At least 163 records · Page 9

Corrosion Protection of Launch Infrastructure and Hardware Through the Space Shuttle Program

Corrosion, the environmentally induced degradation of materials, has been a challenging and costly problem that has affected NASA's launch operations since the inception of the Space Program. Corrosion studies began at NASA's Kennedy Space Center (KSC) in 1966 during the Gemini/Apollo Programs with the evaluation of long-term protective coatings for the atmospheric protection of carbon steel. NASA's KSC Beachside Corrosion Test Site, which has been documented by the American Society of Materials (ASM) as one of the most corrosive, naturally occurring environments in the world, was established at that time. With the introduction of the Space Shuttle in 1981, the already highly corrosive natural conditions at the launch pad were rendered even more severe by the acidic exhaust from the solid rocket boosters. In the years that followed, numerous efforts at KSC identified materials, coatings, and maintenance procedures for launch hardware and equipment exposed to the highly corrosiye environment at the launch pads. Knowledge on materials degradation, obtained by facing the highly corrosive conditions of the Space Shuttle launch environment, as well as limitations imposed by the environmental impact of corrosion control, have led researchers at NASA's Corrosion Technology Laboratory to establish a new technology development capability in the area of corrosion prevention, detection, and mitigation at KSC that is included as one of the "highest priority" technologies identified by NASA's integrated technology roadmap. A historical perspective highlighting the challenges encountered in protecting launch infrastructure and hardware from corrosion during the life of the Space Shuttle program and the new technological advances that have resulted from facing the unique and highly corrosive conditions of the Space Shuttle launch environment will be presented.

Calle, L. M.↗

Double-Shell tank Integrity program - 15533

Waste at Hanford is stored in 149 single-shell tanks and 28 double-shell tanks (DSTs). Concerns related to aging radioactive waste storage facilities throughout the US DOE complex led to Brookhaven National Laboratory (BNL) developing guidelines for structural integrity programs for tank systems (BNL-52527, Guidelines for Development of Structural Integrity Programs for DOE High-Level Waste Storage Tanks). The committee of experts who developed these guidelines is commonly known as the Tank Structural Integrity Panel (TSIP). The US DOE has subsequently adopted these guidelines, and requires site operators to have a program consistent with them (DOE M 435.1, Radioactive Waste Management Manual). The Washington River Protection Solutions, LLC (WRPS) manages the tanks for the US DOE Office of River Protection (ORP) under the Tank Operations Contract (TOC). The US DOE-ORP contractual agreement with the TOC (11-NSD-010) includes a requirement to 'maintain the tank structural integrity program as described in RPP-7574, Double-Shell tank Integrity Project Plan'. The DST integrity is maintained with a variety of activities such as ultrasonic and visual inspections, chemistry controls, corrosion monitoring and structural analyses methods. The recent loss of tank 241-AY-102 has led to the formation of the High-Level Waste Integrity Assessment Panel to evaluate the DST integrity project (DSTIP) and to recommend improvements to the DSTIP. This panel continues the DOE practice of seeking expert advice to guide the formulation and continuous assessment of tank integrity activities. The panel has concluded its work and WRPS has developed a series of tasks to implement their recommendations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion-induced microstructural developments in 316 stainless steel during exposure to molten Li 2 BeF 4 (FLiBe) salt

The microstructural evaluation and characterization of 316 stainless steel samples that were tested in molten Li 2 BeF 4 (FLiBe) salt were investigated in this study for evaluating its performance in high-temperature molten fluoride salts. Recently, 316 stainless steel and FLiBe salt are being actively considered as the main structural alloy and primary coolant of fluoride salt-cooled high-temperature reactor (FHR), a leading nuclear reactor concept for the next generation nuclear plants (NGNP). In support of the materials development for the FHR, high-temperature corrosion tests of 316 stainless steel in molten FLiBe salt at 700°C have been conducted in both bare graphite crucibles and 316 stainless steel-lined crucibles in an inert atmosphere for up to 3000 hours. The microstructure of the tested samples was comprehensively characterized using scanning electron microscopy (SEM) in conjunction with energy dispersive x-ray spectroscopy (EDS) and electron backscatter diffraction (EBSD), and scanning transmission electron microscopy (STEM) with EDS. In addition to the noticeable intergranular corrosion attack on surface, the corrosion in terms of the Cr depletion along high angle grain boundaries (15-180º) extended to 22µm in depth after 3000-hour exposure to molten FLiBe salt in graphite crucible. The coherent Σ3 grain boundary appeared high resistance to the Cr depletion. The substantial Cr depletion from the near-to-surface layer induced phase transformation from γ-martensite to α-ferrite phase (FeNi x ) during corrosion at 700ºC. Furthermore, the presence of graphite in the molten salt doubled the corrosion attack depth and led to the formation of round Mo2C, hexagonal Cr 7 C 3 and needle-like Al 4 C 3 phase within the alloy as deep as 50 µm after 3000-hour corrosion testing. Based on the microstructural analysis, the corrosion mechanisms of 316 stainless steel in molten FLiBe salt in different corrosion crucibles were illuminated through schematic diagrams. Additionally, a thermal diffusion controlled corrosion model was developed and validated by experimental data for predicting the long-term corrosion attack depth.

36 MATERIALS SCIENCE↗

Physics-informed machine learning assisted uncertainty quantification for the corrosion of dissimilar material joints

Jointing techniques like the Self-Piercing Riveting (SPR), Resistance Spot Welding (RSW) and Rivet-Weld (RW) joints are used for mass production of dissimilar material joints due to their high performance, short cycle time, and adaptability. However, the service life and safety usage of these joints can be largely impacted by the galvanic corrosion due to the difference in equilibrium potentials between the metals with the presence of electrolyte. Here, in this paper, we focus on Al-Fe galvanic corrosion and develop physics-informed machine learning based surrogate model for statistical corrosion analysis, which enables the reliability analysis of dissimilar material joints under corrosion environment. In this study, a physics-based finite element (FE) corrosion model has been developed to simulate the galvanic corrosion between a Fe cathode and an Al anode. Geometric and environmental factors including crevice gap, roughness of anode, conductivity, and the temperature of the electrolyte are investigated. Further, a thorough Uncertainty Quantification (UQ) analysis is conducted for the overall corrosion behavior of the Fe-Al joints. It is found that the electrolyte conductivity has the largest effects on the material loss and needs to be managed closely for better corrosion control. This will help in designing and manufacturing joints with improved corrosion performance.

42 ENGINEERING↗

SRB seawater corrosion project

The corrosion behavior of 2219 aluminum when exposed to seawater was characterized. Controlled corrosion experiments at three different temperatures (30, 60 and 100 C) and two different environments (seawater and 3.5 percent salt solution) were designed to elucidate the initial stages in the corrosion process. It was found that 2219 aluminum is an active catalytic surface for growth of Al2O3, NaCl, and MgO. Formation of Al2O3 is favored at lower temperatures, while MgO is favored at higher temperatures. Visible corrosion products are formed within 30 minutes after seawater exposure. Corrosion characteristics in 3.5 percent salt solution are different than corrosion in seawater. Techniques utilized were: (1) scanning electron microscopy, (2) energy dispersive x-ray spectroscopy, and (3) Auger electron spectroscopy.

Bozack, M. J.↗

In-service Inspection of Radioactive Waste Tanks at the Savannah River Site – 15410

Liquid radioactive wastes from the Savannah River Site (SRS) separation process are stored in large underground carbon steel tanks. The high level wastes are processed in several of the tanks and then transferred by piping to other site facilities for further processing before they are stabilized in a vitrified or grout waste form. Based on waste removal and processing schedules, many of the tanks will be required to be in service for times exceeding the initial intended life. Until the waste is removed from storage, transferred, and processed, the materials and structures of the tanks must maintain a confinement function by providing a barrier to the environment and by maintaining acceptable structural stability during design basis events, which include loadings from both normal service and abnormal (e.g., earthquake) conditions. A structural integrity program is in place to maintain the structural and leak integrity functions of these waste tanks throughout their intended service life. In-service inspection (ISI) is an essential element of a comprehensive structural integrity program for the waste tanks at the Savannah River Site (SRS). The ISI program was developed to determine the degree of degradation the waste tanks have experienced due to service conditions. As a result of the inspections, an assessment can be made of the effectiveness of corrosion controls for the waste chemistry, which precludes accelerated localized and general corrosion of the waste tanks. Ultrasonic inspections (UT) are performed to detect and quantify the degree of general wall thinning, pitting and cracking as a measure of tank degradation. The results from these inspections through 2013, for the 27 Type III/IIIA tanks, indicate no reportable in-service corrosion degradation in the primary tank (i.e., general, pitting, or cracking). The average wall thickness for all tanks remains above the manufactured nominal thickness minus 0.25 millimeter and the largest pit identified is approximately 1.70 millimeter deep (i.e., less than 10% through-wall). Improvements to the inspection program were recently instituted to provide additional confidence in the degradation rates. Thickness measurements from a single vertical strip along the accessible height of the primary tank have been used as a baseline to compare historical measurements. Changes in wall thickness and pit depths along this vertical strip are utilized to estimate the rate of corrosion degradation. An independent review of the ISI program methodology, results, and path forward was held in August 2009. The review recommended statistical sampling of the tanks to improve the confidence of the single strip inspection program. The statistical sampling plan required that SRS increase the amount of area scanned per tank. Therefore, in addition to the baseline vertical strip that is obtained for historical comparisons, four additional randomly selected vertical strips are inspected. To date, a total of 104 independent vertical strips along the height of the primary tank have been completed. A statistical analysis of the data indicates that at this coverage level there is a 99.5% confidence level that one of the worst 5% of all the vertical strips was inspected. That is, there is a relatively high likelihood that the SRS inspection program has covered one of the most corroded areas of any of the Type III/IIIA waste tanks. These data further support the conclusion that there are no significant indications of wall thinning or pitting. Random sampling will continue to increase the confidence that one of the worst 5% has been inspected. In order to obtain the additional vertical strips, and minimize budget and schedule impacts, data collection speed for the UT system was optimized. Prior to 2009, the system collected data at a rate of 32 square centimeters per minute. The scan rate was increased to 129 - 160 square centimeters per minute by increasing the scanner step and pixel sizes in the data acquisition set-up. Laboratory testing was utilized to optimize the scan index/pixel size such that the requirements for wall thinning and pit detection were still maintained. SRS continues to evaluate improvements to ultrasonic equipment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In-service inspection of radioactive waste tanks at the Savannah River Site - 15410

Liquid radioactive wastes from the Savannah River Site (SRS) separation process are stored in large underground carbon steel tanks. The high level wastes are processed in several of the tanks and then transferred by piping to other site facilities for further processing before they are stabilized in a vitrified or grout waste form. Based on waste removal and processing schedules, many of the tanks, will be required to be in service for times exceeding the initial intended life. Until the waste is removed from storage, transferred, and processed, the materials and structures of the tanks must maintain a confinement function by providing a barrier to the environment and by maintaining acceptable structural stability during design basis events, which include loadings from both normal service and abnormal (e.g., earthquake) conditions. A structural integrity program is in place to maintain the structural and leak integrity functions of these waste tanks throughout their intended service life. In-service inspection (ISI) is an essential element of a comprehensive structural integrity program for the waste tanks at the Savannah River Site (SRS). The ISI program was developed to determine the degree of degradation the waste tanks have experienced due to service conditions. As a result of the inspections, an assessment can be made of the effectiveness of corrosion controls for the waste chemistry, which precludes accelerated localized and general corrosion of the waste tanks. Ultrasonic inspections (UT) are performed to detect and quantify the degree of general wall thinning, pitting and cracking as a measure of tank degradation. The results from these inspections through 2013, for the 27 Type III/IIIA tanks, indicate no reportable in-service corrosion degradation in the primary tank (i.e., general, pitting, or cracking). The average wall thickness for all tanks remains above the manufactured nominal thickness minus 0.25 millimeter and the largest pit identified is approximately 1.70 millimeter deep (i.e., less than 10% through-wall). Improvements to the inspection program were recently instituted to provide additional confidence in the degradation rates. Thickness measurements from a single vertical strip along the accessible height of the primary tank have been used as a baseline to compare historical measurements. Changes in wall thickness and pit depths along this vertical strip are utilized to estimate the rate of corrosion degradation. An independent review of the ISI program methodology, results, and path forward was held in August 2009. The review recommended statistical sampling of the tanks to improve the confidence of the single strip inspection program. The statistical sampling plan required that SRS increase the amount of area scanned per tank. Therefore, in addition to the baseline vertical strip that is obtained for historical comparisons, four additional randomly selected vertical strips are inspected. To date, a total of 104 independent vertical strips along the height of the primary tank have been completed. A statistical analysis of the data indicates that at this coverage level there is a 99.5% confidence level that one of the worst 5% of all the vertical strips was inspected. That is, there is a relatively high likelihood that the SRS inspection program has covered one of the most corroded areas of any of the Type III/IIIA waste tanks. These data further support the conclusion that there are no significant indications of wall thinning or pitting. Random sampling will continue to increase the confidence that one of the worst 5% has been inspected. In order to obtain the additional vertical strips, and minimize budget and schedule impacts, data collection speed for the UT system was optimized. Prior to 2009, the system collected data at a rate of 32 square centimeters per minute. The scan rate was increased to 129 - 160 square centimeters per minute by increasing the scanner step and pixel sizes in the data acquisition set-up. Laboratory testing was utilized to optimize the scan index/pixel size such that the requirements for wall thinning and pit detection were still maintained. SRS continues to evaluate improvements to ultrasonic equipment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sustaining Human Space Flight: From the Present to the Future

This slide presentation reviews some of the efforts to ensure that human space flight continues in NASA. With the aging shuttle orbiter fleet, some actions have been taken to assure safe operations. Some of these are: (1) the formation of a Corrosion Control Review Board (CCRB) that will assess the extent and cause of corrosion to the shuttle, and provide short term and long term corrective actions, among other objectives, (2) a formalization of an aging vehicle assessment (AVA) as part of a certification for the Return-to-Flight, (3) an assessment of the age life of the materials in the space shuttle, and (4) the formation of the Aging Orbiter Working Group (AOWG). There are also slides with information about the International Space Station. There is also information about the need to update the Kennedy Space Center, to sustain a 21st century launch complex and the requirement to further the aim of commercial launch capability.

Russell, Rick↗

A Multi-Scale Computational Platform for Predictive Modeling of Corrosion in Al-Steel Joints (Final Report)

The research team proposed to develop innovative multi-scale models to predict corrosion and the resulting mechanical performances in aluminum-steel joints. The methods of joining considered are resistance spot welding, self-piercing riveting, and rivet-welding, all suitable for mass production applications. The multi-scale models integrate high throughput first-principle calculations based on density functional theory (DFT), high throughput calculation of phase diagrams (CALPHAD) modeling, and finite element method (FEM) simulations. These models are to be validated through laboratory experiments. Furthermore, the models are available as open source so as to enable scientists and engineers in the community to adapt and contribute to the development and application. The approaches rely on the research team’s extensive experience on the prediction of properties of individual phases at finite temperatures and variable compositions through DFT calculations, and our broad expertise on dissimilar material joining and their corrosion. The proposed computational framework enables high throughput computations for improved predictions of corrosion and the associated mechanical performance in dissimilar material joints, resulting in significant reduction in computational time needed by the current state-of-the-art methods. With the participation of researchers from three universities, an auto manufacturer, two manufacturing technology/equipment suppliers, and a software developer/vendor, the interdisciplinary research team applies the technical development on both phase-based modeling and laboratory experiments into the automobile body joining processes for validation and technology demonstration. The global cost of corrosion was estimated at about 3.4% of the global GDP in 2013. By using available corrosion control practices, it is estimated a saving between 15-35% of the cost of corrosion. In the U.S., more than $276 billion is spent repairing corrosion damage. Prediction of the corrosion and its impact on performance of the dissimilar material joints is critical for reducing the massive number of the current corrosion-based recalls for automobiles. Thus, the project goal is to develop models to enable predictive maintenance and end-of-life planning of multi-metal joints with risk of corrosion under different conditions such as exposure to high temperatures in summer and salt solutions in winter, quantified through its pH. An academia-industry consortium led by the University of Michigan and including Pennsylvania State University, University of Illinois Urbana-Champaign, University of Georgia, General Motors Company, Livermore Software Technology Corporation, and Optimal Process Technologies, LLC. created multi-scale models for prediction of corrosion in aluminum-steel joint structures such of them used in vehicle subassemblies – chassis and transmission systems. Starting from the first principle calculations, the team developed mathematical and data-driven models to predict the metallic components, which are formed during joining of two metals, for example aluminum and steel - a lightweight multilateral system which is currently used in more than 60% car bodies. These models were used for simulating chemical reactions that are happening when the joining metallic components are exposed to high temperatures and different pH values. The team was able to predict how the corrosion installs on the metallic components and how they lead to a sudden failure of components in cars. Newly developed machine learning algorithms combining Science, Technology, Engineering and Math disciplines, advanced finite element simulation and experimental validations have been integrated in a platform for prediction of the corrosion evolution and prediction the failure of joints under mechanical loadings and fatigue. Moreover, based on machine learning and inverse analysis, the team proposed solutions for designing new metallic alloys less susceptible to corrosion when joining multi-material assembles. An average of 4% error compared with experiments was achieved for the most common joints that are used in vehicle subassemblies.

36 MATERIALS SCIENCE↗

Design and Materials of Reference Electrodes for Radioactive Waste Tank Service – A Literature Review

The Hanford site stores approximately 55 million gallons of radioactive and chemically hazardous wastes from the production of weapons materials. The wastes are stored in 177 underground, carbon steel storage tanks, 149 of these are single shell tanks (SSTs) and 28 of these are double shell tanks (DSTs). The DSTs provide critical retrieval and interim storage before the waste is vitrified in the Waste Treatment and Isolation Plant (WTP). The DSTs have been in service for 38 to 56 years and current plans indicate that WTP operations will be completed in 2075. Thus, the tanks will need to remain in service far beyond the initial 40-year life expectancy. For life extension of the tanks, effective corrosion control practices must remain in force. This effort includes direct measurements of the extent of corrosion (e.g., ultrasonic measurements and corrosion coupons) and electrochemical processes (e.g., linear polarization measurements).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High-Performance Polyimide Powder Coatings

Researchers at NASA's Kennedy Space Center have developed advanced powder coatings for longer-lasting, improved corrosion control. The results of preliminary tests of the coatings and their resistance to salt spray corrosion are very encouraging, and commercial partners are sought for further development.

coatings↗

Atmospheric corrosion model and monitor for low cost solar arrays

An atmospheric corrosion model and corrosion monitoring system has been developed for low cost solar arrays (LSA). The corrosion model predicts that corrosion rate is the product of the surface condensation probability of water vapor and the diffusion controlled corrosion current. This corrosion model is verified by simultaneous monitoring of weather conditions and corrosion rates at the solar array test site at Mead, Nebraska.

Kaelble, D. H.↗

Development of a Robust Reference Electrode in Aggressive Chemical and Radiation Environments in the Hanford Waste Tanks

The Hanford site stores more than 200 million liters of radioactive and chemically hazardous wastes from the production of weapons materials. The wastes are stored in 177 underground carbon-steel storage tanks, separated between 149 single shell tanks (SSTs) and 28 double shell tanks (DSTs). The DSTs provide critical retrieval and interim storage before the waste is vitrified in the Waste Treatment and Isolation Plant (WTP). The tanks will need to remain in-service far beyond the initial 40-year design life, and effective corrosion control practices must remain in force to extend the tanks’ lifespans. This effort includes direct measurements of corrosion rate (e.g., ultrasonic measurements and corrosion coupons) and electrochemical processes (e.g., linear polarization measurements and open circuit potential measurements). The Hanford site began monitoring the corrosion potential in select DSTs in 2008. Of the 45 reference electrodes that have been installed, 29 have failed and 6 others provided unreliable results. DOE-EM is supporting a 3-year program to develop a chemical and radiation resistant reference electrode for application in the Hanford tanks. The first year of the program focused on understanding the failure mechanism for the reference electrodes and identification of candidate construction materials that would mitigate degradation of the electrodes in the waste environment. During the second year of the program, the objectives were to: 1) test candidate materials under simulated waste conditions, 2) design components that will extend the service life of the electrode, 3) fabricate materials for prototype reference electrodes, and 4) assemble prototype reference electrodes for accelerated testing. The reference electrode is constructed of four principal parts: 1) junction, 2) casing, 3) inner chamber backfill materials, and 4) the sensing wire. Principally, improvements of the junction, casing, and inner chamber backfill materials are being pursued. The junction material at the interface between the waste and the inner chamber of the reference electrode was identified as a critical component in the failure of the reference electrodes. Nine candidate replacement junction materials were tested under simulated waste conditions to evaluate permeation rate. These materials included a variety of polymeric and ceramic materials, some of which were 3-D printed. Thus far, porous polyvinylidene fluoride materials have performed satisfactorily and are being considered for prototype development. The commercial electrode casing materials in general have performed well. Additionally, 3-D printing of chemically and mechanically stable materials is being investigated as a means for further improvement in fabrication consistency. SRNL has also investigated altering the reference electrode design to extend the service life. The new design of the interior of the reference electrode casing creates a longer, more tortuous path between the junction material and the electrode sensing wire. A finite element model was used to optimize the design without adversely impacting the circuit resistance of the electrode during the measurements, thus preserving the measurement accuracy while enhancing the service life. The inner chamber back fill materials are also critical to the performance of the reference electrode. Materials that are resistant to intruding tank waste and provide a conductive path to the sensing wire were investigated. Gel and powder materials that are interspersed with a conductive chloride bearing material were tested for their influence on diffusion and electrode resistance. All the investigated materials and components will be assembled, with collaboration from commercial vendors, to fabricate the initial prototypes. Accelerated testing of the prototypes will be initiated in Year 2 of the program and will be completed in Year 3. A recommendation on the materials of construction and the design of the new robust reference electrode will be presented to the Hanford tank farm facility.

Sykes, Kiana [Savannah River National Laboratory (↗

Evaluating Corrosion in SAVY Containers using Non-Destructive Techniques

Powerpoint presentation on Ultrasonic and Eddy Current NDT; UT Theory; Eddy current (ECA): How it works; Controlled Corrosion at NM Tech; Results – HCl Corrosion; Waveform Data for 10M HCl; Accuracy Statistics; Results – FeCl 3 Pitting; Waveforms for Anhydrous FeCl 3 ; Analyzing Corroded Stainless Steel 316L Plates; 316L Plate to Imitate Pitting; ECA Pit Depth Calibration Curve; C Scan Imaging; UT Pit Detection; SST Containers: Ultrasonic (UT) vs. CMM; UT Data Analysis; UT Conclusions and Observations; ECA Conclusions; Automated System Vision.

36 MATERIALS SCIENCE↗

Long-Term Corrosivity at NASA Kennedy Space Center as a Function of Distance and Time from the Atlantic Ocean

Long-term data to record both seasonal and notional bounding values for corrosivity at multiple sites at NASA Kennedy Space Center was needed to make better materials choices for NASA-based ground and spaceflight programs. The data was valuable for two key reasons, 1) to measure corrosion rate and chloride concentration as a function of time and distance from the Atlantic Ocean, and 2) compare the corrosivity at launchpad and site-specific areas to the more accelerated conditions at the KSC Beachside Atmospheric Corrosion Test Site for coating and materials performance prediction. Sites were chosen from 45 meter (150 feet) to 8 kilometers (5 miles) from the Atlantic Ocean and corrosion variables at each site were measured throughout each year from June 2017 to April 2023, except the Beachside site, which includes data from November 2010. The summary includes corrosivity data and coating performance comparisons at select sites, which will be used as the updated NASA corrosivity standard for corrosion control requirements.

NASA↗

PH and Electrochemical Responsive Materials for Corrosion Smart Coating Applications

Corrosion is a costly issue for military operations and civil industries. While most corrosion initiates from localized corrosion form, such as pitting, failure directly caused by localized corrosion is the most dangerous kind, because it is difficult to anticipate and prevent, occurs very suddenly and can be catastrophic. One way of preventing these failures is with a coating that can detect and heal localized corrosion. pH and other electrochemical changes are often associated with localized corrosion, so it is expected that materials that are pH or otherwise electrochemical responsive can be used to detect and control corrosion. This paper will review various pH and electrochemical responsive materials and their potential applications in corrosion smart coatings. Current research results in this field will also be reported.

Li, Wenyan↗

Experimental Design for the Evaluation of Detection Techniques of Hidden Corrosion Beneath the Thermal Protective System of the Space Shuttle Orbiter

The detection of corrosion beneath Space Shuttle Orbiter thermal protective system is traditionally accomplished by removing the Reusable Surface Insulation tiles and performing a visual inspection of the aluminum substrate and corrosion protection system. This process is time consuming and has the potential to damage high cost tiles. To evaluate non-intrusive NDE methods, a Proof of Concept (PoC) experiment was designed and test panels were manufactured. The objective of the test plan was three-fold: establish the ability to detect corrosion hidden from view by tiles; determine the key factor affecting detectability; roughly quantify the detection threshold. The plan consisted of artificially inducing dimensionally controlled corrosion spots in two panels and rebonding tile over the spots to model the thermal protective system of the orbiter. The corrosion spot diameter ranged from 0.100" to 0.600" inches and the depth ranged from 0.003" to 0.020". One panel consisted of a complete factorial array of corrosion spots with and without tile coverage. The second panel consisted of randomized factorial points replicated and hidden by tile. Conventional methods such as ultrasonics, infrared, eddy current and microwave methods have shortcomings. Ultrasonics and IR cannot sufficiently penetrate the tiles, while eddy current and microwaves have inadequate resolution. As such, the panels were interrogated using Backscatter Radiography and Terahertz Imaging. The terahertz system successfully detected artificially induced corrosion spots under orbiter tile and functional testing is in-work in preparation for implementation.

Kemmerer, Catherine C.↗