Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Centers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A Chemist’s Guide to Solid-State Qubits: Diamond Color Centers as Embedded Vacancy-Centered Molecules

Diamond point defects or color centers are at the crux of solid-state quantum technology applications, from computing to sensing. Modeling molecular qubits has advanced by leaps and bounds mainly due to the advanced quantum mechanical (QM) tools in the arsenal of quantum chemists for modeling (isolated) molecular systems, which should be easily translatable for analogous systems in the solid state. Here, we simulate a series of diamond defects: a carbon vacancy (V C ) and second row substitutions that are adjacent to a V C or D C V C , with D = B, N, and O, to evaluate their magnetic and optical properties. We applied molecular orbital principles, an embedded cluster method, and a multiconfigurational QM theory to computationally characterize the above-mentioned defects for a multitude of spin, charge, and excited states. Our computational approach delivered high-quality QM insights that compare well with experiments. Furthermore, with this framework, we confirm the spin-triplets B C V C – and O C V C 0 to be analogous to N C V C – , with calculated bright transitions that respectively correspond to UV (3.80 eV) and blue (2.65 eV) light absorption and emission lifetimes (τ) of 2.3 and 5.6 ns, which are higher in energy and more short-lived (and thus brighter) than that for N C V C – : green (2.26 eV), τ = 9.5 ns.

Martirez, John Mark P. [Princeton Plasma Physics L↗

Progress in ion source injector development at the ion beam therapy center (Heidelberg Ion Beam Therapy Center)

Radiotherapy with heavy ions is an upcoming cancer treatment method with to date unachieved precision. It associates higher control rates particularly for radio-resistant tumor species with reduced adverse effects compared to conventional photon therapy. At Heidelberg Ion Beam Therapy Center two 14.5 GHz electron cyclotron resonance ion sources are routinely used to produce a variety of ion beams from protons up to oxygen. The operating time is 330 days per year; our experience after 3 yr of continuous operation will be presented, with special emphasis on stability and breakdowns of components. In addition, the latest enhancement and the results for the operation will be shown.

43 PARTICLE ACCELERATORS↗

Emission properties of body-centered cubic elemental metal photocathodes

A first principles analysis of photoemission is developed to explain the lower than expected rms transverse electron momentum measured using the solenoid scan technique for the body-centered cubic Group Vb (V, Nb, and Ta) and Group VIb (Cr, Mo, and W) metallic photocathodes. The density functional theory based analysis elucidates the fundamental role that the electronic band structure (and its dispersion) plays in determining the emission properties of solid-state photocathodes and includes evaluation of work function anisotropy using a thin-slab method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonlinear ultrasonic response of voids and Cu precipitates in body-centered cubic Fe

Interpreting nonlinear ultrasonic signals detected in nondestructive evaluation of radiation damage needs the knowledge of the correlation between defects and nonlinearity. In this work, molecular dynamics simulations are performed to study the effect of distributed vacancies, voids, Cu atoms, and Cu precipitates on nonlinear ultrasonic response in body-centered cubic (bcc) Fe. The nonlinearity parameter calculated from the second harmonic amplitude in the perfect lattice is 2.73. Vacancies are found to increase the nonlinearity. Surprisingly, clusters of vacancies in the form of spherical voids show an opposite effect. This finding can be used to conveniently distinguish vacancies from voids in the material. Unlike vacancies, individual Cu atoms decrease the nonlinearity. Clustering of Cu atoms into Cu precipitates further decrease the nonlinearity. Interestingly, precipitates with a diameter of 2 nm and larger exhibit a similar effect despite their different structure and coherency with the Fe matrix.

Setyawan, Wahyu↗

Millisecond Pulsars, TeV Halos, and Implications For The Galactic Center Gamma-Ray Excess

Observations by the High Altitude Water Cherenkov (HAWC) Observatory indicate that many young pulsars (including Geminga and Monogem) are surrounded by spatially extended, multi-TeV emitting regions. It is not currently known, however, whether TeV emission is also produced by recycled, millisecond pulsars (MSPs). In this study, we perform a stacked analysis of 24 MSPs within HAWC’s field of-view, finding between 2.6–3.1σ evidence that these sources are, in fact, surrounded by TeV halos. The efficiency with which these MSPs produce TeV halos is similar to that exhibited by young pulsars. This result suggests that several dozen MSPs will ultimately be detectable by HAWC, including many “invisible” pulsars without radio beams oriented in our direction. The TeV halos of unresolved MSPs could also dominate the TeV-scale diffuse emission observed at high galactic latitudes. We also discuss the possibility that TeV and radio observations could be used to constrain the population of MSPs that is present in the inner Milky Way, thereby providing us with a new way to test the hypothesis that MSPs are responsible for the Galactic Center GeV excess.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Imaging the Local Charge Environment of Nitrogen-Vacancy Centers in Diamond

Characterizing the local internal environment surrounding solid-state spin defects is crucial to harnessing them as nanoscale sensors of external fields. This is especially germane to the case of defect ensembles which can exhibit a complex interplay between interactions, internal fields, and lattice strain. Working with the nitrogen-vacancy (NV) center in diamond, we show that local electric fields dominate the magnetic resonance behavior of NV ensembles at a low magnetic field. We propose a simple microscopic model that quantitatively captures the observed spectra for samples with NV concentrations spanning more than two orders of magnitude. Motivated by this understanding, we propose and implement a new method for the nanoscale localization of individual charges within the diamond lattice; our approach relies upon the fact that the charge induces a NV dark state which depends on the electric field orientation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Zone-center phonons in yellow phase CsSnI 3

Here, the zone-center phonons are calculated for yellow phase CsSnI 3 using density functional perturbation theory in a plane-wave pseudopotential method. The infrared absorption and reflection spectra are simulated and show that the absorption has a strong contribution from the LO as well as TO modes. The polarization-dependent Raman spectra for various configurations are simulated. The results for the Raman and the infrared reflectionspectra are found to be in good agreement with the available experimental data when averaging over directions.The Born effective charges and high- and low-frequency dielectric tensors are calculated. The ratio of the static to the high-frequency dielectric constants is high in the y direction.

36 MATERIALS SCIENCE↗

Commissioning of the discrete spot scanning proton beam delivery system at University of Texas M.D. Anderson Cancer Center, Proton Therapy Center, Houston

Purpose: To describe a summary of the clinical commissioning of the discrete spot scanning proton beam at the Proton Therapy Center, Houston (PTC-H). Methods: Discrete spot scanning system is composed of a delivery system (Hitachi ProBeat), an electronic medical record (Mosaiq V 1.5), and a treatment planning system (TPS) (Eclipse V 8.1). Discrete proton pencil beams (spots) are used to deposit dose spot by spot and layer by layer for the proton distal ranges spanning from 4.0 to 30.6 g/cm{sup 2} and over a maximum scan area at the isocenter of 30x30 cm{sup 2}. An arbitrarily chosen reference calibration condition has been selected to define the monitor units (MUs). Using radiochromic film and ion chambers, the authors have measured spot positions, the spot sizes in air, depth dose curves, and profiles for proton beams with various energies in water, and studied the linearity of the dose monitors. In addition to dosimetric measurements and TPS modeling, significant efforts were spent in testing information flow and recovery of the delivery system from treatment interruptions. Results: The main dose monitors have been adjusted such that a specific amount of charge is collected in the monitor chamber corresponding to a single MU, following the IAEA TRS 398 protocol under a specific reference condition. The dose monitor calibration method is based on the absolute dose per MU, which is equivalent to the absolute dose per particle, the approach used by other scanning beam institutions. The full width at half maximum for the spot size in air varies from approximately 1.2 cm for 221.8 MeV to 3.4 cm for 72.5 MeV. The measured versus requested 90% depth dose in water agrees to within 1 mm over ranges of 4.0-30.6 cm. The beam delivery interlocks perform as expected, guarantying the safe and accurate delivery of the planned dose. Conclusions: The dosimetric parameters of the discrete spot scanning proton beam have been measured as part of the clinical commissioning program, and the machine is found to function in a safe manner, making it suitable for patient treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-G-BRE-07: Proton Therapy Enhanced by Tumor-Targeting Gold Nanoparticles: A Pilot in Vivo Experiment at The Proton Therapy Center at MD Anderson Cancer Center

Purpose: Assess tumor-growth delay and survival in a mouse model of prostate cancer treated with tumor-targeting gold nanoparticles (AuNPs) and proton therapy. Methods: We first examined the accumulation of targeting nanoparticles within prostate tumors by imaging AuNPs with ultrasound-guided photoacoustics at 24h after the intravenous administration of goserelin-conjugated AuNPs (gAuNP) in three mice. Nanoparticles were also imaged at the cellular level with TEM in PC3 cells incubated with gAuNP for 24h. Pegylated AuNPs (pAuNP) were also imaged in vivo and in vitro for comparison. PC3 cells were then implanted subcutaneously in nude mice; 51mice with 8–10mm tumors were included. AuNPs were injected intravenously at 0.2%w/w final gold concentration 24h before irradiation. A special jig was designed to facilitate tumor irradiation perpendicular to the proton beam. Proton energy was set to 180MeV, the radiation field was 18×18cm{sup 2}, and 9cm or 13.5cm thick solid-water compensators were used to position the tumors at either the beam entrance (BE) or the SOBP. Physical doses of 5Gy were delivered to all tumors on a patient beam line at MD Anderson's Proton Therapy Center. Results: The photoacoustic experiment reveled that our nanoparticles leak from the tumor-feeding vasculature and accumulate within the tumor volume over time. Additionally, TEM images showed gAuNP are internalized in cancer cells, accumulating within the cytoplasm, whereas pAuNP are not. Tumor-growth was delayed by 11 or 32days in mice receiving gAuNP irradiated at the BE or the SOBP, relative to proton radiation alone. Survival curves (ongoing experiment) reveal that gAuNPs improved survival by 36% or 74% for tumors irradiated at the BE or SOBP. Conclusion: These important, albeit preliminary, in vivo findings reveal nanoparticles to be potent sensitizers to proton therapy. Further, conjugation of AuNPs to tumor-specific antigens that promote enhanced cellular internalization improved both tumor-growth delay and survival of mice after proton therapy.

60 APPLIED LIFE SCIENCES↗

Measurement of multi-jet cross sections in proton–proton collisions at a 7 TeV center-of-mass energy

Inclusive multi-jet production is studied in proton–proton collisions at a center-of-mass energy of 7 TeV, using the ATLAS detector. The data sample corresponds to an integrated luminosity of 2.4 pb -1 . Results on multi-jet cross sections are presented and compared to both leading-order plus parton-shower Monte Carlo predictions and to next-to-leading-order QCD calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the jet fragmentation function and transverse profile in proton–proton collisions at a center-of-mass energy of 7 TeV with the ATLAS detector

The jet fragmentation function and transverse profile for jets with 25 GeV < p T jet < 500 GeV and |η jet | < 1.2 produced in proton–proton collisions with a center-of-mass energy of 7 TeV are presented. The measurement is performed using data with an integrated luminosity of 36 pb –1 . Jets are reconstructed and their momentum measured using calorimetric information. The momenta of the charged particle constituents are measured using the tracking system. The distributions corrected for detector effects are compared with various Monte Carlo event generators and generator tunes. Several of these choices show good agreement with the measured fragmentation function. Furthermore, none of these choices reproduce both the transverse profile and fragmentation function over the full kinematic range of the measurement.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗