Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Climate Zones”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Impact of system parameters and geospatial variables on the reliability of residential systems with PV and energy storage

A reliable power supply is the foundation of modern society, enabling technologies used to function within a society. Residential systems are places where the end users directly consume power, enabling technologies to sustain life. With the emergence of behind-the-meter resources, the end-users have some control over power supply reliability. The intermittency and variability of these resources impact residential system reliability. In this work, we study the reliability performance of a grid-supplemented residential system with behind-the-meter Distributed Energy Resources(DER) subject to various system parameters and geospatial variables. We propose a multistate reliability model for the behind-the-meter microinverter-based Photo Voltaic (PV) system and integrated inverter-based energy storage (ES) system. A sequential Monte Carlo method is then presented to evaluate the reliability indices for the residential system with behind-the-meter DERs as the main supply and the grid as the backup. The sequential Monte Carlo method is used to analyze the reliability performance of the residential model at the top 100 populous counties of the United States, where actual load and solar irradiance data at the counties is used. In the analysis, the sensitivity of indices to system parameters such as DER size and the sensitivity of the indices to climate zone and gross horizontal irradiation (GHI), which affects the load conditions and the PV output of the residential system, is performed. The analysis results show that the system parameters and the geospatial variables significantly impact the residential system’s reliability. The insights from this analysis will be of immense value to the distribution system planners to provide zone-specific guidelines for DER system sizing and toward the evolution of utility business models. Finally, the methodology developed can be used to extend the analysis to other locations.

14 SOLAR ENERGY↗

Coal-derived conductive pavement for winter de-icing: prototype, modeling, and simulation

Existing pavement de-icing methods result in high installation and maintenance costs, traffic delays, excessive weariness and corrosion, and negative environmental and safety impacts. To overcome these challenges, this paper presents an innovative pathway to designing and constructing smart self-heating pavements using a low-cost coal-char bearing asphalt material. The conductive asphalt incorporates coal char, i.e., a key byproduct of the coal pyrolysis process, into the Stone Mastic Asphalt (SMA) mixture. This asphalt containing coal-derived solid carbon exhibits highly tailorable electrical conductivity, satisfactory mechanical and thermophysical properties, and superior cost-efficiency as compared to other conductive pavement materials. The de-icing performance was also demonstrated by laboratory experiments on a bench-scale prototype. Furthermore, an efficient thermal network model was developed and validated by experiments to investigate the transient thermal behavior and energy performance of the Ohmic heating pavement system. Furthermore, the whole-year energy simulation case studies were conducted on a bridge pavement with an annual energy use of 24.6–1444.8 kWh/m 2 , showcasing its potential in field applications across cool humid, cold humid, and subarctic/arctic climate zones.

42 ENGINEERING↗

A worldwide aerosol phenomenology: Elemental and organic carbon in PM 2.5 and PM 10

Elemental carbon (EC), organic carbon (OC), and particulate matter (PM) concentrations in the inhalable (PM 10 ) and fine (PM 2.5 ) size fractions are measured worldwide, albeit with different analytical methods. These measurements from many researchers were collected and analyzed for Africa, America, Asia, and Europe for 2012–2019. EC/PM, OC/PM, and OC/EC ratios were examined based on region, site type, and season to infer potential sources and impacts. These analyses demonstrate that carbonaceous materials are important PM constituents throughout the world. Mean EC/PM ratios were lowest in PM 10 in Sahelian Africa and Europe (∼0.01), highest (>0.07) in PM 2.5 at urban sites in North America, South America, and Japan. Mean OC/PM ratios were lowest in PM 10 in the Sahel (∼0.06) and in PM 2.5 in China and Thailand (0.10), and highest in central and eastern Europe (∼0.3) and North America (∼0.4). OC/EC ratios were elevated in western and northern Europe, and at regional background sites in North America. EC/PM increased with PM 10 in Thailand, while OC/PM increased with higher PM mass in Thailand, India, and North America, highlighting the specific contribution of carbonaceous aerosols to PM pollution in these regions. At European and North American background sites, OC/EC ratios increased with PM mass. Higher OC/EC ratios in dry periods indicate influence of wildfires, prescribed burns, and secondary aerosol formation. Elevated wintertime EC/PM ratios coincide with residential heating in temperate climate zones.

54 ENVIRONMENTAL SCIENCES↗

Analysis of strategies to meet ASHRAE S241 infectious aerosol control targets by space type and region using EnergyPlus™ simulations

Professional organizations, such as ASHRAE, have recently proposed new voluntary standards for controlling infectious aerosols. Specifically, ASHRAE Standard 241 (S241) defines equivalent clean air targets for a range of space types that can be met through combinations of mitigation measures. This paper seeks to inform the selection of measures by space type and climate zone through building simulations that quantify the impacts of increased outdoor air ventilation; increasing filtration and/or adding germicidal ultraviolet (GUV) in the central heating, ventilation, and air-conditioning (HVAC) systems; or using portable air cleaners (PACs), upper room GUV, or whole room GUV approaches to increase equivalent clean air delivery. The measures are assessed individually and in practical combinations for their ability to meet S241 in four space types (offices, classrooms, dining areas, and healthcare waiting rooms) using prototype buildings modeled using EnergyPlus. The mitigation measures are compared holistically against baseline building operations using metrics for equivalent clean air, energy, and comfort. The results in this study show that single measures can meet S241 for offices with minimal impacts on energy and comfort, while either upper room GUV systems or combinations of measures such as MERV 13 HVAC filtration with PACs are needed to meet S241 for classrooms. The dining area and healthcare waiting room targets cannot be met in this study when assuming design occupancy and MS2 as the challenge agent, even when combining multiple measures together. This paper provides valuable considerations when designing measures to meet S241 for a range of spaces and scenarios.

GUV↗

High-performance windows improve thermal survivability of occupants during cold snaps

Exposure to low indoor air temperature is a major contributor to temperature-related mortality during extreme cold events, especially when power outages disrupt operation of space heating systems. This study explores the impact of high-performance windows on the thermal resilience of residential buildings during extreme cold weather and grid power outages, as well as their long-term benefits through energy efficiency and reduced risk of property damage. Building performance simulations were conducted for reference residential buildings in three construction vintages and two major U.S. cities located in cold climate zones, considering two types of extreme cold events: short and severe, and long and milder. Our research found that even houses compliant with current energy codes struggle to maintain safe indoor temperatures for more than a few hours during power outages, necessitating rapid evacuations. High-performance windows can extend the thermal survivability time by up to 3.8 days within a 7-day cold snap and significantly reduce risk of bursting frozen water pipes, depending on the building’s insulation and infiltration level, cold event severity, and occupant vulnerability. This extended thermal safety time is crucial in scenarios where reduced mobility complicates emergency responses in senior housing. In addition to boosting thermal resilience, upgrading older homes with high-performance windows can reduce heating energy consumption by over 18% and cooling energy by 15%. Our findings highlight the need to incorporate thermal resilience assessments into new designs or major retrofits, including the use of typical and extreme weather scenarios and advanced technologies like high-performance windows.

Krelling, Amanda F↗

A method to generate heating and cooling schedules based on data from connected thermostats

Internet-connected thermostats are a promising new source of temperature and operational data in homes because they record inside temperatures, setpoints, and HVAC runtimes every five minutes. Over 20 million Internet-connected thermostats have already been installed in American homes. Data from about 20,000 connected thermostats were collected and organized by climate zone, number of occupants, floor area, and day type. A method was developed to create up to 40 representative temperature schedules which, together, can more accurately capture the diversity of heating and cooling behaviors. These results are suitable for input into schedules for building energy simulation models. This information enables more realistic simulations of American heating and cooling behavior, leading to more accurate estimates of energy consumption and savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prototype energy models for data centers

Data centers in the United States consume about two percent of the nation’s electricity. Because heat gains from IT equipment drive cooling demand, data centers offer unique opportunities for energy savings. However, no prototype energy model for data centers is available in the suite of existing U.S. Department of Energy’s Commercial Prototype Building Models. Here we present the development of two new data center prototype models and their implementation in OpenStudio and EnergyPlus. The small-size data center model represents a computer room in a building served by computer room air conditioners (CRACs); while the large-sized model represents stand-alone data centers served by computer room air handlers (CRAHs) with a central chiller plant. For each data center model, two levels of IT equipment (ITE) load density were considered, to cover the wide range of IT power density of data centers: 40 and 100 W/ft 2 (430 and 1076 W/m 2 ) for the computer room, and 100 and 500 W/ft 2 (1076 and 5382 W/m 2 ) for the stand-alone data center. All other assumptions, such as building envelope, lighting, HVAC efficiencies and schedules, were based on the minimal requirements of ASHRAE Standard 90.1 at various vintages. We introduced a novel concept of supply and return air approach temperatures to capture the essential effects of non-uniform airflow and temperature distribution in data centers. The approach temperatures were pre-computed by computational fluid dynamics (CFD) simulations for various configurations of ITE loads and airflow containment management in data centers. A new feature was developed in EnergyPlus to implement the approach temperature method. A case study was conducted to demonstrate the use of the data center models. The two data center models cover all U.S. climate zones and can be used to evaluate energy saving measures for data centers, as well as to support development of data center energy efficiency codes and standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The impact of behavioral and geographic heterogeneity on residential-sector carbon abatement costs

Analyses of monetary and emissions savings from residential efficiency upgrades usually neglect behavioral differences between consumers. Variations in behavior are frequently large: 13% of the U.S. population sets thermostats for cooling at 20 °C (68 °F) or lower and 15% at 25.5 °C (78 °F) or higher. Efficiency analyses should account for behavioral heterogeneity as well as variations in climate and housing characteristics. We model energy and economic savings of efficiency upgrades for U.S. single-family detached houses, accounting for differences in thermostat settings, climate zone, fuel prices, and home characteristics. We consider five efficiency interventions: wall insulation, attic insulation, air sealing, high-efficiency furnaces, and high-efficiency air conditioners. Energy and economic savings vary widely by consumer; the average net present value for wall insulation is $3,020 United States Dollar (USD), but considering heterogeneity, it has a 10th percentile value of -$231 and 90th percentile value of $5,000. Neglecting heterogeneity, technology upgrades can be prioritized from lower to higher carbon abatement costs: air conditioners, wall insulation, furnace, air sealing, and attic insulation. Accounting for heterogeneity reorders this prioritization, and consumer-specific conditions affect mitigation costs such that technologies are mixed in with one another and are no longer arranged one after another. These results indicate that interventions to improve efficiency should consider differences between consumers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Phase Change Plaster/Paste Composites for Building Envelopes

Thermal energy storage (TES) materials increase a building’s thermal mass and provide the flexibility to shave and time-shift energy use. These materials are needed to enable grid-interactive efficient buildings, allowing building occupants to lower costs by leveraging free ambient heating/cooling as well as shifting consumption to cheaper electricity periods. Phase change materials (PCMs) that store heat through a solid-liquid/solid-solid transformation are of particular interest for TES because of their ability to store large amounts of energy across a constant temperature or very small temperature range. Furthermore, previous studies on PCM building envelopes evaluated products that may only be incorporated as part of new construction and are not easily applicable to existing, energy-intensive buildings. In this work, we leverage laboratory PCM characterization and whole-building energy simulation to study the energy and cost savings of PCM plaster/paste coatings, which can be applied post construction to both new builds and retrofits of existing buildings (about 40% of residential buildings in the United States fall into the retrofit category). We evaluated the energy impact of PCM plaster/paste composites for a single-family residential building in the United States, including layer design (location and thickness), composite properties (phase change temperature, energy density, and shape of the enthalpy curve), and U.S. climate zone. The enthalpy curve shape of PCM shows that phase change temperature and energy density are not the only two parameters that must be considered for PCM selection. Maximizing the energy density amid the effective TES zone is key to boosting energy savings. We also studied PCM price targets with the aim of achieving reasonable payback periods based on both block and time-of-use electricity rates. Moreover, we developed an empirical equation to provide a rough estimate of the energy savings potential of incorporating PCM without the need to perform detailed simulations. These results will help guide the selection and design of PCM plaster/paste composite elements for residential building envelopes.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Performance evaluation of underground thermal storage integrated dual-source heat pump systems

The increasing demand for electricity stresses the existing electric grids. Buildings consume 73% of all U.S. electricity and are responsible for 30% of U.S. greenhouse gas emissions. Integrating thermal energy storage (TES) in building heating/cooling systems, which consume considerable electricity, can mitigate the challenges to electric grids. Here, this study reports on a novel thermal energy storage device integrated heat pump system to reshape the building electricity demand profile while maintaining thermal comfort. The annual performance of the proposed system has been evaluated through a dynamic system simulation with high fidelity in the Modelica platform. The dynamic model of the novel hybrid component named ‘dual purpose underground thermal battery’ was developed and validated. It was then incorporated into the system model. Given a time-of-use tariff, a rule-based control strategy was designed to shift the electric demand and switch the heat pump source for a typical single-family house in different climate zones of the United States. The system performance of the new TES-integrated dual-source heat pump was compared with that of a conventional air-source heat pump system. The results indicate that the proposed system can reduce the annual HVAC electricity cost by up to 52% while saving 45.2% on electricity consumption. In the Northern areas, the annual peak load of the HVAC system can be reduced by 64.9%. However, this reduction is less in the Southern areas as the system’s higher efficiency in winter dominates the overall energy-saving potential.

25 ENERGY STORAGE↗

Shedding light on U.S. small and midsize data centers: Exploring insights from the CBECS survey

As demand for digital services accelerates, the energy and environmental footprint of data centers faces increasing scrutiny. While hyperscale cloud facilities have driven efficiency gains, small and midsize U.S. data centers remain a critical yet underexamined segment with significant untapped potential for energy savings. This study leverages data from the Commercial Buildings Energy Consumption Survey (CBECS) to analyze trends in server stocks, computing customers, cooling system adoption and efficiency, and geospatial distribution from 2012 to 2018. Findings reveal a sharp decline in small and midsize data centers, from 1.764 million to 1.398 million, with server counts dropping from 5.177 million to 4.262 million—aligning with the broader shift toward cloud computing. More than 40 % of servers in small data centers and 55 % in midsize data centers are housed in office buildings, and over half of all servers are concentrated in climate zones 5A (cold), 3A (mixed-humid), and 4A (mixed-humid), with the highest densities in metropolitan hubs. While direct expansion units remain the dominant cooling system, a clear transition toward more energy-efficient solutions, particularly air economizers, is evident. By integrating server and cooling system distributions, we estimate Power Usage Effectiveness (PUE) and Water Usage Effectiveness (WUE) for U.S. data centers by size and year. Results show that midsize data centers are more energy-efficient but more water-intensive due to the widespread use of water-cooled chillers. These findings highlight the trade-offs in cooling system selection and provide a critical foundation for policies aimed at enhancing efficiency in an evolving data center landscape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Benefits of Dual Fuel Heat Pump Grid-responsive Control: A Model-based Control Optimization Approach Using Building and Equipment Co-simulation

Conventional dual fuel heat pumps lack the intelligent control mechanisms to efficiently manage the switch between heat pump and furnace, leading to sub-optimal energy usage and, in some cases, increased operating costs. To resolve this gap, this study applies optimized control on hybrid heat pumps. With a focus on equipment control strategies, we compare the performances of five spacing heating equipment, including a conventional heat pump (HP), a conventional furnace, a dual fuel heat pump (DFHP) with conventional control, a dual fuel heat pump with smart control, and a novel seamlessly fuel flexible heat pump (SFFHP). While DFHP runs on either gas or electricity at any given moment, SFFHP concurrently consumes gas and electricity by continuously optimizing the proportion of each. In this research, a co-simulation framework is developed by integrating a building envelope model with a physics-based heat pump simulation model to analyze the benefits of grid-responsive controls of DFHP and SFFHP. The model-based optimal controls adjust the operation of the heat pump and gas furnace based on utility price signals and marginal grid emission to minimize utility cost and CO 2 emissions for multiple climate zones, different utility tariffs, and marginal grid emission scenarios. Case studies in Chicago and Los Angeles demonstrate that SFFHP and DFHP, with model-based optimal control, can deliver significant reductions in peak demand, utility cost, and CO 2 emission. In Chicago, SFFHP and smart controlled DFHP yield up to 64.7% and 61.7% utility cost reduction and up to 15.7% and 8.5% CO 2 emission reduction compared to the gas furnace. In Los Angeles, SFFHP and smart controlled DFHP achieve up to 43.6% and 40.1% utility cost reduction and up to 13.8% and 14.1% CO2 emission reduction compared to conventional heat pumps. In conclusion, by leveraging the fuel flexibility nature of dual fuel heat pumps, the model-based control optimization approach makes dual fuel heat pump an attractive option for demand response programs.

Control↗

Experimental characterization and potential energy savings of insulated cladding for U.S. residential buildings

This study evaluates a novel insulated cladding composed of foamed cement and vinyl siding that is designed as a retrofit product to enhance thermal performance in U.S. residential buildings. Experimental measurements showed that foamed cement exhibits a thermal conductivity of 0.0334–0.0365 W/m-K (R-value of 4.0–4.3 °F⋅ft 2 ⋅h/BTU), which is significantly higher than that of conventional fiber cement boards. Although mechanical testing confirmed the material’s brittleness and low strength, it also indicated its suitability for nonstructural insulation applications. Water vapor permeability testing demonstrated effective moisture resistance with the polymer coating. To evaluate the insulated cladding’s energy performance, we used the U.S. Department of Energy’s prototype single-family building model and simulated across 50 locations spanning 16 International Energy Conservation Code climate zones. The R-7 (R-value of 7 °F⋅ft 2 ⋅h/BTU per inch) retrofit cladding resulted in heating energy savings up to 275 therms (Fairbanks, AK) and cooling energy savings up to 1,547 kWh (Phoenix, AZ). The energy cost savings varied by region, but the highest annual cost savings ($\$$434/year) were observed in Santa Maria, CA, and the highest annual cost savings percentage (37 %) were noted in Monterey, CA. On a national scale, the insulated retrofit provided an average annual energy cost reduction of 16 %, highlighting the cladding system’s broad applicability and financial viability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Surrogate model evaluation and building energy benchmarking for commercial buildings

Building energy consumption benchmarking involves challenges associated with various energy patterns for different building types; heating, ventilating, and air-conditioning (HVAC) system types; and climates. Given significant variation in energy use patterns, accurate prediction of long-term energy use using surrogate models remains challenging. Multiple linear regression (MLR) is commonly used for building energy benchmarking because of its simple structure; however, it lacks accuracy compared to other black-box models. Although many studies have compared surrogate models and offer guidance on model selection based on metrics, they do not provide detailed analysis on improving the surrogate model accuracy. In this paper, we implement a surrogate model using polynomial ridge regression (i.e., MLR with interaction terms combined with ridge regularization) for small office and retail strip mall buildings across six HVAC system types and all climate zones, for electricity and natural gas in baseline and proposed scenarios. A simulation workflow is developed using OpenStudio TM /EnergyPlus TM to generate simulation data using measures over a wide range of efficiency inputs. Enhancements based on statistical insights are used for improving the model accuracy using filters, input transformations, and change points. Surrogate models achieved average coefficient of variation of the root mean squared error (CVRMSE) values of 2.17, 1.06, 2.05, and 3.26 for proposed electricity, proposed natural gas, baseline electricity, and baseline natural gas, respectively, with enhancements reducing CVRMSE by an average of 14.9% across all combinations. We provide model interpretation via Shapley additive explanations to determine which input variables most influence energy consumption and provide supportive arguments for enhancements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An approach for fast and accurate simulation of phase change material based thermal energy storage in buildings

Latent heat thermal energy storage (LHTES) has significant potential for mitigating peak electricity demand and enabling load shifting in buildings. Phase Change Material embedded heat exchangers (PCM-HX) can significantly improve energy demand management due to high storage capacity. However, PCM-HX evaluation typically depends on computationally expensive fully transient simulations, posing significant challenges for scalable system- and building-level energy assessments across different climates and system architectures. This paper presents a generalized, accurate, and computationally efficient methodology for simulating building energy systems integrated with LHTES. The PCM-HX transient performance is represented by performance maps generated using a Generalized Resistance-Capacitance Model (GRCM) that enables accurate predictions of arbitrary PCM-HXs at low computational cost. The feasibility of the proposed approach was verified using a case study considering a dual-mode heat pump-thermal energy storage (HP-TES) system simulated in Modelica with Spawn of EnergyPlus™ for a DOE prototype small office building in two locations: Tampa, FL, and International Falls, MN. The PCM-HX performance maps provided accurate predictions of PCM-HX transient behavior, with mean absolute percentage deviations within 2–4% compared to GRCM while also achieving at least 1800× reduction in computational time. Moreover, the HP-TES system achieved energy savings of up to 17.4% in Tampa, FL, and 62.2% in International Falls, MN, demonstrating the broader applicability of the proposed methodology across different climate zones. This work highlights the importance of robust PCM-HX models in enabling accurate and computationally efficient building-level simulations and enabling future research opportunities for investigating optimized HP-TES designs and advanced control strategies for grid-interactive buildings.

Modelica↗

Forest aboveground biomass estimation through integration of sentinel-2 and PALSAR-2 time series: assessing models trained on GEDI and field inventory benchmarks

Accurate and spatially explicit forest Aboveground Biomass (AGB) mapping through remote sensing is critical for quantifying terrestrial carbon stocks and informing effective forest management strategies. However, AGB estimation in dense forests with complex terrain remains challenging due to satellite sensor signal saturation problem (saturation issue occurs in high biomass forests), structural complexity, and limited ground truth for calibration. This study presents a novel framework that integrates multi-temporal Sentinel-2 optical imagery, ALOS PALSAR-2 Synthetic Aperture Radar (SAR) data, and topographic variables with explainable Machine Learning to map AGB across mountainous forests within subtropical and temperate oceanic climate zones of Mexico. We evaluate the effects of temporal granularity and sensor synergy by comparing multiple temporal inputs and sensor configurations (Sentinel-2, PALSAR-2, and their fusion), and assess model performance using two reference datasets: NASA GEDI LiDAR-derived biomass and Mexico’s National Forest and Soil Inventory (INFyS). Our results showed that models trained on INFyS consistently outperformed those trained on GEDI, highlighting limitations in GEDI’s reliability in biomass estimates within this study region. Furthermore, the integration of Sentinel-2 and PALSAR-2 provided improved predictions compared to single-sensor models, particularly when combined with temporally explicit yearly statistics. The best-performing model, which was trained on INFyS data, and considered both Sentinel-2 and PALSAR-2 yearly statistics, as well as topographic variables, achieved an R2 of 0.64, RMSE of 51.10 Mg/ha, and relative RMSE (rRMSE) of 58.69%. Explainable ML analysis identified Sentinel-2 spectral indices and topographic features as key predictors, while PALSAR-2 metrics provided complementary information, partially mitigating saturation effects in high-biomass areas. Specifically, integrating both sensors substantially improved AGB estimation in high biomass forest (≥200 Mg/ha), yielding 98% gains over optical-only model, with resulting estimates exceeding GEDI L4B by 29% and ESA-CCI-BIOMASS by 174%. Terrain-stratified analysis indicated close agreement with GEDI in low-slope areas, with increasing divergence as slope steepness increased, while estimates remained consistently higher than ESA-CCI-BIOMASS across all slope classes. The proposed approach advances multi-sensor fusion and temporal feature engineering for AGB mapping using open-access satellite datasets, providing a scalable and reproducible framework for annual biomass monitoring in topographically complex mountainous forests. The resulting 25 m resolution biomass product has the potential to provide spatially detailed information for forest monitoring and may support applications in carbon accounting and forest management.

54 ENVIRONMENTAL SCIENCES↗

The water use of data center workloads: A review and assessment of key determinants

The global importance of data center water use is increasing with the rapid growth of digitalization and artificial intelligence. This study analyzes the factors influencing workload-level water use, measured in liters consumed per workload, to guide water-saving strategies in data centers. Our findings reveal workload-level water use variations exceeding 10,000-fold, driven by over 1000-fold differences in water consumption per kilowatt hour of server electricity consumed and approximately 10-fold differences in server workload efficiency. Key determinants are ranked as server efficiency, electrical grid water consumption factors, server utilization, cooling system type, infrastructure efficiency, climate zone, inactive server percentage, and server refresh cycle. Notably, there is no single recipe for minimizing water use; instead, optimal outcomes depend on tailored combinations of these factors. This analysis addresses critical knowledge gaps by identifying the determinants of data center water use and exploring their achievable minima under diverse site-specific constraints.

Data centers↗

Sub-Ambient Performance of Potassium Sarcosinate for Direct Air Capture Applications: CO 2 Flux and Viscosity Measurements

Absorption based direct air capture (DAC) technologies have garnered significant interest in recent years due to their scalability, competitive regeneration energy requirements, and low susceptibility to degradation. One of the key advantages of DAC lies in its flexible siting options and the potential to utilize low-value land. However, most of the research in this field has been focused on ambient climate zones (T > 20 °C), overlooking sub-ambient (–30 °C < T < 20 °C) regions, which comprise approximately 70 % of the Earth’s surface. To fully realize the potential of DAC, it is essential to understand how DAC solvents perform in these sub-ambient conditions before any large-scale deployment can be considered. Among DAC solvents of interest, potassium sarcosinate (K-SAR) has emerged as a promising candidate due to its high CO 2 capacity, fast uptake kinetics, compatibility with contactor packing materials, low volatility, good thermal and oxidative stability, and competitive regeneration energy requirements compared to current industry standards. This paper characterizes the CO 2 flux and viscosity of K-SAR at sub-ambient conditions and explores the potential of using ethylene glycol and triethylene glycol as additives to prevent solvent freezing in DAC applications. For 1 M K-SAR, the CO 2 flux ranges between 1.3 × 10 -5 and 8.0 × 10 -5 mol m –2 s –1 across a temperature range of –5 °C to 45 °C. Ethylene glycol is shown to effectively suppress the freezing point of K-SAR below –30 °C with volumetric loadings of the additive as low as 0.1. Here, a reaction model was developed to predict the CO 2 flux for 1 M K-SAR at different temperatures, demonstrating good agreement between experimental and theoretical fluxes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗