Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Centroid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Implementation of Feedback-Guided Voluntary Breath-Hold Gating for Cone Beam CT-Based Stereotactic Body Radiotherapy

Purpose: To analyze tumor position reproducibility of feedback-guided voluntary deep inspiration breath-hold (FGBH) gating for cone beam computed tomography (CBCT)-based stereotactic body radiotherapy (SBRT). Methods and materials: Thirteen early-stage lung cancer patients eligible for SBRT with tumor motion of >1cm were evaluated for FGBH-gated treatment. Multiple FGBH CTs were acquired at simulation, and single FGBH CBCTs were also acquired prior to each treatment. Simulation CTs and treatment CBCTs were analyzed to quantify reproducibility of tumor positions during FGBH. Benefits of FGBH gating compared to treatment during free breathing, as well treatment with gating at exhalation, were examined for lung sparing, motion margins, and reproducibility of gross tumor volume (GTV) position relative to nonmoving anatomy. Results: FGBH increased total lung volumes by 1.5 times compared to free breathing, resulting in a proportional drop in total lung volume receiving 10 Gy or more. Intra- and inter-FGBH reproducibility of GTV centroid positions at simulation were 1.0 {+-} 0.5 mm, 1.3 {+-} 1.0 mm, and 0.6 {+-} 0.4 mm in the anterior-posterior (AP), superior-inferior (SI), and left-right lateral (LR) directions, respectively, compared to more than 1 cm of tumor motion at free breathing. During treatment, inter-FGBH reproducibility of the GTV centroid with respect to bony anatomy was 1.2 {+-} 0.7 mm, 1.5 {+-} 0.8 mm, and 1.0 {+-} 0.4 mm in the AP, SI, and LR directions. In addition, the quality of CBCTs was improved due to elimination of motion artifacts, making this technique attractive for poorly visualized tumors, even with small motion. Conclusions: The extent of tumor motion at normal respiration does not influence the reproducibility of the tumor position under breath hold conditions. FGBH-gated SBRT with CBCT can improve the reproducibility of GTV centroids, reduce required margins, and minimize dose to normal tissues in the treatment of mobile tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Localization Accuracy of the Clinical Target Volume During Image-Guided Radiotherapy of Lung Cancer

Purpose: To evaluate the position and shape of the originally defined clinical target volume (CTV) over the treatment course, and to assess the impact of gross tumor volume (GTV)-based online computed tomography (CT) guidance on CTV localization accuracy. Methods and Materials: Weekly breath-hold CT scans were acquired in 17 patients undergoing radiotherapy. Deformable registration was used to propagate the GTV and CTV from the first weekly CT image to all other weekly CT images. The on-treatment CT scans were registered rigidly to the planning CT scan based on the GTV location to simulate online guidance, and residual error in the CTV centroids and borders was calculated. Results: The mean GTV after 5 weeks relative to volume at the beginning of treatment was 77% {+-} 20%, whereas for the prescribed CTV, it was 92% {+-} 10%. The mean absolute residual error magnitude in the CTV centroid position after a GTV-based localization was 2.9 {+-} 3.0 mm, and it varied from 0.3 to 20.0 mm over all patients. Residual error of the CTV centroid was associated with GTV regression and anisotropy of regression during treatment (p = 0.02 and p = 0.03, respectively; Spearman rank correlation). A residual error in CTV border position greater than 2 mm was present in 77% of patients and 50% of fractions. Among these fractions, residual error of the CTV borders was 3.5 {+-} 1.6 mm (left-right), 3.1 {+-} 0.9 mm (anterior-posterior), and 6.4 {+-} 7.5 mm (superior-inferior). Conclusions: Online guidance based on the visible GTV produces substantial error in CTV localization, particularly for highly regressing tumors. The results of this study will be useful in designing margins for CTV localization or for developing new online CTV localization strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfractional Positional Variability of Fiducial Markers and Primary Tumors in Locally Advanced Non-Small-Cell Lung Cancer During Audiovisual Biofeedback Radiotherapy

Purpose: To evaluate implanted markers as a surrogate for tumor-based setup during image-guided lung cancer radiotherapy with audiovisual biofeedback. Methods and Materials: Seven patients with locally advanced non-small-cell lung cancer were implanted bronchoscopically with gold coils. Markers, tumor, and a reference bony structure (vertebra) were contoured for all 10 phases of the four-dimensional respiration-correlated fan-beam computed tomography and weekly four-dimensional cone-beam computed tomography. Results: The systematic/random interfractional marker-to-tumor centroid displacements were 2/3, 2/2, and 3/3 mm in the x (lateral), y (anterior-posterior), and z (superior-inferior) directions, respectively. The systematic/random interfractional marker-to-bone displacements were 2/3, 2/3, and 2/3 mm in the x, y, and z directions, respectively. The systematic/random tumor-to-bone displacements were 2/3, 2/4, and 4/4 mm in the x, y, and z directions, respectively. All displacements changed significantly over time (p < 0.0001). Conclusions: Although marker-based image guidance may decrease the risk for geometric miss compared with bony anatomy-based positioning, the observed displacements between markers and tumor centroids indicate the need for repeated soft tissue imaging, particularly in situations with large tumor volume change and large initial marker-to-tumor centroid distance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intrafraction Bladder Motion in Radiation Therapy Estimated From Pretreatment and Posttreatment Volumetric Imaging

Purpose: The use of image guidance protocols using soft tissue anatomy identification before treatment can reduce interfractional variation. This makes intrafraction clinical target volume (CTV) to planning target volume (PTV) changes more important, including those resulting from intrafraction bladder filling and motion. The purpose of this study was to investigate the required intrafraction margins for soft tissue image guidance from pretreatment and posttreatment volumetric imaging. Methods and Materials: Fifty patients with muscle-invasive bladder cancer (T2-T4) underwent an adaptive radiation therapy protocol using daily pretreatment cone beam computed tomography (CBCT) with weekly posttreatment CBCT. A total of 235 pairs of pretreatment and posttreatment CBCT images were retrospectively contoured by a single radiation oncologist (CBCT-CTV). The maximum bladder displacement was measured according to the patient's bony pelvis movement during treatment, intrafraction bladder filling, and bladder centroid motion. Results: The mean time between pretreatment and posttreatment CBCT was 13 minutes, 52 seconds (range, 7 min 52 sec to 30 min 56 sec). Taking into account patient motion, bladder centroid motion, and bladder filling, the required margins to cover intrafraction changes from pretreatment to posttreatment in the superior, inferior, right, left, anterior, and posterior were 1.25 cm (range, 1.19-1.50 cm), 0.67 cm (range, 0.58-1.12 cm), 0.74 cm (range, 0.59-0.94 cm), 0.73 cm (range, 0.51-1.00 cm), 1.20 cm (range, 0.85-1.32 cm), and 0.86 cm (range, 0.73-0.99), respectively. Small bladders on pretreatment imaging had relatively the largest increase in pretreatment to posttreatment volume. Conclusion: Intrafraction motion of the bladder based on pretreatment and posttreatment bladder imaging can be significant particularly in the anterior and superior directions. Patient motion, bladder centroid motion, and bladder filling all contribute to changes between pretreatment and posttreatment imaging. Asymmetric expansion of CTV to PTV should be considered. Care is required in using image-guided radiation therapy protocols that reduce CTV to PTV margins based only on daily pretreatment soft tissue position.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Time-Adjusted Internal Target Volume: A Novel Approach Focusing on Heterogeneity of Tumor Motion Based on 4-Dimensional Computed Tomography Imaging for Radiation Therapy Planning of Lung Cancer

Purpose: To consider nonuniform tumor motion within the internal target volume (ITV) by defining time-adjusted ITV (TTV), a volume designed to include heterogeneity of tumor existence on the basis of 4-dimensional computed tomography (4D-CT). Methods and Materials: We evaluated 30 lung cancer patients. Breath-hold CT (BH-CT) and free-breathing 4D-CT scans were acquired for each patient. The tumors were manually delineated using a lung CT window setting (window, 1600 HU; level, −300 HU). Tumor in BH-CT images was defined as gross tumor volume (GTV), and the sum of tumors in 4D-CT images was defined as ITV-4D. The TTV images were generated from the 4D-CT datasets, and the tumor existence probability within ITV-4D was calculated. We calculated the TTV{sub 80} value, which is the percentage of the volume with a tumor existence probability that exceeded 80% on ITV-4D. Several factors that affected the TTV{sub 80} value, such as the ITV-4D/GTV ratio or tumor centroid deviation, were evaluated. Results: Time-adjusted ITV images were acquired for all patients, and tumor respiratory motion heterogeneity was visualized. The median (range) ITV-4D/GTV ratio and median tumor centroid deviation were 1.6 (1.0-4.1) and 6.3 mm (0.1-30.3 mm), respectively. The median TTV{sub 80} value was 43.3% (2.9-98.7%). Strong correlations were observed between the TTV{sub 80} value and the ITV-4D/GTV ratio (R=−0.71) and tumor centroid deviation (R=−0.72). The TTV images revealed the tumor motion pattern features within ITV. Conclusions: The TTV images reflected nonuniform tumor motion, and they revealed the tumor motion pattern features, suggesting that the TTV concept may facilitate various aspects of radiation therapy planning of lung cancer while incorporating respiratory motion in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiochemical study of the kinematics of multi-nucleon transfer reactions in 48 Ca + 248 Cm collisions 10% above the Coulomb barrier

In this paper, the kinematics of multi-nucleon transfer reactions in 48 Ca + 248 Cm collisions at 262 MeV (center of target) was investigated by using a stacked-foil technique and radiochemical separations of trans-curium elements. Trans-curium isotopes were identified by α-particle spectroscopy. For Fm isotopes, by comparing the centroids of the measured post-neutron emission isotope distributions with the most probable primary mass number predicted by Volkov's generalized Q g g systematics, the missing mass (number of evaporated neutrons) is estimated. The latter is compared with that deduced from the measured centroid of the laboratory angular distribution peaked closely to the grazing angle and the centroid of the range distribution, being used to determine the average total kinetic energy loss (TKEL) and the average excitation energy. The latter agrees within the uncertainties with the missing mass so that a consistent picture of the reaction mechanism emerges. For products closer to the target Z, e.g., Cf and Bk, the distributions of kinetic energies are much broader than for Fm, reflecting the fact that in the former, values of TKEL reach from quasi-elastic scattering all the way to deep inelastic scattering. Finally, the measured laboratory angular distribution and the average laboratory kinetic energy of the Fm isotopes, being the prototypes for multi-nucleon transfer products, are benchmark values for the design of electromagnetic separators to be constructed for the separation and detection of unknown neutron-rich transactinides produced in this nuclear reaction type.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The Zonal Patterns in Late Quaternary Tropical South American Precipitation

Speleothem oxygen isotope records (δ 18 O) of tropical South American rainfall in the late Quaternary show a zonal “South American Precipitation Dipole” (SAPD). The dipole is characterized by opposing east-west precipitation anomalies compared to the present—wetter in the east and drier in the west at the mid-Holocene (~7 ka), and drier in the east and wetter in the west at the Last Glacial Maximum (~21 ka). However, the SAPD remains enigmatic because it is expressed differently in western versus eastern δ18O records and isotope-enabled climate model simulations usually misrepresent the magnitude and/or spatial pattern of δ 18 O change. Here, we address the SAPD enigma in two parts. First, we re-interpret the δ 18 O data to account for upwind rainout effects that are known to be pervasive in tropical South America, but are not always considered in Quaternary paleoclimate studies. Our revised interpretation reconciles the δ 18 O data with cave infiltration and other proxy records, and indicates that the centroid of tropical South American rainfall has migrated zonally over time. Second, using an energy balance model of tropical atmospheric circulation, we hypothesize that zonal migration of the precipitation centroid can be explained by regional energy budget shifts, such as changing Saharan albedo associated with the African Humid Period, that have not been modeled in previous SAPD studies. This hypothesis of a migrating precipitation centroid presents a new framework for interpreting δ18O records from tropical South America and may help explain the zonal rainfall anomalies that predate the late Quaternary.

54 ENVIRONMENTAL SCIENCES↗

Polymer escape from a confining potential

The rate of escape of polymers from a two-dimensionally confining potential well has been evaluated using self-avoiding as well as ideal chain representations of varying length, up to 80 beads. Long timescale Langevin trajectories were calculated using the path integral hyperdynamics method to evaluate the escape rate. A minimum is found in the rate for self-avoiding polymers of intermediate length while the escape rate decreases monotonically with polymer length for ideal polymers. The increase in the rate for long, self-avoiding polymers is ascribed to crowding in the potential well which reduces the free energy escape barrier. An effective potential curve obtained using the centroid as an independent variable was evaluated by thermodynamic averaging and Kramers rate theory then applied to estimate the escape rate. While the qualitative features are well reproduced by this approach, it significantly overestimates the rate, especially for the longer polymers. The reason for this is illustrated by constructing a two-dimensional effective energy surface using the radius of gyration as well as the centroid as controlled variables. This shows that the description of a transition state dividing surface using only the centroid fails to confine the system to the region corresponding to the free energy barrier and this problem becomes more pronounced the longer the polymer is. A proper definition of a transition state for polymer escape needs to take into account the shape as well as the location of the polymer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A whole-path importance-sampling scheme for Feynman path integral calculations of absolute partition functions and free energies

Using Feynman path integrals, a molecular partition function can be written as a double integral with the inner integral involving all closed paths centered at a given molecular configuration, and the outer integral involving all possible molecular configurations. In previous work employing Monte Carlo methods to evaluate such partition functions, we presented schemes for importance sampling and stratification in the molecular configurations that constitute the path centroids, but we relied on free-particle paths for sampling the path integrals. At low temperatures, the path sampling is expensive because the paths can travel far from the centroid configuration. In this paper, we now present a scheme for importance sampling of whole Feynman paths based on harmonic information from an instantaneous normal mode calculation at the centroid configuration, which we refer to as harmonically guided whole-path importance sampling (WPIS). We obtain paths conforming to our chosen importance function by rejection sampling from a distribution of free-particle paths. Sample calculations on CH 4 demonstrate that at a temperature of 200 K, about 99.9% of the free-particle paths can be rejected without integration, and at 300 K, about 98% can be rejected. Finally, we also show that it is typically possible to reduce the overhead associated with the WPIS scheme by sampling the paths using a significantly lower-order path discretization than that which is needed to converge the partition function.

74 ATOMIC AND MOLECULAR PHYSICS↗

ANALYSIS OF CORONAL GREEN LINE PROFILES: EVIDENCE OF EXCESS BLUESHIFTS

Coronal green line (Fe XIV 5303 A) profiles were obtained from Fabry-Perot interferometric observations of the solar corona during the total solar eclipse of 2001 June 21 from Lusaka, Zambia. The instrumental width is about 0.2 A and the spectral resolution is about 26,000. About 300 line profiles were obtained within a radial range of 1.0-1.5 R{sub sun} and a position angle coverage of about 240{sup 0}. The line profiles were fitted with single Gaussians, and their intensities, Doppler velocities, and line widths were obtained. Also obtained were the centroids of the line profiles, which give a measure of line asymmetry. The histograms of Doppler velocity show excess blueshifts, while the centroids reveal a predominant blue wing in the line profiles. It was found that the centroids and the Doppler velocities are highly correlated. This points to the presence of multiple components in the line profiles, with an excess of blueshifted components. We then obtained the (Blue-Red) wing intensities, which clearly reveal the secondary components, the majority of which are blueshifted. This confirms that the coronal green line profiles often contain multicomponents with excess blueshifts, which also depend on the solar activity. The magnitude of the Doppler velocity of the secondary components is in the range of 20-40 km s{sup -1} and shows an increase toward the poles. Possible explanations of the multicomponents are the type II spicules that were recently found to be important to coronal heating or the nascent solar wind flow, but the cause of the blue asymmetry in the coronal lines above the limb remains unclear.

79 ASTRONOMY AND ASTROPHYSICS↗

GALAXIES IN X-RAY GROUPS. II. A WEAK LENSING STUDY OF HALO CENTERING

Locating the centers of dark matter halos is critical for understanding the mass profiles of halos, as well as the formation and evolution of the massive galaxies that they host. The task is observationally challenging because we cannot observe halos directly, and tracers such as bright galaxies or X-ray emission from hot plasma are imperfect. In this paper, we quantify the consequences of miscentering on the weak lensing signal from a sample of 129 X-ray-selected galaxy groups in the COSMOS field with redshifts 0 < z < 1 and halo masses in the range 10{sup 13}-10{sup 14} M{sub Sun }. By measuring the stacked lensing signal around eight different candidate centers (such as the brightest member galaxy, the mean position of all member galaxies, or the X-ray centroid), we determine which candidates best trace the center of mass in halos. In this sample of groups, we find that massive galaxies near the X-ray centroids trace the center of mass to {approx}< 75 kpc, while the X-ray position and centroids based on the mean position of member galaxies have larger offsets primarily due to the statistical uncertainties in their positions (typically {approx}50-150 kpc). Approximately 30% of groups in our sample have ambiguous centers with multiple bright or massive galaxies, and some of these groups show disturbed mass profiles that are not well fit by standard models, suggesting that they are merging systems. We find that halo mass estimates from stacked weak lensing can be biased low by 5%-30% if inaccurate centers are used and the issue of miscentering is not addressed.

79 ASTRONOMY AND ASTROPHYSICS↗

PRE-SPECTROSCOPIC FALSE-POSITIVE ELIMINATION OF KEPLER PLANET CANDIDATES

Ten days of commissioning data (Quarter 0) and 33 days of science data (Quarter 1) yield instrumental flux time series of {approx}150,000 stars that were combed for transit events, termed threshold crossing events(TCE), each having a total detection statistic above 7.1{sigma}. TCE light curves are modeled as star+planet systems. Those returning a companion radius smaller than 2R{sub J} are assigned a Kepler Object of Interest (KOI) number. The raw flux, pixel flux, and flux-weighted centroids of every KOI are scrutinized to assess the likelihood of being an astrophysical false positive versus the likelihood of being a planetary companion. This vetting using Kepler data is referred to as data validation (DV). Herein, we describe the DV metrics and graphics used to identify viable planet candidates amongst the KOIs. Light curve modeling tests for (1) the difference in depth of the odd- versus even-numbered transits, (2) evidence of ellipsoidal variations, and (3) evidence of a secondary eclipse event at phase = 0.5. Flux-weighted centroids are used to test for signals correlated with transit events with a magnitude and direction indicative of a background eclipsing binary. Centroid time series are complimented by analysis of images taken in-transit versus out-of-transit, the difference often revealing the pixel contributing the most to the flux change during transit. Examples are shown to illustrate each test. Candidates passing DV are submitted to ground-based observers for further false-positive elimination or confirmation/characterization.

79 ASTRONOMY AND ASTROPHYSICS↗

Effective interactions in the s d shell

We perform here a quantitative study of the microscopic effective shell-model interactions in the valence sd shell, obtained from modern nucleon-nucleon potentials, chiral N3LO, JISP16 and Daejeon16, using No-Core Shell-Model wave functions and the Okubo-Lee-Suzuki transformation. We investigate the monopole properties of those interactions in comparison with the phenomenological universal sd-shell interaction, USDB. Theoretical binding energies and low-energy spectra of O isotopes and of selected sd-shell nuclei, are presented. We conclude that there is a noticeable improvement in the quality of the effective interaction when it is derived from the Daejeon16 potential. We show that its proton-neutron centroids are consistent with those from USDB. We then propose monopole modifications of the Daejeon16 centroids in order to provide an adjusted interaction yielding significantly improved agreement with the experiment. A spin-tensor decomposition of two-body effective interactions is applied in order to extract more information on the structure of the centroids and to understand the reason for deficiencies arising from our current theoretical approximations. The concern of the possible role of the three-nucleon forces is addressed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Transition sum rules in the shell model

An important characterization of electromagnetic and weak transitions in atomic nuclei are sum rules. We focus on the non-energy-weighted sum rule (NEWSR), or total strength, and the energy- weighted sum rule (EWSR); the ratio of the EWSR to the NEWSR is the centroid or average energy of transition strengths from an nuclear initial state to all allowed final states. These sum rules can be expressed as expectation values of operators, in the case of the EWSR a double commutator. While most prior applications of the double-commutator have been to special cases, we derive general formulas for matrix elements of both operators in a shell model framework (occupation space), given the input matrix elements for the nuclear Hamiltonian and for the transition operator. With these new formulas, we easily evaluate centroids of transition strength functions, with no need to calculate daughter states. We then apply this simple tool to a number of nuclides, and demonstrate the sum rules follow smooth secular behavior as a function of initial energy, as well as compare the electric dipole (E1) sum rule against the famous Thomas-Reiche-Kuhn version. We also find surprising systematic behaviors for ground state electric quadrupole (E2) centroids in the $sd$-shell.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In vivo verification of proton beam path by using post-treatment PET/CT imaging

Purpose: The purpose of this study is to establish the in vivo verification of proton beam path by using proton-activated positron emission distributions. Methods: A total of 50 PET/CT imaging studies were performed on ten prostate cancer patients immediately after daily proton therapy treatment through a single lateral portal. The PET/CT and planning CT were registered by matching the pelvic bones, and the beam path of delivered protons was defined in vivo by the positron emission distribution seen only within the pelvic bones, referred to as the PET-defined beam path. Because of the patient position correction at each fraction, the marker-defined beam path, determined by the centroid of implanted markers seen in the post-treatment (post-Tx) CT, is used for the planned beam path. The angular variation and discordance between the PET- and marker-defined paths were derived to investigate the intrafraction prostate motion. For studies with large discordance, the relative location between the centroid and pelvic bones seen in the post-Tx CT was examined. The PET/CT studies are categorized for distinguishing the prostate motion that occurred before or after beam delivery. The post-PET CT was acquired after PET imaging to investigate prostate motion due to physiological changes during the extended PET acquisition. Results: The less than 2 deg. of angular variation indicates that the patient roll was minimal within the immobilization device. Thirty of the 50 studies with small discordance, referred as good cases, show a consistent alignment between the field edges and the positron emission distributions from the entrance to the distal edge. For those good cases, average displacements are 0.6 and 1.3 mm along the anterior-posterior (D{sub AP}) and superior-inferior (D{sub SI}) directions, respectively, with 1.6 mm standard deviations in both directions. For the remaining 20 studies demonstrating a large discordance (more than 6 mm in either D{sub AP} or D{sub SI}), 13 studies, referred as motion-after-Tx cases, also show large misalignment between the field edge and the positron emission distribution in lipomatous tissues around the prostate. These motion-after-Tx cases correspond to patients with large changes in volume of rectal gas between the post-Tx and the post-PET CTs. The standard deviations for D{sub AP} and D{sub SI} are 5.0 and 3.0 mm, respectively, for these motion-after-Tx cases. The final seven studies, referred to as position-error cases, which had a large discordance but no misalignment, were found to have deviations of 4.6 and 3.6 mm in D{sub AP} and D{sub SI}, respectively. The position-error cases correspond to a large discrepancy on the relative location between the centroid and pelvic bones seen in post-Tx CT and recorded x-ray radiographs. Conclusions: Systematic analyses of proton-activated positron emission distributions provide patient-specific information on prostate motion ({sigma}{sub M}) and patient position variability ({Sigma}{sub p}) during daily proton beam delivery. The less than 2 mm of displacement variations in the good cases indicates that population-based values of {Sigma}{sub p} and {sigma}{sub M} used in margin algorithms for treatment planning at the authors' institution are valid for the majority of cases. However, a small fraction of PET/CT studies (approximately 14%) with {approx}4 mm displacement variations may require different margins. Such data are useful in establishing patient-specific planning target volume margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnitude of speed of sound aberration corrections for ultrasound image guided radiotherapy for prostate and other anatomical sites

Purpose: The purpose of this work is to assess the magnitude of speed of sound (SOS) aberrations in three-dimensional ultrasound (US) imaging systems in image guided radiotherapy. The discrepancy between the fixed SOS value of 1540 m/s assumed by US systems in human soft tissues and its actual nonhomogeneous distribution in patients produces small but systematic errors of up to a few millimeters in the positions of scanned structures. Methods: A correction, provided by a previously published density-based algorithm, was applied to a set of five prostate, five liver, and five breast cancer patients. The shifts of the centroids of target structures and the change in shape were evaluated. Results: After the correction the prostate cases showed shifts up to 3.6 mm toward the US probe, which may explain largely the reported positioning discrepancies in the literature on US systems versus other imaging modalities. Liver cases showed the largest changes in volume of the organ, up to almost 9%, and shifts of the centroids up to more than 6 mm either away or toward the US probe. Breast images showed systematic small shifts of the centroids toward the US probe with a maximum magnitude of 1.3 mm. Conclusions: The applied correction in prostate and liver cancer patients shows positioning errors of several mm due to SOS aberration; the errors are smaller in breast cancer cases, but possibly becoming more important when breast tissue thickness increases.

60 APPLIED LIFE SCIENCES↗

A patient alignment solution for lung SBRT setups based on a deformable registration technique

Purpose: In this work, the authors propose a novel registration strategy for translation-only correction scenarios of lung stereotactic body radiation therapy setups, which can achieve optimal dose coverage for tumors as well as preserve the consistency of registrations with minimal human interference. Methods: The proposed solution (centroid-to-centroidor CTC solution) uses the average four-dimensional CT (A4DCT) as the reference CT. The cone-beam CT (CBCT) is deformed to acquire a new centroid for the internal target volume (ITV) on the CBCT. The registration is then accomplished by simply aligning the centroids of the ITVs between the A4DCT and the CBCT. Sixty-seven cases using 64 patients (each case is associated with separate isocenters) have been investigated with the CTC method and compared with the conventional gray-value (G) mode and bone (B) mode registration methods. Dosimetric effects among the tree methods were demonstrated by 18 selected cases. The uncertainty of the CTC method has also been studied. Results: The registration results demonstrate the superiority of the CTC method over the other two methods. The differences in the D99 and D95 ITV dose coverage between the CTC method and the original plan is small (within 5%) for all of the selected cases except for one for which the tumor presented significant growth during the period between the CT scan and the treatment. Meanwhile, the dose coverage differences between the original plan and the registration results using either the B or G method are significant, as tumor positions varied dramatically, relative to the rib cage, from their positions on the original CT. The largest differences between the D99 and D95 dose coverage of the ITV using the B or G method versus the original plan are as high as 50%. The D20 differences between any of the methods versus the original plan are all less than 2%. Conclusions: The CTC method can generate optimal dose coverage to tumors with much better consistency compared with either the G or B method, and it is especially useful when the tumor position varies greatly from its position on the original CT, relative to the rib cage.

60 APPLIED LIFE SCIENCES↗

SU-E-J-73: Generation of Volumetric Images with a Respiratory Motion Model Based On An External Surrogate Signal

Purpose: Respiratory motion during radiotherapy treatment can differ significantly from motion observed during imaging for treatment planning. Our goal is to use an initial 4DCT scan and the trace of an external surrogate marker to generate 3D images of patient anatomy during treatment. Methods: Deformable image registration is performed on images from an initial 4DCT scan. The deformation vectors are used to develop a patient-specific linear relationship between the motion of each voxel and the trajectory of an external surrogate signal. Correlations in motion are taken into account with principal component analysis, reducing the number of free parameters. This model is tested with digital phantoms reproducing the breathing patterns of ten measured patient tumor trajectories, using five seconds of data to develop the model and the subsequent thirty seconds to test its predictions. The model is also tested with a breathing physical anthropomorphic phantom programmed to reproduce a patient breathing pattern. Results: The error (mean absolute, 95th percentile) over 30 seconds in the predicted tumor centroid position ranged from (0.8, 1.3) mm to (2.2, 4.3) mm for the ten patient breathing patterns. The model reproduced changes in both phase and amplitude of the breathing pattern. Agreement between prediction and truth over the entire image was confirmed by assessing the global voxel intensity RMS error. In the physical phantom, the error in the tumor centroid position was less than 1 mm for all images. Conclusion: We are able to reconstruct 3D images of patient anatomy with a model correlating internal respiratory motion with motion of an external surrogate marker, reproducing the expected tumor centroid position with an average accuracy of 1.4 mm. The images generated by this model could be used to improve dose calculations for treatment planning and delivered dose estimates. This work was partially funded by a research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗