Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Search for Fluid Inclusions in a Carbonaceous Chondrite Using a New X-Ray Micro-Tomography Technique Combined with FIB Sampling

Early solar system aqueous fluids are preserved in some H chondrites as aqueous fluid inclusions in halite (e.g., [1]). Although potential fluid inclusions are also expected in carbonaceous chondrites [2], they have not been surely confirmed. In order to search for these fluid inclusions, we have developped a new X-ray micro-tomography technique combined with FIB sampling and applied this techniqu to a carbanaceous chondrite. Experimental: A polished thin section of Sutter's Mill meteorite (CM) was observed with an optical microscope and FE-SEM (JEOL 7001F) for chosing mineral grains of carbonates (mainly calcite) and sulfides (FeS and ZnS) 20-50 microns in typical size, which may have aqueous fluid inclusions. Then, a "house" similar to a cube with a roof (20-30 microns in size) is sampled from the mineral grain by using FIB (FEI Quanta 200 3DS). Then, the house was atached to a thin W-needle by FIB and imaged by a SR-based imaging microtomography system with a Fresnel zone plate at beamline BL47XU, SPring-8, Japan. One sample was imaged at two X-ray energies, 7 and 8 keV, to identify mineral phases (dual-enegy microtomography: [3]). The size of voxel (pixel in 3D) was 50-80 nm, which gave the effective spatial resolution of approx. 200 nm. A terrestrial quartz sample with an aqueous fluid inclusion with a bubble was also examined as a test sample by the same method. Results and discussion: A fluid inclusion of 5-8 microns in quartz was clearly identified in a CT image. A bubble of approx. 4 microns was also identified as refraction contrast although the X-ray absorption difference between fluid and bubble is small. Volumes of the fluid and bubble were obtained from the 3D CT images. Fourteen grains of calcite, two grains of iron sulfide and one grain of (Zn,Fe)S were examined. Ten calcite, one iron sulfide and one (Zn,Fe)S grains have inclusions >1 micron in size (the maximum: approx. 5 microns). The shapes are spherical or irregular. Tiny inclusions (<1 micron) are also present in all the grains examined. These results show that mineral grains have more inclusions than expected from 2D observations. The X-ray absorption of the inclusions shows that they are not solid inclusions. No bubbles were observed inside, indicating that we cannot determine whether they are really aqueous fluids or merely voids. One calcite grain has an inclusion approx. 2 microns in size, which seems to have a bubble and a tiny solid daughter crystal inside (three-phase inclusion). As we know the exact 3D position of the inclusion, we will anlyze the inclusion by SIMS after freezing the sample as has been done for a halite sample [3]. The present technique is useful for finding small inclusions not only in carbonaceous chondrites but also for terrestrial materials.

Tsuchiyama, A.↗

Nondestructive Evaluation (NDE) for Inspection of Composite Sandwich Structures

Composite honeycomb structures are widely used in aerospace applications due to their low weight and high strength advantages. Developing nondestructive evaluation (NDE) inspection methods are essential for their safe performance. Flash thermography is a commonly used technique for composite honeycomb structure inspections due to its large area and rapid inspection capability. Flash thermography is shown to be sensitive for detection of face sheet impact damage and face sheet to core disbond. Data processing techniques, using principal component analysis to improve the defect contrast, are discussed. Limitations to the thermal detection of the core are investigated. In addition to flash thermography, X-ray computed tomography is used. The aluminum honeycomb core provides excellent X-ray contrast compared to the composite face sheet. The X-ray CT technique was used to detect impact damage, core crushing, and skin to core disbonds. Additionally, the X-ray CT technique is used to validate the thermography results.

Zalameda, Joseph N.↗

Integration of a Finite Element Model with the DAP Bone Remodeling Model to Characterize Bone Response to Skeletal Loading

NASA's Digital Astronaut Project (DAP) has developed a bone remodeling model that has been validated for predicting volumetric bone mineral density (vBMD) changes of trabecular and cortical bone in the absence of mechanical loading. The model was recently updated to include skeletal loading from exercise and free living activities to maintain healthy bone using a new daily load stimulus (DLS). This new formula was developed based on an extensive review of existing DLS formulas, as discussed in the abstract by Pennline et al. The DLS formula incorporated into the bone remodeling model utilizes strains and stress calculated from finite element model (FEM) of the bone region of interest. The proximal femur was selected for the initial application of the DLS formula, with a specific focus on the femoral neck. METHODS: The FEM was generated from CAD geometry of a femur using de-identified CT data. The femur was meshed using linear tetrahedral elements Figure (1) with higher mesh densities in the femoral neck region, which is the primary region of interest for the initial application of the DLS formula in concert with the DAP bone remodeling model. Nodal loads were applied to the femoral head and the greater trochanter and the base of the femur was held fixed. An L2 norm study was conducted to reduce the length of the femoral shaft without significantly impacting the stresses in the femoral neck. The material properties of the FEM of the proximal femur were separated between cortical and trabecular regions to work with the bone remodeling model. Determining the elements with cortical material properties in the FEM was based off of publicly available CT hip scans [4] that were segmented, cleaned, and overlaid onto the FEM.

Bone Remodeling↗

Complete Tem-Tomography: 3D Structure of Gems Cluster

GEMS (glass with embedded metal and sulfide) grains in interplanetary dust particles (IDPs) are considered to be one of the ubiquitous and fundamental building blocks of solids in the Solar System. They have been considered to be interstellar silicate dust that survived various metamorphism or alteration processes in the protoplanetary disk but the elemental and isotopic composition measurements suggest that most of them have been formed in the protoplanetary disk as condensates from high temperature gas. This formation model is also supported by the formation of GEMS-like grains with respect to the size, mineral assemblage, texture and infrared spectrum by condensation experiments from mean GEMS composition materials. Previous GEMS studies were performed only with 2D observation by transmission electron microscopy (TEM) or scanning TEM (STEM). However, the 3D shape and structure of GEMS grains and the spatial distribution of Fe/FeS's has critical information about their formation and origin. Recently, the 3D structure of GEMS grains in ultrathin sections of cluster IDPs was revealed by electron tomography using a TEM/STEM (JEM-2100F, JEOL). However, CT images of thin sections mounted on Cu grids acquired by conventional TEM-tomography are limited to low tilt angles (e. g., less than absolute value of 75 deg. In fact, previous 3D TEM observations of GEMS were affected by some artifacts related to the limited tilt range in the TEM used. Complete tomographic images should be acquired by rotating the sample tilt angle over a range of more than absolute value of 80 deg otherwise the CT images lose their correct structures. In order to constrain the origin and formation process of GEMS grains more clearly, we performed complete electron tomography for GEMS grains. Here we report the sample preparation method we have developed for this study, and the preliminary results.

Matsuno, J.↗

Management of Asymptomatic Renal Stones in Astronauts

Introduction: Management guidelines were created to screen and manage asymptomatic renal stones in U.S. astronauts. The risks for renal stone formation in astronauts due to bone loss and hypercalcuria are unknown. Astronauts have a stone risk which is about the same as commercial aviation pilots, which is about half that of the general population. However, proper management of this condition is still crucial to mitigate health and mission risks in the spaceflight environment. Methods: An extensive review of the literature and current aeromedical standards for the monitoring and management of renal stones was done. The NASA Flight Medicine Clinic's electronic medical record and Longitudinal Survey of Astronaut Health were also reviewed. Using this work, a screening and management algorithm was created that takes into consideration the unique operational environment of spaceflight. Results: Renal stone screening and management guidelines for astronauts were created based on accepted standards of care, with consideration to the environment of spaceflight. In the proposed algorithm, all astronauts will receive a yearly screening ultrasound for renal calcifications, or mineralized renal material (MRM). Any areas of MRM, 3 millimeters or larger, are considered a positive finding. Three millimeters approaches the detection limit of standard ultrasound, and several studies have shown that any stone that is 3 millimeters or less has an approximately 95 percent chance of spontaneous passage. For mission-assigned astronauts, any positive ultrasound study is followed by low-dose renal computed tomography (CT) scan, and flexible ureteroscopy if CT is positive. Other specific guidelines were also created. Discussion: The term "MRM" is used to account for small areas of calcification that may be outside the renal collecting system, and allows objectivity without otherwise constraining the diagnostic and treatment process for potentially very small calcifications of uncertain significance. However, a small asymptomatic MRM or stone within the renal collecting system may become symptomatic, and so affect launch and flight schedules, cause incapacitation during flight, and ultimately require medical evacuation. For exploration class missions, evacuation is unlikely. The new screening and management algorithm allows better management of mission risks, and will define the true incidence of renal stones in U.S. astronauts. This information will be used to refine future screening, countermeasures and treatment methods; and will also inform the needed capabilities to be flown on exploration-class missions.

Reyes, David↗

Management of Asymptomatic Renal Stones in Astronauts

Introduction: Management guidelines were created to screen and manage asymptomatic renal stones in U.S. astronauts. The risks for renal stone formation in astronauts due to bone loss and hypercalcuria are unknown. Astronauts have a stone risk which is about the same as commercial aviation pilots, which is about half that of the general population. However, proper management of this condition is still crucial to mitigate health and mission risks in the spaceflight environment. Methods: An extensive review of the literature and current aeromedical standards for the monitoring and management of renal stones was done. The NASA Flight Medicine Clinic's electronic medical record and Longitudinal Survey of Astronaut Health were also reviewed. Using this work, a screening and management algorithm was created that takes into consideration the unique operational environment of spaceflight. Results: Renal stone screening and management guidelines for astronauts were created based on accepted standards of care, with consideration to the environment of spaceflight. In the proposed algorithm, all astronauts will receive a yearly screening ultrasound for renal calcifications, or mineralized renal material (MRM). Any areas of MRM, 3 millimeters or larger, are considered a positive finding. Three millimeters approaches the detection limit of standard ultrasound, and several studies have shown that any stone that is 3 millimeters or less has an approximately 95 percent chance of spontaneous passage. For mission-assigned astronauts, any positive ultrasound study is followed by low-dose renal computed tomography (CT) scan, and flexible ureteroscopy if CT is positive. Other specific guidelines were also created. Discussion: The term "MRM" is used to account for small areas of calcification that may be outside the renal collecting system, and allows objectivity without otherwise constraining the diagnostic and treatment process for potentially very small calcifications of uncertain significance. However, a small asymptomatic MRM or stone within the renal collecting system may become symptomatic, and so affect launch and flight schedules, cause incapacitation during flight, and ultimately require medical evacuation. For exploration class missions, evacuation is unlikely. The new screening and management algorithm allows better management of mission risks, and will define the true incidence of renal stones in U.S. astronauts. This information will be used to refine future screening, countermeasures and treatment methods; and will also inform the needed capabilities to be flown on exploration-class missions.

Reyes, David↗

Measured Boundary Layer Transition and Rotor Hover Performance at Model Scale

An experiment involving a Mach-scaled, 11:08 f t: diameter rotor was performed in hover during the summer of 2016 at NASA Langley Research Center. The experiment investigated the hover performance as a function of the laminar to turbulent transition state of the boundary layer, including both natural and fixed transition cases. The boundary layer transition locations were measured on both the upper and lower aerodynamic surfaces simultaneously. The measurements were enabled by recent advances in infrared sensor sensitivity and stability. The infrared thermography measurement technique was enhanced by a paintable blade surface heater, as well as a new high-sensitivity long wave infrared camera. The measured transition locations showed extensive amounts, x=c>0:90, of laminar flow on the lower surface at moderate to high thrust (CT=s > 0:068) for the full blade radius. The upper surface showed large amounts, x=c > 0:50, of laminar flow at the blade tip for low thrust (CT=s < 0:045). The objective of this paper is to provide an experimental data set for comparisons to newly developed and implemented rotor boundary layer transition models in CFD and rotor design tools. The data is expected to be used as part of the AIAA Rotorcraft SimulationWorking Group

Overmeyer, Austin D.↗

A PCR Based Microbial Monitoring Alternative Method of Detection and Identification of Microbes Aboard ISS

Previous research has shown that microorganisms and potential human pathogens have been detected on the International Space Station (ISS) with additional introduction of new microflora occurring with every exchange of crew or addition of equipment and supplies. These microbes are readily transferred between crew and subsystems (i.e. ECLSS, environmental control and life support systems). As this can be detrimental to astronaut health and optimal performance of ISS systems, monitoring of systems such as ECLSS to include identification of microbial contaminants could prevent adverse effects on human health and life support systems. Current monitoring on ISS is laborious and utilizes culture based methods followed by sample return to Earth for complete analysis. Future, long-distance spaceflight missions will require real-time monitoring capabilities that enable efficient and rapid assessments of the microbial environment allowing for expedited decisions and more targeted response to cope with anomalies. Polymerase chain reaction (PCR), a molecular microbial monitoring method was chosen and numerous PCR instruments investigated for their potential to perform in microgravity conditions. Using ISS as a test bed for PCR verification in microgravity will enable NASA to assess whether molecular based microbiological sensors may be components of reliable, closed-loop life support and habitation systems in spacecraft, enhancing infrastructure capabilities through increased efficiency, reliability, and time savings by enabling sample analysis on orbit. NASA selected the Water Monitoring Suite as one of the rapid spaceflight hardware demonstration activities utilizing a streamlined process to minimize the time required to fly experimental flight hardware. The RAZOR EX (BioFire Defense, Salt Lake City, UT) system was part of the water monitoring suite and is a commercial off-the-shelf (COTS) real-time PCR instrument designed for field work. The RAZOR EX was originally designed for Department of Defense (DoD) under a small business innovative research (SBIR) grant and is ruggedized, compact and provides a rapid, sample to answer in less than an hour. PCR assays using a fluorescent probe were optimized and spiked with known concentrations of DNA (Pseudomonas aeruginosa) ranging from 0.002 to 20 ng. PCR reagents were lyophilized and configured in customized pouches and tested for flight readiness. Three types of water were used to rehydrate the reagents and demonstrate the fidelity of the PCR reaction in microgravity. Molecular grade deionized water served as a control while filtered and unfiltered ISS potable water served to test for chemical or biological inhibitors. All three types were compared to parallel ground test results. Nine tests were run on ISS (3 of each water type) and the critical threshold cycle (Ct) was compared to parallel ground tests completed at Kennedy Space Center, FL and Johnson Space Center, TX. All concentrations of Pseudomonas aeruginosa DNA were detected. A comparison of the Ct produced in real time PCR indicated similarity between flight and ground samples. There appeared to be no significant difference between flight or ground PCR reactions or between any of the three water types. This testing demonstrated the ability to perform molecular testing during spaceflight operations with similar sensitivity. It will allow for future ground development of molecular protocols and minimize the need for spaceflight testing. Future testing will include development of additional targets including environmental and health related organisms.

Christina Khodadad↗

A New Compton-Thick AGN in Our Cosmic Backyard: Unveiling the Buried Nucleus in NGC 1448 with NuSTAR

NGC 1448 is one of the nearest luminous galaxies [L(sub 8) - 1000 micrometers is greater than 10(exp. 9) Solar Luminosity] to ours (z = 0.00390), and yet the active galactic nucleus (AGN) it hosts was only recently discovered, in 2009. In this paper, we present an analysis of the nuclear source across three wavebands: mid-infrared (MIR) continuum, optical, and X-rays. We observed the source with the Nuclear Spectroscopic Telescope Array (NuSTAR), and combined these data with archival Chandra data to perform broadband X-ray spectral fitting ( approx. equals 0.5 - 40 keV) of the AGN for the first time. Our X-ray spectral analysis reveals that the AGN is buried under a Compton-thick (CT) column of obscuring gas along our line of sight, with a column density of N(sub H)(los) approx. greater than 2.5 x 10(exp. 24) cm(exp. -2). The best-fitting torus models measured an intrinsic 2-10 keV luminosity of L(sub 2)-10,int = (3.5 - 7.6) x 10(exp. 40) erg s(exp. -1), making NGC 1448 one of the lowest luminosity CTAGNs known. In addition to the NuSTAR observation, we also performed optical spectroscopy for the nucleus in this edge-on galaxy using the European Southern Observatory New Technology Telescope. We reclassify the optical nuclear spectrum as a Seyfert on the basis of the Baldwin- Philips-Terlevich diagnostic diagrams, thus identifying the AGN at optical wavelengths for the first time. We also present high spatial resolution MIR observations of NGC 1448 with Gemini/T-ReCS, in which a compact nucleus is clearly detected. The absorption-corrected 2-10 keV luminosity measured from our X-ray spectral analysis agrees with that predicted from the optical [O III] Lamda 5007 A emission line and the MIR 12 micrometer continuum, further supporting the CT nature ofthe AGN.

galaxies: active – galaxies: nuclei – techniqu↗

Successful Validation of RNA Purification and Quantitative Real-Time PCR Analysis of Gene Expression on the International Space Station

The NASA Ames WetLab-2 system was developed to offer new on-orbit gene expression analysis capabilities to ISS researchers and can be used to conduct on-orbit RNA isolation and quantitative real time PCR (RT-qPCR) analysis of gene expression from a wide range of biological samples ranging from microbes to mammalian tissues. On orbit validation included three quantitative PCR (qPCR) runs using an E. coli genomic DNA template pre-loaded at three different concentrations. The flight Ct values for the DNA standards showed no statistically significant differences relative to ground controls although there was increased noise in Ct curves, likely due to microgravity-related bubble retention in the optical windows. RNA was successfully purified from both E. coli and mouse liver samples and successfully generated singleplex, duplex and triplex data although with higher standard deviations than ground controls, also likely due to bubbles. Using volunteer science activities, a potential bubble reduction strategy was tested and resulted in smooth amplification curves and tighter Cts between replicates. The WetLab-2 validation experiment demonstrates a novel molecular biology workbench on ISS which allows scientists to purify and stabilize RNA, and to conduct RT-qPCR analyses on-orbit with rapid results. This novel ability is an important step towards utilizing ISS as a National Laboratory facility with the capability to conduct and adjust science experiments in real time without sample return, and opens new possibilities for rapid medical diagnostics and biological environmental monitoring on ISS.

microgravity↗

Effect of Ex Vivo Ionizing Radiation on Static and Fatigue Properties of Mouse Vertebral Bodies

For a variety of medical and scientific reasons, human bones can be exposed to a wide range of ionizing radiation levels. In vivo radiation therapy (0.05 kGy) is used in cancer treatment, and ex vivo irradiation (25-35 kGy) is used to sterilize bone allografts. Ionizing radiation in these applications has been shown to increase risk of fracture, decrease bone quality and degrade collagen integrity. Past studies have investigated the deleterious effects of radiation on cortical or trabecular bone specimens individually, but to date no studies have examined whole bones containing both cortical and trabecular tissue. Furthermore, a clear relationship between the dose and the mechanical and biochemical response of bone's extracellular matrix has yet to be established for doses ranging from cancer therapy to allograft sterilization (0.05-35 kGy). To gain insight into these issues, we conducted an ex vivo radiation study to investigate non-cellular (i.e. matrix) effects of ionizing radiation dose on vertebral whole bone mechanical properties, over a range of radiation doses (0.05-35 kGy), with a focus on any radiation-induced changes in collagen. With underlying mechanisms of action in mind, we hypothesized that any induced reductions in mechanical properties would be associated with changes in collagen integrity. METHODS: 20-week old female mice were euthanized and the lumbar spine was dissected using IACUC approved protocols. The lumbar vertebrae (L1- S1) were extracted from the spine via cuts through adjacent intervertebral discs, and the endplates, posterior processes, surrounding musculature, and soft tissues were removed (approx. 1.5mm diameter, approx. 2mm height). Specimens were randomly assigned to one of five groups for ex vivo radiation exposure: x-ray irradiation at 0.05, 1, 17, or 35 kGy, or a 0 kGy control. Following irradiation, the vertebrae were imaged using microcomputed tomography (micro-CT) and then subjected to either monotonic compressive loading to failure or uniform cyclic compressive loading. During cyclic testing, samples were loaded in force control to a force level that corresponded to a strain of 0.46%, as determined in advance by a linearly elastic micro-CT-based finite element analysis for each specimen. Tests were stopped at imminent fracture, defined as a rapid increase in strain. The main outcome for the monotonic test was the strength (maximum force); for cyclic testing it was the fatigue life (log of the number of cycles of loading at imminent failure). A fluorometric assay was used on the S1 vertebrae to measure the number of non-enzymatic collagen crosslinks[4]. A one-way ANOVA was performed on mechanical properties and collagen crosslinks; means were compared with controls using Dunnett's method, with a Tukey-Kramer post-hoc analysis when significance was found (p < or = 0.05). RESULTS: Compared to the unirradiated control group, the concentration of non-enzymatic collagen crosslinks was significantly increased for all irradiated groups (p < 0.0001), and being higher by at least 50% (Figure 1a). By contrast, the radiation effects on the collagen were only evident at the higher doses. For irradiation exposures of 17 kGy or more, strength decreased substantially as the radiation level was increased, but no effect was evident below 17 kGy (Figure 1b). There was no significant change in the stiffness or maximum displacement for any radiation dose (p>0.05). The finite element analysis prescribed force level for cyclic loading exceeded the measured (monotonic) strength of the 17 and 35 kGy irradiated groups (mean +/- SD, 20.6 +/- 5.6 N; 13.2 +/- 3.7 N, respectively) and therefore these groups were eliminated from the fatigue study. The fatigue life for the 0.05 and 1 kGy groups were similar to each other and were not statistically significantly different from the control group (Figure 1c).

radiation↗

Theory Validation - 2 Points of View

The task of validating any given theory against any given proprotor/propeller data set is of immense importance. Not just to the researchers who are developing a theory, but to the working engineers using the theory to design a proprotor/propeller. However, there is major difference in how the two groups see validation. This difference is that, most frequently, researchers see the validation in coefficient form as, for example, CP versus CT or Figure of Merit versus CT. In contrast, design engineers are always working in the dimensional world as, for example, horsepower required to hover versus aircraft weight. The objective of the design engineer is, of course, to release drawings and specifications to manufacturing so a VTOL aircraft will be built with reasonably high assurance that the aircraft will meet the primary specifications.

Harris, Franklin D.↗

Biaxial Braided Flared Cone Structural Analysis

Computed Tomography (CT) is a useful tool for performing structural analysis on polymer based materials due to its high precision and accuracy. CT data was taken of two flared cones made from carbon fiber and fiberglass. One of the flared cones is pictured below. The variation in braid angle throughout the part was measured using Avizo 3D modelling software while the variation in thickness throughout the part was determined using MATLAB. Samples of pictures from the process of each of these analyses are shown below. The overall goal of this analysis was to collect structural data relevant to future testing of the parts.

Computed Tomography↗

Acquisition and Processing of Passive Thermography Fatigue Test Data

Passive thermography is a large area inspection technique and is commonly used during fatigue loading of composite structures. Passive thermography allows for real time tracking of damage. This provides an accurate assessment of the damage progression as a function of load cycles and determines when the loading is stopped for ultrasonic or X-ray CT evaluations for detail damage assessment through-the-thickness. In addition, if new areas of damage growth are detected, with passive thermography, then those areas are additionally inspected with ultrasound or X-ray CT. A custom developed passive thermography inspection system for fatigue loading is presented. Passive thermography of damage progression is compared to ultrasound inspections as a function of the fatigue cycles. Discussion is made on processing of the thermal data for periodic and non-periodic thermal responses.

Thermal nondestructive evaluation↗

Characterizing Effects of Potential Build Induced Artifacts in L-PBF Components

Additive manufacture (AM) is utilized for rocket engine component production. Witness marks are visible lines across the surface of an AM part that result from variation in build process. Witness marks have been used as justification to scrap a part with little to no evidence. The probability of witness mark occurrence is relatively high and greatly increases AM part production costs and schedule risks. The objective of this study was to quantify the impact of witness marks generated by intentional build pauses and characterize functional characteristics of the AM components. CT, μ-CT, metallographic, and mechanical test results indicate that witness marks are a surface phenomenon that do not propagate into the bulk of a part and had no statistically significant change on microstructure or properties in AlSi10Mg.

Omar R Mireles↗

Predictive Modeling of Carbon Ablators

Efforts to build a Predictive Material Modeling (PMM) framework from the micro-scale to the macro-scale are presented in this abstract. To reduce the need for extensive testing, accelerate the design cycle process, and reduce uncertainty margins applied to final designs, NASA is developing simulation and modeling tools that enable characterization of material properties and response to high-enthalpy environments. The Porous Microstructure Analysis (PuMA) code has been developed for computing macroscale (volume averaged) properties of porous materials using microscale images from micro-computed tomography (micro-CT). Microscale modeling requires a realistic representation of a material microstructure; these are obtained either synthetically during the design of the material or through X-ray micro-CT. Volume averaged properties are then used to inform macroscale material response models, such as those implemented in the Porous-material Analysis Toolbox based on OpenFOAM (PATO) software, also actively developed by NASA. The computational model in PATO is a generic heat and mass transfer model for porous reactive materials containing several solid phases and a single gas phase. The detailed chemical interactions occurring between the solid phases and the gas phase are modeled at the pore scale assuming local thermal equilibrium. These tools were developed to efficiently interface with other pre-existing codes such as SPARTA (direct simulation Monte Carlo), DPLR (hypersonic CFD), NEQAIR (radiative transport) and DAKOTA (uncertainty quantification and optimization). Detailed flight data (Mars Science Laboratory [MSL] Entry Descent and Landing Instrument [MEDLI]) is critical for validating these computational tools for NASA applications. Examples of modeling ablative material response using these codes will be presented including 3D simulations of the full-scale heatshield of the MSL capsule. The simulations demonstrate the ability of the modern material response code, PATO, to handle the material response of geometrically complex and large domains, through the use of massively parallel computations.

Thermal Protection Systems↗

High Resolution Computed Tomography Inspection of Components Uncovers Root Causes of Vexing Failure Mysteries

During testing of actuators for fight programs, failures have occurred that required closure with an understanding of the root cause of the failure. For some InSight project actuators, intermittent changes of the winding resistance of the motors during temperature changes was extremely baffling. It was critical to determine the cause of the intermittent characteristic because the actuators were stock from a previous program and the company that provided the motors was no longer in business. Using an X-Ray Computed-Tomography (CT) method, the exact source of the intermittent failure was determined and completely understood – at dimensions of less than 20 microns. In another case, after the completion of an actuator’s life-test-to-failure, inspection was required to determine the source of the failure. The size of the actuator (10 mm diameter) required destructive means to get to the interior of the actuator for inspection, risking the loss of the source of the failure. Using CT imaging, the exact source of the failure was determined.

Johnson, Michael R.↗

Predictive Modeling of Carbon Ablators Using Micro and Macro-Scale Modeling

Efforts to build a Predictive Material Modeling (PMM) framework from the micro-scale to the macro-scale are presented in this abstract. To reduce the need for extensive testing, accelerate the design cycle process, and reduce uncertainty margins applied to final designs, NASA is developing simulation and modeling tools that enable characterization of material properties and response to high-enthalpy environments. The Porous Microstructure Analysis (PuMA) code has been developed for computing macroscale (volume averaged) properties of porous materials using microscale images from micro-computed tomography (micro-CT). Microscale modeling requires a realistic representation of a material microstructure; these are obtained either synthetically during the design of the material or through X-ray micro-CT. Volume averaged properties are then used to inform macroscale material response models, such as those implemented in the Porous-material Analysis Toolbox based on OpenFOAM (PATO) software, also actively developed by NASA. The computational model in PATO is a generic heat and mass transfer model for porous reactive materials containing several solid phases and a single gas phase. The detailed chemical interactions occurring between the solid phases and the gas phase are modeled at the pore scale assuming local thermal equilibrium. These tools were developed to efficiently interface with other pre-existing codes such as SPARTA (direct simulation Monte Carlo), DPLR (hypersonic CFD), NEQAIR (radiative transport) and DAKOTA (uncertainty quantification and optimization). Detailed flight data (Mars Science Laboratory [MSL] Entry Descent and Landing Instrument [MEDLI]) is critical for validating these computational tools for NASA applications. Examples of modeling ablative material response using these codes will be presented including 3D simulations of the full-scale heatshield of the MSL capsule. The simulations demonstrate the ability of the modern material response code, PATO, to handle the material response of geometrically complex and large domains, through the use of massively parallel computations.

Thermal Protection Systems↗