Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Circulating Water System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Latent Heating from TRMM Satellite Measurements

Rainfall production is the fundamental variable within the Earth's hydrological cycle because it is both the principal forcing term in surface water budgets and its energetics corollary, latent heating, is the principal source of atmospheric diabatic heating. Latent heat release itself is a consequence of phase changes between the vapor, liquid, and frozen states of water. The properties of the vertical distribution of latent heat release modulate large-scale meridional and zonal circulations within the tropics - as well as modifying the energetic efficiencies of midlatitude weather systems. This paper focuses on the retrieval of latent heat release from satellite measurements generated by the Tropical Rainfall Measuring Mission (TRMM) satellite observatory, which was launched in November 1997 as a joint American-Japanese space endeavor. Since then, TRMM measurements have been providing an accurate four-dimensional account of rainfall over the global tropics and sub-tropics, information which can be used to estimate the space-time structure of latent heating across the Earth's low latitudes. The paper examines how the observed TRMM distribution of rainfall has advanced an understanding of the global water and energy cycle and its consequent relationship to the atmospheric general circulation and climate via latent heat release. A set of algorithm methodologies that are being used to estimate latent heating based on rain rate retrievals from the TRMM observations are described. The characteristics of these algorithms and the latent heating products that can be generated from them are also described, along with validation analyses of the heating products themselves. Finally, the investigation provides an overview of how TRMM-derived latent heating information is currently being used in conjunction with global weather and climate models, concluding with remarks intended to stimulate further research on latent heating retrieval from satellites.

Tao, Wei-Kuo↗

New Improved Horizontal Electropolishing System for SRF Cavities

The best performance of niobium SRF accelerating cavities is obtained with surfaces smoothed with electropolishing chemical finishing. Jefferson Lab has recently specified, procured, installed, and commissioned a new versatile production electropolishing (EP) tool. Experience with EP research and operations at JLab as well as vendor interactions and experience guided development of the system specification. Detailed design and fabrication was awarded by contract to Semiconductor Process Equipment Corporation (SPEC). The delivered system was integrated into the JLab chemroom infrastructure and commissioned in 2020. The new EP tool provides much improved heat exchange from the circulating H₂SO₄/HF electrolyte and also the cavity via variable temperature external cooling water flow, resulting in quite uniform cavity wall temperature control and thus improved removal uniformity. With the JLab infrastructure, stabilized process temperature as low as 5 C is available. We describe the system and illustrate operational modes in this contribution.

Reece, C. E.↗

Flightweight radiantly and actively cooled panel: Thermal and structural performance

A 2- by 4-ft flightweight panel was subjected to thermal/structural tests representative of design flight conditions for a Mach 6.7 transport and to off-design conditions simulating flight maneuvers and cooling system failures. The panel utilized Rene 41 heat shields backed by a thin layer of insulation to radiate away most of the 12 Btu/ft2-sec incident heating. A solution of ethylene glycol in water circulating through tubes in an aluminum-honeycomb-sandwich panel absorbed the remainder of the incident heating (0.8 Btu/sq ft-sec). The panel successfully withstood (1) 46.7 hr of radiant heating which included 53 thermal cycles and 5000 cycles of uniaxial inplane loading of + or - 1200 lfb/in; (2) simulated 2g-maneuver heating conditions and simulated cooling system failures without excessive temperatures on the structural panel; and (3) the extensive thermal/structural tests and the aerothermal tests reported in NASA TP-1595 without significant damage to the structural panel, coolant leaks, or hot-gas ingress to the structural panel.

Shore, C. P.↗

Tropical Rainfall Measuring Mission

Tropical rainfall affects the lives and economics of a majority of the Earth's population. Tropical rain systems, such as hurricanes, typhoons, and monsoons, are crucial to sustaining the livelihoods of those living in the tropics. Excess rainfall can cause floods and great property and crop damage, whereas too little rainfall can cause drought and crop failure. The latent heat release during the process of precipitation is a major source of energy that drives the atmospheric circulation. This latent heat can intensify weather systems, affecting weather thousands of kilometers away, thus making tropical rainfall an important indicator of atmospheric circulation and short-term climate change. Tropical forests and the underlying soils are major sources of many of the atmosphere's trace constituents. Together, the forests and the atmosphere act as a water-energy regulating system. Most of the rainfall is returned to the atmosphere through evaporation and transpiration, and the atmospheric trace constituents take part in the recycling process. Hence, the hydrological cycle provides a direct link between tropical rainfall and the global cycles of carbon, nitrogen, and sulfur, all important trace materials for the Earth's system. Because rainfall is such an important component in the interactions between the ocean, atmosphere, land, and the biosphere, accurate measurements of rainfall are crucial to understanding the workings of the Earth-atmosphere system. The large spatial and temporal variability of rainfall systems, however, poses a major challenge to estimating global rainfall. So far, there has been a lack of rain gauge networks, especially over the oceans, which points to satellite measurement as the only means by which global observation of rainfall can be made. The Tropical Rainfall Measuring Mission (TRMM), jointly sponsored by the National Aeronautics and Space Administration (NASA) of the United States and the National Space Development Agency (NASDA) of Japan, provides visible, infrared, and microwave observations of tropical and subtropical rain systems.The satellite observations are complemented by ground radar and rain gauge measurements to validate satellite rain estimation techniques. Goddard Space Flight Center's involvement includes the observatory, four instruments, integration and testing of the observatory, data processing and distribution, and satellite operations. TRMM has a design lifetime of three years. Data generated from TRMM and archived at the GDAAC are useful not only for hydrologists, atmospheric scientists, and climatologists, but also for the health community studying infectious diseases, the ocean research community, and the agricultural community.

Source record↗

Solar hot water system installed at Day's Inn Motel, Dallas, Texas (Valley View)

The solar system was designed to provide 65 percent of the total domestic hot water (DHW) demand. A liquid (water) flat plate collector (1,000 square feet) system automatically drains into the 1,000 gallon steel storage tank when the solar pump is not running. Heat is transferred from the DHW tanks through a shell and tube heat exchanger. A circulating pump between the DHW tanks and heat exchanger enables solar heated water to help make up standby losses. All pumps are controlled by differential temperature controllers.

Source record↗

Atmospheric wind energization of ocean weather

Ocean weather comprises vortical and straining mesoscale motions, which play fundamentally different roles in the ocean circulation and climate system. Vorticity determines the movement of major ocean currents and gyres. Strain contributes to frontogenesis and the deformation of water masses, driving much of the mixing and vertical transport in the upper ocean. While recent studies have shown that interactions with the atmosphere damp the ocean’s mesoscale vortices O(100) km in size, the effect of winds on straining motions remains unexplored. Here, we derive a theory for wind work on the ocean’s vorticity and strain. Using satellite and model data, we discover that wind damps strain and vorticity at an equal rate globally, and unveil striking asymmetries based on their polarity. Subtropical winds damp oceanic cyclones and energize anticyclones outside strong current regions, while subpolar winds have the opposite effect. A similar pattern emerges for oceanic strain, where subtropical convergent flow is damped along the west-equatorward east-poleward direction and energized along the east-equatorward west-poleward direction. These findings reveal energy pathways through which the atmosphere shapes ocean weather.

54 ENVIRONMENTAL SCIENCES↗

The role of large-scale atmospheric circulation in the formation of temperature anomalies in surface waters as illustrated by the northern part of the Pacific Ocean

One important reason for thermal anomalies in the ocean is the dynamic action of anomalous wind systems that set masses of surface water in motion; predominant longitudinal transport of water and air leads to a significant redistribution of cold and warm waters. Heat exchange between the ocean and atmosphere plays an additional role in the formation of water temperature anomalies.

Sorkina, A. I.↗

Dust Tolerant EVA-Compatible Connectors

The objectives of this project are to develop connectors (quick disconnects and umbilical systems) that can be repetitively and reliably mated and de-mated during Lunar surface extra-vehicular activities. These standardized interfaces will be required for structural integrity and commodities transfer between linked surface elements. QD's fittings are needed for EVA spacesuit Primary Life Support Systems as well as liquid cooled garment circulation and suit heat rejection. Umbilical electro-mechanical systems (connectors) are needed between discrete surface systems for transfer of air, power, fluid (water), and data must be capable of being operated by extra vehicular astronaut crew members and/or robotic assistants. There exists an urgent need to prevent electro-statically charged dust and debris from clogging and degrading the interface seals and causing leakage and spills of hazardous commodities, contaminating the flowstream, and degrading the mechanisms needed for umbilical connection. Other challenges include modularity, standardization, autonomous operation, and lifetime sealing issues.

Mueller, Robert P.↗

Preliminary Design of Reactor Cavity Cooling System for a Horizontal Compact HTGR

The Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed MIGHTR in 3 years and support its commercialization as a safe and low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. This report documents the preliminary design study of the RCCS for the HC-HTGR. It includes the establishment of the design requirements, a high-level design study by initial scoping calculations, and preliminary performance calculations of the HC-HTGR RCCS design. Design requirements for the HC-HTGR RCCS have been established to guide preliminary design activities and scoping performance calculations. Initial scoping calculations including estimation of the water inventory, estimation of HVAC thermal capability, and a parametric study on loop dimensions by standalone RCCS analysis. Based on scoping calculation results, a set of baseline dimensions of the HC-HTGR RCCS was derived. A water panel modeling approach was investigated to explore various potential design options for the water panel under consideration for the HC-HTGR RCCS using RELAP5-3D. A test case study was performed to assess the prediction capability of two modeling approaches. The results were compared with CFD simulations conducted in constant RPV temperature and heat flux boundary conditions. It confirms the capability of the RELAP5-3D modeling approach to include all important heat transfer mechanisms expected in the HC-HTGR RCCS operation conditions. Then, a reference RELAP5-3D model for the 1/8 th of a compartment of the preliminary design of the HC-HTGR RCCS was developed. A preliminary performance analysis was conducted to evaluate single-phase natural circulation performance with different top tank temperature values and panel conduction performance in various operation conditions. From single-phase natural circulation performance analysis, the system operation mode was investigated in normal operating and limiting design conditions. It showed operation mode in a subcooled state with a proper top tank water cooling system. Parasitic heat loss by both internal air flow and RCCS was estimated, showing it satisfies maintaining below target maximum heat loss of the HC-HTGR RCCS. From the panel conduction performance analysis, two candidate materials for the riser tube such as carbon steel and stainless steel were compared in the thermal performance of HC-HTGR RCCS. From a single water panel test compared with CFD simulation results, it was confirmed that the current capability of the RELAP5-3D modeling approach for the water panel predicts the thermal conduction of two different materials of the water panel. Then, system-level thermal performance analysis was performed for 1/8 th of the compartment of the preliminary HC-HTGR RCCS design. It was first observed that the current preliminary HC-HTGR RCCS design had minimal impact on the overall thermal performance of the water panel by changing pipe material from carbon steel to stainless steel. From Argonne’s effort on the ongoing water-based NSTF testing program, several considerations other than the thermal performance point of view were addressed to be considered in selecting pipe materials.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nimbus 7 SMMR Derived Seasonal Variations in the Water Vapor, Liquid Water and Surface Winds over the Global Oceans

Monthly mean distributions of water vapor and liquid water contained in a vertical column of the atmosphere and the surface wind speed were derived from Nimbus Scanning Multichannel Microwave Radiometer (SMMR) observations over the global oceans for the period November 1978 to November 1979. The remote sensing techniques used to estimate these parameters from SMMR are presented to reveal the limitations, accuracies, and applicability of the satellite-derived information for climate studies. On a time scale of the order of a month, the distribution of atmospheric water vapor over the oceans is controlled by the sea surface temperature and the large scale atmospheric circulation. The monthly mean distribution of liquid water content in the atmosphere over the oceans closely reflects the precipitation patterns associated with the convectively and baroclinically active regions. Together with the remotely sensed surface wind speed that is causing the sea surface stress, the data collected reveal the manner in which the ocean-atmosphere system is operating. Prominent differences in the water vapor patterns from one year to the next, or from month to month, are associated with anomalies in the wind and geopotential height fields. In association with such circulation anomalies the precipitation patterns deduced from the meteorological network over adjacent continents also reveal anomalous distributions.

Prabhakara, C.↗

Coupling Mars' Dust and Water Cycles: Effects on Dust Lifting Vigor, Spatial Extent and Seasonality

The dust cycle is an important component of Mars' current climate system. Airborne dust affects the radiative balance of the atmosphere, thus greatly influencing the thermal and dynamical state of the atmosphere. Dust raising events on Mars occur at spatial scales ranging from meters to planet-wide. Although the occurrence and season of large regional and global dust storms are highly variable from one year to the next, there are many features of the dust cycle that occur year after year. Generally, a low-level dust haze is maintained during northern spring and summer, while elevated levels of atmospheric dust occur during northern autumn and winter. During years without global-scale dust storms, two peaks in total dust loading were observed by MGS/TES: one peak occurred before northern winter solstice at Ls 200-240, and one peak occurred after northern winter solstice at L(sub s) 305-340. These maxima in dust loading are thought to be associated with transient eddy activity in the northern hemisphere, which has been observed to maximize pre- and post-solstice. Interactive dust cycle studies with Mars General Circulation Models (MGCMs) have included the lifting, transport, and sedimentation of radiatively active dust. Although the predicted global dust loadings from these simulations capture some aspects of the observed dust cycle, there are marked differences between the simulated and observed dust cycles. Most notably, the maximum dust loading is robustly predicted by models to occur near northern winter solstice and is due to dust lifting associated with down slope flows on the flanks of the Hellas basin. Thus far, models have had difficulty simulating the observed pre- and post- solstice peaks in dust loading. Interactive dust cycle studies typically have not included the formation of water ice clouds or their radiative effects. Water ice clouds can influence the dust cycle by scavenging dust from atmosphere and by interacting with solar and infrared radiation, thereby modifying the thermal structure of the atmosphere and its circulation. Results presented in other papers at this workshop show that including the radiative effects of water ice clouds greatly influence the water cycle and the vigor of weather systems in both the northern and southern hemispheres. Our goal is to investigate the effects of fully coupling the dust and water cycles on the dust cycle. We show that including water ice clouds and their radiative effects greatly affect the magnitude, spatial extent and seasonality of dust lifting and the season of maximum atmospheric dust loading.

Kahre, M. A.↗

A Conceptual Design of the Reactor Cavity Cooling System for the Horizontal Compact High Temperature Gas Reactor (HC-HTGR)

Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed HC-HTGR in 3 years and support its commercialization as a safe, low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. This report documents the design study to derive a conceptual design study of the RCCS for the HC-HTGR. It includes the identification of the functions and requirements of the HC-HTGR RCCS, design analyses including high-level design consideration and the calculations for optimizing design space of the system with supporting component-level analysis to inform the material selection and performance of the water panel, the description of the conceptual design of the HC-HTGR RCCS derived based on the analyses results, and performance evaluation of the conceptual RCCS for the HC-HTGR. A detailed concept of the RCCS has been identified and high-level system requirements has been developed for the HC-HTGR. Design space focusing on the natural circulation loop portion of the RCCS has been investigated to optimize the system performance. The initial baseline dimensions were firstly derived based on the scoping calculations. A component level design analysis was conducted for the water panel to inform the material selection and to assess its conduction performance. A preliminary system-level performance analysis was performed for the 1/8th of the compartment of the initial baseline design of the RCCS using RELAP5-3D. To improve the system thermal performance, the RCCS design has been updated by exploring various design options by design parametric analyses. Based on the results, the conceptual design of the RCCS for the HC-HTGR has been derived, which satisfies the target performance of ~1 MWt at the elevated vessel wall temperature conditions. Transient simulations were conducted for the conceptual RCCS design for the HC-HTGR under various operation modes and heat load conditions using RELAP5-3D. The system dynamics in different operating states was investigated and the system performance under transients of interest was evaluated. The results demonstrated the overall system feasibility that the RCCS design maintains structures temperatures lower than maximum allowable temperature with sufficient system inventory without any active heat removal in the design process with certain transients addressed. The HC-HTGR RCCS will have additional design updates of subsystems or optimization of the system components during the preliminary and final design phases. Since the entire plant has not been integrated yet, this delivered conceptual design is subject to changes for integration, that require additional conceptual design activities and Quality and Assurance implementation (Q&A). The performance assessment of the RCCS for the HC-HTGR will be then revisited and optimized to finalize the system design, and the RCCS integrated primary system analysis will be utilized to simulate selective accident scenarios of interest where efforts are currently undergoing in the project.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Operational tests of a solar-energy system in Georgia

Seventy three page report describes one year performance of commercial solar-energy hot-water system. Silicone oil is heat-exchange fluid in tested system, designed to meet needs of family of four. Roll-bend heat exchanger is wrapped around hot-water storage tank. Oil circulates through exchanger and flat-plat solar collectors. Auxiliary energy, to maintain temperature in storage tank, is supplied by 4,500-watt resistance-heating element.

Source record↗

A Physical Model of Moulin Formation and Evolution

Nearly all proglacial water discharge from the present-day Greenland Ice Sheet is routed englacially via moulins. Identification of these moulins in high-resolution imagery is a frequent topic of study, but the processes controlling how and where moulins form, including on past ice sheets for which remote-sensing data are not available, remain poorly understood. Because moulins may reasonably compose approximately 10-15% of the englacial-subglacial hydrologic system, the evolution and shape of moulins can alter the timing of meltwater inputs to the bed. This evolution can impact both the form of the subglacial hydrologic system and the structure of associated geomorphological structures. Here, we develop a physical model of moulin formation and evolution to constrain the role of englacial processes in controlling the form and structure of the subglacial hydrologic system. Ice deformation within and around a moulin is both viscous and elastic, with the rate of turbulent and heat dissipation from water circulation in the moulin controlling both moulin wall melting and warming of the surrounding ice. We find moulin geometry is responsive to changes in these parameters over hours to days, indicating that diurnal and multi-day variations in surface melt can substantially alter the geometry of a moulin and the pressure-discharge relationship at the bed of the ice sheet. These results should be considered carefully when determining surface water inputs for subglacial hydrologic models. In the future, a parameter space study of these results will be combined with an analytic model to create a predictive, stochastic model of moulin and crevasse locations. This future model will be applicable to constraining the potential for surface-to-bed connections in regions where the exact ice-sheet surface morphology is not known, including ice sheets under future warming atmospheric conditions, and paleo ice sheets, where moulins created modern landforms.

Andrews, Lauren C.↗

, Experimental Investigation of Electrically Charged Water Droplets Two-Phase Cross-Flow Interactions with Humid

Electrically charged water droplets can capture water vapor molecules in surrounding moist air and promote vapor condensation. This concept unfolds an alternative to mechanical cooling-based air dehumidification systems that separate sensible and latent cooling loads in HVAC applications. The effect of dielectrophoresis, electro-hydrodynamic, and micro-diffusive flows due to highly electrically charged water droplets traveling through moist air were investigated as new methods to reduce the air’s water vapor content. This paper presents new experimental data on humidification and power consumption for a system consisting of highly energized electrosprays in combination with mist eliminators. Electrosprays produced highly charged water spray cones crossing the air perpendicularly and upwardly. The moist air stream was circulated in a horizontal duct at 22C, 80% relative humidity, and 0.24 ms-1 airspeed. Mist eliminators made of stainless wire clothes of 36 and 25 μm pore diameter were used to screen the droplets growing during their flight trajectory. The mist eliminators blocked some of the largest diameter droplets. Still, they could not prevent re-evaporation of the droplets into the bulk air from the droplets deposited on their wire clothes. The equilibrium between the dielectrophoresis condensation from the electrosprays and the droplets’ re-evaporation phenomena resulted in reduced humidification when compared to conventional-type spray evaporative cooling systems. However, to dehumidify the air, the droplets injected by the electrosprays must be separated entirely and promptly removed from the bulk airflow at the end of their flight trajectory.

Electrostatic droplets, Electrospray, humidificati↗

Thermal-Fluid Analysis of a Liquid-Cooled Battery Module for Electrified Aircraft

The development of safe, energy-dense batteries is critical to advancing hybrid electric and fully electrified aircraft propulsion. Achieving this capability requires a thermal management system that can maintain battery performance and safety under demanding operational conditions. The objective of this project is to support the maturation of next-generation lithium-ion batteries for electrified aircraft by conducting performance testing on integrated battery modules, specifically a 2-cell series configuration module housed within an aluminum enclosure. Designed to operate at a nominal 7.2 V with discharge rates up to 2.5C, the module will eventually be used to power an electric motor and DC-DC converter, generating substantial thermal loads that must be effectively managed to increase the usable energy and power density of electrified aircraft. To address these thermal challenges, this study presents the development and thermal-fluid analysis of a liquid-cooled thermal management system. While the full aircraft architecture utilizes an eight-string configuration, the present work evaluates a representative single-string water coolant loop to characterize baseline performance. The active cooling loop circulates water through a reservoir, pump, the battery module, and a variable area flow meter. Key performance metrics including component-level temperatures, mass flow rates, and pressure drops are quantified across the loop. Across discharge rates ranging from 0.5C to 2.5C, the active thermal loop consistently and effectively removed heat from the module, validating the design approach and confirming readiness for further development. The validated thermal performance indicates a path toward scalable battery modules that could enable energy and power dense systems for hybrid electric aircraft.

Electrified Aircraft↗

Improving Assimilated Global Data Sets using TMI Rainfall and Columnar Moisture Observations

A global analysis that optimally combine observations from diverse sources with physical models of atmospheric and land processes can provide a comprehensive description of the climate systems. Currently, such data products contain significant errors in primary hydrological fields such as precipitation and evaporation, especially in the tropics. In this study, we show that assimilating precipitation and total precipitable water (TPW) retrievals derived from the TRMM Microwave Imager (TMI) improves not only the hydrological cycle but also key climate parameters such as clouds, radiation, and the large-scale circulation produced by the Goddard Earth Observing System (GEOS) data assimilation system (DAS). In particular, assimilating TMI rain improves clouds and radiation in areas of active convection, as well as the latent heating distribution and the large-scale motion field in the tropics, while assimilating TMI TPW heating distribution and the large-scale motion field in the tropics, while assimilating TMI TPW retrievals leads to reduced moisture biases and improved radiative fluxes in clear-sky regions. The improved analysis also improves short-range forecasts in the tropics. Ensemble forecasts initialized with the GEOS analysis incorporating TMI rain rates and TPW yield smaller biases in tropical precipitation forecasts beyond 1 day and better 500 hPa geopotential height forecasts up to 5 days. Results of this study demonstrate the potential of using high-quality space-borne rainfall and moisture observations to improve the quality of assimilated global data for climate analysis and weather forecasting applications

Hou, Arthur Y.↗

The hydrogen sulfide emissions abatement program at the Geysers Geothermal Power Plant

The scope of the hydrogen sulfide (H2S) abatement program at The Geysers Geothermal Power Plant and the measures currently under way to reduce these emissions are discussed. The Geysers steam averages 223 ppm H2S by weight and after passing through the turbines leaves the plant both through the gas ejector system and by air-stripping in the cooling towers. The sulfide dissolved in the cooling water is controlled by the use of an oxidation catalyst such as an iron salt. The H2S in the low Btu ejector off gases may be burned to sulfur dioxide and scrubbed directly into the circulating water and reinjected into the steam field with the excess condensate. Details are included concerning the disposal of the impure sulfur, design requirements for retrofitting existing plants and modified plant operating procedures. Discussion of future research aimed at improving the H2S abatement system is also included.

Allen, G. W.↗