Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Commercialization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The bioprocess TEA calculator: An online technoeconomic analysis tool to evaluate the commercial competitiveness of potential bioprocesses

Techno-economic analysis connects R&D, engineering, and business. By linking process parameters to financial metrics, it allows researchers to understand the factors controlling the potential success of their technologies. In particular, metabolic and bioprocess engineering, as disciplines, are aimed at engineering cells to synthesize products with an ultimate goal of commercial deployment. As a result it is critical to be able to understand the potential impact of strain engineering strategies and lab scale results on commercial potential. To date, while numerous techno-economic models have been developed for a wide variety of bioprocesses, they have either required process engineering expertise to adapt and/or use or do not directly connect financial outcomes to potential strain engineering results. Despite the clear value of techno-economic analysis, these challenges have made it inaccessible to many researchers. Furthermore, the tool, currently focused on aerobic fermentation processes, can be used to understand the impact of fermentation level metrics on the commercial potential of a bioprocess for the production of a wide variety of organic molecules. Using the calculator, I review the commercially relevant targets for an aerobic bioprocess for the production of diethyl malonate.

59 BASIC BIOLOGICAL SCIENCES↗

Considerations for the Global Commercialization of Floating Offshore Wind Energy

Floating offshore wind (FOW) has the potential to unlock access to wind resources in deep water where fixed-bottom turbines are not feasible, enabling coastal regions around the world to meet growing energy demands. Although fixed-bottom offshore wind is commercially mature, FOW, which may be needed for water deeper than 60 m, must progress in multiple ways to reach full commercial viability. In this Perspective, we examine the status of the global FOW industry's commercial development across three key areas - technical innovation, industrialization and cross-cutting value. Technical innovation has enabled FOW turbines to perform as well as fixed-bottom turbines, with the promise of future cost reductions. However, the complex architecture of FOW turbines, combining floating structures with more than 8,000 electrical and mechanical parts in wind turbines, requires industrialization efforts such as standardization and supply-chain integration to enable commercial project deployment. FOW can potentially offer unique benefits, including reduced environmental impacts and strengthened economic development in coastal regions, through substantial regional economic activity. Successful coordination across these three areas could help to position FOW as a major contributor to a competitive, reliable and resilient global energy system.

17 WIND ENERGY↗

Data for Approximately 15% of Miscanthus Yield is Lost at Current Commercial Cutting Heights in Iowa

Various works have quantitatively characterized the effects of environmental and management factors on Miscanthus x giganteus Greef et Deu ( mxg ) yield and, therefore, anticipated land requirement per unit production. However, little work has addressed the effects of cutting height, which may significantly contribute to the difference between the standing aboveground biomass at harvest (i.e., biological yield) and harvested yield. This study quantitatively characterized the effect of cutting height using a replicated nitrogen trial of a 5-year-old mxg stand in southeast Iowa and related this information to observations of cutting height in nearby commercial fields. Nitrogen fertilizer did not significantly change the relationship of the stem segment mass to length, and overall, a 1-cm stem segment contributes 0.5% of the total stem biomass within the bottom 44 cm of the stem. This results in an average harvest loss of 15% of the aboveground standing biomass when cutting at 30 cm, typically seen in commercial mxg fields in eastern Iowa. Cutting height should be considered when accurately predicting commercial mxg harvest yields and changes in soil organic carbon in a commercial mxg agroecosystem.

Biomass Analytics↗

Data for Yield from Iowa’s first commercial miscanthus fields: implications of spatial variability for productivity and sustainability beyond research plots

This dataset contains biomass yield measurements and associated vegetation index data collected from commercial Miscanthus × giganteus fields in eastern Iowa during the 2022–2023 growing seasons. The data support the analyses presented in the article: “Yield From Iowa's First Commercial Miscanthus Fields: Implications of Spatial Variability for Productivity and Sustainability Beyond Research Plots.” We collected 105 ground-truth biomass samples from four mature commercial fields (>4 years old) covering 92.81 ha. Samples were taken from 3 m² quadrats that were hand-harvested in alignment with commercial harvest timing. Stem biomass (excluding leaves) was weighed, moisture-corrected, and converted to dry-matter yield expressed in Mg DM ha⁻¹. Sampling locations were selected to capture spatial variability visible in aerial imagery and were recorded using RTK GPS. Each biomass observation was paired with vegetation indices derived from high-resolution PlanetScope satellite imagery (3 m resolution). Images were acquired throughout the growing season, and indices were calculated to evaluate their ability to predict end-of-season biomass yield. Statistical and machine learning approaches were used to identify key predictors, and a linear regression model based on end-of-July Green Normalized Difference Vegetation Index (GNDVI) was developed and evaluated. This repository includes the data used in that modeling workflow. Management practices, economic data, full imagery time series, and additional methodological details are described in the associated publication and are not included here. The dataset consists of three comma-separated value (CSV) files: 1. Combine_Groundtruth_Yield_VI_22_23.csv This file contains ground-truth biomass yield measurements and associated key vegetation index values collected during the 2022 and 2023 growing seasons. Rows: 105 observations Columns: Year — Year of observation (2022 or 2023) Field — Field location identifier Sample_number — Unique sample identifier GNDVI_End_Jul — Green Normalized Difference Vegetation Index calculated at end of July GNDVI_End_Aug — Green Normalized Difference Vegetation Index calculated at end of August NDRE_End_Aug — Normalized Difference Red Edge index calculated at end of August Biomass_Stem_Yield_MgDM/ha — Measured stem biomass yield (megagrams dry matter per hectare) 2. trainData_GNDVI.csv This file contains the subset of observations used to train the predictive relationship between July GNDVI and biomass yield. Rows: 76 observations Columns: Unnamed: 0 — Row index retained from the original data processing workflow GNDVI_End_Jul — GNDVI at end of July Stem_Yield_MgDM/ha — Observed stem biomass yield (Mg DM ha⁻¹) 3. testData_GNDVI.csv This file contains the test dataset used to evaluate model performance. Rows: 29 observations Columns: Unnamed: 0 — Row index retained from the original data processing workflow GNDVI_End_Jul — GNDVI at end of July Predicted_Yield_MgDM/ha — Model-predicted stem biomass yield (Mg DM ha⁻¹) Observed_Yield_MgDM/ha — Measured stem biomass yield (Mg DM ha⁻¹)

Potential yield, yield gap, in-field management, y↗

Post-processing of phase change material in a zero-change commercial silicon photonic process

Integration of phase change material (PCM) with photonic integrated circuits can transform large-scale photonic systems by providing non-volatile control over phase and amplitude. The next generation of commercial silicon photonic processes can benefit from the addition of PCM to enable ultra-low power, highly reconfigurable, and compact photonic integrated circuits for large-scale applications. Despite all the advantages of PCM-based photonics, today’s commercial foundries do not provide them in their silicon photonic processes yet. We demonstrate the first-ever electrically programmable PCM device that is monolithically post-processed in a commercial foundry silicon photonics process using a few fabrication steps and coarse-resolution photolithography. These devices achieved 1.4 dB/μm of amplitude switching contrast using a thin layer of 12.5 nm GeSbTe in this work. We have also characterized the reconfiguration speed as well as repeatability of these devices over 20,000 switching cycles. Our solution enables non-volatile photonic VLSI systems that can be fabricated at low cost and high reliability in a commercial foundry process, paving the way for the development of non-volatile programmable photonic integrated circuits for a variety of emerging applications.

Optics↗

Expanding the Scope of Commercial Opportunities for Investor-Owned Electric Utilities

Technological advances and a more engaged customer population are pushing utilities and their regulators towards new strategies that promote growth and transformation. Common to many of these efforts is an interest in expanding the set of profit-generating product and service offerings, hereafter referred to as alternative commercial opportunities, beyond just buying and selling electricity. Prior work has focused on specific categories and types of alternative commercial opportunities and in specific market segments. The report fills an important gap in the literature in two ways. First, we develop a comprehensive taxonomy to categorize the alternative commercial opportunities and provide numerous examples within each category. Second, we identify six issues that regulators may want or need to address when determining if and how investor-owned electric utilities pursue these commercial opportunities. The work is intended to inform regulators and decision-makers about how to navigate these broader reform opportunities, as well as rationalize their response within the context of their state policy strategy and in comparison to their peers in other states.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Practices for Demonstrating Energy Savings from Commercial PACE Projects

Nearly three-fourths of U.S. states have authorized local governments to use voluntary special assessments on commercial properties to finance energy improvements that boost economic development, create jobs, increase property values and advance energy goals. Commercial Property Assessed Clean Energy (C-PACE) financing allows building owners to repay the borrowed capital — from private or public sources — over time using their property as security. Berkeley Lab is supporting the Department of Energy’s Commercial PACE Working Group by developing a series of C-PACE issue briefs. The second brief in this series, Practices for Demonstrating Energy Savings from Commercial PACE Projects, looks at common practices for demonstrating energy savings to support state and local governments that sponsor C-PACE programs and want to track their energy impacts. This brief reviews: -The value proposition and trade-offs of conducting energy impact assessments for C-PACE programs; -Methods to quantify energy savings impacts from energy efficiency building improvements; and -Available resources and tools to support energy impact assessments. C-PACE programs may benefit from energy impact assessments for many reasons, including: -Validating the public benefits of the programs -Demonstrating that C-PACE can deliver participant benefits -Illustrating program impacts on public policy goals -Generating data to help improve program performance Many C-PACE programs are collecting data on project energy savings impacts, and these data can be leveraged to further support decision making and program implementation. Potential drawbacks to energy impact assessments may include added cost and burdens on property owners (e.g., the need to collect building energy consumption data). Where these burdens are considerable, they might slow program uptake. State and local governments can balance the benefits of energy impact assessments with the range of costs and accuracy inherent to available assessment methodologies. Additionally, depending on the policy context in the state or local government, a C-PACE program may be able to leverage existing efforts (e.g., building energy benchmarking programs) to reduce impact assessment costs, align with building owner practices and expectations, and efficiently assess program impact.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Commercial, industrial, and institutional discount rate estimation for efficiency standards analysis: Sector-level data 1998–2021

Underlying each of the Department of Energy’s (DOE’s) federal appliance and equipment energy conservation standards are a set of complex analyses of the projected costs and benefits of regulation. Any new or amended standard must be designed to achieve significant additional energy conservation, provided that it is technologically feasible and economically justified (42 U.S.C. 6295(o)(2)(A)). DOE determines economic justification based on whether the benefits exceed the burdens, considering a variety of factors, including the economic impact of the standard on consumers of the product and the savings in lifetime operating cost compared to any increase in price or maintenance expenses (42 U.S.C. 6295(o)(2)(B)). As part of this determination, DOE conducts a Life-Cycle Cost (LCC) analysis, which models the combined impact of appliance first cost and operating cost changes on a representative commercial building sample in order to identify the fraction of customers achieving LCC savings or incurring net cost at the considered efficiency levels. Thus, the commercial discount rate value(s) used to calculate the present value of energy cost savings within the LCC model implicitly plays a role in estimating the economic impact of potential standard levels. This report provides an in-depth discussion of the commercial discount rate estimation process. It is an update to previous reports on estimating commercial discount rates from firm-level financial data (Fujita, 2016). Major topics covered in this report include: Discount rate estimation methods and rationale; -Data sources used and data limitations; -Discount rate distributions for use in standards analysis; -Discount rate estimation methods and distributions specific to the small business subgroup analysis. Going forward, this report will be updated as data allow and analyses necessitate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SAS4A/SASSYS-1 Commercial Grade Dedication Example Report for a Generic Sodium Pool-Type Fast Reactor Application

In the U.S., a key component of the commercialization of advanced reactors is completion of a license application, which must ultimately be approved by the Nuclear Regulatory Commission (NRC). The approval of the license application by the NRC is contingent on satisfactory demonstration of the design basis and the response of the advanced reactor design to transient and accident scenarios using accepted codes and methods. This report describes the qualification and dedication requirements that the advanced reactor safety analysis system software SAS4A/SASSYS-1 are expected to need to fulfill to be used for sodium-cooled pool-type fast reactor licensing. The qualification and dedication requirements are identified through performance critical characteristics and evaluation model acceptance criteria representative of the advanced reactor design considered for licensing. This document captures, additionally, the verification process developed to demonstrate that the software fulfills the qualification and dedication requirements for a generic sodium-cooled pool-type fast reactor as part of the commercial grade dedication process. Like most software that has primarily existed in the research and development space, the most significant challenge facing SAS4A/SASSYS-1 for use in a licensing framework is the availability of a documentation basis describing the code pedigree. SAS4A/SASSYS-1 has been used for licensing of the fast flux test facility (FFTF) and the JOYO sodium-cooled fast reactor in Japan, as well as the design of the CRBR Plant. However, the historical verification and validation (V&V) activities supporting SAS4A/SASSYS-1 development do not align with modern software quality assurance (SQA) and V&V requirements. Two approaches to use of SAS4A/SASSYS-1 in a commercial licensing framework have been identified: commercial-grade dedication (CGD) and software qualification. The methods and requirements prescribed in the ASME NQA-1-2008/2009 Standard and Regulatory Guide 1.203 on the evaluation model development and assessment process (EMDAP) have been used as guidance to define the CGD and qualification processes, respectively. A qualification and dedication requirements matrix has been developed which utilizes fundamental software verification. In this process, software verification is defined as a software quality process aimed at defining software requirement specifications, developing software design documentation, and performing and documenting acceptance testing of the code against requirements. A key element of software qualification and dedication includes determination of software acceptance with respect to critical characteristics relevant to the functional requirements of the software. To assist with identification of cross-cutting transient phenomena and functional requirements, domestic SFR vendor designs have been reviewed to identify a reference SFR design. For this report, the reference design is defined as a pool-type reactor with metal alloy fuel, a liquid-metal intermediate heat transport system, and passive decay heat rejection systems. Given this reference, a series of high-level cross-cutting phenomena was identified for a general class of single-fault undercooling or reactivity insertion transients that scopes the design basis space, with the goal of assisting with prioritization of documentation development efforts for key transient models in SAS: 1) Reactivity feedback response prior to scram; 2) System-wide thermal inertia; 3) Transition in natural circulation flow regime in heat removal systems; 4) Decay heat generation; 5) Steady-state fuel characterization; 5) Clad/fuel behavior at elevated temperatures; 6) Point kinetics and decay heat; 7) Pump coastdown behavior; 8) Core flow redistribution in loss of forced convection; 9) Pool stratification. As a demonstration of CGD of SAS4A/SASSYS-1 for a sodium pool reactor, a software qualification and dedication gap analysis as it relates to code documentation has been performed. This effort leverages the framework established as part of the SAS4A/SASSYS-1 SQA Program. This CGD demonstration provides a framework that vendors can build upon to demonstrate the applicability of the SAS4A/SASSYS-1 software for licensing a sodium-cooled pool-type fast reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Commercial, industrial, and institutional discount rate estimation for efficiency standards analysis: Sector-level data 1998–2022

Underlying each of the U.S. Department of Energy’s (DOE’s) federal appliance and equipment energy conservation standards are a set of complex analyses of the projected costs and benefits of regulation. Any new or amended standard must be designed to achieve significant additional energy conservation, provided that it is technologically feasible and economically justified (42 U.S.C. 6295(o)(2)(A)). DOE determines economic justification based on whether the benefits exceed the burdens, considering a variety of factors, including the economic impact of the standard on consumers of the product and the savings in lifetime operating cost compared to any increase in price or maintenance expenses (42 U.S.C. 6295(o)(2)(B)). As part of this determination, DOE conducts a life-cycle cost (LCC) analysis, which models the combined impact of appliance first cost and operating cost changes on a representative commercial building sample to identify the fraction of customers achieving LCC savings or incurring net cost at the considered efficiency levels. Thus, the commercial discount rate value(s) used to calculate the present value of energy cost savings within the LCC model implicitly plays a role in estimating the economic impact of potential standard levels. This report provides an in-depth discussion of the commercial discount rate estimation process. It is an update to previous reports on estimating commercial discount rates from firm-level and sector-level financial data (e.g., Fujita, 2021, 2016). Major topics covered in this report include the following: -Discount rate estimation methods and rationale -Data sources used and data limitations -Discount rate distributions for use in standards analysis -Discount rate estimation methods and distributions specific to the small business subgroup analysis A version of this analysis was most recently released in 2022. Going forward, this report will be updated as data allow and analyses necessitate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial, industrial, and institutional discount rate estimation for efficiency standards analysis: Sector-level data 1998–2023

Underlying each of the U.S. Department of Energy’s (DOE’s) federal appliance and equipment energy conservation standards are a set of complex analyses of the projected costs and benefits of regulation. Any new or amended standard must be designed to achieve significant additional energy conservation, provided that it is technologically feasible and economically justified (42 U.S.C. 6295(o)(2)(A)). DOE determines economic justification based on whether the benefits exceed the burdens, considering a variety of factors, including the economic impact of the standard on consumers of the product and the savings in lifetime operating cost compared to any increase in price or maintenance expenses (42 U.S.C. 6295(o)(2)(B)). As part of this determination, DOE conducts a life-cycle cost (LCC) analysis, which models the combined impact of appliance first cost and operating cost changes on a representative commercial building sample to identify the fraction of customers achieving LCC savings or incurring net cost at the considered efficiency levels. Thus, the commercial discount rate value(s) used to calculate the present value of energy cost savings within the LCC model implicitly plays a role in estimating the economic impact of potential standard levels. This report provides an in-depth discussion of the commercial discount rate estimation process relying on the Capital Asset Pricing Model (CAPM) to estimate a business’ cost of equity, and by adding a risk adjustment factor to the risk-free rate associated with long-term U.S. Treasury bonds to estimate their cost of debt. It is an update to previous reports on estimating commercial discount rates from firm-level and sector-level financial data (e.g., Fujita, 2021, 2016). Major topics covered in this report include the following: • Discount rate estimation methods and rationale • Data sources used and data limitations • Discount rate distributions for use in standards analysis • Discount rate estimation methods and distributions specific to the small business subgroup analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Self-Assembling Microgrids for Resilient Distribution Systems of the Future: Implementation in a Commercial DERMS Platform

Microgrids have long provided resilience to critical facilities such as hospitals and military installations, and they are now increasingly being looked at as a building block for future grids to support the energy resilience needs of the grid of the future. State-of-the-art technologies, such as blackstart algorithms using renewable distributed energy resources (DERs) to effectively and seamlessly form microgrids, have been produced by national labs over the years. Their adoption by the utility industry would be critical to reap the most benefits toward energy and climate resilience, and the pathway is via commercialization of these self-assembling microgrid algorithms by integrating them in a commercial product platform. This project brings a national labs team (LLNL, LANL) together with a vendor (Smarter Grid Solutions) to perform proof-of-concept integration of the algorithms into the vendor’s commercial Distributed Energy Resources Management System (DERMS). The project provides a strong pathway to commercialization of the algorithms thereby promoting adoption of resilient microgrid technology by utilities to offer resilience benefits to all customers and especially to disadvantaged and underserved communities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterizing falling particle curtain receivers at commercially relevant scales: Research Performance Progress Report (RPPR-1)

Sandia will construct a cold flow receiver test platform in order to characterize falling particle curtain receivers at commercially relevant scales. While Sandia has extensive experience in R&D of falling particle curtain receivers, most have been at pilot scale and smaller - on the order of 1 MW th with characteristic dimensions of nominally 1-2 m to adequately collect solar energy from the heliostat field at the National Solar Thermal Test Facility (NSTTF). However, scaling up receivers to commercially relevant scales (25 MW th and above) will require a thorough understanding of particle curtain dynamics at larger scales, especially longer drop heights, for design certainty. The goal of this project will be to construct a cold falling particle curtain test rig capable of simulating particle characteristics that are expected in a commercial scale CSP plant, namely the drop height, curtain thickness, and particle mass flow rate (normalized by length of curtain). This will enable data collection on curtain opacity and spread, both of which are correlated to receiver efficiency and reliable construction, for commercially relevant scales. It will also permit validation of numerical models that will enable detailed receiver characterization and design past currently validated scales.

14 SOLAR ENERGY↗

Development of a Western U.S. Fusion Energy Commercialization Hub

Fusion energy, if successfully commercialized and globally adopted, could substantially increase U.S. energy dominance and provide essentially unlimited baseload power for the national grid. It also stands to provide the U.S. with a strong source of economic growth through the 2030s and 2040s, giving the U.S. a new and highly internationally competitive industry for export. Fusion can also provide the increased electrical power generation capacity required to power current and future artificial intelligence (AI) activities. In October 2024, the CleanTech Alliance held a fusion energy commercialization regional hub workshop alongside its annual Seattle Fusion Week conference. The event brought together fusion companies, researchers, economic development experts, federal and state government representatives, and power utilities from the western states of Washington, California, Colorado and Nevada. Attendees discussed the potential of regionally focused commercialization of fusion energy in three pillars: technology, workforce, and economic development. Mel Clark, President & CEO, CleanTech Alliance, and Dr. Javier Garay, Associate Dean for Research and Professor of Mechanical and Aerospace Engineering, at the University of California San Diego (UCSD) and Founding Director of the UCSD Fusion Engineering institute, are co-PIs for this project. The project is sponsored by the U.S. Department of Energy’s Office of Fusion Energy Sciences (FES) through a Field Work Proposal to Pacific Northwest National Laboratory (PNNL) with Karl Mueller as point-of-contact. Chris Ajemian (Principal, Ajemian Consulting, LLC) and Dr. Christopher Keane (Professor of Physics and former Vice-President for Research, Washington State University) co-organized the workshop and were the editors for this report. This report details the current state of the work of the four western states to develop industry-led collaboration with national laboratories, universities, and government at all levels to hasten the commercialization of fusion energy. It provides a summary of fusion energy R&D needs, presents the ideas the attendees at the workshop identified for deepening regional collaboration, and makes findings and recommendations for next steps.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterizing falling particle curtain receivers at commercially relevant scales: Research Performance Progress Report (RPPR-1)

Sandia will construct a cold flow receiver test platform in order to characterize falling particle curtain receivers at commercially relevant scales. While Sandia has extensive experience in R&D of falling particle curtain receivers, most have been at pilot scale and smaller - on the order of 1 MWth with characteristic dimensions of nominally 1-2 m to adequately collect solar energy from the heliostat field at the National Solar Thermal Test Facility (NSTTF). However, scaling up receivers to commercially relevant scales (25 MWth and above) will require a thorough understanding of particle curtain dynamics at larger scales, especially longer drop heights, for design certainty. The goal of this project will be to construct a cold falling particle curtain test rig capable of simulating particle characteristics that are expected in a commercial scale CSP plant, namely the drop height, curtain thickness, and particle mass flow rate (normalized by length of curtain). This will enable data collection on curtain opacity and spread, both of which are correlated to receiver efficiency and reliable construction, for commercially relevant scales. It will also permit validation of numerical models that will enable detailed receiver characterization and design past currently validated scales.

14 SOLAR ENERGY↗

Environmentally Friendly Use of Carbon Ore for Advanced Building Materials for Homes and Commercial Buildings

Through this effort, X-MAT CCC sought to confirm the utility and commercialization potential of carbon-derived building materials (CDBM) technology licensed from our partner, Semplastics. These CDBM products contain at least 52% coal-derived carbon by mass. Including the binders within the resin, the products contain at least 71% carbon by mass overall, meeting a key criterion for DE-FOA-0002185 – Area of Interest (AOI) 5 – Design Research and Development, Validation, and Fabrication of a Prototype Carbon-Based Building. The Phase II project has resulted in a technology demonstrator prototype structure, a detailed design for a carbon-based building, and updated techno-economic analysis (TEA) including detailed market surveys to show the commercial viability of CDBM products. We pursued the following objectives in Phase II: (1) construction of a partial building shell as a technology demonstrator, (2) testing of CDBM products, individually and in assemblies, (3) demonstration of bonding of CDBM and traditional building materials (TBM) in structural applications, (4) production of a detailed design for a carbon-based building, and (5) an update of the TEA that was performed in Phase I. In Phase II, X-MAT CCC and our industry team performed the development and testing needed to improve the maturity of the technology from a Technology Readiness Level (TRL) of 5 to TRL 6. CDBM have been shown by our partner Semplastics to exhibit a number of high-performance characteristics, including high strength (five times the flexure strength of the best commercial brick, and more than twice the compressive strength of construction-grade concrete block), lower density, improved mechanical durability and abrasion resistance, very high temperature stability, and resistance to chemicals, acids, salts, and water. These properties offer significant improvements over conventional building materials. Phase II built upon the work accomplished in Phase I by performing technical and economic research and development to confirm the viability of CDBM as commercial products in various markets. Acknowledgment: This material is based upon work supported by the Department of Energy under Award Number DE-FE0031985.

01 COAL, LIGNITE, AND PEAT↗

Development of National New Construction Weighting Factors for the Commercial Building Prototype Analyses (2008-2022)

The U.S. Department of Energy (DOE) tasked Pacific Northwest National Laboratory (PNNL) with updating commercial building construction weights for the purpose of estimating national and state-by-state energy savings impacts of changes made to various commercial energy codes and standards. A similar activity was last completed by PNNL in 2020 using disaggregate construction volume data acquired from the Dodge Data & Analytics database (formerly McGraw Hill) for the years 2003-2018 (Lei et al, 2020). As time passes, changes in economic and social demand reshape construction volume trends. For the current update, PNNL reviewed the same data source with the latest construction data for the years 2008-2022. For commercial building analyses, PNNL typically uses a suite of 16 prototype buildings simulated in the 19 ASHRAE climate zones with 16 of them present in the United States. The 2008-2022 commercial building weighting factors were derived using the same approach employed to develop the 2003-2018 set (Lei et al, 2020). Applying the construction volume data from the database to the prototypes and climate zones resulted in the following new construction area-based weighting factors. Table ES.1 shows the weighting factors including all building categories found in the database, and Table ES.2 shows the weighting factors normalized to include only buildings represented by the 16 prototypes. Section 3.0 also includes national- and state-level weighting factors by area and building count.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Generalizable Web User Interface for Scalable and Streamlined Deployment of Building Energy Management Systems in Small and Medium-Sized Commercial Buildings

Small and medium-sized commercial buildings (SMCBs) comprise 94% of US commercial buildings yet face significant barriers to implementing building energy management systems despite advances in smart device technology. Existing solutions present critical limitations: cloud-based API solutions simplify deployment but create vendor lock-in constraints; commercial integrated software solutions ensure compatibility via standardized protocols but require substantial cost and technical expertise; open-source IoT platforms offer cost-effective vendor independence but provide insufficient standardized protocol support for commercial building automation. This research presents a generalizable web user interface framework that bridges the gap between evolving smart device capabilities and lagging software infrastructure for SMCBs. The proposed system integrates VOLTTRON open-source middleware with an automated configuration converter that transforms unified specifications written in YAML, a human-readable data-serialization format, into system-specific files, streamlining manual setup processes. The vendor-agnostic architecture supports industry-standard protocols (BACnet and Modbus) and semantic building models while providing adaptive web interfaces that dynamically adjust to various building configurations. Demonstrations through simulation-based testing and a field deployment show automatic interface adaptation across heterogeneous HVAC systems and multizone monitoring. The automated configuration converter also substantially reduces labor-intensive setup.

Chung, Jihoon [ORNL] (ORCID:0000000184880815)↗