On the applicability of various levels of detail for occupant behavior representation and modeling in building performance simulation

Occupant behavior (OB) is one of the significant sources of uncertainty in building performance simulation. While OB modeling has received increased attention in the past decade, research on the degree of granularity or level of detail (LoD) required for representing occupants is still in the nascent stages. This paper analyzes the modeling and applicability of three LoDs to represent occupants in building performance assessment. A medium-sized prototype office building located in Chicago, Illinois is used as the simulation case study. Ten occupant-centric attributes are adopted to develop the LoDs for OB representation. We first demonstrate the different modeling approaches required for simulating the three fidelity levels. Later, we illustrate the suitability of the developed LoDs in supporting six building performance use cases across different lifecycle stages. Furthermore, this study intends to provide guidance for the building simulation community on appropriate OB representation to support various use cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implementation of a realistic artificial data generator for crash data generation

In this paper, a framework is outlined to generate realistic artificial data (RAD) as a tool for comparing different models developed for safety analysis. The primary focus of transportation safety analysis is on identifying and quantifying the influence of factors contributing to traffic crash occurrence and its consequences. The current framework of comparing model structures using only observed data has limitations. With observed data, it is not possible to know how well the models mimic the true relationship between the dependent and independent variables. Further, real datasets do not allow researchers to evaluate the model performance for different levels of complexity of the dataset. RAD offers an innovative framework to address these limitations. Hence, we propose a RAD generation framework embedded with heterogeneous causal structures that generates crash data by considering crash occurrence as a trip level event impacted by trip level factors, demographics, roadway and vehicle attributes. Within our RAD generator we employ three specific modules: (a) disaggregate trip information generation, (b) crash data generation and (c) crash data aggregation. For disaggregate trip information generation, we employ a daily activity-travel realization for an urban region generated from an established activity-based model for the Chicago region. We use this data of more than 2 million daily trips to generate a subset of trips with crash data. For trips with crashes crash location, crash type, driver/vehicle characteristics, and crash severity. The daily RAD generation process is repeated for generating crash records at yearly or multi-year resolution. In conclusion, the crash databases generated can be employed to compare frequency models, severity models, crash type and various other dimensions by facility type - possibly establishing a universal benchmarking system for alternative model frameworks in safety literature.

42 ENGINEERING↗

Resilient cooling through geothermal district energy system

Decarbonization and resilience to heat waves have recently become high priorities for building and district energy systems. Geothermal coupled district heating and cooling systems that operate a water loop near ground temperature gain increasing adoption to support decarbonization. In these systems, vapor-compression machines, distributed in the energy transfer stations, lift the temperature up or down to the needs of the particular building. In principle, these systems can provide low-power, free cooling from the geothermal bore field during heat waves when electricity is often scarce. However, the performance of such a resilience operation mode and its implication on the energy system configuration and the sizing of the bore field and HVAC equipment is not yet understood. Consequently, we are assessing their resilience, power use and design implications under a scenario of a heat wave on five working days during which chillers are switched off to reduce electrical consumption. Our analysis is based on high-fidelity, coupled dynamic models of district energy, building-side HVAC and actual control logic, with whole building energy simulation used to assess thermal conditions in a 2004 vintage multi-zone office building in Chicago, IL. The results show that relying only on waterside economizer cooling, the indoor thermal conditions can be maintained in a tolerable range for the majority of the building zones with half the electrical energy compared to standard chiller operation. Thermal comfort in the hottest zones can be further improved by oversizing the cooling coil. However, the waterside economizer has significant implications on the system configuration and sizing: The geothermal bore field needs to be sized about 30% larger than the upper limit of the range observed for conventional geothermal systems. Nevertheless, if a central chiller plant is added, the bore field can be downsized to the typical design range. The latter configuration still allows compressor-less cooling during the heat wave with peak power reduced by 60% compared to the standard design and chiller operation.

15 GEOTHERMAL ENERGY↗

Enhancing flexibility for climate change using seasonal energy storage (aquifer thermal energy storage) in distributed energy systems

Long-term energy storage is expected to play a vital role in the deep decarbonization of building energy sectors, while enhancing the flexibility of buildings to withstand future climate variations. However, it is challenging to design distributed multi-energy systems (DMES) while taking into account the uncertainties introduced by climate change, since stochastic optimization of such systems is difficult. The present study introduces a stochastic optimization model to address this bottleneck, taking into account DMES including aquifer thermal energy storage (ATES) as the long-term thermal storage. For the first time, a novel optimization algorithm links ATES with the DMES optimization model with the support of a simplified geotechnical model. Subsequently, a case study was conducted, focusing on a residential district in Chicago where the impact of future climate condition, energy demand, and solar and wind energy potentials were evaluated using Weather Research and Forecasting (WRF) data (up to 2080) and the EnergyPlus model. The study revealed that ATES is an attractive way to improve the renewable energy penetration level and minimize the dependence on fossil fuels with reasonable support from the grid to assist the fluctuations in both demand and generation. Furthermore, ATES notably reduces fuel consumption and dependence while greatly enhancing the flexibility of the energy system to withstand fluctuations in demand and renewable energy generation brought by future climate variations. These qualities will make ATES an important part of distributed energy systems, even though it is not currently the lowest cost alternative due to lack of technology maturity. Furthermore, the design platform introduced in the present study can be used to design DMES enhancing flexibility to accommodate future climate variations.

25 ENERGY STORAGE↗

Establishing nationwide power system vulnerability index across US counties using interpretable machine learning

Power outages have become increasingly frequent, intense, and prolonged in the US due to climate change, aging electrical grids, and rising energy demand. However, largely due to the absence of granular spatiotemporal outage data, we lack data-driven evidence and analytics-based metrics to quantify power system vulnerability. This limitation has hindered the ability to effectively evaluate and address vulnerability to power outages in US communities. Here, in this work, we collected ∼179 million power outage records at 15-min intervals across 3022 US contiguous counties (96.15 % of the area) from 2014 to 2023. We developed a power system vulnerability assessment framework based on three dimensions (intensity, frequency, and duration) and applied interpretable machine learning models (XGBoost and SHAP) to compute Power System Vulnerability Index (PSVI) at the county level. Our analysis reveals a consistent increase in power system vulnerability across the US counties over the past decade. We identified 318 counties across 45 states as hotspots for high power system vulnerability, particularly in the West Coast (California and Washington), the East Coast (Florida and the Northeast area), the Great Lakes megalopolis (Chicago-Detroit metropolitan areas), and the Gulf of Mexico (Texas). Our heterogeneity analysis indicates that urban counties and those located along regional transmission boundaries tend to exhibit significantly higher vulnerability. Our results highlight the significance of the proposed PSVI for evaluating the vulnerability of communities to power outages. The findings underscore the widespread and pervasive impact of power outages across the country and offer crucial insights to support infrastructure operators, policymakers, and emergency managers in formulating policies and programs aimed at enhancing the resilience of the US power infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nexus of thermal resilience and energy efficiency in buildings: A case study of a nursing home

Extreme weather events become more frequent and severe due to climate change. Although energy efficiency technologies can influence thermal resilience of buildings, they are traditionally studied separately, and their interconnections are rarely quantified. This study developed a methodology of modeling and analysis to provide insights into the nexus of thermal resilience and energy efficiency of buildings. In this work, we conducted a case study of a real nursing home in Florida, where 12 patients died during Hurricane Irma in 2017 due to HVAC system power loss, to understand and quantify how passive and active energy efficiency measures (EEMs) can improve thermal resilience to reduce heat-exposure risk of patients. Results show that passive measures of opening windows and doors for natural ventilation, as well as miscellaneous load reduction, are very effective in eliminating the extreme dangerous occasions. However, to maintain safe conditions, active measures such as on-site power generators and thermal storage are also needed. The nursing home was further studied by changing its location to two other cities: San Francisco (mild climate) and Chicago (cold winter and hot summer). Results revealed that the EEMs' impacts on thermal resilience vary significantly by climate and building characteristics. The study also estimated the costs of EEMs to help stakeholders prioritize the measures. Passive measures that may not save energy may greatly improve thermal resilience, and thus should be considered in building design or retrofit. Findings from this study indicate energy efficiency technologies should be evaluated not only by their energy savings performance but also by their influence on a building's resilience to extreme weather events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A simulation-based assessment of technologies to reduce heat emissions from buildings

Heat emissions from buildings are part of anthropogenic heat leading to urban overheating. This paper aims to assess how technologies (i.e., energy conservation measures - ECMs), used to decrease energy use, may also reduce heat emissions from buildings. This study employs the physics-based engine EnergyPlus to simulate the main components of heat emissions from buildings to ambient air: envelope, zone, and systems. Hourly simulations are run for IECC single- and multi-family reference models with three representative climates: Miami, Baltimore, and Chicago. The results show that the performance of ECMs varies among weather, seasons, and residential typologies. Particularly, some ECMs (i.e., cool coatings, heat pumps, additional insulation, energy-awareness occupants) show a strong decrease in heat emissions, yet they are not always correlated with proportional decreases in energy use. When all ECMs are combined, the reductions are larger on heat emissions (89%) than on site energy (65%) from the base cases. During summer in Miami, the combination of ECMs shows a decrease in heat emissions from the building surface component of 80% during daytime, 92% for the HVAC component and a counterbalanced increase in the zone component of 88%, bringing to a daily decrease in total heat emissions. The main contributions of this study are quantifying how typical ECMs influence residential building heat emissions using EnergyPlus simulations and informing urban planners and stakeholders on prioritizing measures for mitigating urban overheating problems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Whole-building life-cycle analysis with a new GREET® tool: Embodied greenhouse gas emissions and payback period of a LEED-Certified library

Embodied greenhouse gas (GHG) emissions of building components and buildings operations need to be quantified to holistically address building sustainability. To evaluate embodied GHG emissions of buildings and to provide insights on building materials and building design decisions toward decarbonization, we have recently created a building life-cycle assessment (LCA) module in the widely used Greenhouse gases, Regulated Emissions, and Energy use in Technologies (GREET (R)) LCA model. We applied the GREET building LCA module to examine embodied GHG impacts and the payback period of a LEED (Leadership in Energy and Environmental Design) certified public library in Chicago, USA. We developed localized, detailed life-cycle inventories to address individual building materials used in the library. We expanded the LCA system boundary to include the mechanical, electrical, and plumbing system, as well as refrigerant impacts, which are often ignored in previous studies. Results show that the total embodied GHG emissions are approximately 817 metric tons, or approximately 538 kg/m 2 . Sensitivity analysis highlights the positive role of increasing the use of recycled materials for reducing embodied GHG emissions. Sensitivity analysis on embodied GHG emissions payback periods shows the need to benchmark the embodied and operational carbon performance of buildings for comparison to alternative building designs and sustainability practices. Furthermore, this analysis demonstrates that building LCA models, such as the GREET building LCA module, which addresses embodied and operational GHG emission impacts of whole buildings holistically, could empower building architects, technology developers, manufacturers, and general contractors to address embodied and operational impacts holistically for building sustainability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Incorporating space and time into random forest models for analyzing geospatial patterns of drug-related crime incidents in a major U.S. metropolitan area

The opioid crisis has hit American cities hard, and research on spatial and temporal patterns of drug-related activities including detecting and predicting clusters of crime incidents involving particular types of drugs is useful for distinguishing hot zones where drugs are present that in turn can further provide a basis for assessing and providing related treatment services. In this study, we investigated spatiotemporal patterns of more than 52,000 reported incidents of drug-related crime at block group granularity in Chicago, IL between 2016 and 2019. We applied a space-time analysis framework and machine learning approaches to build a model using training data that identified whether certain locations and built environment and sociodemographic factors were correlated with drug-related crime incident patterns, and establish the top contributing factors that underlaid the trends. Space and time, together with multiple driving factors, were incorporated into a random forest model to analyze these changing patterns. We accommodated both spatial and temporal autocorrelation in the model learning process to assist with capturing the changes over time and tested the capabilities of the space-time random forest model by predicting drug-related activity hot zones. Overall, we focused particularly on crime incidents that involved heroin and synthetic drugs as these have been key drug types that have highly impacted cities during the opioid crisis in the U.S.

97 MATHEMATICS AND COMPUTING↗

Designing a drone delivery network with automated battery swapping machines

Drones are projected to alter last-mile delivery, but their short travel range is a concern. In this study, we propose a drone delivery network design using automated battery swapping machines (ABSMs) to extend ranges. The design minimizes the long-term delivery costs, including ABSM investment, drone ownership, and cost of the delivery time, and locates ABSMs to serve a set of customers. We build a mixed-integer nonlinear program that captures the nonlinear waiting time of drones at ABSMs. To solve the problem, we create an exact solution algorithm that finds the globally optimal solution using a derivative-supported cutting-plane method. To validate the applicability of our program, we conduct a case study on the Chicago Metropolitan area using cost data from leading ABSM manufacturer and geographical data from the planning and operations language for agent-based regional integrated simulation (more commonly known as POLARIS). A sensitivity analysis identifies that ABSM service times and costs are the key parameters impacting the long-term adoption of drone delivery.

25 ENERGY STORAGE↗

Designing interagency responses to wicked problems: A viable system model board game

Government agencies struggle to address wicked problems because they are open-ended, highly interdependent issues that cross agency, stakeholder, jurisdictional, and geopolitical boundaries. While both quantitative modelling and qualitative problem structuring methodologies have been used to support interagency decision making in the past, co-designing an effective interagency organization to collaboratively tackle wicked problems is more challenging. Few approaches have been developed to enable such efforts. This paper explains how the viable system model (VSM) was implemented through a board game, which was employed to co-design an interagency meta-organization that would be capable of more effectively collaborating to jointly address a wicked problem: international organized drug crime and its interface with local gangs in Chicago, USA. The board game was developed to make the VSM easier for the participants to learn, given that the cybernetic language and engineering-influenced diagrams in the original literature can be off-putting to leaders and managers. The board game was used as the final stage of a multi-method, systemic approach, which involved boundary critique and problem structuring as well as deployment of the VSM. The research findings indicate that the VSM board game, used as part of a larger mixed-methods systemic intervention, contributes to building trust in the value of systems thinking amongst the participants, and sets up a rich context for collaboration on multi-agency co-design. The game therefore offers significant promise as part of the co-design of interagency responses to wicked problems because it creates an embodied process for stakeholders to learn about the VSM. It also reduces the work involved in this learning. Thus, the game enables an effective appropriation of the VSM language and criteria.

Business & Economics↗

Machine learning-enhanced hybrid modeling approach for better identification of a building thermal network model and improved prediction

The gray-box modeling approach, which uses a semi-physical thermal network model, has been widely used in building prediction applications, such as model predictive control (MPC). However, unmeasured disturbances, such as occupants, lighting, and in/exfiltration loads, make it challenging to apply this approach to practical buildings. In this word, we propose a hybrid modeling approach that integrates the gray-box model with a model for unmeasured disturbance. After reviewing several system identification approaches, we systematically designed the unmeasured disturbance model with a model selection process based on statistical tests to make it robust. We generated data based on the building model calibrated by real operational data and then trained the hybrid model for two different weather conditions. The hybrid model approach demonstrates an RMSE reduction of approximately 0.2–0.9 °C and 0.3–2 °C on 1-day ahead temperature prediction compared to the Conventional approach for mild (Berkeley, CA) and cold (Chicago, IL) climates, respectively. In addition, this approach was applied to experimental data obtained from the laboratory building to be used for the MPC application, showing superior prediction performances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Performance Variables to Accelerate the Deployment of Sustainable Aviation Fuels at a Regional Scale

An increase in jet fuel consumption and its associated emissions across the world have led to the need for alternative technologies to produce sustainable aviation fuels (SAF). One option to produce SAFs is to utilize waste or biomass-based feedstocks that has the potential to reduce greenhouse gas emissions by 50% or more compared to conventional jet fuel. However, there is a lack of understanding of how the synergistic effects of key performance variables could hinder or help the deployment of aviation fuels on a regional scale. Here, we assess the implications of key variables-including type and quantity of waste/biomass feedstock availability near the airport, cost of SAF production, life cycle greenhouse gas (GHG) emissions, policies, and fuel/infrastructure logistics-on the deployment of SAF at Chicago's O'Hare International Airport. We consider three ASTM International-approved SAF technologies (Hydroprocessed Esters and Fatty Acids, Fischer-Tropsch, and Alcohol to Jet) that can be blended up to 50% with petroleum-based jet fuel. Results from our analysis show that woody biomass-based Fischer-Tropsch technology has the lowest fuel production costs ($2.31-$2.81/gallon gasoline equivalent) of all pathways, and it reduces life cycle GHG emissions by 86% compared to conventional jet fuel despite the higher availability of crop residues compared to either woody biomass or fats, oils, and greases. Also, infrastructure is available at O'Hare International Airport to blend SAF with Jet A fuel through three terminals directly connected to the airport via pipelines. Our sensitivity analysis shows renewable fuel incentives and feedstock price to be key performance variables affecting the production cost and deployment of SAF.

alcohol-to-jet↗

Interpenetration and kinetic effects in converging, high-energy plasma jets

In this work, we report on numerical simulations of laser-driven convergent plasma fusion targets. These “inverted corona” fusion targets are useful for the study of counter-streaming and converging rarefied plasma flows, and previous experiments have demonstrated their potential as neutron sources. The scheme consists of a fuel layer lined along the interior surface of a hollow plastic shell that is laser-ablated and expands inward towards the target center. The plasma streams generated in these targets are initially nearly collisionless as they converge, leading to wide interaction length scales and long interaction time scales as the jets interpenetrate. Such kinetic effects impact mixing of constituent ions - a phenomenon not properly captured by single-fluid hydrodynamic simulations. Here we conduct numerical simulations using two different methods: (1) single-fluid simulations in HYDRA, and (2) kinetic-ion, fluid-electron hybrid particle-in-cell (PIC) simulations in the code Chicago. It is shown that the initially nearly collisionless plasma fronts interpenetrate deeply and lead to broader interaction regions in space and time resulting in significant beam-beam fusion. The two approaches make different, testable predictions for the effect of fuel-layer thickness on neutron yield.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proper orthogonal decomposition based reduced-order modeling of flux-Limited gray thermal radiation

Here, in this work, a proper orthogonal decomposition (POD) based reduced-order model (ROM) is developed to solve gray, flux-limited thermal radiation diffusion. We focus on the variable opacity radiation penetration benchmark posed by Olson, Auer, and Hall. The T -3 relationship for opacity in conjunction with high-temperature radiation penetrating an initially cold material produces a strong thermal radiation shock. This class of problems is particularly challenging for standard POD-based reduced-order modeling due to the nonlinearities presented by 1) the T 4 source term, and 2) flux-limited diffusion operator. To address these challenges and develop a cost competitive ROM, we employ a “hyper-reduction” technique through discrete empirical interpolation (DEIM) and allow for adaptive reduced-order projections through principal interval decomposition (PID). Performance of the proposed methodology is quantified by comparing the cost savings and accuracy relative to a full-order computation. Reference solutions and snapshot data are obtained through a full-order calculation performed by the University of Chicago maintained astrophysics code, FLASH. For consistency and potential extensibility, the developed ROM is also implemented in FLASH. We find that in the initialization regime, where the thermal radiation wave is initially created by the warming of the material, this class of problems is highly reducible and suitable for POD-based ROMs. However, the strong convective nature of the wave propagation regime is less reducible and more challenging to create an efficient ROM.

42 ENGINEERING↗

O'Hare Airport roadway traffic prediction via data fusion and Gaussian process regression

This study proposes an approach of leveraging information gathered from multiple traffic data sources at different resolutions to obtain approximate inference on the traffic distribution of Chicago's O'Hare Airport area. Specifically, it proposes the ingestion of traffic datasets at different resolutions to build spatiotemporal models for predicting the distribution of traffic volume on the road network. Due to its good adaptability and flexibility for spatiotemporal data, the Gaussian process (GP) regression was employed to provide short-term forecasts using data collected by loop detectors (sensors) and supplemented by telematics data. The GP regression is used to make predictions of the distribution of the proportion of sensor data traffic volume represented by the telematics data for each location of the sensors. Consequently, the fitted GP model can be used to determine the approximate traffic distribution for a testing location outside of the training points. Policymakers in the transportation sector can find the results of this work helpful for making informed decisions relating to current and future transportation conditions in the area.

42 ENGINEERING↗

Multiscale characterization and comparison of historical and modern nuclear graphite grades

Beginning with Chicago Pile I, graphite has been used as a moderator material in nuclear power stations and is considered a potential material for use in future Generation IV advanced reactors. The microstructure of graphite is responsible for much of its mechanical and thermo-physical properties, and how it responds to irradiation. To understand graphite microstructure, it is necessary to understand its porosity at the macro- and micro-scales; and to understand its porosity, it is necessary to characterize the morphological connectivity of the void content and the two main phases of graphite: filler and binder. Here, using several microscopy and analytical techniques, a detailed examination of the heterogeneity, microstructure and pore structure of different graphite grades and their binder and filler phases is presented. Significant differences were found between coarser and finer nuclear grades. Coarse grades have a more diverse range of filler particles, pores and thermal cracks. Finer grades have a more well-defined pore size distribution, fewer variations of filler particles sizes and do not contain as many large thermal cracks. Fine grades tend to have a well-connected network of pores whereas coarser grades contain a larger content of closed porosity. The framework developed within this work can be applied and used to assess the various graphite grades that would down-select materials for specific use in graphite moderated reactor designs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗