Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COUNTING RATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Fresh Fuel Measurements With the Differential Die-Away Self-Interrogation Instrument

The purpose of the Next Generation Safeguards Initiative (NGSI)-Spent Fuel (SF) Project is to strengthen the technical toolkit of safeguards inspectors and/or other interested parties. Thus the NGSI-SF team is working to achieve the following technical goals more easily and efficiently than in the past using nondestructive assay measurements of spent fuel assemblies: 1) verify the initial enrichment, burnup, and cooling time of facility declaration; 2) detect the diversion or replacement of pins; 3) estimate the plutonium mass; 4) estimate decay heat; and 5) determine the reactivity of spent fuel assemblies. The differential die-away self-interrogation (DDSI) instrument is one instrument that was assessed for years regarding its feasibility for robust, timely verification of spent fuel assemblies. The instrument was recently built and was tested using fresh fuel assemblies in a variety of configurations, including varying enrichment, neutron absorber content, and symmetry. The early die-away method, a multiplication determination method developed in simulation space, was successfully tested on the fresh fuel assembly data and determined multiplication with a root-mean-square (RMS) error of 2.9%. The experimental results were compared with MCNP simulations of the instrument as well. Low multiplication assemblies had agreement with an average RMS error of 0.2% in the singles count rate (i.e., total neutrons detected per second) and 3.4% in the doubles count rates (i.e., neutrons detected in coincidence per second). High-multiplication assemblies had agreement with an average RMS error of 4.1% in the singles and 13.3% in the doubles count rates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A three-coordinate system (ecliptic, galactic, ISMF) spectral analysis of heliospheric ENA emissions using CASSINI/INCA measurements

In the present study, we use all-sky energy-resolved energetic neutral atom (ENA) maps obtained by the Ion and Neutral CAmera (INCA) instrument on board Cassini that correspond to the time period from 2003 to 2009, in four discrete energy passbands (∼5.4 to ∼55 keV), to investigate the geometrical characteristics of the belt (a broad band of emission in the sky). The heliospheric ENA emissions are mapped in three different coordinate systems (ecliptic, Galactic, and interstellar magnetic field (ISMF)), and spectral analyses are performed to further examine the belt's possible energy dependence. Our conclusions are summarized as follows: (1) the high flux ENA belt identified in the energy range of 8-42 keV is moderately well organized in Galactic coordinates, as the ENA minima appear in the vicinity of the north and south Galactic poles; (2) using minimization criteria ( B · R ∼ 0), the deviation of the ENA emissions from the equator is effectively minimized in a rotated frame, which we interpret as ISMF, where its north pole points toward 190° ecliptic longitude and 15° ecliptic latitude; (3) ENA spectra show a power-law form in energy that can be fitted with a single function presenting higher spectral slopes in the belt region and lower outside (3.4 < γ < 4.4); (4) the spectra are almost indistinguishable between the tail and the nose regions, i.e., no noticeable asymmetry is observed; (5) the consistency of the ENA distributions as a function of latitude among the different INCA channels indicates that the morphology of the belt (peak, width, and structure) is nearly energy independent from 8 keV to 30 keV (minor deviations start to appear at >35 keV); and (6) in the low count rate regions, the long-term ENA count rate profiles do not match the measured cosmic ray profiles, indicating that even the minimum ENA emissions detected by INCA are foreground ENAs.

79 ASTRONOMY AND ASTROPHYSICS↗

The normalization of solar X-ray data from many experiments.

A conversion factor is used to convert Geiger (GM) tube count rates or ion chamber currents into units of the incident X-ray energy flux in a specified passband. A method is described which varies the passband to optimize these conversion factors such that they are relatively independent of the spectrum of the incident photons. This method was applied to GM tubes flown on Explorers 33 and 35 and Mariner 5 and to ion chambers flown on OSO 3 and OGO 4. Revised conversion factors and passbands are presented, and the resulting absolute solar X-ray fluxes based on these are shown to improve the agreement between the various experiments. Calculations have shown that, although the GM tubes on Explorer 33 viewed the Sun off-axis, the effective passband did not change appreciably, and the simple normalization of the count rates to the count rates of a similar GM tube on Explorer 35 was justified.

Wende, C. D.↗

Photon Counting Detectors for the 1.0 - 2.0 Micron Wavelength Range

We describe results on the development of greater than 200 micron diameter, single-element photon-counting detectors for the 1-2 micron wavelength range. The technical goals include quantum efficiency in the range 10-70%; detector diameter greater than 200 microns; dark count rate below 100 kilo counts-per-second (cps), and maximum count rate above 10 Mcps.

Krainak, Michael A.↗

SiC-based Photo-detectors for UV, VUV, EUV and Soft X-ray Detection

A viewgraph presentation describing an ideal Silicon Carbide detector for ultraviolet, vacuum ultraviolet, extreme ultraviolet and soft x-ray detection is shown. The topics include: 1) An ideal photo-detector; 2) Dark current density of SiC photodiodes at room temperature; 3) Dark current in SiC detectors; 4) Resistive and capacitive feedback trans-impedance amplifier; 5) Avalanche gain; 6) Excess noise; 7) SNR in single photon counting mode; 8) Structure of SiC single photon counting APD and testing structure; 9) Single photon counting waveform and testing circuit; 10) Amplitude of SiC single photon counter; 11) Dark count of SiC APD photon counters; 12) Temperature-dependence of dark count rate; 13) Reduce the dark count rate by reducing the breakdown electric field; 14) Spectrum range for SiC detectors; 15) QE curves of Pt/4H-SiC photodiodes; 16) QE curve of SiC; 17) QE curves of SiC photodiode vs. penetration depth; 18) Visible rejection of SiC photodiodes; 19) Advantages of SiC photodiodes; 20) Competitors of SiC detectors; 21) Extraterrestrial solar spectra; 22) Visible-blind EUV detection; 23) Terrestrial solar spectra; and 24) Less than 1KeV soft x-ray detection.

Yan, Feng↗

The Preflight Photometric Calibration of the Extreme-Ultraviolet Imaging Telescope EIT

This paper presents the preflight photometric calibration of the Extreme-ultraviolet Imaging Telescope (EIT) aboard the Solar and Heliospheric Observatory (SOHO). The EIT consists of a Ritchey-Chretien telescope with multilayer coatings applied to four quadrants of the primary and secondary mirrors, several filters and a backside-thinned CCD detector. The quadrants of the EIT optics were used to observe the Sun in 4 wavelength bands that peak near 171, 195, 284, and 304 . Before the launch of SOHO, the EIT mirror reflectivities, the filter transmissivities and the CCD quantum efficiency were measured and these values are described here. The instrumental throughput in terms of an effective area is presented for each of the various mirror quadrant and filter wheel combinations. The response to a coronal plasma as a function of temperature is also determined and the expected count rates are compared to the count rates observed in a coronal hole, the quiet Sun and an active region.

EIT (EXTREME-ULTRAVIOLET IMAGING TELESCOPE)↗

Standardization of Geophysical Logging Data at the Hanford Site - 16208

Gamma activity has been measured in boreholes at the US DOE Hanford Site in southeastern Washington State since the 1940's. Over the years, detectors and data recording methods have changed, but the accumulated data provide a record of subsurface gamma activity spanning the period from active operations into interim stabilization. A basic problem is comparability of data between different detectors over a wide range of gamma activity. Many logs are simply presented in terms of raw count rate, and it is difficult to compare count rates between two different detectors, particularly when they have very different response characteristics. The Hanford Gamma Unit (HGU) is proposed as an empirical unit of gamma activity. The HGU is defined in terms of gamma activity at a specified location at the Hanford Borehole Model Facility, and its magnitude is defined such that 1 HGU is approximately equal to typical background gamma activity in uncontaminated soil. The HGU provides a means to convey information about the basic level of subsurface contamination without any implications as to the specific source of the gamma activity. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Case Study Correlating Innovative Gamma Ray Scanning Detection Systems Data to Surface Soil Gamma Spectrometry Results - 13580

HydroGeoLogic (HGL), Inc. completed a United States Environmental Protection Agency (USEPA) study to characterize radiological contamination at a site near Canoga Park, California. The characterized area contained 470 acres including the site of a prototype commercial nuclear reactor and other nuclear design, testing, and support operations from the 1950's until 1988 [1]. The site history included radiological releases during operation followed by D and D activities. The characterization was conducted under an accelerated schedule and the results will support the project remediation. The project has a rigorous cleanup to background agenda and does not allow for comparison to risk-based guidelines. To target soil sample locations, multiple lines of evidence were evaluated including a gamma radiation survey, geophysical surveys, historical site assessment, aerial photographs, and former worker interviews. Due to the time since production and decay, the primary gamma emitting radionuclide remaining is cesium-137 (Cs-137). The gamma ray survey covered diverse, rugged terrain using custom designed sodium iodide thallium-activated (NaI(Tl)) scintillation detection systems. The survey goals included attaining 100% ground surface coverage and detecting gamma radiation as sensitively as possible. The effectiveness of innovative gamma ray detection systems was tested by correlating field Cs-137 static count ratios to Cs-137 laboratory gamma spectrometry results. As a case study, the area encompassing the former location of the first nuclear power station in the U. S. was scanned, and second by second global positioning system (GPS)-linked gamma spectral data were evaluated by examining total count rate and nuclide-specific regions of interest. To compensate for Compton scattering from higher energy naturally occurring radionuclides (U-238, Th-232 and their progeny, and K-40), count rate ratios of anthropogenic nuclide-specific regions of interest to the total count rate were calculated. From the scanning data, locations with observed Cs-137 ratios exceeding six standard deviations above the mean ratio were mapped in high resolution [2]. Field teams returned to those locations to collect static count measurements using the same detection systems. Soil surface samples were collected at 30 locations and analyzed for Cs-137. An exponential correlation was identified between Cs-137 concentrations in surface soil and field-scanned Cs-137 ratios. The data indicate field minimum detectable concentration (MDC) of Cs-137 at 0.02 Bq/g (0.5 pCi/g) or lower depending on contaminant distribution in soil. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low- to Mid-Latitude X-Ray Emission from Jupiter

The Chandra X-ray Observatory (CXO) observed Jupiter during the period 2003 February 24-26 for approx.40 hours (4 Jupiter rotations), using both the spectroscopy array of the Advanced CCD Imaging Spectrometer (ACIS-S) and the imaging array of the High-Resolution Camera (HRC-I). Two ACIS-S exposures, each approx.8.5 hr long, were separated by an HRC-I exposure of approx.20 hr. The low- to mid-latitude non-auroral disk X-ray emission is much more spatially uniform than the auroral emission. However, the low- to mid-latitude X-ray count rate shows a small but statistically significant hour angle dependence, and is higher in regions of relatively low surface magnetic field strength, confirming ROSAT results. In addition, the spectrum from the low surface field region shows an enhancement in the energy band 1.14- 1.38 keV, perhaps partly due to line emission from that region. Correlation of surface magnetic field strength with count rate is not found for the 2000 December HRC-I data, at a time when solar activity was high. The low- to mid-latitude disk X-ray count rate observed by the HRC-I in the 2003 February observation is about 50% of that observed in 2000 December, roughly consistent with a decrease in the solar activity index (F10.7 cm flux) by a similar amount over the same time period. The low- to mid-latitude X-ray emission does not show any oscillations similar to the -45 minute oscillations sometimes seen from the northern auroral zone. The temporal variation in Jupiter's non-auroral X-ray emission exhibits similarities to variations in solar X-ray flux observed by GOES and TIMED/SEE. The two ACIS-S 0.3-2 keV low- to mid-latitude X-ray spectra are harder than the auroral spectrum, and are different from each other at energies above 0.7 keV, showing variability in Jupiter s non-auroral X-ray emission on a time scale of a day. The 0.3-2.0 keV X-ray power emitted at low- to mid-latitudes is 0.21 GW and 0.39 GW for the first and second ACIS-S exposures, respectively. We suggest that X-ray emission from Jupiter's disk may be largely generated by solar X-rays resonantly and fluorescently scattered in its upper atmosphere, especially at times of high incident solar X-ray flux. However, the correlation of higher count rate with low surface magnetic-field strength indicates the presence of some secondary component, possibly ion precipitation from radiation belts closer to the planet than elsewhere at low- to mid-latitudes.

Bhardwaj, Anil↗

Neutron Screening Measurements of 110 gallon drums at T Plant

The Pacific Northwest National Laboratory (PNNL) Nondestructive Assay (NDA) Service Center was contracted to develop and demonstrate a simple and inexpensive method of assaying 110 gallon drums at the Hanford Site’s T-Plant. The drums contained pucks of crushed old drums used for storage of transuranic (TRU) waste. The drums were to be assayed to determine if they meet the criteria for TRU or Low Level Waste (LLW). Because of the dense matrix (crushed steel drums) gamma measurement techniques were excluded and a mobile, configurable neutron system, consisting of four sequentially connected slab detectors was chosen to be used for this application. An optimum measurement configuration was determined through multiple test measurements with californium source. Based on these measurements the initial calibration of the system was performed applying the isotopic composition for aged weapon-grade plutonium. A series of background and blank puck drum measurements allowed estimating detection limits for both total (singles) and coincidence (doubles) counting techniques. It was found that even conservative estimates for minimum detection concentration using singles count rate were lower than the essential threshold of 100 nCi/g. Whereas the detection limit of coincidence counting appeared to be about as twice as high of the threshold. A series of measurements intended to verify the technique and revise the initial calibration obtained were performed at the Waste Receiving and Processing (WRAP) facility with plutonium standards. Standards with a total mass of 0.3 g of plutonium (which is estimated to be equivalent of 100 nCi/g for net waste weight of 300 kg) loaded in the test puck drum were clearly detected. The following measurements of higher plutonium loadings verified the calibration factors obtained in the initial exercise. The revised and established calibration factors were also confirmed within established uncertainties by additional measurements of plutonium standards in various locations in the test drum. Due to necessity to dispense the blank test drum an alternative method of baseline determination was established during field measurements. Count rates of ambient background were corrected by the differences between observed background and blank test drum count rates which were previously determined over a series of measurements. Only 31 drums out of 352 counted during the intensive measurement campaign at T-Plant were determined to be Suspect TRU. 25 of these drums were re-measured at the WRAP facility using the SuperHENC. Of the 25 drums measured, 21 were confirmed to be TRU and the remaining four LLW.

neutron measurements, TRU waste, T-Plant, configur↗

Low- to Middle-Latitude X-Ray Emission from Jupiter

The Chandra X-ray Observatory (CXO) observed Jupiter during the period 24-26 February 2003 for approx. 40 hours (4 Jupiter rotations), using both the spectroscopy array of the Advanced CCD Imaging Spectrometer (ACIS-S) and the imaging array of the High-Resolution Camera (HRC-I). Two ACIS-S exposures, each -8.5 hours long, were separated by an HRC-I exposure of approx. 20 hours. The low- to middle-latitude nonauroral disk X-ray emission is much more spatially uniform than the auroral emission. However, the low- to middle-latitude X-ray count rate shows a small but statistically significant hour angle dependence and depends on surface magnetic field strength. In addition, the X-ray spectra from regions corresponding to 3-5 gauss and 5-7 gauss surface fields show significant differences in the energy band 1.26-1.38 keV, perhaps partly due to line emission occurring in the 3-5 gauss region but not the 5-7 gauss region. A similar correlation of surface magnetic field strength with count rate is found for the 18 December 2000 HRC-I data, at a time when solar activity was high. The low- to middle-latitude disk X-ray count rate observed by the HRC-I in the February 2003 observation is about 50% of that observed in December 2000, roughly consistent with a decrease in the solar activity index (F10.7 cm flux) by a similar amount over the same time period. The low- to middle-latitude X-ray emission does not show any oscillations similar to the approx. 45 min oscillations sometimes seen from the northern auroral zone. The temporal variation in Jupiter's nonauroral X-ray emission exhibits similarities to variations in solar X-ray flux observed by GOES and TIMED/SEE. The two ACIS-S 0.3-2.0 keV low- to middle-latitude X-ray spectra are harder than the auroral spectrum and are different from each other at energies above 0.7 keV, showing variability in Jupiter's nonauroral X-ray emission on a timescale of a day. The 0.3-2.0 keV X-ray power emitted at low to middle latitudes is 0.21 GW and 0.39 GW for the first and second ACIS-S exposures, respectively. We suggest that X-ray emission from Jupiter's disk may be largely generated by the scattering and fluorescence of solar X rays in its upper atmosphere, especially at times of high incident solar X-ray flux. However, the dependence of count rate on surface magnetic-field strength may indicate the presence of some secondary component, possibly ion precipitation from radiation belts close to the planet.

Bhardwaj, Anil↗

AE-LEE measurements at low and mid latitude

Shortly after the Low Energy Electron Experiment (LEE) on the Atmosphere Explorer-C was turned on following launch, an unexpected phenomenon was encountered at mid-latitudes, a counting rate was acquired with one maximum per roll. Recent analysis shows that these counting rates occur when the detectors are looking in the ram direction of the spacecraft and the spacecraft is near perigee, and are indeed not due to properly analyzed charged particles. After showing the probable cause of these counting rates, some upper limits to true fluxes at low altitudes in the energy range 200 eV to 25 keV from the LEE experiment are shown. OGO-4 data taken at mid-latitudes are included.

Hoffman, R. A.↗

Spectral evolution of a subclass of gamma-ray bursts observed by batse

Among the gamma-ray bursts (GRBs) observed by the Burst and Transient Source Experiment (BATSE) on board the Compton Gamma Ray Observatory we define a subclass of bursts based on similar morphology: a sharp rise followed by a longer decay time. About 7% of all the gamma-ray bursts observed by BATSE fall into this subclass. We study the spectral evolution of these bursts by fitting models to time-segmented burst spectra and find no clear distinction between the spectral evolutionary properties of this subclass and those of other bursts. Further, we study the high time resolution spectral evolution of this subclass of GRBs using their spectral hardness ratios. A majority of the bursts show hardness ratio leading the counting rate and also display a continuous hard to soft evolution. The time lag between the counting rate and the hardness ratio is found to be directly correlated with the rise time of the counting rate profile. We also find, for the first time, evidence for spectral variation in a timescale of 64 ms.

Bhat, P. N.↗

Assess How Changes in Fuel Cycle Operation Impact Safeguards

Since the beginning of commercial nuclear power generation in the 1960s, the ability of researchers to understand and control the isotopic content of spent fuel has improved. It is therefore not surprising that both fuel assembly design and fuel assembly irradiation optimization have improved over the past 50+ years. It is anticipated that the burnup and isotopics of the spent fuel should exhibit less variation over the decades as reactor operators irradiate each assembly to the optimum amount. In contrast, older spent fuel is anticipated to vary more in burnup and resulting isotopics for a given initial enrichment. Modern fuel therefore should be more uniform in composition, and thus, measured safeguards results should be easier to interpret than results from older spent fuel. With spent fuel ponds filling up, interim and long-­term storage of spent fuel will need to be addressed. Additionally after long periods of storage, spent fuel is no longer self-­protecting and, as such, the IAEA will categorize it as more attractive; in approximately 20 years many of the assemblies from early commercial cores will no longer be considered self-­protecting. This study will assess how more recent changes in the reactor operation could impact the interpretation of safeguards measurements. The status quo for spent fuel assay in the safeguards context is that the overwhelming majority of spent fuel assemblies are not measured in a quantitative way except for those assemblies about to be loaded into a difficult or impossible to access location (dry storage or, in the future, a repository). In other words, when the assembly is still accessible to a state actor, or an insider, when it is cooling in a pool, the inspectorate does not have a measurement database that could assist them in re-­verifying the integrity of that assembly. The spent fuel safeguards regime would be strengthened if spent fuel assemblies were measured from discharge to loading into a difficult or impossible to access location. The primary driver for suggesting this shift in approach is the change in robotic technology and information technology in general. It should be possible, with minimal impact to the facility, to measure each assembly every time that it is moved in the pool, with the first measurements being made at discharge. The following conclusions were reached: The total neutron count rate can be accurately predicted at any future moment in time based upon the measured count rate at discharge, provided the initial enrichment and burnup of the assembly is known at discharge. It is expected that the total neutron count rate measured at discharge will be indicative of the initial enrichment and burnup of that assembly. If the automated robot were to focus on measuring the assemblies in the rack without moving them, the time available would increase immensely.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of processing algorithms to enable high-rate microcalorimeter array operation

The millisecond-scale decay constants of microcalorimeter gamma-ray pulses present challenges for operation at high count rates needed to compete with semiconductor HPGe detectors. If using conventional optimal filtering methods, pulse records with pileup events are simply discarded, leading to a large fraction of data unused when count rates are large. For single pixel rates exceeding 1-2 Hz, improved pulse processing algorithms are needed to better deal with pileup and increase the filter throughput. A 256-pixel array operating at 10 Hz per pixel would provide a total counting rate of 2.5 kHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pneumotachometer counts respiration rate of human subject

To monitor breaths per minute, two rate-to-analog converters are alternately used to read and count the respiratory rate from an impedance pneumograph sequentially displayed numerically on electroluminescent matrices.

Graham, O.↗

A Ce-Doped LiI Scintillator Film-Based High Rate, High Spatial Resolution Neutron Anger Camera for Neutron Scattering Facilities

The 2-D position sensitive neutron detectors featuring a significantly improved count rate capacity and a sub-mm spatial resolution are in high demand by neutron scattering facilities, especially the next generation high-flux spallation neutron sources (SNSs). They are anticipated to play a crucial role in fully utilizing the unprecedentedly high neutron brightness offered by these sources. In this work, a high rate and high spatial resolution neutron Anger camera has been successfully developed based on a Ce-doped microcolumnar LiI scintillator film and the PETsys TOFPET2 ASIC readout electronics. The performance evaluation was conducted in a standard laboratory environment as well as the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) with regard to light yield, γ-ray sensitivity, neutron detection efficiency, count rate capability, spatial resolution, and position linearity. The LiI:Ce scintillator was found to have a higher light yield and a lower γ-ray sensitivity than GS20 (i.e., 11729 versus 6000 photons/n and 1.67 × 10 −5 versus on the order of 10 −4 ). The neutron detection efficiency was measured to be 63% at 4.2 Å. This camera demonstrated an exceptional count rate capability, up to at least 481 kHz without rate loss. The spatial resolution was as good as 0.47 mm. Here, the position linearity was also enhanced.

High rate↗

Detection of anomalous reactor activity using antineutrino count evolution over the course of a reactor cycle

This paper analyzes the sensitivity of antineutrino count rate measurements to changes in the fissile content of civil power reactors. Such measurements may be useful in IAEA reactor safeguards applications. We introduce a hypothesis testing procedure to identify statistically significant differences between the antineutrino count rate evolution of a standard 'baseline' fuel cycle and that of an anomalous cycle, in which plutonium is removed and replaced with an equivalent fissile worth of uranium. The test would allow an inspector to detect anomalous reactor activity, or to positively confirm that the reactor is operating in a manner consistent with its declared fuel inventory and power level. We show that with a reasonable choice of detector parameters, the test can detect replacement of 82 kg of plutonium in 90 days with 95% probability, while controlling the false positive rate at 5%. We show that some improvement on this level of sensitivity may be obtained by various means, including use of the method in conjunction with existing reactor safeguards methods. We also identify a necessary and sufficient minimum daily antineutrino count rate and a maximum tolerable background rate to achieve the quoted sensitivity, and list examples of detectors in which such rates have been attained.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗