Monitoring ABC-assisted deep inspiration breath hold for left-sided breast radiotherapy with an optical tracking system

Purpose: Recent knowledge on the effects of cardiac toxicity warrants greater precision for left-sided breast radiotherapy. Different breath-hold (BH) maneuvers (abdominal vs thoracic breathing) can lead to chest wall positional variations, even though the patient’s tidal volume remains consistent. This study aims to investigate the feasibility of using optical tracking for real-time quality control of active breathing coordinator (ABC)-assisted deep inspiration BH (DIBH). Methods: An in-house optical tracking system (OTS) was used to monitor ABC-assisted DIBH. The stability and localization accuracy of the OTS were assessed with a ball-bearing phantom. Seven patients with left-sided breast cancer were included. A free-breathing (FB) computed tomography (CT) scan and an ABC-assisted BH CT scan were acquired for each patient. The OTS tracked an infrared (IR) marker affixed over the patient’s xiphoid process to measure the positional variation of each individual BH. Using the BH within which the CT scan was performed as the reference, the authors quantified intra- and interfraction BH variations for each patient. To estimate the dosimetric impact of BH variations, the authors studied the positional correlation between the marker and the left breast using the FB CT and BH CT scans. The positional variations of 860 BHs as measured by the OTS were retrospectively incorporated into the original treatment plans to evaluate their dosimetric impact on breast and cardiac organs [heart and left anterior descending (LAD) artery]. Results: The stability and localization accuracy of the OTS was within 0.2 mm along each direction. The mean intrafraction variation among treatment BHs was less than 2.8 mm in all directions. Up to 12.6 mm anteroposterior undershoot, where the patient’s chest wall displacement of a BH is less than that of a reference BH, was observed with averages of 4.4, 3.6, and 0.1 mm in the anteroposterior, craniocaudal, and mediolateral directions, respectively. A high positional correlation between the marker and the breast was found in the anteroposterior and craniocaudal directions with respective Pearson correlation values of 0.95 and 0.93, but no mediolateral correlation was found. Dosimetric impact of BH variations on breast coverage was negligible. However, the mean heart dose, mean LAD dose, and max LAD dose were estimated to increase from 1.4/7.4/18.6 Gy (planned) to 2.1/15.7/31.0 Gy (delivered), respectively. Conclusions: In ABC-assisted DIBH, large positional variation can occur in some patients, due to their different BH maneuvers. The authors’ study has shown that OTS can be a valuable tool for real-time quality control of ABC-assisted DIBH.

60 APPLIED LIFE SCIENCES↗

{sup 18}F-FDG PET-CT Simulation for Non-Small-Cell Lung Cancer: Effect in Patients Already Staged by PET-CT

Purpose: Positron emission tomography (PET), in addition to computed tomography (CT), has an effect in target volume definition for radical radiotherapy (RT) for non-small-cell lung cancer (NSCLC). In previously PET-CT staged patients with NSCLC, we assessed the effect of using an additional planning PET-CT scan for gross tumor volume (GTV) definition. Methods and Materials: A total of 28 patients with Stage IA-IIIB NSCLC were enrolled. All patients had undergone staging PET-CT to ensure suitability for radical RT. Of the 28 patients, 14 received induction chemotherapy. In place of a RT planning CT scan, patients underwent scanning on a PET-CT scanner. In a virtual planning study, four oncologists independently delineated the GTV on the CT scan alone and then on the PET-CT scan. Intraobserver and interobserver variability were assessed using the concordance index (CI), and the results were compared using the Wilcoxon signed ranks test. Results: PET-CT improved the CI between observers when defining the GTV using the PET-CT images compared with using CT alone for matched cases (median CI, 0.57 for CT and 0.64 for PET-CT, p = .032). The median of the mean percentage of volume change from GTV{sub CT} to GTV{sub FUSED} was -5.21% for the induction chemotherapy group and 18.88% for the RT-alone group. Using the Mann-Whitney U test, this was significantly different (p = .001). Conclusion: PET-CT RT planning scan, in addition to a staging PET-CT scan, reduces interobserver variability in GTV definition for NSCLC. The GTV size with PET-CT compared with CT in the RT-alone group increased and was reduced in the induction chemotherapy group.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A support vector machine (SVM) for predicting preferred treatment position in radiotherapy of patients with breast cancer

Purpose: NYU 05-181 protocol compared the CT simulation in both supine and prone positions for 400 patients with breast cancer (200 left-breast and 200 right-breast) to identify which setup is better at sparing heart and lung involvement in the treatment process. The results demonstrated that all right-breast patients benefited from the prone treatment position, while for left-breast patients, 85% were better treated prone and 15% were better treated supine. Using the clinical data collected from this protocol, the authors aimed at developing an automated tool capable of identifying which of the left-breast cancer patients are better treated supine without obtaining a second CT scan in the supine position. Methods: Prone CT scans from 198 of the 200 left-breast cancer patients enrolled in NYU 05-181 protocol were deidentified and exported to a dedicated research planning workstation. Three-dimensional geometric features of the organs at risk and tumor bed were extracted. A two-stage classifier was used to classify patients into the prone class or the supine class. In the first stage, the authors use simple thresholding to divide the patients into two groups based on their in-field heart volume. For patients with in-field heart volume {<=}0.1 cc, the prone position was chosen as the preferred treatment position. Patients with in-field heart volume >0.1 cc will be further classified in the second stage by a weighted support vector machine (SVM). The weight parameters of the SVM were adjusted to maximize the specificity [true-supine/(true-supine+false-prone)] at the cost of lowering but still maintaining reasonable sensitivity [true-prone/(true-prone+false-supine)]. The authors used K-fold cross validations to test the performance of the SVM classifier. A feature selection algorithm was also used to identify features that give the best classification performance. Results: After the first stage, 49 of the 198 left-breast cancer patients were found to have >0.1 cc of in-field heart volume. The three geometric features of heart orientation, distance between heart and tumor, and in-field lung were selected by the feature selection algorithm in the second stage of the two-stage classifier to give the best predefined weighted accuracy. The overall sensitivity and specificity of the proposed method were found to be 90.4% and 99.3%, respectively. Using two-stage classification, the authors reduced the proportion of prone-treated patients that need a second supine CT scan down to 16.3/170 or 9.6%, as compared to 21/170 or 12.4% when the authors use only the first stage (thresholding) for classification. Conclusions: The authors' study showed that a feature-based classifier is feasible for predicting the preferred treatment position, based on features extracted from prone CT scans. The two-stage classifier achieved very high specificity at an acceptable expense of sensitivity.

60 APPLIED LIFE SCIENCES↗

Evaluation of a semiautomated lung mass calculation technique for internal dosimetry applications

Purpose: The authors sought to evaluate a simple, semiautomated lung mass estimation method using computed tomography (CT) scans obtained using a variety of acquisition techniques and reconstruction parameters for mass correction of medical internal radiation dose-based internal radionuclide radiation absorbed dose estimates.Methods: CT scans of 27 patients with lung cancer undergoing stereotactic body radiation therapy treatment planning with PET/CT were analyzed retrospectively. For each patient, free-breathing (FB) and respiratory-gated 4DCT scans were acquired. The 4DCT scans were sorted into ten respiratory phases, representing one complete respiratory cycle. An average CT reconstruction was derived from the ten-phase reconstructions. Mid expiration breath-hold CT scans were acquired in the same session for many patients. Deep inspiration breath-hold diagnostic CT scans of many of the patients were obtained from different scanning sessions at similar time points to evaluate the effect of contrast administration and maximum inspiration breath-hold. Lung mass estimates were obtained using all CT scan types, and intercomparisons made to assess lung mass variation according to scan type. Lung mass estimates using the FB CT scans from PET/CT examinations of another group of ten male and ten female patients who were 21–30 years old and did not have lung disease were calculated and compared with reference lung mass values. To evaluate the effect of varying CT acquisition and reconstruction parameters on lung mass estimation, an anthropomorphic chest phantom was scanned and reconstructed with different CT parameters. CT images of the lungs were segmented using the OsiriX MD software program with a seed point of about −850 HU and an interval of 1000. Lung volume, and mean lung, tissue, and air HUs were recorded for each scan. Lung mass was calculated by assuming each voxel was a linear combination of only air and tissue. The specific gravity of lung volume was calculated using the formula (lung HU − air HU)/(tissue HU − air HU), and mass = specific gravity × total volume × 1.04 g/cm{sup 3}.Results: The range of calculated lung masses was 0.51–1.29 kg. The average male and female lung masses during FB CT were 0.80 and 0.71 kg, respectively. The calculated lung mass varied across the respiratory cycle but changed to a lesser degree than did lung volume measurements (7.3% versus 15.4%). Lung masses calculated using deep inspiration breath-hold and average CT were significantly larger (p < 0.05) than were some masses calculated using respiratory-phase and FB CT. Increased voxel size and smooth reconstruction kernels led to high lung mass estimates owing to partial volume effects.Conclusions: Organ mass correction is an important component of patient-specific internal radionuclide dosimetry. Lung mass calculation necessitates scan-based density correction to account for volume changes owing to respiration. The range of lung masses in the authors’ patient population represents lung doses for the same absorbed energy differing from 25% below to 64% above the dose found using reference phantom organ masses. With proper management of acquisition parameters and selection of FB or midexpiration breath hold scans, lung mass estimates with about 10% population precision may be achieved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microbial Community Characteristics Largely Unaffected by X-Ray Computed Tomography of Sediment Cores

X-ray computed tomography (CT) scanning is used to study the physical characteristics of soil and sediment cores, allowing scientists to analyze stratigraphy without destroying core integrity. Microbiologists often work with geologists to understand the microbial properties in such cores; however, we do not know whether CT scanning alters microbial DNA such that DNA sequencing, a common method of community characterization, changes as a result of X-ray exposure. Our objective was to determine whether CT scanning affects the estimates of the composition of microbial communities that exist in cores. Sediment cores were extracted from a salt marsh and then submitted for CT scanning. We observed a minimal effect of CT scanning on microbial community composition in the sediment cores either when the cores were examined shortly after recovery from the field or after the cores had been stored for several weeks. In contrast, properties such as sediment layer and marsh location did affect microbial community structure. While we observed that CT scanning did not alter microbial community composition as a whole, we identified a few amplicon sequence variants (13 out of 7,037) that showed differential abundance patterns between scanned and unscanned samples among paired sample sets. Our overall conclusion is that the CT-scanning conditions typically used to obtain images for geological core characterization do not significantly alter microbial community structure. We stress that minimizing core exposure to X-rays is important if cores are to be studied for biological properties. Future investigations might consider variables, such as the length and energy of radiation exposure, the volume of the core, or the degree, to which microbial communities are stressed as important factors in assessing the impact of X-rays on microbes in geological cores.

59 BASIC BIOLOGICAL SCIENCES↗

SU-F-T-123: The Simulated Effect of the Breath-Hold Reproducibility Treating Locally-Advanced Lung Cancer with Pencil Beam Scanned Proton Therapy

Purpose: The breath-hold (BH) technique has been suggested to mitigate motion and reduce target coverage degradation due to motion effects. The aim of this study was to investigate the effect of inter-BH residual motion on the dose distribution for pencil beam scanned (PBS) proton therapy of locally-advanced lung cancer patients. Methods: A dataset of visually-guided BH CT scans was acquired (10 scans per patient) taken from five lung cancer patients: three intra-fractionally repeated CT scans on treatment days 2,16 and 31, in addition to the day 0 planning CT scan. Three field intensity-modulated proton therapy (IMPT) plans were constructed on the planning CT scan. Dose delivery on fraction 2, 16 and 31 were simulated on the three consecutive CT scans, assuming BH duration of 20s and soft tissue match. The dose was accumulated in the planning CT using deformable image registration, and scaled to simulate the full treatment of 66Gy(RBE) in 33 fractions. Results: The mean dose to the lungs and heart, and maximum dose to the spinal cord and esophagus were within 1% of the planned dose. The CTV V95% decreased and the inhomogeneity (D5%–D95%) increased on average 4.1% (0.4–12.2%) and 5.8% (2.2–13.4%), respectively, over the five patient cases. Conclusion: The results showed that the BH technique seems to spare the OARs in spite of inter-BH residual motion. However, small degradation of target coverage occurred for all patients, with 3/5 patients having a decrease in V95% ≤1%. For the remaining two patients, where V95% decreased up to 12%, the cause could be related to treatment related anatomical changes and, as in photon therapy, plan adaptation may be necessary to ensure target coverage. This study showed that BH could be a potential treatment option to reliably mitigate motion for the treatment of locally-advanced lung cancer using PBS proton therapy.

60 APPLIED LIFE SCIENCES↗

Complications in CT-guided Procedures: Do We Really Need Postinterventional CT Control Scans?

Purpose: The aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans. Methods: Retrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only. Results: The complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % in drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21). Conclusion: Complications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional surface reconstruction for industrial computed tomography

Modern high resolution medical computed tomography (CT) scanners can produce geometrically accurate sectional images of many types of industrial objects. Computer software has been developed to convert serial CT scans into a three-dimensional surface form, suitable for display on the scanner itself. This software, originally developed for imaging the skull, has been adapted for application to industrial CT scanning, where serial CT scans thrrough an object of interest may be reconstructed to demonstrate spatial relationships in three dimensions that cannot be easily understood using the original slices. The methods of three-dimensional reconstruction and solid modeling are reviewed, and reconstruction in three dimensions from CT scans through familiar objects is demonstrated.

Vannier, M. W.↗

Magnetic Resonance Imaging in Postprostatectomy Radiotherapy Planning

Purpose: To investigate whether the use of magnetic resonance imaging (MRI) in prostate bed treatment planning could influence definition of the clinical target volume (CTV) and organs at risk. Methods and Materials: A total of 21 consecutive patients referred for prostate bed radiotherapy were included in the present retrospective study. The CTV was delineated according to the European Organization for Research and Treatment of Cancer recommendations on computed tomography (CT) and T{sub 1}-weighted (T{sub 1}w) and T{sub 2}-weighted (T{sub 2}w) MRI. The CTV magnitude, agreement, and spatial differences were evaluated on the planning CT scan after registration with the MRI scans. Results: The CTV was significantly reduced on the T{sub 1}w and T{sub 2}w MRI scans (13% and 9%, respectively) compared with the CT scans. The urinary bladder was drawn smaller on the CT scans and the rectum was smaller on the MRI scans. On T{sub 1}w MRI, the rectum and urinary bladder were delineated larger than on T{sub 2}w MRI. Minimal agreement was observed between the CT and T{sub 2}w images. The main spatial differences were measured in the superior and superolateral directions in which the CTV on the MRI scans was 1.8-2.9 mm smaller. In the posterior and inferior border, no difference was seen between the CT and T{sub 1}w MRI scans. On the T{sub 2}w MRI scans, the CTV was larger in these directions (by 1.3 and 1.7 mm, respectively). Conclusions: The use of MRI in postprostatectomy radiotherapy planning resulted in a reduction of the CTV. The main differences were found in the superior part of the prostate bed. We believe T{sub 2}w MRI enables more precise definition of prostate bed CTV than conventional planning CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Arterial Embolization with N-Butyl-2-Cyanoacrylate in the Management of Spontaneous Hematomas

IntroductionSpontaneous hematoma refractory to conservative management is a potentially serious condition that requires prompt diagnosis and intervention. The purpose of this study was to evaluate the performance of computed tomography (CT) in the treatment planning and to report the effectiveness of transcatheter embolization with N-butyl-2-cyanoacrylate (NBCA).Materials and MethodsForty-one interventions in 38 patients within a 12-year period were evaluated. CT and angiograms were reviewed for the location of the hematoma, the presence of extravasation, and the correlation of CT and angiography findings.ResultsArterial extravasation was present on 34/39 CT scans. Angiograms confirmed the CT scans in 29 cases. Angiograms revealed extravasation in four cases which CT showed venous bleeding (n = 2) or no bleeding (n = 2). Five patients with arterial and 1 patient with venous extravasation on CT images had no extravasation on angiograms. Embolization was performed to all arteries with extravasation on angiograms. Empiric embolization of the corresponding artery on the CT was performed when there was no extravasation on angiograms. Embolization procedures were performed with 15 % NBCA diluted with iodized oil. Technical success was achieved in 40/41 (97.6 %) interventions. Clinical success was achieved in 35 patients with a single, in 1 patient with 2, and in 1 patient with 3 interventions. No complications related to embolization procedure occurred. None of the patients died due to a progression of the hematoma.ConclusionNBCA is an effective and safe embolic agent to treat hematoma refractory to conservative management. Contrast-enhanced CT may provide faster and more effective intervention.Level of Evidence IIIRetrospective.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric implications of residual seminal vesicle motion in fiducial-guided intensity-modulated radiotherapy for prostate cancer

To determine whether residual interfraction seminal vesicle (SV) displacement necessitates specific planning target volume (PTV) margins during fiducial-guided intensity modulated radiation therapy (IMRT) of the prostate. A planning computed tomography (CT) scan and 2 subsequent CT scans were prospectively obtained for 20 prostate cancer patients with intraprostatic fiducial markers. After CT registration, SV displacement relative to the prostate was quantified as a function of margin size for both the proximal (1 cm) SV (PSV) and the full SV (FSV). Two IMRT plans were simulated for each patient (prostate + PSV and prostate + FSV) both with a uniform 5-mm PTV margin. Minimum clinical target volume (CTV) dose (D{sub min}) and the volume of SV receiving 95% of the prescription dose (V{sub 95%}) were assessed during treatment and compared with the initial plan. In all cases, SV displacement with respect to the prostate was greater for the FSV compared with the PSV. To ensure at least 95% geometrical coverage of the CTV for 90% of patients, margins of 5 and 8 mm were required for the PSV and FSV, respectively. Dosimetrically, residual SV displacement had minimal impact on PSV coverage compared with FSV coverage. For the PSV D{sub min} was {>=}95% of the prescribed dose in 90% of patients with an overall mean V{sub 95%} of 99.6 {+-} 0.8%; for the FSV D{sub min} was {>=}95% of the prescribed dose in only 45% of patients with a mean V{sub 95%} of 97.9 {+-} 2.4%. The SVs move differentially from the prostate and exhibit greater variation with increasing distance from the prostate. For plans targeting just the prostate and PSVs, 5-mm PTV expansions are adequate. However, despite daily localization of the prostate, larger PTV margins are required for cases where the intent is to completely cover the FSV.

61 RADIATION PROTECTION AND DOSIMETRY↗

Materials Identification System for 200 liter/55 gallon Waste Drums using Computer Tomographic Techniques - 17162

In 2014 a thermal runaway event within a drum in-situ at the Waste Isolation Pilot Plant (WIPP) facility near Carlsbad, NM, resulted in the drum being breached and activity released. This emphasized the need for a better determination of drum contents and identification of material combinations and in-drum conditions. Enhanced characterization is required to identify and quantify the presence of absorbent materials, determine whether they are organic or inorganic, locate their position in the drum with respect to other materials, and quantify how much liquid is being held in the absorbent material. As part of the waste characterization process to ensure compliance with the WIPP waste acceptance criteria, drums are currently inspected by Real Time Radioscopic (RTR) x-ray to identify prohibited items such as free liquids and un-punctured aerosol cans, but that technique cannot satisfy these newly identified requirements, and a new approach to non-destructive examination was required. This approach complements the current RTR inspection with Cone-Beam Area Detector Computed Tomography (CT) scanning of the whole drum, followed by more-quantitative CT scanning of specific areas of concern, using a highly collimated Linear Detector Array. The density of representative waste drums required x-ray energies of up to 9 MeV, which meant that sorting of materials by their photo-electric absorption is not viable as this occurs in the 80 - 180 keV range. However, a notable characteristic of higher energy imaging in this context is the general correspondence between material density and total attenuation in the 1.5-4.0 MeV range due to Compton Scatter. Development of the imaging chain, comprising the x-ray source and the detectors was critical to achieving the required system performance. Theoretical analysis of the energy spectra of the 9 MeV beam, and filtration of the beam to remove the lower energies which cause beam hardening artifacts in the image was required. Theoretical evaluation of the required efficiency and image acquisition performance of area detectors and linear array detectors, was carried out to complete the selection of equipment. A system of density calibration rods was designed and, together with the selected equipment, was configured and used to acquire cone-beam CT data and line-scan CT data by scanning a 55 gallon drum containing surrogate waste. From the acquired data, CT reconstruction was performed and the basis of algorithms to identify materials were developed. Following this, a series of blind tests were done using a range of surrogate materials the contents of which were unknown to the system operators. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-T-09: A Dosimetric Analysis of Various Clinically Used Bolus Materials

Purpose: To evaluate the dosimetric effect of various clinically used bolus materials. Methods: Materials investigated include solid water, superflab, wet gauze, wet sheets, Play-Doh{sup ™}, and gauze embedded with petroleum jelly. Each bolusing material was scanned in a Philips CT to determine the Hounsfield unit (HU) and to verify uniformity throughout the material. Using the corresponding HU, boluses of 0.5 cm and 1.0 cm thicknesses were created in the Eclipse treatment planning system (TPS) on a solid water phantom. Dose was calculated at various depths for beam energies 6 MV, 6 MeV, 9 MeV, and 12 MeV to determine the effects of each material on deposition of dose. In addition, linac-based measurements at these energies were made using a farmer chamber in solid water. Wet sheets and wet gauze were measured with various water content to quantify the effects on dose. Results: Preliminary CT scans find a range in HU of bolus materials from −120 to almost 300. There is a trend in the dose at depth based on the HU of the material; however inconsistencies are found when the bolus materials have a negative HU value. The measured data indicates that there is a linear relationship between the mass of water in a material and the dose reading, the slope of which is material dependent. Conclusion: Due to the variation in HU of the bolus materials studied, it is recommended that any new bolus be evaluated before clinical use to determine physical and dosimetric properties. If possible, patients should have bolus included in their CT scans; or if the bolus is created in the TPS, the HU should correspond to the material used. For water-soaked materials, once the bolus material is selected (gauze or sheet), the bolusing effect is only dependent on the amount of water applied to the material.

60 APPLIED LIFE SCIENCES↗

TU-F-CAMPUS-J-04: Setup Uncertainties in the Mediastinum Area for IMRT Treatment of Lymphoma Patients

Purpose: Despite daily image guidance setup uncertainties can be high when treating large areas of the body. The aim of this study was to measure local uncertainties inside the PTV for patients receiving IMRT to the mediastinum region. Methods: Eleven lymphoma patients that received radiotherapy (breath-hold) to the mediastinum were included in this study. The treated region could range all the way from the neck to the diaphragm. Each patient had a CT scan with a CT-on-rails system prior to every treatment. The entire PTV region was matched to the planning CT using automatic rigid registration. The PTV was then split into 5 regions: neck, supraclavicular, superior mediastinum, upper heart, lower heart. Additional auto-registrations for each of the 5 local PTV regions were performed. The residual local setup errors were calculated as the difference between the final global PTV position and the individual final local PTV positions for the AP, SI and RL directions. For each patient 4 CT scans were analyzed (1 per week of treatment). Results: The residual mean group error (M) and standard deviation of the inter-patient (or systematic) error (Σ) were lowest in the RL direction of the superior mediastinum (0.0mm and 0.5mm) and highest in the RL direction of the lower heart (3.5mm and 2.9mm). The standard deviation of the inter-fraction (or random) error (σ) was lowest in the RL direction of the superior mediastinum (0.5mm) and highest in the SI direction of the lower heart (3.9mm) The directionality of local uncertainties is important; a superior residual error in the lower heart for example keeps it in the global PTV. Conclusion: There is a complex relationship between breath-holding and positioning uncertainties that needs further investigation. Residual setup uncertainties can be significant even under daily CT image guidance when treating large regions of the body.

60 APPLIED LIFE SCIENCES↗

Interobserver Variation of Clinical Target Volume Delineation in Gastric Cancer

Purpose: To evaluate interobserver variability in clinical target volume (CTV) delineation in gastric cancer performed with the help of a delineation guide. Patients and Methods: Ten radiotherapy centers that participate in the CRITICS Phase III trial were provided with a delineation atlas, preoperative CT scans, a postoperative planning CT scan, and clinical information for a gastric cancer case and were asked to construct a CTV and create a dosimetric plan according to departmental policy. Results: The volumes of the CTVs and planning target volumes (PTVs) differed greatly, with a mean (SD) CTV volume of 392 (176) cm{sup 3} (range, 240-821cm{sup 3}) and PTV volume of 915 (312) cm{sup 3} (range, 634-1677cm{sup 3}). The overlapping volume was 376cm{sup 3} for the CTV and 890cm{sup 3} for the PTV. The greatest differences in the CTV were seen at the cranial and caudal parts. After planning, dose coverage of the overlapping PTV volume showed less variability than the CTV. Conclusion: In this series of 10 plans, variability of the CTV in postoperative chemoradiotherapy for gastric cancer is large. Strict and clear delineation guidelines should be provided, especially in Phase III multicenter studies. Adaptations of these guidelines should be evaluated in clinical studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Addition of SPECT/CT Lymphoscintigraphy to Breast Cancer Radiation Planning Spares Lymph Nodes Critical for Arm Drainage

Background: This prospective cohort study was designed to determine whether the amount of radiation delivered to the nonpathological lymph nodes (LNs) that drain the arm can be significantly reduced by integrating single-photon emission computed tomography (SPECT)/computed tomography (CT) scans into radiation treatment planning. Methods: SPECT-CT scans were acquired for the 28 patients with stage I or II breast cancer and fused with the routinely obtained radiation oncology planning CT scans. Arm-draining LNs were contoured with 0.5-cm margins automatically using a threshold of 50% maximum intensity. Two treatment plans were generated: 1 per routine clinical practice (standard; STD) and the second (modified; MOD) with treatment fields modified to minimize dose to the arm-draining LNs visible on SPECT/CT images without interfering with the dosage delivered to target tissues. Participants were treated per the MOD plans. Arm volumes were measured prior to radiation and thereafter at least three subsequent 6-month intervals. Results: Sixty-eight level I-III arm-draining LNs were identified, 57% of which were inside the STD plan fields but could be blocked in the MOD plan fields. Sixty-five percent of arm-draining LNs in the STD versus 16% in the MOD plans received a mean of ≥10 Gy, and 26% in the STD versus 4% in the MOD plans received a mean of ≥40 Gy. Mean LN radiation exposure was 23.6 Gy (standard deviation 18.2) with the STD and 7.7 Gy (standard deviation 11.3) with the MOD plans (P<.001). No participant developed lymphedema. Conclusions: The integration of SPECT/CT scans into breast cancer radiation treatment planning reduces unnecessary arm-draining LN radiation exposure and may lessen the risk of lymphedema.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-131: Reproducibility of Positioning Error Due to Temporarily Indwelled Urethral Catheter for Urethra-Sparing Prostate IMRT

Purpose: The purpose of this study was to prospectively assess the reproducibility of positioning errors due to temporarily indwelled catheter in urethra-sparing image-guided (IG) IMRT. Methods: Ten patients received urethra-sparing prostate IG-IMRT with implanted fiducials. After the first CT scan was performed in supine position, 6-Fr catheter was indwelled into urethra, and the second CT images were taken for planning. While the PTV received 80 Gy, 5% dose reduction was applied for the urethral PRV along the catheter. Additional CT scans were also performed at 5th and 30th fraction. Positions of interests (POIs) were set on posterior edge of prostate at beam isocenter level (POI1) and cranial and caudal edge of prostatic urethra on the post-indwelled CT images. POIs were copied into the pre-indwelled, 5th and 30th fraction’s CT images after fiducial matching on these CT images. The deviation of each POI between pre- and post-indwelled CT and the reproducibility of prostate displacement due to catheter were evaluated. Results: The deviation of POI1 caused by the indwelled catheter to the directions of RL/AP/SI (mm) was 0.20±0.27/−0.64±2.43/1.02±2.31, respectively, and the absolute distances (mm) were 3.15±1.41. The deviation tends to be larger if closer to the caudal edge of prostate. Compared with the pre-indwelled CT scan, a median displacement of all POIs (mm) were 0.3±0.2/2.2±1.1/2.0±2.6 in the post-indwelled, 0.4±0.4/3.4±2.1/2.3±2.6 in 5th, and 0.5±0.5/1.7±2.2/1.9±3.1 in 30th fraction’s CT scan with a similar data distribution. There were 6 patients with 5-mm-over displacement in AP and/or CC directions. Conclusion: Reproducibility of positioning errors due to temporarily indwelling catheter was observed. Especially in case of patients with unusually large shifts by indwelling catheter at the planning process, treatment planning should be performed by using the pre-indwelled CT images with transferred contour of the urethra identified by post-indwelled CT images.

60 APPLIED LIFE SCIENCES↗

Single-energy computed tomography-based pulmonary perfusion imaging: Proof-of-principle in a canine model

Purpose: Radiotherapy (RT) that selectively avoids irradiating highly functional lung regions may reduce pulmonary toxicity, which is substantial in lung cancer RT. Single-energy computed tomography (CT) pulmonary perfusion imaging has several advantages (e.g., higher resolution) over other modalities and has great potential for widespread clinical implementation, particularly in RT. The purpose of this study was to establish proof-of-principle for single-energy CT perfusion imaging. Methods: Single-energy CT perfusion imaging is based on the following: (1) acquisition of end-inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast agents, (2) deformable image registration (DIR) for spatial mapping of those two CT image data sets, and (3) subtraction of the precontrast image data set from the postcontrast image data set, yielding a map of regional Hounsfield unit (HU) enhancement, a surrogate for regional perfusion. In a protocol approved by the institutional animal care and use committee, the authors acquired CT scans in the prone position for a total of 14 anesthetized canines (seven canines with normal lungs and seven canines with diseased lungs). The elastix algorithm was used for DIR. The accuracy of DIR was evaluated based on the target registration error (TRE) of 50 anatomic pulmonary landmarks per subject for 10 randomly selected subjects as well as on singularities (i.e., regions where the displacement vector field is not bijective). Prior to perfusion computation, HUs of the precontrast end-inspiratory image were corrected for variation in the lung inflation level between the precontrast and postcontrast end-inspiratory CT scans, using a model built from two additional precontrast CT scans at end-expiration and midinspiration. The authors also assessed spatial heterogeneity and gravitationally directed gradients of regional perfusion for normal lung subjects and diseased lung subjects using a two-sample two-tailed t-test. Results: The mean TRE (and standard deviation) was 0.6 ± 0.7 mm (smaller than the voxel dimension) for DIR between pre contrast and postcontrast end-inspiratory CT image data sets. No singularities were observed in the displacement vector fields. The mean HU enhancement (and standard deviation) was 37.3 ± 10.5 HU for normal lung subjects and 30.7 ± 13.5 HU for diseased lung subjects. Spatial heterogeneity of regional perfusion was found to be higher for diseased lung subjects than for normal lung subjects, i.e., a mean coefficient of variation of 2.06 vs 1.59 (p = 0.07). The average gravitationally directed gradient was strong and significant (R{sup 2} = 0.99, p < 0.01) for normal lung dogs, whereas it was moderate and nonsignificant (R{sup 2} = 0.61, p = 0.12) for diseased lung dogs. Conclusions: This canine study demonstrated the accuracy of DIR with subvoxel TREs on average, higher spatial heterogeneity of regional perfusion for diseased lung subjects than for normal lung subjects, and a strong gravitationally directed gradient for normal lung subjects, providing proof-of-principle for single-energy CT pulmonary perfusion imaging. Further studies such as comparison with other perfusion imaging modalities will be necessary to validate the physiological significance.

60 APPLIED LIFE SCIENCES↗