Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Simurgh: A Framework for Cad-Driven Deep Learning Based X-Ray CT Reconstruction

High-resolution X-ray computed tomography (XCT) is an important technique for the inspection of additively manufactured (AM) parts. While XCT is typically used off-line to inspect a subset of manufactured parts, significantly accelerating measurement speed while retaining accuracy would enable use of XCT for in-line inspection to rapidly identify defects in each part as it is manufactured. Here, we propose a deep learning (DL) based approach that uses computer aided design (CAD) models of the AM parts and physics-based information to rapidly produce high-quality reconstructions from sparse XCT measurements without high quality ground truth data. Our approach uses a generative adversarial neural network (GAN) to produced realistic training data from the CAD-based simulations and a deep neural network that is trained using data from the first stage to produce accurate 3D reconstructions. Using experimental XCT data of metal parts, we demonstrate enhanced defect detection capabilities while dramatically reducing the scan time.

Ziabari, Amir↗

Ultrasonic Testing (UT) and Computed Tomography (CT) Comparative Scanning of Proposed Additive Manufacturing Reference Standard

This report presents qualitative results of ultrasonic full matrix capture/total focusing method (FMC/TFM) scanning of two series of blocks, additively manufactured by powder bed fusion, containing a variety of internal features and structures that would not be achievable by conventional manufacturing techniques. The purpose of the first series of additively manufactured (AM) blocks was to explore the possibility of building calibration blocks for FMC/TFM ultrasonic testing (UT). It was confirmed that AM is a suitable candidate for generation of unusual and novel reflector forms, such as rotating slots, purposely embedded voids, and tapering holes, and that FMC/TFM was very capable of characterizing them. The intended use of the second series of AM blocks was as UT reference blocks to characterize the AM process quality or the interrogating UT technique. The larger block in this series was scanned from multiple faces, using multiple UT methods (conventional UT and FMC/TFM) and X-ray computed tomography for comparative purposes. The performance of each method was quantified by a metric corresponding to the detection limit of each feature, and the quantitative results are discussed.

36 MATERIALS SCIENCE↗

The effects of 8-week complex training on lower-limb strength and power of Chinese elite female modern pentathlon athletes

Complex training (CT) is a combination training method that alternates between performing high-load resistance training (RT) and plyometric training within one single session. The study aimed to examine the effects of CT on lower-limb strength and power of elite female modern pentathlon athletes under the new modern pentathlon format and competition rules. Ten female participants (age: 23.55 ± 2.22 years, weight: 60.59 ± 3.87 kg, height: 169.44 ± 4.57 cm, and training experience: 6.90 ± 2.08 years) of the national modern pentathlon team completed 8 weeks of RT as followed by 8 weeks of CT, with 2 weeks of break. Then, the participants conducted 8 weeks of CT, which included RT combined with plyometric training (e.g., drop jump and continuous jump). All stages of training were designed by the linear strength training period theories, requiring participants to train twice for the first 4 weeks and three times for the second 4 weeks. The one-repetition maximum (1RM) of squat, isometric mid-thigh pull (IMTP), counter-movement jump (CMJ), squat jump (SJ), pre-stretch augmentation percentage (PSAP), and reaction strength index (RSI) were assessed before and after both RT and CT training. One-way repeated-measure ANOVA models revealed that the 1RM of squat was significantly improved ( p < 0.001) after RT as compared to pre-RT. No significant improvement in IMTP ( p = 0.055), CMJ ( p = 0.194), SJ ( p = 0.692), PSAP ( p = 0.087), and RSI ( p = 0.238) was not observed. After CT, 1RM of squat ( p < 0.001), IMTP ( p < 0.035), CMJ ( p < 0.001), SJ ( p < 0.008), RSI ( p < 0.006) were significant improved as compared to pre-RT, post-RT and pre-CT, while significant improvements in PSAP were observed as compared to pre-RT ( p = 0.003) and pre-CT ( p = 0.027), but not to post-RT ( p = 0.156). This pilot study showed the promise of CT following RT to improve lower-limb strength and power in elite female modern pentathlon athletes. The findings are worthwhile to be confirmed in future studies with larger sample size and randomized design.

Qiao, Zining↗

Time-Domain Terahertz Computed Axial Tomography NDE System

NASA has identified the need for advanced non-destructive evaluation (NDE) methods to characterize aging and durability in aircraft materials to improve the safety of the nation's airline fleet. 3D THz tomography can play a major role in detection and characterization of flaws and degradation in aircraft materials, including Kevlar-based composites and Kevlar and Zylon fabric covers for soft-shell fan containment where aging and durability issues are critical. A prototype computed tomography (CT) time-domain (TD) THz imaging system has been used to generate 3D images of several test objects including a TUFI tile (a thermal protection system tile used on the Space Shuttle and possibly the Orion or similar capsules). This TUFI tile had simulated impact damage that was located and the depth of damage determined. The CT motion control gan try was designed and constructed, and then integrated with a T-Ray 4000 control unit and motion controller to create a complete CT TD-THz imaging system prototype. A data collection software script was developed that takes multiple z-axis slices in sequence and saves the data for batch processing. The data collection software was integrated with the ability to batch process the slice data with the CT TD-THz image reconstruction software. The time required to take a single CT slice was decreased from six minutes to approximately one minute by replacing the 320 ps, 100-Hz waveform acquisition system with an 80 ps, 1,000-Hz waveform acquisition system. The TD-THZ computed tomography system was built from pre-existing commercial off-the-shelf subsystems. A CT motion control gantry was constructed from COTS components that can handle larger samples. The motion control gantry allows inspection of sample sizes of up to approximately one cubic foot (.0.03 cubic meters). The system reduced to practice a CT-TDTHz system incorporating a COTS 80- ps/l-kHz waveform scanner. The incorporation of this scanner in the system allows acquisition of 3D slice data with better signal-to-noise using a COTS scanner rather than the gchirped h scanner. The system also reduced to practice a prototype for commercial CT systems for insulating materials where safety concerns cannot accommodate x-ray. A software script was written to automate the COTS software to collect and process TD-THz CT data.

Zimdars, David↗

Bridging Nano- and Microscale X-Ray Tomography for Battery Research by Leveraging Artificial Intelligence

X-ray computed tomography (CT) is a non-destructive imaging technique in which contrast originates from the materials' absorption coefficient. The recent development of laboratory nanoscale CT (nano-CT) systems has pushed the spatial resolution for battery material imaging to voxel sizes of 50 nm, a limit previously achievable only with synchrotron facilities. Given the non-destructive nature of CT, in situ and operando studies have emerged as powerful methods to quantify morphological parameters, such as tortuosity factor, porosity, surface area and volume expansion, during battery operation or cycling. Combined with artificial intelligence and machine learning analysis techniques, nano-CT has enabled the development of predictive models to analyse the impact of the electrode microstructure on cell performances or the influence of material heterogeneities on electrochemical responses. In this Review, we discuss the role of X-ray CT and nano-CT experimentation in the battery field, discuss the incorporation of artificial intelligence and machine learning analyses and provide a perspective on how the combination of multiscale CT imaging techniques can expand the development of predictive multiscale battery behavioural models.

diagnostics↗

Expression and structure of the Chlamydia trachomatis DksA ortholog

Chlamydia trachomatis is a bacterial obligate intracellular parasite and a significant cause of human disease, including sexually transmitted infections and trachoma. The bacterial RNA polymerase-binding protein DksA is a transcription factor integral to the multicomponent bacterial stress response pathway known as the stringent response. The genome of C. trachomatis encodes a DksA ortholog (DksA Ct ) that is maximally expressed at 15–20 h post infection, a time frame correlating with the onset of transition between the replicative reticulate body (RB) and infectious elementary body (EB) forms of the pathogen. Ectopic overexpression of DksA Ct in C. trachomatis prior to RB–EB transitions during infection of HeLa cells resulted in a 39.3% reduction in overall replication (yield) and a 49.6% reduction in recovered EBs. While the overall domain organization of DksA Ct is similar to the DksA ortholog of Escherichia coli (DksA Ec ), DksA Ct did not functionally complement DksA Ec . Transcription of dksA Ct is regulated by tandem promoters, one of which also controls expression of nrdR, encoding a negative regulator of deoxyribonucleotide biosynthesis. The phenotype resulting from ectopic expression of DksA Ct and the correlation between dksA Ct and nrdR expression is consistent with a role for DksA Ct in the C. trachomatis developmental cycle.

59 BASIC BIOLOGICAL SCIENCES↗

Elongation Factor Tu Acts as a Chaperone to Activate an Antibacterial RNase Toxin

Many Gram-negative bacterial species use contact-dependent growth inhibition (CDI) systems to deliver toxic proteins into neighboring competitors. CDI + strains deploy CdiA effector proteins, which translocate their C-terminal toxin (CT) domains into target bacteria through a receptor-mediated delivery pathway. To protect against auto-intoxication, CDI + bacteria also produce CdiI immunity proteins that neutralize CT toxin activity. Here, we present the crystal structure of the CT·CdiI O32:H37 complex from Escherichia coli O32:H37. CT O32:H37 adopts the same fold as the tRNase domain of colicin D, and the nucleases share similar catalytic centers. However, unlike colicin D, which cleaves the anticodon loops of tRNA Arg isoacceptors, CT O32:H37 exhibits nonspecific RNase activity. Notably, we find that endogenous elongation factor Tu (EF-Tu) co-purifies with the over-produced CT·CdiI O32:H37 complex. Although EF-Tu does not bind stably to CT O32:H37 in the absence of CdiI O32:H37 , the translation factor is required for toxic RNase activity in vitro. AlphaFold 3 modeling and site-directed mutagenesis indicate that CT O32:H37 interacts with the N-terminal GTPase domain of EF-Tu. EF-Tu appears to stabilize residue Trp52 within the hydrophobic core of the toxin, which in turn supports the RNase active site through an unusual hydrogen-bonding interaction with the catalytic His67 residue. Furthermore, EF-Tu is hijacked as an essential co-factor to organize the toxin's catalytic center.

Nhan, Dinh Quan [University of California, Santa B↗

Identifying the Accuracy of Surface Roughness for Metal Additive Manufacturing Parts Captured with Computed Tomography Scanning

Conventional surface roughness measurement techniques require direct access to internal surfaces, often necessitating destructive sectioning of test articles. Computed tomography (CT) offers a non-destructive alternative for internal surface characterization, but its application in metrology remains unstandardized and sensitive to machine resolution and operator technique. This study investigates the feasibility of using CT scanning to quantify areal surface roughness in metal AM heat exchanger tubes with three distinct internal geometries: ribbed, discrete W, and featureless. CT-derived surface parameters were extracted using custom Python scripts and compared to measurements obtained from a focus variation microscope calibrated against a known standard. Results show that CT-based roughness measurements closely matched microscope values for the discrete W specimen, deviations between CT and microscope measurements were minimal—less than 1 µm—indicating reliable reconstruction. In contrast, the ribbed and featureless specimens, with lower roughness values showed greater discrepancies. The findings suggest that CT scanning can be a viable non-destructive metrology tool for AM parts with surface roughness above approximately 8 µm. For smoother surfaces, current CT capabilities may not provide sufficient accuracy, highlighting the need for resolution-aware workflows and further standardization in CT-based surface metrology.

36 MATERIALS SCIENCE↗

Cooperative Effects of Corticosteroids and Catecholamines upon Immune Deviation of the Type-1/Type-2 Cytokine Balance in Favor of Type-2 Expression in Human Peripheral Blood Mononuclear Cells

A growing number of studies show strong associations between stress and altered immune function. In vivo studies of chronic and acute stress have demonstrated that cognitive stressors are strongly correlated with high levels of catecholamines (CT) and corticosteroids (CS). Although both CS and CT individually can inhibit the production of T-helper 1 (TH1, type-1 like) cytokines and simultaneously promote the production of T-helper 2 (TH2, type-2 like) cytokines in antigen-specific and mitogen stimulated human leukocyte cultures in vitro, little attention has been focused on the effects of combination CT and CS in immune responses that may be more physiologically relevant. We therefore investigated the combined effects of in vitro CT and CS upon the type-1/type-2 cytokine balance of human peripheral blood mononuclear cells (PBMC) as a model to study the immunomodulatory effects of superimposed acute and chronic stress. Results demonstrated a significant decrease in type-1 cytokine production (IFN-gamma) and a significant increase in type-2 cytokine production (IL-4, IL-10) in our CS+CT incubated cultures when compared to either CT or CS agents alone. Furthermore, variable enhancement of type-1/type-2 immune deviation occurred depending upon when the CT was added. The data suggest that CS can increase the sensitivity of PBMC to the immunomodulatory effects of CT and establishes an in vitro model to study the combined effects of in vivo type-1/type-2 cytokine alterations observed in acute and chronic stress.

Salicru, A. N.↗

Generalizing Reversible Triplet–Triplet Energy Transfer as a Strategy to Increase Excited-State Lifetime in Copper(I) Charge-Transfer Chromophores

In this work, we generalize reversible triplet–triplet energy transfer (TTET) as a strategy to achieve long (μs range) excited-state lifetimes in copper(I) photosensitizers of the general formula Cu(RNacNac)(CN-Ar) (RNacNac is a substituted β-diketiminate and CN-Ar is an aryl isocyanide). Six new complexes are presented where the isocyanide is substituted with a triplet–acceptor moiety─anthracene, naphthalene, or phenanthrene. In-depth photophysical analysis reveals that energetic matching of the charge-transfer ( 3 CT) and acceptor-localized 3 (π→π*) states is key to achieving long triplet excited-state lifetimes via reversible TTET. With 2-isocyanoanthracene as the acceptor ligand, 3 CT and 3(π→π*) are not energetically proximate, and irreversible quenching of 3 CT occurs. With a small 0.1–0.2 eV gap between the two triplet states, luminescence originates from the 3 CT state with a moderate excited-state lifetime of 250 or 283 ns observed. As key to the success of this approach, we demonstrate that altering the N-substituent on the RNacNac ligand modulates the energy of the 3 CT state, giving three complexes where the 3 CT and 3 (π→π*) energies are perfectly matched and the excited-state lifetimes are much longer, spanning 1.9–2.7 μs. As such, the key lesson of this work is that long triplet-state lifetimes in these compounds can be achieved by proper “mixing and matching” of the RNacNac ligand, which influences the 3 CT energy, and the triplet acceptor group which dictates the energy of the 3 (π→π*) state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗