A Performance analysis of the Claridge-Culp-Liu dehumidification process: A novel approach for drying moist air based on membrane separation, vacuum compression and sub-atmospheric condensation

This article covers a basic model for analyzing the performance of the Claridge-Culp-Liu dehumidification process. The fundamental process efficiency limit for dehumidification is close to COP Carnot , but for the eight dehumidification cases examined, the limiting or ideal energy use required is 26% to 56% that of a Carnot condensing system as shown in an earlier paper. The model presented in this paper is used to show the membrane system performance reduction caused by finite membrane area, finite water vapor permeance, non-zero air permeance, non-zero system air pressure drop, non-ideal compressors, vacuum pumps, and condensers. The performance of a “conservative” membrane system based on the use of existing components is computed for eight specific conditions along with that of a “target” system that assumes expected component performance after additional future component development. The “conservative” membrane system would use 36% to 66% as much energy as a system with a COP=7 chiller to produce the same dehumidification for the eight cases examined while the “target” system would use 15% to 40% the energy of a system with a COP=7 chiller. In addition to the significant energy reduction over conventional technology, the membrane system offers the advantages of: 1) no HFC refrigerant use; 2) direct isothermal control over humidity ratio setpoint; 3) maximum capacity occurs at design conditions; and 4) system generates pure water extracted from air as a by-product.

42 ENGINEERING↗

A novel hybrid dual-temperature absorption refrigeration system: Thermodynamic, economic, and environmental analysis

The applications of multi-evaporator and low temperature refrigeration systems are growing rapidly, highlighting the necessity of developing new configurations that can be economically and environmentally attractive. In this study, a hybrid dual-evaporator absorption refrigeration system for refrigerating and freezing applications is proposed and evaluated from thermodynamic, economic, and environmental viewpoints. In the proposed system, two compressors were employed between the evaporators and absorbers to increase the absorbers pressure to a higher level. The detailed parametric study results demonstrated that only employing a compressor between the higher temperature evaporator and absorber is beneficial improving the coefficient of performance (COP) significantly. However, the economic results showed that the compressor should be implemented carefully because in most design and operating conditions, the required capital and operating costs outweigh the COP improvement. Under specified design conditions, integrating the second compressor with a pressure ratio of 2.5 significantly increased the COP from 0.404 to 0.624 while it caused an increase in the unit production cost of cooling (UPCC) from $\$0.211$/ton-hr to $\$0.228$/ton-hr. The use of flue gas as a heat input was found to have excellent potential to improve the economic and environmental performance of the system. A detailed comparison with a dual-temperature transcritical carbon dioxide refrigeration cycle from the literature demonstrated that, under similar conditions, the system of this study has a substantially lower UPCC than the system in the literature ($\$0.211$/ton-hr and $\$0.110$/ton-hr for the steam and waste heat driven systems against $\$0.457$/ton-hr). Altogether, the proposed system (with and without the compressor) of this study showed an excellent potential for dual-temperature refrigeration applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrochemically driven phase transformation for high-efficiency heat pumping

To reduce energy consumption and improve energy utilization in space conditioning, advanced heat pumping technologies are needed. The chemical looping heat pump (CLHP) is a promising thermodynamic cycle that has theoretically shown the potential to achieve a cooling coefficient of performance (COP c ) increase of over 20% relative to conventional vapor compression systems. In this paper, the key process of the CLHP is experimentally demonstrated, and the system performance and non-ideal behavior are predicted using the component-level models. The results show the feasibility of electrochemical phase change of a working fluid; the peak COP c was 7.64 with a cooling capacity of 3.6 mW (cooling density of 2.57 W m -2 ) at both sink and source temperature of 23°C based on laboratory experiments. The COP c can theoretically reach up to 13 at a temperature lift of 15°C as long as an electrochemical cell can achieve a greater degree of conversion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Performance Overall Water Splitting Electrocatalysts Derived from Cobalt-Based Metal–Organic Frameworks

The design of active, robust, and nonprecious electrocatalysts with both H 2 and O 2 evolution reaction (HER and OER) activities for overall water splitting is highly desirable but remains a grand challenge. Here in this article, we report a facile two-step method to synthesize porous Co-P/NC nanopolyhedrons composed of CoP x (a mixture of CoP and Co 2 P) nanoparticles embedded in N-doped carbon matrices as electrocatalysts for overall water splitting. The Co-P/NC catalysts were prepared by direct carbonization of Co-based zeolitic imidazolate framework (ZIF-67) followed by phosphidation. Benefiting from the large specific surface area, controllable pore texture, and high nitrogen content of ZIF (a subclass of metal–organic frameworks), the optimal Co-P/NC showed high specific surface area of 183 m 2 g -1 and large mesopores, and exhibited remarkable catalytic performance for both HER and OER in 1.0 M KOH, affording a current density of 10 mA cm -2 at low overpotentials of -154 mV for HER and 319 mV for OER, respectively. Furthermore, a Co-P/NC-based alkaline electrolyzer approached 165 mA cm -2 at 2.0 V, superior to that of Pt/IrO 2 couple, along with strong stability. Various characterization techniques including X-ray absorption spectroscopy (XAS) revealed that the superior activity and strong stability of Co-P/NC originated from its 3D interconnected mesoporosity with high specific surface area, high conductivity, and synergistic effect of CoP x encapsulated within N-doped carbon matrices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Femtosecond laser-induced crystallization of amorphous N-doped Ge{sub 8}Sb{sub 92} films and in situ characterization by coherent phonon spectroscopy

Femtosecond laser-irradiation-induced phase change of amorphous N-doped Ge{sub 8}Sb{sub 92} films is in situ studied by coherent phonon spectroscopy. We have observed that a new coherent optical phonon (COP) mode occurs as laser irradiation fluence reaches certain thresholds, indicating laser-induced phase changes. Additionally, this new phonon mode has also been verified in heat-annealing-crystallized N-doped Ge{sub 8}Sb{sub 92} films, confirming the emergence of laser-irradiation-induced crystallization. By measuring the pump fluence dependence of COP dynamics in laser-crystallized N-doped Ge{sub 8}Sb{sub 92} films, we found that the frequency and lifetime of COP decrease with the increasing of pump fluence, which suggests good crystallinity in laser-crystallized N-doped Ge{sub 8}Sb{sub 92} films. It has also been observed that the crystallization temperature of amorphous N-doped Ge{sub 8}Sb{sub 92} films increases with N-doping content. Our results indicate promising applications of N-doped Ge{sub 8}Sb{sub 92} films in optical phase-change memory devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A nonlinear multi-mode wideband piezoelectric vibration-based energy harvester using compliant orthoplanar spring

In this paper, a nonlinear wideband multi-mode piezoelectric vibration-based energy harvester (PVEH) is proposed based on a compliant orthoplanar spring (COPS), which has an advantage of providing multiple vibration modes at relatively low frequencies. The PVEH is made of a tri-leg COPS flexible structure, where three fixed-guided beams are capable of generating strong nonlinear oscillations under certain base excitation. A prototype harvester was fabricated and investigated through both finite-element analysis and experiments. The frequency response shows multiple resonance which corresponds to a hardening type of nonlinear resonance. By adding masses at different locations on the COPS structure, the first three vibration modes are brought close to each other, where the three hardening nonlinear resonances provide a wide bandwidth for the PVEH. The proposed PVEH has enhanced performance of the energy harvester in terms of a wide frequency bandwidth and a high-voltage output under base excitations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cobalt phosphide based nanostructures as bifunctional electrocatalysts for low temperature alkaline water splitting

Cobalt phosphide based thin films and nanoparticles were prepared by the thermal phosphidation of spinel Co 3 O 4 precursor films and nanoparticles, respectively. CoP films were prepared with overall retention of the Co 3 O 4 nanoplatelet morphology while the spherical/cubic Co 3 O 4 and Ni 0.15 Co 2.85 O 4 nanoparticles were converted to nanorods or nanoparticles, respectively. The inclusion of nickel in the nanoparticles resulted in a 2.5 fold higher surface area leading to higher gravimetric performance. In each case high surface area structures were obtained with CoP as the primary phase. All materials were found to act as effective bifunctional electrocatalysts for both the HER and the OER and compared well to commercial precious metal benchmark materials in alkaline electrolyte. As a result, a symmetrical water electrolysis cell prepared from the CoP-based film operated at a low overpotential of 0.41-0.51 V.

30 DIRECT ENERGY CONVERSION↗

ECC Refrigerator: Develop a system model using electrochemical (ECC) compressor and metal hydride (MH) heat exchangers- FY18 2nd Quarter Milestone Report

This report describes equations for modeling electrochemical compressors and metal hydride heat exchangers. We developed two new component models into the HPDM model library. Two system simulations were conducted, one was a water heating system using LaNi5, and the other was a refrigeration system using V0.85Ti0.1Fe0.05. The simulations demonstrated that COPs of the electrochemical compression systems decreased drastically with increasing the electric current and capacity, due to reduced electrochemical compression efficiency at larger ohm resistance loss. Cyclic loss caused by the metal hydride and heat exchanger mass had a secondary effect on the system efficiency. Elimination of the heat exchanger cyclic loss could enhance the water heating COP of the LaNi5 system by 12% and increase the refrigeration COP of the V0.85Ti0.1Fe0.05 system by 7%.

42 ENGINEERING↗

Improving AHU Performance by Minimizing Approach Temperature, Reducing Air Maldistribution, and Efficiently Handling Sensible and Latent Loads (Phase 1 Interim Final Technical Report)

Residential air handling units (AHUs) have stayed the same in form and efficiency for the past 30+ years, with incremental improvements made to address safety, functionality, and energy-efficiency. The purpose of this research in Phase I, Topic 9a: Next Generation Residential Air Handlers, was to improve AHU performance by minimizing heat exchanger (HX) approach temperature, reducing air maldistribution, and developing alternative system configurations which more efficiently handle sensible and latent loads. In this research Optimized Thermal Systems (OTS) developed, modeled, and evaluated multiple alternative system concepts. A dual vapor compression system separate sensible and latent cooling (SSLC) concept was studied to inform work on alternative concepts and to show best-case performance benefit. System concepts included ejector enhanced vapor compression cycles, desiccant assisted dehumidification, dual evaporator SSLC, and alternative AHU HX configurations. A dual vapor compression system showed COP improvement of 20%, however, required additional components, increased unit size, and increased cost. Two types of ejector enhanced vapor compression cycles with dual evaporators improved system COP by 9 to 11%, and reduced AHU losses by as much as 18%, with design changes limited to the AHU, no unit physical size increase, and a moderate increase to system first cost. Desiccant assisted air-conditioning required increased air flow rate resulting in higher fan power and the desiccant wheel increased sensible heat load leading to increased compressor power and reduced system COP. Dual evaporator cycles were found to degrade performance due to increased expansion losses. Optimized single slab HX designs used in place of the traditional A-coil HX led to 44–49% reduction in aluminum, 47–60% less refrigerant charge, and improved HX velocity distribution.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NRIC EBR-II Test Bed Pre-Conceptual Design Report

Authorized by the Nuclear Energy Innovation Capabilities Act (NEICA), the National Reactor Innovation Center (NRIC) provides private sector technology developers access to strategic infrastructures and assets for commercial nuclear energy research, development, demonstration, and deployment activities. The mission is to support a timely and cost-effective path to the licensing and commercialization of new nuclear energy systems. To meet these needs, NRIC is developing two test beds at Idaho National Laboratory (INL). The ZPPR Test bed (ZTB) and the EBR-II Test bed (ETB). The EBR-II test bed will support the demonstration of systems that operate at less than 10 MWt. The baseline objective is for the EBR-II Dome to act as a safety significant containment structure capable of siting reactors that utilize Safeguards Category 4 material for operations. The major areas addressed in the pre-conceptual design include: • Installation of an access door • Electrical Power • Heat Removal • Ventilation in the Dome • Module handling system Along with the design for ETB a concept of operations (COP) has also been developed. The COP is intended to facilitate a common understanding of ideas, challenges, and issues. As systems continue to evolve in complexity System Engineers and Project Directors will utilize the COP to develop and sustain a common vision of the system for stakeholders.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ZPPR Test Bed (ZTB) Pre-Conceptual Design Report

Authorized by the Nuclear Energy Innovation Capabilities Act (NEICA), the National Reactor Innovation Center (NRIC) provides private sector technology developers access to strategic infrastructures and assets for commercial nuclear energy research, development, demonstration, and deployment activities. The mission is to support a timely and cost-effective path to the licensing and commercialization of new nuclear energy systems. To meet these needs, NRIC is developing two reactor demonstration test beds at Idaho National Laboratory (INL), the ZPPR Test bed (ZTB) and the EBR-II Test bed (ETB). ZTB will support the demonstration of systems that operate at less than 500 kWt. The baseline objective is for the ZPPR Cell to act as a confinement structure capable of siting reactors that utilize Safeguards Category 1 material for operations. The major areas addressed in the pre-conceptual design include: • Installation of an access door • Electrical Power • Heat Removal • Ventilation in the Cell • Reactor Installation Along with the design for ZTB, a concept of operations (COP) has also been developed. The COP is intended to facilitate a common understanding of ideas, challenges, and issues. As systems continue to evolve in complexity System Engineers and Project Directors will utilize and update the COP to develop and sustain a common vision of the system for stakeholders.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Model Predictive Control of HVAC Systems: Implementation and Testing at the University of California, Merced

A Model Predictive Control algorithm was developed for the UC Merced campus chilled water plant. Model predictive control (MPC) is an advanced control technology that has proven successful in the chemical process industry and other industries. The main goal of the research was to demonstrate the practical and commercial viability of MPC for optimization of building energy systems. The control algorithms were developed and implemented in MATLAB, allowing for rapid development, performance, and robustness assessment. The UC Merced chilled water plant includes three water-cooled chillers and a two million gallon chilled water storage tank. The tank is charged during the night to minimize on-peak electricity consumption and take advantage of the lower ambient wet bulb temperature. The control algorithms determined the optimal chilled water plant operation including chilled water supply (CHWS) temperature set-point, condenser water supply (CWS) temperature set-point and the charging start and stop times to minimize a cost function that includes energy consumption and peak electrical demand over a 3-day prediction horizon. A detailed model of the chilled water plant and simplified models of the buildings served by the plant were developed using the equation-based modeling language Modelica. Steady state models of the chillers, cooling towers and pumps were developed, based on manufacturers performance data, and calibrated using measured data collected and archived by the control system. A detailed dynamic model of the chilled water storage tank was also developed and calibrated. Simple, semi-empirical models were developed to predict the temperature and flow rate of the chilled water returning to the plant from the buildings. These models were then combined and simplified for use in a model predictive control algorithm that determines the optimal chiller start and stop times and set-points for the condenser water temperature and the chilled water supply temperature. The report describes the development and testing of the algorithm and evaluates the resulting performance, concluding with a discussion of next steps in further research. The experimental results show a small improvement in COP over the baseline policy but it is difficult to draw any strong conclusions about the energy savings potential for MPC with this system only four days of suitable experimental data were obtained once correct operation of the MPC system had been achieved. These data show an improvement in COP of 3.1% {+-} 2.2% relative to a baseline established immediately prior to the period when the MPC was run in its final form. This baseline includes control policy improvements that the plant operators learned by observing the earlier implementations of MPC, including increasing the temperature of the water supplied to the chiller condensers from the cooling towers. The process of data collection and model development, necessary for any MPC project, resulted in the team uncovering various problems with the chilled water system. Although it is difficult to quantify the energy savings resulting from these problems being remedied, they were likely on the same order as the energy savings from the MPC itself. Although the types of problems uncovered and the level of energy savings may differ significantly from other projects, some of the benefits of detecting and diagnosing problems are expected from the use of MPC for any chilled water plant. The degree of chiller loading was found to be a key factor for efficiency. It is more efficient to operate the chillers at or near full load. In order to maximize the chiller load, one would maximize the temperature difference across chillers and the chilled water flow rate through the chillers. Thus, the CHWS set-point and the chilled water flow-rate can be used to limit the chiller loading to prevent chiller surging. Since the flow rate has an upper bound and the CHWS set point has a lower bound, the chiller loading is constrained and often determined by the chilled water return temperature (CHWR). The CHWR temperature is primarily comprised of warm water from the top of the TES tank. The CHWR temperature falls substantially as the thermocline approaches the top of the tank, which reduces the chiller loading. As a result, it has been determined that overcharging the TES tank can be detrimental to the chilled water plant efficiency. The resulting MPC policy differs from the current practice of fully charging the TES tank. A heuristic rule could possible avoid this problem without using predictive control. Similarly, the COP improvements from the change in CWS set-point were largely captured by a static set-point change by the operators. Further research is required to determine how much of the MPC savings could be garnered through simplified rules (based on the MPC study), with and without prediction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ConocoPhillips Sweeny IGCC/CCS Project

Under its Industrial Carbon Capture and Sequestration (ICCS) Program, the United States (U.S.) Department of Energy (DOE) selected ConocoPhillips Company (ConocoPhillips) to receive funding through the American Recovery and Reinvestment Act (ARRA) of 2009 for the proposed Sweeny Integrated Gasification Combined Cycle (IGCC)/Carbon Capture and Storage (CCS) Project (Project) to be located in Brazoria County, Texas. Under the program, the DOE is partnering with industry to demonstrate the commercial viability and operational readiness of technologies that would capture carbon dioxide (CO{sub 2}) emissions from industrial sources and either sequester those emissions, or beneficially reuse them. The primary objective of the proposed Project was to demonstrate the efficacy of advanced technologies that capture CO{sub 2} from a large industrial source and store the CO{sub 2} in underground formations, while achieving a successful business venture for the entity (entities) involved. The Project would capture 85% of the CO{sub 2} produced from a petroleum coke (petcoke) fed, 703 MWnet (1,000 MWgross) IGCC power plant, using the ConocoPhillips (COP) proprietary and commercially proven E-Gas{trademark} gasification technology, at the existing 247,000 barrel per day COP Sweeny Refinery. In addition, a number of other commercially available technologies would be integrated into a conventional IGCC Plant in a unique, efficient, and reliable design that would capture CO{sub 2}. The primary destination for the CO{sub 2} would be a depleted natural gas field suitable for CO{sub 2} storage ('Storage Facility'). COP would also develop commercial options to sell a portion of the IGCC Plant's CO{sub 2} output to the growing Gulf Coast enhanced oil recovery (EOR) market. The IGCC Plant would produce electric power for sale in the Electric Reliability Council of Texas Houston Zone. The existing refinery effluent water would be treated and reused to fulfill all process water needs. The DOE ICCS program adopts a two-phase approach. During the 7-month Phase 1 period, ConocoPhillips further defined the Project by advancing the preliminary design, permits, and contracts. In addition, ConocoPhillips was developing a Phase 2 renewal application to seek continued DOE funding for the Project's design, construction, and early operations. The DOE and ConocoPhillips entered into a Phase1 Cooperative Agreement (DOE Award Number DE-FE0001859) on November 16, 2009, agreeing to share cost on a 50/50 basis during the Phase 1 period, with a DOE budget of $2,989,174. On April 7, 2010, ConocoPhillips informed the DOE that it would not participate in Phase 2 of the DOE ICCS program. The company believes that enabling legislation and regulations at both the federal and state levels will not be approved and implemented in time to make a final investment decision such that the Project would be substantially constructed by September 30, 2015, the end of the AARA funding period. Considering current price assumptions, the Project would not generate investment level returns. ConocoPhillips elected not to submit a Phase 2 renewal application, which was due on April 16, 2010. This Final Scientific/Technical Report provides an overview of the Project, including highlights and benefits of the proposed carbon capture and storage project scope, sites, and technologies. It also summarizes the work accomplishments during the Phase 1 period from November 16, 2009 to June 16, 2010. Due to ConocoPhillips decision not to submit the Phase 2 renewal application and not to enter into related agreements, certain information regarding the proposed CO{sub 2} storage facility cannot be publicly reported due to confidentiality agreements.

01 COAL, LIGNITE, AND PEAT↗

Consultative Committee for Space Data Systems recommendation for space data system standards: Telecommand. Part 2.1: Command operation procedures

This recommendation contains the detailed specification of the logic required to carry out the Command Operations Procedures of the Transfer Layer. The Recommendation for Telecommand--Part 2, Data Routing Service contains the standard data structures and data communication procedures used by the intermediate telecommand system layers (the Transfer and Segmentation Layers). In particular, it contains a brief description of the Command Operations Procedures (COP) within the Transfer Layer. This recommendation contains the detailed definition of the COP's in the form of state tables, along with definitions of the terms used. It is assumed that the reader of this document is familiar with the data structures and terminology of part 2. In case of conflict between the description of the COP's in part 2 and in this recommendation, the definition in this recommendation will take precedence. In particular, this document supersedes section 4.3.3.1 through 4.3.3.4 of part 2.

Source record↗

Measurement of Trailing Edge Noise Using Directional Array and Coherent Output Power Methods

The use of a directional (or phased) array of microphones for the measurement of trailing edge (TE) noise is described and tested. The capabilities of this method arc evaluated via measurements of TE noise from a NACA 63-215 airfoil model and from a cylindrical rod. This TE noise measurement approach is compared to one that is based on thc cross spectral analysis of output signals from a pair of microphones placed on opposite sides of an airframe model (COP method). Advantages and limitations of both methods arc examined. It is shown that the microphone array can accurately measures TE noise and captures its two-dimensional characteristic over a large frequency range for any TE configuration as long as noise contamination from extraneous sources is within bounds. The COP method is shown to also accurately measure TE noise but over a more limited frequency range that narrows for increased TE thickness. Finally, the applicability and generality of an airfoil self-noise prediction method was evaluated via comparison to the experimental data obtained using the COP and array measurement methods. The predicted and experimental results are shown to agree over large frequency ranges.

Hutcheson, Florence V.↗

Measurement Of Trailing Edge Noise using Directional Array and Coherent Output Power Methods

The use of a directional array of microphones for the measurement of trailing edge (TE) noise is described. The capabilities of this method are evaluated via measurements of TE noise from a NACA 63-215 airfoil model and from a cylindrical rod. This TE noise measurement approach is compared to one that is based on the cross spectral analysis of output signals from a pair of microphones (COP method). Advantages and limitations of both methods are examined. It is shown that the microphone array can accurately measures TE noise and captures its two-dimensional characteristic over a large frequency range for any TE configuration as long as noise contamination from extraneous sources is within bounds. The COP method is shown to also accurately measure TE noise but over a more limited frequency range that narrows for increased TE thickness. Finally, the applicability and generality of an airfoil self-noise prediction method was evaluated via comparison to the experimental data obtained using the COP and array measurement methods. The predicted and experimental results are shown to agree over large frequency ranges.

Hutcheson, Florence V.↗

Effect of long-duration spaceflight on postural control during self-generated perturbations

This report is the first systematic evaluation of the effects of prolonged weightlessness on the bipedal postural control processes during self-generated perturbations produced by voluntary upper limb movements. Spaceflight impacts humans in a variety of ways, one of which is compromised postflight postural control. We examined the neuromuscular activation characteristics and center of pressure (COP) motion associated with arm movement of eight subjects who experienced long-duration spaceflight (3--6 mo) aboard the Mir space station. Surface electromyography, arm acceleration, and COP motion were collected while astronauts performed rapid unilateral shoulder flexions before and after spaceflight. Subjects generally displayed compromised postural control after flight, as evidenced by modified COP peak-to-peak anterior-posterior and mediolateral excursion, and pathlength relative to preflight values. These changes were associated with disrupted neuromuscular activation characteristics, particularly after the completion of arm acceleration (i.e., when subjects were attempting to maintain upright posture in response to self-generated perturbations). These findings suggest that, although the subjects were able to assemble coordination modes that enabled them to generate rapid arm movements, the subtle control necessary to maintain bipedal equilibrium evident in their preflight performance is compromised after long-duration spaceflight.

NASA Discipline Neuroscience↗

Effect of stance width on multidirectional postural responses

The effect of stance width on postural responses to 12 different directions of surface translations was examined. Postural responses were characterized by recording 11 lower limb and trunk muscles, body kinematics, and forces exerted under each foot of 7 healthy subjects while they were subjected to horizontal surface translations in 12 different, randomly presented directions. A quasi-static approach of force analysis was done, examining force integrals in three different epochs (background, passive, and active periods). The latency and amplitude of muscle responses were quantified for each direction, and muscle tuning curves were used to determine the spatial activation patterns for each muscle. The results demonstrate that the horizontal force constraint exerted at the ground was lessened in the wide, compared with narrow, stance for humans, a similar finding to that reported by Macpherson for cats. Despite more trunk displacement in narrow stance, there were no significant changes in body center of mass (CoM) displacement due to large changes in center of pressure (CoP), especially in response to lateral translations. Electromyographic (EMG) magnitude decreased for all directions in wide stance, particularly for the more proximal muscles, whereas latencies remained the same from narrow to wide stance. Equilibrium control in narrow stance was more of an active postural strategy that included regulating the loading/unloading of the limbs and the direction of horizontal force vectors. In wide stance, equilibrium control relied more on an increase in passive stiffness resulting from changes in limb geometry. The selective latency modulation of the proximal muscles with translation direction suggests that the trunk was being actively controlled in all directions. The similar EMG latencies for both narrow and wide stance, with modulation of only the muscle activation magnitude as stance width changed, suggest that the same postural synergy was only slightly modified for a change in stance width. Nevertheless, the magnitude of the trunk displacement, as well as of CoP displacement, was modified based on the degree of passive stiffness in the musculoskeletal system, which increased with stance width. The change from a more passive to an active horizontal force constraint, to larger EMG magnitudes especially in the trunk muscles and larger trunk and CoP excursions in narrow stance are consistent with a more effortful response for equilibrium control in narrow stance to perturbations in all directions.

Non-NASA Center↗