Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONVERTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

AutoTG: Reinforcement Learning-Based Symbolic Optimization for AI-Assisted Power Converter Design

Power converters are pervasive in modern electronic component design. They can be found in all electronic devices from household appliances and cellphone chargers to vehicles. Currently, designing new circuit topologies is hard because it requires human expertise based on experience and is difficult to automate. However, artificial-intelligence-assisted design can significantly facilitate the development of new power converters and/or improve the final result. Intelligently designed highly efficient power converters can have a significant effect on many important attributes, such as power efficiency, layout size, cost, heat dissemination, energy requirements, etc. We propose Autonomous Topology Generator (AutoTG), a reinforcement-learning-based framework that generates power converter topology candidates based on user specifications, optimized for user preferences. By modeling power converter design as a symbolic optimization problem, we sequentially sample components in an autoregressive manner until new topologies are formed, providing both the topology specification and the sizing (magnitude of each component parameter) of the proposed power converter. Here, we provide an empirical evaluation and show that AutoTG is able to generate varied high-efficiency topologies within component restrictions based on user input and show that previously unknown topologies can be found for further evaluation.

(AI)-based design↗

Sensitivity analysis of the technical and economic feasibility of converter-interfaced CHP System

The adoption of small-to-medium sized (1MW~20MW) combined heat and power (CHP) system is lagging, especially in industrial and commercial applications. Our prior research has proved that interfacing CHP with grid-ready converters can increase its economic value and technical benefits; this paper is focused on investigating the critical parameters impacting profitability of converter-interfaced CHP, including CHP sizing scenario, energy price, generator cost, converter cost, voltage support price, converter to engine size ratio and interconnection delay. An automatic toolkit for evaluating CHP return on investment (ROI) is developed to enhance the computation capability and efficiency. Based on varying the value of critical parameters, 975 use cases are analyzed. Results show that the profitability of converter-interfaced CHP over directly-coupled CHP is more sensitive to energy price, delays in interconnection process, converter cost and much less to generator cost or voltage support price.

converter, CHP, ROI, economic feasibility, sensiti↗

Projecting Power Converter Specific Power Through 2050 for Aerospace Applications

In order to analyze the potential fuel burn benefit from the electrification of aircraft powertrains, it is important to quantify the amount of weight that will be added to the aircraft for each additional component of the electric powertrain. This paper provides a projection of the specific power and efficiency of power converters, (AC-DC, DC-AC, or DC-DC), through the year 2050. Data was first collected on state of the art power converters in multiple application areas, creating a power converter database. Relevant specific powers were added to a set of historical data from 1976-2020, and then three different logistic curves were fit through the historical data to represent S-curve shaped growth through the year 2050. The three curves were differentiated by conservative, nominal, and aggressive assumptions for the year in which the logistic curve begins to bend down towards slower growth. With a 30% knockdown factor accounting for the additional weight required for a high altitude converter, projections range from the aggressive specific power projection of 52.9 kW/kg in 2050 to a much more conservative specific power of 12 kW/kg in which growth is limited due to certifiability concerns. Little historical data was found on converter efficiencies to project efficiency based on historical trends. Projections are based on expert opinion on yearly decreases in converter losses. 2050 projections range from 0.987 to 0.997.

fuel burn↗

A Novel Decentralized PWM Interleaving Technique for Ripple Minimization in Series-Stacked DC-DC Converters: Preprint

Cascaded dc-dc converters are commonly used in applications where distributed energy sources or loads are connected to elevated voltage levels for power transfer. In such systems, it is advantageous to minimize the ripple on the bus current and voltage by proper phase shifting of the pulse-width modulation (PWM) pulses among the converters via a method known as interleaving. Existing approaches use either a centralized controller or separate communication lines among the stacked converters to control their relative PWM switch transitions. The key drawbacks are that these methods entail significant wiring, the central controller acts as a single point of failure, and implementation on very large numbers of units is impractical. In this paper, we introduce a decentralized interleaving control (DIC) strategy that acts on local current measurements at every converter and achieves communication-free PWM interleaving among the series-stacked converters. The proposed controller is simple in structure and is shown to converge asymptotically to the interleaved state irrespective of clock drifts among the digital signal processors. Experimental results are provided for a system of five series-connected converters showing a 10 times reduction in the current ripple compared to normal operation.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Prototype and Codesign of Nascent Flexible Wave Energy Converter Concepts

Prevailing mainstream ocean wave energy converter (WEC) archetypes are often relatively large monolithic rigid bodies with singular means of power take-off (e.g., relative motion between rigid bodies) and solo prime mover mechanisms (e.g. a rotary generator, a hydraulic piston). These mainstream WEC archetypes have existed for decades with some having histories spanning more than a century of significant investments and interests. As an alternative to the domain of mainstream WEC archetypes is the domain of distributed embedded energy converter technologies (also known as DEEC-Tec). Use of DEEC-Tec to create WECs - often called flexWECs - is a nascent domain of research and development that centers itself upon the interconnection of many relatively small energy converters - very small energy transducers - that interconnect and combine to create a much larger, overall, energy converting structure. The DEEC-Tec domain enables promising possibilities such as: direct in situ ocean wave energy harvesting and conversion throughout the volume of an entire flexWEC; inherent broad-banded ocean wave energy capture and conversion arising from near semi-continuous structural degrees of freedom; an innate absence of focusing and concentrating of ocean wave energy into a single prime mover and/or transmission system; and built-in implicit redundancy. As such, the DEEC-Tec domain could revolutionize how we conceptualize ocean wave energy conversion - both in terms of ocean wave energy converter design and what we view as viable environments and circumstances for ocean wave energy conversion. The research and development opportunities for the DEEC-Tec domain, therefore, are vast compared to the prevailing mainstream ocean wave energy converter domain. Correspondingly, there are ample opportunities to invest time and money into the DEEC-Tec domain with an aim to enable a paradigm shift in how ocean waves can be utilized as a more viable form of renewable energy. To that end, two seedling efforts have been enacted providing a very cursory investigation into the DEEC-Tec domain: (1) a preliminary simple fabrication/prototyping effort and (2) a preliminary co-design effort. The prototype seedling centers upon the design of a fabrication and evaluation rig for individual DEEC-Tec transducers; e.g., dielectric elastomer generators. The co-design seedling centers upon the analysis of those methods suitable for DEEC-Tec, ocean wave energy conversion, and fluid-structure interaction co-design efforts.

50 EE - Wind and Water Power Program - Water (EE-4↗

Design, Optimization, and Validation of GaN-Based DAB Converter for Active Cell Balancing in BTMS Applications: Preprint

This paper focuses on the design of a bidirectional dual active bridge (DAB) DC/DC converter that utilizes Gallium Nitride (GaN) switches as active components. In the existing literature, MOSFET-based DAB for active cell balancing is available, but GaN-based DAB converter for active cell balancing is still new. The proposed modular isolated GaN-based DAB converter is designed as an individual module of active cell balancing for behind-the-meter storage (BTMS) applications, targeting high-power charging stations. Modular isolated converters are connected to each cell (low voltage bus), and each cell is connected in series to build up a battery module. According to the reference current command of supervisory control, each DAB converter can transfer power back and forth through the high voltage (HV) bus to balance the State of Charge (SoC) between the cells. Each module DAB converter is designed at a 50W power rating. Switch power and transformer losses are analyzed for different switching frequencies, showing the optimum switching frequency for minimum losses. Furthermore, the procedure to select the required gate driver and the PCB layout optimization are discussed. Finally, the DAB performance analysis of GaNbased DAB and Si-based DAB is provided for a battery module operating with a LiFeMnPO4 prismatic cell with 3.2V 20Ah rated values.

active cell balancing↗

Muon detection studied by pulse-height energy analysis: Novel converter arrangements

Muons are conventionally measured by a plastic scintillator–photomultiplier detector. Muons from processes in ultra-dense hydrogen H(0) are detected here by a novel type of converter in front of a photomultiplier. The muon detection yield can be increased relative to that observed with a plastic scintillator by at least a factor of 100, using a converter of metal, semiconductor (Ge), or glass for interaction with the muons penetrating through the metal housing of the detector. This detection process is due to transient formation of excited nuclei by the well-known process of muon capture, giving beta decay. The main experimental results shown here are in the form of beta electron energy spectra detected directly by the photomultiplier. Events which give a high-energy tail in the energy spectra are probably due to gamma photons from the muons. Sharp and intense x-ray peaks from a muonic aluminium converter or housing material are observed. The detection conversion in glass and Ge converters has a time constant of the order of many minutes to reach the final conversion level, while the process in metal converters is stabilized faster. The time constants are not due to lifetimes of the excited nuclei or neutrons but are due to internal charging in the insulating converter material. Interaction of this charging with the high voltage in the photomultiplier is observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation of arbitrary vector beams with liquid crystal polarization converters and vector-photoaligned q-plates

Arbitrary vector beams (VBs) are realized by the designed polarization converters and corresponding vector-photoaligned q-plates. The polarization converter is a specific twisted nematic cell with one substrate homogeneously aligned and the other space-variantly aligned. By combining a polarization-sensitive alignment agent with a dynamic micro-lithography system, various categories of liquid crystal polarization converters are demonstrated. Besides, traditional radially/azimuthally polarized light, high-order and multi-ringed VBs, and a VB array with different orders are generated. The obtained converters are further utilized as polarization masks to implement vector-photoaligning. The technique facilitates both the volume duplication of these converters and the generation of another promising optical element, the q-plate, which is suitable for the generation of VBs for coherent lasers. The combination of proposed polarization converters and correspondingly fabricated q-plates would drastically enhance the capability of polarization control and may bring more possibilities for the design of photonic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic triggering — time-resolved characterisation of silicon strip modules in the presence of switching DC-DC converters

Modules for the ATLAS Inner Tracker (ITk) strip tracker include a DC-DC converter circuit glued directly to the silicon sensor which converts the 11 V supplied to the module to the 1.5 V required for the operation of the readout chips. The DC-DC converter unit, consisting of a copper solenoid and custom ASIC, is located directly above the silicon strip sensor and therefore needs to be shielded to protect the sensor from EMI noise created during the operation of the circuit. Despite dedicated shielding, consisting of an aluminium shield box with continuous solder seams encompassing the surface components and a copper layer in the PCB beneath it, module channels connected to sensor strips located beneath the converter circuit were found to show a noise increase. While the DC-DC converter unit causing the underlying EMI noise operates at a frequency of 2 MHz, module characterisation measurements for ITk strip tracker modules are typically performed asynchronously to the DC-DC switching and are therefore averaged over the full range of time bins with respect to the converter frequency. In order to investigate the time dependence of the noise injection relative to the DC-DC switching frequency, a dedicated setup to understand the time-resolved performance change in modules was developed. By using a magnetic field probe to measure the field leaking through the shield box and triggering on its rising edge, data taking could be synchronised with the DC-DC switching. This paper illustrates the concept and setup of such time-resolved performance measurements using magnetic triggering and presents results for the observed effects on signal and noise for ATLAS ITk strip modules from both laboratory and beam tests.

47 OTHER INSTRUMENTATION↗

A Hydrokinetic Energy Conversion System using Underwater LLC-type Resonant Converter

The hydrokinetic energy of river and ocean currents is a valuable renewable energy resource. Conventional systems for harvesting hydrokinetic energy usually have bulky passive components, lengthy cables connecting the underwater turbine/generator with onshore power converters, and limited control over power generation. This paper presents a new hydrokinetic energy harvesting system using an LLC-type resonant converter that is placed underwater in close proximity to the generator. By using SiC devices and the soft switching characteristic of LLC resonant converter, the converter operates in 10s of kHz, significantly reducing the passive components. In addition, the LLC converter provides flexible power regulation of the system. Furthermore, the underwater placement of the power converter takes advantage of the cooling provided by the water and simplifies the system by reducing its connecting cable length.

Dai, Hang↗

Large-Signal Impedance Modeling of Three-Phase Voltage Source Converters

Resonance problems have become a major hurdle in the large-scale grid integration of renewable energy. It is important to be able to predict the amplitude of resonance-induced distortions for the protection and control design of power electronic converters. We recently presented an impedance-based approach for the prediction of resonance amplitude. It was shown that the impedance response of a converter starts changing with the amplitude of resonance; this blocks the amplitude growth beyond a certain point where the converter forms a limit cycle mode of sustained oscillations. The large-signal impedance of a converter captures the change in its impedance response with the resonance amplitude, and it can be used to predict the resonance amplitude under different operation conditions. This paper presents large-signal sequence impedance modeling for three-phase voltage source converters (VSC) with dq-current control and PLL. Modeling challenges encountered in the absence of the small-signal approximation are addressed by a) leveraging the dominating influence of hard nonlinearities such as pulse-width modulation saturation and limiters over soft nonlinearities in shaping the converter large-signal behavior and b) modeling the large-signal gain of hard nonlinearities using appropriate describing functions. Developed large-signal impedance models are validated using numerical simulations. Measurements of the large-signal impedance responses of a commercial 1-MW VSC-based inverter are also presented to experimentally demonstrate the effects of the injected perturbation amplitude on impedance response as predicted by the developed model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

General Space Vector Modulation of A High-Frequency AC Linked Universal Converter for Distributed Generations

A high-frequency (HF) ac linked universal converter is proposed for distributed generations interfacing three-phase ac with single-phase ac or dc. The primary and secondary of the HF isolation transformer are, respectively, formed by a three-to-single-phase matrix converter and a cyclo converter. Based on the operating principle, a general and simple to be implemented space vector modulation (SVM) is developed from that for the conventional indirect matrix converter and constantly operated virtual dual-active-bridge converter. Simulation studies carried out on different amplitudes and frequencies of single-phase ac output and dc output demonstrate effectiveness and simplicity of the proposed converter with the SVM solution.

Liu, Yushan↗

Constant Frequency ZVS PWM Converter

In this paper, a simple yet novel buck or boost adaptive zero-voltage switching (ZVS) converter topology is proposed for soft switching pulse-width modulation (PWM) dc / dc converters. The converter is designed for the high switching frequency that can achieve high efficiency by reducing switching losses for the entire load range at low and high power. Besides, the output at the load terminals is maintained by a PWM signal at a fixed switching frequency, a phase shift signal between converter ports (legs) controls the system circulating current in order to provide the ZVS condition in all load conditions. With the proposed controller, the converter, thus, is suitable for high switching frequency and high-power applications with the small volume. The proposed dc / dc converter operation is analyzed, designed, and confirmed by simulation results for 240 V input, 400 V / 5 A output, and 200 kHz operating frequency at full load.

Asa, Erdem↗

A Novel Three-Phase Isolated LLC and Non-Isolated LCL-T Resonant Converter for Fuel Cell Applications

In this paper, a novel three-phase isolated LLC and non-isolated LCL−T resonant converter topologies are introduced for fuel cell applications. In order to improve the fuel cell DC/DC converter efficiency, the current amplitude should be reduced in the power stage components. Cascaded connections of fuel cell blocks through a controllable system enable using higher voltage amplitude and bring the current amplitude lower at the target power. In this way, power losses in the passive components can be reduced, and maximum energy transfer can be established, improving the DC/DC converter efficiency from the fuel cell to the load. The introduced new converter also achieves soft switching (ZVS), minimizing the switching losses in all input and output load conditions. The presented three-phase isolated LLC and non-isolated LCL−T resonant converter systems, fed by three fuel cell modules with an output range of 190380 V, deliver 580−730 V at 450 kW maximum output power. The results reveal that the proposed systems have the advantage of reducing the size, volume, and weight and increasing the overall DC/DC converter system efficiency compared to the single-phase systems.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Medium Voltage Converter Inductor Insulation Design Considering Grid Requirements

Medium voltage (MV) SiC devices facilitate direct (without 50-/60-Hz transformer) connection of the power electronics converter to the MV grid using simple topology. Compared to the insulation design of MV inductors that have been widely used in the power system, the insulation design of the MV converter filter inductors has new challenges. Particularly, the grid impact on insulation requirements on converter filter inductors is rarely discussed. This article introduces the insulation design of a grid-side filter inductor for a 13.8-kV power conditioning system converter. The grid insulation requirements, including the short-duration power frequency overvoltage and the lightning impulse voltage, are considered in the design. To meet the requirements, the layer-to-layer insulation, winding-to-core/ground insulation, the air gap discharge between the winding and the core, the local electric field, as well as the interturn transient voltage distribution are considered. Furthermore, the designed inductors are validated by the 46 kV (>1 min) dc hi-pot test, 12-kV ac partial discharge test, one-hour single-phase converter full rating test, as well as three-phase converter full rating test.

42 ENGINEERING↗

Passivity-Based Control of Grid Forming and Grid Following Converters in Microgrids

With the integration of more and more power electronics devices into the grid, it is not easy to guarantee the stability of the whole system due to the complexity of the control structure of various power converters. In this paper, we consider grid-forming and grid-following converters in one microgrid, in which the grid-forming converters support the voltage and frequency of the microgrid and the grid-following converters inject their maximum power into the microgrid. To handle the stability issue, the passivity principle is applied to guarantee the stability of the whole microgrid. We ensure every grid-following converter satisfies the passivity via the port-controlled Hamiltonian method. In addition, we apply the passivity-based proportional-resonant controller to the grid-forming converter. One of the advantages of the proposed method is that the phase lock loop system is eliminated, which may cause stability issues. Simulation results show that the proposed method can control the microgrid effectively.

Gui, Yonghao (Young)↗

A Modular Multilevel Converter with Power Mismatch Control for Grid-Connected Photovoltaic Systems

A modular multilevel power converter configuration for grid connected photovoltaic (PV) systems is proposed. The converter configuration replaces the conventional bulky line frequency transformer with several high frequency transformers, potentially reducing the balance of systems cost of PV systems. The front-end converter for each port is a neutral-point diode clamped (NPC) multi-level dc-dc dual-active bridge (ML-DAB) which allows maximum power point tracking (MPPT). The integrated high frequency transformer provides the galvanic isolation between the PV and grid side and also steps up the low dc voltage from PV source. Following the ML-DAB stage, in each port, is a NPC inverter. N number of NPC inverters’ outputs are cascaded to attain the per-phase line-to-neutral voltage to connect directly to the distribution grid (i.e., 13.8 kV). The cascaded NPC (CNPC) inverters have the inherent advantage of using lower rated devices, smaller filters and low total harmonic distortion required for PV grid interconnection. The proposed converter system is modular, scalable, and serviceable with zero downtime with lower foot print and lower overall cost. A novel voltage balance control at each module based on power mismatch among N-ports, have been presented and verified in simulation. Analysis and simulation results are presented for the N-port converter. The converter performance has also been verified on a hardware prototype.

14 SOLAR ENERGY↗

Measurements of plasma parameters in a simulated thermionic converter

Cesium-filled thermionic energy converters are examined as candidate electrical energy sources in spacecraft requiring tens to hundreds of kilowatts of electric power. The high operating temperatures necessary for a large specific power and high efficiency inevitably impose stringent constraints on the converter fabrication to achieve the desired reliability of the power system. The converter physics for reducing operating temperatures and cesium plasma losses are studied to achieve high reliability without sacrificing the power performance of the converters. Various cesium parameters which affect the converter performance are: (1) electron temperatures, (2) plasma ion densities, and (3) electric potential profiles. These were investigated using a Langmuir probe in a simulated converter. The parameters were measured in different cesium discharge modes.

Shimada, K.↗