TRAPPED AND COSMIC RADIATION MEASUREMENTS FROM EXPLORER VI
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Total radiation intensity in interplanetary space before and after solar events of March 29 and April 9, 1960
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Ionization rate and omnidirectional radiation flux in interplanetary space measured by similar ion chambers and GM tubes on Mariners 2 and 4
Energy spectra and relative abundances in galactic radiation spectra obtained by OGO-E
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
In 1964 a spark calorimeter was installed at the NOR-Amberd Station (2000 m above sea level). The advantages of this calorimeter over the ionization calorimeter are illustrated.
Data derived from 1973 statistics on 2.99 million intercity flights carrying 468 million seats were included in the calculations, yielding a total of 581 billion seat-kilometer. The average flight was 1,084 km in length, was flown at an altitude of 9.47 km, and lasted 1.41 h. The average dose rate was 0.20 mrem/h, resulting in an average passenger dose of 2.82 mrem/year and an average crewmember dose of 160 mrem/year. The average radiation dose to the total U.S. population was 0.47 mrem/person/year. These results are in good agreement with data from several experiments performed by us and others in aircraft at various altitudes and latitudes. The significance of these doses to the population is discussed.
The paper reports measurement of the antiproton-to-proton and antihelium-to-helium ratios in the 4-100 GeV/c range. A superconducting magnet spectrophotometer obtained the data during a balloon flight in May 1976. The upper limit value for the antiproton ratio is 0.0005 in the 4.2-12.5 GeV/c range. This value is only slightly higher than the expected value for a leaky box-model and nearly equal to the value expected in the Peter-Westergard model. It is suggested that this upper limit value rules out the closed galaxy model. Upper limit values for the antihelium ratio are 0.000058 in the 4-10 GeV/c range; less than 0.0001 in the 4-33 GeV/c range; and less than 0.01 in the 33-100 GeV/c range. The interpretation of the raw data is explained.
An improved calculation of the secondary production and equilibrium spectrum of positrons and electrons in the Galaxy in the energy range from 1 MeV to 100 GeV has been performed. This has been done by obtaining an analytic representation of the accelerator data which describes accurately the invariant cross-section of pions, kaons, and their antiparticles from threshold energy to about 1500 GeV. This calculation takes into account the correct angular distribution of electrons in the decay of muons and the effect of nuclei-nuclei collisions. The contributions of beta-decay positrons and knock-on electrons have been included. A comparison of the present calculations with earlier calculations and experiment is presented.
The Soviet and American parts of the experiment are described separately. Particular attention was given to the following problems: placement of the detectors; study of neutron radiation within the biosatellite; and studies of fragmentation of heavy nuclei on accelerators. Unified methods were developed for the calibration of Soviet and American detectors.
The geomagnetic field near the equator is used to measure the He-3/He-4 abundance ratio near 6 GeV/nucleon. This ratio is found to be 0.24 + or - 0.05, under the assumption that the helium rigidity spectrum has the form dI/dR = about R exp(-2.65). If all He-3 is of secondary origin, this implies an interstellar mean escape-path length of about 15 g/sq cm, a value considerably larger than that determined from observations of heavier elements but compatible with measurements of the helium isotopic ratio at lower energies.
The extensive air showers (EAS) cascade curves from the Cerenkov light lateral distribution measurements are recovered and the maximum depth fluctuations of the shower development theta x sub m both on the Cerenkov and charged EAS components are defined. At E sub 0 approximates 10 to the 18th power eV the mean content of protons is greater than 85%, and p-air cross section theta sub 0 p-air 750mb.
Events detected in a shielded plastic scintillation counter occurring in the 26 microsec preceding the arrival of an extensive air shower at ground level with local electron density or = 20 m to the -2 power and the 240 microsec after its arrival have been studied. No significant excess of events (tachyons) arriving in the early time domain have been observed in a sample of 11,585 air shower triggers.
Results are reported from the Low Energy Antiproton Experiment (LEAP), a balloon-borne instrument which was flown in August, 1987. No evidence of antiproton fluxes is found in the kinetic energy range of 120 MeV to 360 MeV, at the top of the atmosphere. The 90-percent is found confidence upper limit on the antiproton/proton ratio in this energy range is 3.5 x 10 to the -5th. In particular, this new experiment places an upper limit on the flux almost an order of magnitude below the reported flux of Buffington et al. (1981).