Interface Box for Dual Power Amplifier Modulators in Main Injector

The Proton Improvement Plan II (PIP-II) aims to enhance the current Fermilab particle accelerator complex to intensify and accelerate more beam. To achieve this, a second power amplifier will be added to the Main Injector (MI) cavities. However, the control unit could only read signals coming from the previous power supplies, so the interface box was designed to facilitate the issue.

Ayala, Diana↗

NASA communications technology research and development

The development of a 1978 NASA study to identify technology requirements is surveyed, and its principal conclusions, recommendations, and priorities are summarized. In addition, antenna, traveling wave tube, and solid state amplifier developments representing selected items from the current communications technology development programs at the NASA Lewis Research and Goddard Space Flight Centers are described.

Durham, A. F.↗

Study of mid IR fiber transmission and mode patterns under laser induced stimulated Brillouin scattering

Mid IR fiber transmission and exit radiation mode patterns at various incident CO2 laser power levels appear to be effective diagnostic tools for monitoring laser induced stimulated Brillouin scattering in various mid IR fibers. Such processes are deemed to be essential mechanisms for fiber-optic amplifiers and switches as potential replacements of current repeaters and bistable devices.

Yu, C.↗

1.54 micron Emission from Erbium implanted GaN for Photonic Applications

The development of efficient and compact light sources operating at 1.54 micron is of enormous importance for the advancement of new optical communication systems. Erbium (1%) doped fiber amplifiers (EDFA's) or semiconductor lasers are currently being employed as near infrared light sources. Both devices, however, have inherent limitations due to their mode of operation. EDFA's employ an elaborate optical pumping scheme, whereas diode lasers have a strongly temperature dependent lasing wavelength. Novel light emitters based on erbium doped III-V semiconductors could overcome these limitations. Er doped semiconductors combine the convenience of electrical excitation with the excellent luminescence properties of Er(3+) ions. Electrically pumped, compact, and temperature stable optoelectronic devices are envisioned from this new class of luminescent materials. In this paper we discuss the potential of Er doped GaN for optoelectronic applications based on temperature dependent photoluminescence excitation studies.

Thaik, Myo↗

Power-Combined GaN Amplifier with 2.28-W Output Power at 87 GHz

Future remote sensing instruments will require focal plane spectrometer arrays with higher resolution at high frequencies. One of the major components of spectrometers are the local oscillator (LO) signal sources that are used to drive mixers to down-convert received radio-frequency (RF) signals to intermediate frequencies (IFs) for analysis. By advancing LO technology through increasing output power and efficiency, and reducing component size, these advances will improve performance and simplify architecture of spectrometer array systems. W-band power amplifiers (PAs) are an essential element of current frequency-multiplied submillimeter-wave LO signal sources. This work utilizes GaN monolithic millimeter-wave integrated circuit (MMIC) PAs developed from a new HRL Laboratories LLC 0.15- m gate length GaN semiconductor transistor. By additionally waveguide power combining PA MMIC modules, the researchers here target the highest output power performance and efficiency in the smallest volume achievable for W-band.

Fung, King Man↗

Single Pixel Characterization of X-Ray TES Microcalorimeter Under AC Bias at MHz Frequencies

In this paper we present the progress made at SRON in the read-out of GSFC x-ray transition-edge sensor (TES) micro-calorimeters in the frequency domain. The experiments reported so far, whose aim was to demonstrate an energy resolution of 2eV at 6 keV with a TES acting as a modulator, were carried out at frequencies below 700 kHz using a standard flux locked loop (FLL) SQUID read-out scheme. The TES read-out suffered from the use of sub-optimal circuit components, large parasitic inductances, low quality factor resonators and poor magnetic field shielding. We have developed a novel experimental set-up, which allows us to test several read-out schemes in a single cryogenic run. In this set-up, the TES pixels are coupled via superconducting transformers to 18 high-Q lithographic LC filters with resonant frequencies ranging between 2 and 5 MHz. The signal is amplified by a two-stage SQUID current sensor and baseband feedback is used to overcome the limited SQUID dynamic range. We study the single pixel performance as a function of TES bias frequency, voltage and perpendicular magnetic field.

Gottardi, L.↗

Failure of Nd:YVO4 Amplifier Crystals

Brittle single crystals are used in NASA applications ranging from lenses to centrally heated laser slabs. Despite standard procedures to design such components, unexpected failures occasionally occur. The ICEsat-2 (Ices,Cloud, and Elevation satellite-2) employs Yttrium orthovanadate single crystals in laser amplifiers and oscillators. Although the systems are currently flying and successfully operating, some unexpected crystal fractures occurred just prior to flight. The failures were traced to poor crystal quality along with time-dependent chemical reaction within the system assembly that increased stress beyond expectations and promoted both fast fracture and stress corrosion. This presentation will discuss failure analysis of the crystals and the chemical reactions that promoted failures, along with corrective actions taken to reduce likelihood of fracture over the three-year mission. Re-designed lasers were stored for 12 months and operated for a total of 1,000 hours without signs of degradation.

Design↗

Failure of Nd:YVO4 Amplifier Crystals

Brittle single crystals are used in NASA applications ranging from lenses to centrally heated laser slabs. Despite standard procedures to design such components, unexpected failures occasionally occur. The ICEsat-2 (Ices, cloud, and elevation satellite) employs Yttrium orthovanadate single crystals in laser amplifiers and oscillators. Although the systems are currently flying and successfully operating, some unexpected crystal fractures occurred just prior to flight. The failures were traced to poor crystal quality along with time depend chemical reaction within the system assembly that increased stress beyond expectations and promoted both fast fracture and stress corrosion. This presentation will discuss failure analysis of the crystals and the chemical reactions that promoted failures, along with corrective actions taken to reduce likelihood of fracture over the three year mission. Re-designed lasers were stored for 12 months and operated for a total of 1,000 hours without signs of degradation.

Salem, Jon↗

Interface Box for Dual Power Amplifier Modulators in Main Injector

The Proton Improvement Plan II (PIP-II) aims to enhance the current Fermilab particle accelerator complex to intensify and accelerate more beam. To achieve this, a second power amplifier will be added to the Main Injector (MI) cavities. However, the control unit could only read signals coming from the previous power supplies, so the interface box was designed to facilitate the issue.

Ayala, Diana↗

Magnetically Controlled Variable Transformer

Improved variable-transformer circuit, output voltage and current of which controlled by use of relatively small current supplied at relatively low power to control windings on its magnetic cores. Transformer circuits of this type called "magnetic amplifiers" because ratio between controlled output power and power driving control current of such circuit large. This ratio - power gain - can be as large as 100 in present circuit. Variable-transformer circuit offers advantages of efficiency, safety, and controllability over some prior variable-transformer circuits.

Kleiner, Charles T.↗

Design of a Torque Current Generator for Strapdown Gyroscopes

The design, analysis, and experimental evaluation of an optimum performance torque current generator for use with strapdown gyroscopes, is presented. Among the criteria used to evaluate the design were the following: (1) steady-state accuracy; (2) margins of stability against self-oscillation; (3) temperature variations; (4) aging; (5) static errors drift errors, and transient errors, (6) classical frequency and time domain characteristics; and (7) the equivalent noise at the input of the comparater operational amplifier. The DC feedback loop of the torque current generator was approximated as a second-order system. Stability calculations for gain margins are discussed. Circuit diagrams are shown and block diagrams showing the implementation of the torque current generator are discussed.

Mcknight, R. D.↗

LC-oscillator with automatic stabilized amplitude via bias current control

A stable excitation supply for measurement transducers is described. It consists of a single-transistor oscillator with a coil connected to the collector and a capacitor connected from the collector to the emitter. The output of the oscillator is rectified and the rectified signal acts as one input to a differential amplifier; the other input being a reference potential. The output of the amplifier is connected at a point between the emitter of the transistor and ground. When the rectified signal is greater than the reference signal, the differential amplifier produces a signal of polarity to reduce bias current and, consequently, amplification.

Hamlet, J. F.↗

Ballistic-Electron-Emission Microscope

Ballistic-electron-emission microscope (BEEM) employs scanning tunneling-microscopy (STM) methods for nondestructive, direct electrical investigation of buried interfaces, such as interface between semiconductor and thin metal film. In BEEM, there are at least three electrodes: emitting tip, biasing electrode, and collecting electrode, receiving current crossing interface under investigation. Signal-processing device amplifies electrode signals and converts them into form usable by computer. Produces spatial images of surface by scanning tip; in addition, provides high-resolution images of buried interface under investigation. Spectroscopic information extracted by measuring collecting-electrode current as function of one of interelectrode voltages.

Kaiser, William J.↗

Progress and Plans for a US Laser System for the LISA Mission

NASA Goddard Space Flight Center is developing a master oscillator power amplifier (MOPA) laser transmitter for the ESA-led Laser Interferometer Space Antenna (LISA) mission. Taking advantage of our space laser experience and the emerging telecom laser technology, we are developing a full laser system for the LISA mission. Our research effort has included both master oscillator (MO) and power amplifier (PA) developments, and their environmental testing and reliability for space flight. Our current baseline for the MO is a low-mass, compact micro NPRO (m-NPRO) laser. The amplifier uses a robust mechanical design based on fiber components. We have performed laser system noise tests by amplitude- and frequency-stabilizing the PA output. We will describe our progress and plans to demonstrate a TRL 6 laser system, which is an essential step toward qualifying lasers for space applications, by 2021.

lasers↗

Precision calibration and reference voltage source for data acquisition systems

Hybrid integrated circuit operational amplifiers, which have inherent characteristics of low quiescent power dissipation and extended operational lifetime with high reliability, are source for digital systems. Amplifiers are coupled to Zener reference diode in current control and buffer configuration.

Source record↗

Effect of ice-albedo feedback on global sensitivity in a one-dimensional radiative-convective climate model

The feedback between the ice albedo and temperature is included in a one-dimensional radiative-convective climate model. The effect of this feedback on global sensitivity to changes in solar constant is studied for the current climate conditions. This ice-albedo feedback amplifies global sensitivity by 26 and 39%, respectively, for assumptions of fixed cloud altitude and fixed cloud temperature. The global sensitivity is not affected significantly if the latitudinal variations of mean solar zenith angle and cloud cover are included in the global model. The differences in global sensitivity between one-dimensional radiative-convective models and energy balance models are examined. It is shown that the models are in close agreement when the same feedback mechanisms are included. The one-dimensional radiative-convective model with ice-albedo feedback included is used to compute the equilibrium ice line as a function of solar constant.

Wang, W.-C.↗