32-3.12), BMAD (OR = 1.68; CI 1.14-2.48), lateral BMD (OR = 1.88; CI 1.28-2.77), standard PA BMD (OR = 1.47; CI 1.02-2.13) or PA BMC (OR = 1.22; CI 0.86-1.74). The areas under the receiver operating characteristic (ROC) curves for QCT and all estimates of volumetric BMD were significantly higher compared with standard PA BMD and PA BMC. We conclude that, like QCT, estimates of volumetric bone density from paired PA and lateral scans are unaffected by height and weight and are more strongly associated with vertebral fracture than standard PA BMD or BMC, or estimates of volumetric density that are solely based on PA DXA scans.

Non-NASA Center↗

Psychosocial correlates of immune responsiveness and illness episodes in US Air Force Academy cadets undergoing basic cadet training

This study examined psychosocial correlates of immune function and illness in 89 male first-year US Air Force Academy cadets. A psychosocial questionnaire was administered to cadets prior to their arrival at the academy and was readministered during cadet orientation and during the stressful environment of Basic Cadet Training (BCT). Immune responsiveness was analyzed by PHA-, PMA-, or anti-CD3-stimulated thymidine uptake in mononuclear leucocytes. Illness episodes were assessed via medical chart review and self-reported symptoms. There were significant increases in distress levels as cadets entered BCT. No psychosocial measure assessed prior to arrival at the academy predicted level of PHA-, PMA-, and anti-CD3-stimulated thymidine uptake or risk of illness. However, hostility levels reported during BCT predicted risk of illness in the four weeks following psychosocial assessment (odds ratio = 7.1; 95% confidence interval: 1.4-36.1). Elevated response to environmental stressors and lower well-being levels also predicted impending illness, but only in the cohort of cadets who had not contracted food poisoning prior to assessment during BCT (OR = 9.3, CI = 1.9-46.7; OR = 0.09, CI = 0.02-0.53). These results suggest that self-report measures of hostility, response to environmental stressors and well-being may be useful predictors of impending illness episodes in males encountering high stress environments.

NASA Discipline Regulatory Physiology↗

The anemia of primary autonomic failure and its reversal with recombinant erythropoietin

OBJECTIVE: To determine if chronic sympathetic deprivation is associated with anemia and a low erythropoietin response. DESIGN: Survey of the prevalence and characteristics of anemia in patients with severe primary autonomic failure. SETTING: A referral service for autonomic failure in a tertiary teaching hospital. PATIENTS: 84 patients with primary autonomic failure who had symptomatic orthostatic hypotension. INTERVENTION: Open-label trial with human recombinant erythropoietin. RESULTS: Anemia was present in 32 of 84 patients (38%; 95% Cl, 27% to 50%). Plasma norepinephrine levels, measured in patients standing upright, were lower in the patient group with lower hemoglobin levels. Mean values in 22 patients with a hemoglobin level of less than 120 g/L were as follows: hemoglobin, 108 g/L (range, 87 to 118 g/L); hematocrit, 0.33; corrected reticulocyte counts, 0.008; mean corpuscular volume, 89 fL (89 microns 3); serum iron, 16.5 mumol/L (92 micrograms/dL); total iron binding capacity, 43.3 mumol/L (242 micrograms/dL); ferritin, 184 micrograms/L; serum vitamin B12, 410 pmol/L (556 pg/mL); and serum folate, 22.7 nmol/L (10 ng/mL). No relation was found between serum erythropoietin and blood hemoglobin levels. In seven of nine patients with autonomic failure who had hemoglobin levels less than 120 g/L, serum erythropoietin levels decreased below the 95% confidence interval corresponding to patients with iron deficiency anemia. Therapy with recombinant erythropoietin improved mean hemoglobin levels (from 108 to 133 g/L) in all patients treated (n = 5) at relatively low doses (25 to 50 units/kg body weight, subcutaneously, three times a week). CONCLUSIONS: Our data support the hypothesis that the sympathetic nervous system stimulates erythropoiesis in humans because anemia is a frequent occurrence in patients with severe autonomic failure and is associated with a blunted erythropoietin response.

Clinical Trial↗

bpshape wk4: a computer program that implements a physiological model for analyzing the shape of blood pressure waveforms

We describe the theory and computer implementation of a newly-derived mathematical model for analyzing the shape of blood pressure waveforms. Input to the program consists of an ECG signal, plus a single continuous channel of peripheral blood pressure, which is often obtained invasively from an indwelling catheter during intensive-care monitoring or non-invasively from a tonometer. Output from the program includes a set of parameter estimates, made for every heart beat. Parameters of the model can be interpreted in terms of the capacitance of large arteries, the capacitance of peripheral arteries, the inertance of blood flow, the peripheral resistance, and arterial pressure due to basal vascular tone. Aortic flow due to contraction of the left ventricle is represented by a forcing function in the form of a descending ramp, the area under which represents the stroke volume. Differential equations describing the model are solved by the method of Laplace transforms, permitting rapid parameter estimation by the Levenberg-Marquardt algorithm. Parameter estimates and their confidence intervals are given in six examples, which are chosen to represent a variety of pressure waveforms that are observed during intensive-care monitoring. The examples demonstrate that some of the parameters may fluctuate markedly from beat to beat. Our program will find application in projects that are intended to correlate the details of the blood pressure waveform with other physiological variables, pathological conditions, and the effects of interventions.

Non-NASA Center↗