Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONTAINER SAMPLING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Quantifying the Site Heterogeneities of Non‐Uniform Catalysts Using QuantEXAFS

Abstract We present the Multi‐site (MS) QuantEXAFS approach, designed to model the EXAFS data from samples containing an element in different local bonding geometries. Building upon our QuantEXAFS method, which maps experimental extended X‐ray absorption fine structures (EXAFS) data to DFT‐optimized structures, MS‐QuantEXAFS introduces the key capability to probe fractional contributions of multiple sites that may be present in an experimental sample. Specifically, we demonstrate effectiveness of this technique by investigating mixed samples containing known fractions of site‐isolated subsurface Pt/MgO with Pt nanoparticles uniformly supported on MgO. The ‘site‐fractions’ obtained through MS‐QuantEXAFS closely match (i. e., ±6%) the known fractions of the physically mixed samples. This approach has been generalized to other oxides, and thus represents an important advance in quantifying the speciation of non‐uniform catalyst samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Risk analysis of earth return options for the Mars rover/sample return mission

Four options for return of a Mars surface sample to Earth were studied to estimate the risk of mission failure and the risk of a sample container breach that might result in the release of Martian life forms, should such exist, in the Earth's biosphere. The probabilities calculated refer only to the time period from the last midcourse correction burn to possession of the sample on Earth. Two extreme views characterize this subject. In one view, there is no life on Mars, therefore there is no significant risk and no serious effort is required to deal with back contamination. In the other view, public safety overrides any desire to return Martian samples, and any risk of damaging contamination greater than zero is unacceptable. Zero risk requires great expense to achieve and may prevent the mission as currently envisioned from taking place. The major conclusion is that risk of sample container breach can be reduced to a very low number within the framework of the mission as now envisioned, but significant expense and effort, above that currently planned is needed. There are benefits to the public that warrant some risk. Martian life, if it exists, will be a major discovery. If it does not, there is no risk.

Source record↗

90 Sr Liquid Scintillation Urine Analysis Utilizing Different Approaches for Tracer Recovery

90 Sr is one of the isotopes most commonly produced by nuclear fission. This medium lived isotope presents serious challenges to radiation workers, the environment, and following a nuclear event, the general public. Methods of identifying this nuclide have been in existence for a number of years (e.g. Horwitz, E.P. [1], Maxwell, S.L.[2], EPA 905.0 [3]) which are time consuming, requiring a month or more for full analysis. This time frame is unacceptable in the present security environment. It is therefore important to have a dependable and rapid method for the determination of Sr. The purposes of this study are to reduce analysis time to less than half a day by utilizing a single method of radiation measurement while continuing to yield precise results. This paper presents findings on three methods that can meet this criteria; (1) stable Sr carrier, (2) 85 Sr by gamma spectroscopy, and (3) 85 Sr by LSC. Two methods of analyzing and calculating the 85 Sr tracer recovery were investigated (gamma spectroscopy and a low energy window-Sr85LEBAB by LSC) as well as the use of two different types of Sr tracer ( 85 Sr and stable Sr carrier). Three separate stock blank urine samples were spiked with various activity levels of 239 Pu, 137 Cs, 90 Sr / 90 Y to determine the effectiveness of the Eichrome Sr-spec™ resin 2mL extractive columns. The objective was to compare the recoveries of 85 Sr versus a stable strontium carrier, attempt to compare the rate at which samples can be processed by evaluating evaporation, neutralization, and removing the use of another instrument (gamma spectrometer) by using the LSC spectrometer to obtain 85 Sr recovery. It was found that when using a calibration curve comprised of a different cocktail and a non-optimum discriminator setting reasonable results (bias of ± 25%) were achieved. The results from spiked samples containing 85 Sr demonstrated that a higher recovery is obtained when using gamma spectroscopy (89-95%) than when using the LEB window from LSC (120-470%). The high recovery for 85 Sr by LSC analysis may be due to the interference/cross talk from the alpha region since alpha counts were observed in all sample sets. After further investigation it was determined that the alpha counts were due to 239 Pu breakthrough on the Sr-spec™ column. This requires further development to purify the Sr before an accurate tracer recovery determination can be made. Sample preparation times varied and ranged from 4-6 hours depending on the specific sample preparation process. The results from the spiked samples containing stable strontium nitrate Sr(NO 3 ) 2 carrier demonstrate that gravimetric analysis yields the most consistent high recoveries (97-101%) when evaporation is carefully performed. Since this method did not have a variation on the tracer recovery method, the samples were counted in 1) LEB/Alpha/Beta mode optimized for Sr-90, 2) DPM for Sr-90, and 3) general LEB/Alpha/Beta mode. The results (from the known) ranged from 79-104%, 107-177%, and 85-89% for 1, 2, and 3 respectively. Counting the prepared samples in a generic low energy beta/alpha/beta protocol yielded more accurate and consistent results and also yielded the shortest sample preparation turn-around-time of 3.5 hours.

Piraner, Olga↗

High-Pressure X-ray Tomography Microscope: Synchrotron Computed Microtomography at High Pressure and Temperature

A new apparatus has been developed for microtomography studies under high pressure. The pressure generation mechanism is based on the concept of the widely used Drickamer anvil apparatus, with two opposed anvils compressed inside a containment ring. Modifications are made with thin aluminum alloy containment rings to allow transmission of x rays. Pressures up to 8 GPa have been generated with a hydraulic load of 25 T. The modified Drickamer cell is supported by thrust bearings so that the entire pressure cell can be rotated under load. Spatial resolution of the high pressure tomography apparatus has been evaluated using a sample containing vitreous carbon spheres embedded in FeS matrix, with diameters ranging from 0.01 to 0.2 mm. Spheres with diameters as small as 0.02 mm were well resolved, with measured surface-to-volume ratios approaching theoretical values. The sample was then subject to a large shear strain field by twisting the top and bottom Drickamer anvils. Imaging analysis showed that detailed microstructure evolution information can be obtained at various steps of the shear deformation, allowing strain partition determination between the matrix and the inclusions. A sample containing a vitreous Mg{sub 2}SiO{sub 4} sphere in FeS matrix was compressed to 5 GPa, in order to evaluate the feasibility of volume measurement by microtomography. The results demonstrated that quantitative inclusion volume information can be obtained, permitting in situ determination of P-V-T equation of state for noncrystalline materials.

43 PARTICLE ACCELERATORS↗

Oxidative Stability of Tc(I) Tricarbonyl Species Relevant to the Hanford Tank Waste

Technetium (Tc), which exists predominately in the liquid supernatant and salt cake fractions of the nuclear tank waste stored at the U.S. DOE Hanford Site, is one of the most difficult contaminants to dispose of and/or remediate. In the strongly alkaline environments prevalent in the tank waste, its dominant chemical form is pertechnetate (TcO 4 - , oxidation state +7). However, based on experimentation to-date, a significant fraction of the soluble Tc cannot be effectively separated from the wastes and may be present as a non-pertechnetate species. The presence of a non pertechnetate species significantly complicates disposition of low-activity waste (LAW), and the development of methods to either convert them to pertechnetate or to separate the non-pertechnetate species directly is needed. The challenge is the uncertainty regarding the nature and stability of the alkaline-soluble, low-valence, non pertechnetate species in the liquid tank waste. One objective of the Tc management project is to address this knowledge gap. This fiscal year (FY) 2015 report summarizes experimental work exploring the oxidative stability of model low-valence Tc(I) tricarbonyl species, derived from the [Tc(CO) 3 ] + moiety. These compounds are of interest due to their implied presence in several Hanford tank waste supernatants. Work in part was initiated in FY 2014, and a series of samples containing non-pertechnetate Tc generated ex situ or in situ in pseudo-Hanford tank supernatant simulant solutions was prepared and monitored for oxidation to Tc(VII) (Levitskaia et al. 2014). This experimentation continued in FY 2015, and new series of samples containing Tc(I) as [Tc(CO) 3 ] + •Ligand was tested. The monitoring method used for these studies was a combination of 99 Tc NMR and EPR spectroscopies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Acoustophoresis method and apparatus

A method and apparatus are provided for acoustophoresis, i.e., the separation of species via acoustic waves. An ultrasonic transducer applies an acoustic wave to one end of a sample container containing at least two species having different acoustic absorptions. The wave has a frequency tuned to or harmonized with the point of resonance of the species to be separated. This wave caused the species to be driven to an opposite end of the sample container for removal. A second ultrasonic transducer may be provided to apply a second, oppositely directed acoustic wave to prevent undesired streaming. In addition, a radio frequency tuned to the mechanical resonance and coupled with a magnetic field can serve to identify a species in a medium comprising species with similar absorption coefficients, whereby an acoustic wave having a frequency corresponding to this gyrational rate can then be applied to sweep the identified species to one end of the container for removal.

Heyman, Joseph S.↗

Acoustophoresis separation method

A method and apparatus are provided for acoustophoresis, i.e., the separation of species via acoustic waves. An ultrasonic transducer applies an acoustic wave to one end of a sample container containing at least two species having different acoustic absorptions. The wave has a frequency tuned to or harmonized with the point of resonance of the species to be separated. This wave causes the species to be driven to an opposite end of the sample container for removal. A second ultrasonic transducer may be provided to apply a second, oppositely directed acoustic wave to prevent undesired streaming. In addition, a radio frequency tuned to the mechanical resonance and coupled with a magnetic field can serve to identify a species in a medium comprising species with similar absorption coefficients, whereby an acoustic wave having a frequency corresponding to this gyrational rate can then be applied to sweep the identified species to one end of the container for removal.

Heyman, Joseph S.↗

Thermoelectric properties and impedance spectroscopy of polycrystalline samples of the beta-gallia rutile intergrowth, (Ga,In){sub 4}(Sn,Ti){sub 5}O{sub 16}

Polycrystalline samples of Ga{sub 3}In(Sn{sub 1-y}Ti{sub y}){sub 5}O{sub 16}, y{<=}0.3 were prepared by solid-state synthesis and characterized to determine their optical properties, thermoelectric properties and electrical impedance. Using diffuse reflectance data and assuming a direct band gap, the band gap of the material ranges from 3.58 eV for y=0 to 3.74 eV for y=0.2. The dc conductivity decreased with increasing Ti content and was thermally activated, ranging from {<=}10{sup -5} S/cm at 300 Degree-Sign C to 0.03 S/cm at 1000 Degree-Sign C for Ga{sub 3}InSn{sub 5}O{sub 16}. The Seebeck coefficient was negative indicating n-type conduction. The activation energies for dc conduction and thermopower were similar, ranging from 1.4{+-}0.1 eV for y=0 to 1.8{+-}0.2 eV for y=0.2, suggesting band conduction. The thermal conductivity of Ga{sub 3}InSn{sub 5}O{sub 16} ranged from 1.1 W/m K at 500 {sup o}C to 0.75 W/m K at 800 Degree-Sign C. The highest figure of merit measured was 2 Multiplication-Sign 10{sup -4} at {approx}900 Degree-Sign C, which is much lower than desired for thermoelectric materials. A comparison of dc conductivity and impedance data indicated a substantial ionic contribution for samples containing titanium. - Graphical abstract: The thermoelectric properties of polycrystalline Ga{sub 3}In(Sn{sub 1-y}Ti{sub y}){sub 5}O{sub 16}, y{<=}0.3 were measured in air at 300-900 Degree-Sign C. The materials are broad-band n-type semiconductors with non-negligible ionic conduction for samples prepared with y>0. The thermoelectric figure of merit is much lower than desired for practical thermoelectric devices. Highlights: Black-Right-Pointing-Pointer Ga{sub 3}In(Sn{sub 1-y}Ti{sub y}){sub 5}O{sub 16}, y{<=}0.2 is a broad-band n-type semiconductor. Black-Right-Pointing-Pointer The conductivity of Ti-containing samples show evidence of an ionic as well as an electronic contribution. Black-Right-Pointing-Pointer The thermal conductivity of polycrystalline Ga{sub 3}In(Sn{sub 1-y}Ti{sub y}){sub 5}O{sub 16} decreases with increasing temperature. Black-Right-Pointing-Pointer The thermoelectric figure of merit for Ga{sub 3}In(Sn{sub 1-y}Ti{sub y}){sub 5}O{sub 16} is lower than desired for practical thermoelectric devices.

36 MATERIALS SCIENCE↗

Methods and compositions for rapid thermal cycling

The rapid thermal cycling of a material is targeted. A microfluidic heat exchanger with an internal porous medium is coupled to tanks containing cold fluid and hot fluid. Fluid flows alternately from the cold tank and the hot tank into the porous medium, cooling and heating samples contained in the microfluidic heat exchanger's sample wells. A valve may be coupled to the tanks and a pump, and switching the position of the valve may switch the source and direction of fluid flowing through the porous medium. A controller may control the switching of valve positions based on the temperature of the samples and determined temperature thresholds. A sample tray for containing samples to be thermally cycled may be used in conjunction with the thermal cycling system. A surface or internal electrical heater may aid in heating the samples, or may replace the necessity for the hot tank.

42 ENGINEERING↗

Methods and compositions for rapid thermal cycling

The rapid thermal cycling of a material is targeted. A microfluidic heat exchanger with an internal porous medium is coupled to tanks containing cold fluid and hot fluid. Fluid flows alternately from the cold tank and the hot tank into the porous medium, cooling and heating samples contained in the microfluidic heat exchanger's sample wells. A valve may be coupled to the tanks and a pump, and switching the position of the valve may switch the source and direction of fluid flowing through the porous medium. A controller may control the switching of valve positions based on the temperature of the samples and determined temperature thresholds. A sample tray for containing samples to be thermally cycled may be used in conjunction with the thermal cycling system. A surface or internal electrical heater may aid in heating the samples, or may replace the necessity for the hot tank.

36 MATERIALS SCIENCE↗

Metastable Radioxenon Verification Laboratory (MRVL) Year-End Report

This is the year end report that is due to the client. The MRVL system is designed to measure multiple radioxenon isotopes ( 135 Xe, 133 Xe, 133 mXe and 133 mXe) simultaneously. The system has 12 channels to load samples and make nuclear measurements. Although the MRVL system has demonstrated excellent stability in measurements of Xe-133 and Xe-135 over the year of evaluation prior to delivery, there has been concern about system stability over measurements performed on samples with orders of magnitude different radioactivity, and samples containing multiple isotopes. To address these concerns, a series of evaluation test have been performed at the end-user laboratory. The evaluation was performed in two separate phases. Phase 1 made measurements on isotopically pure Xe-133 from high radioactivity down to the system background levels of activity, addressing the potential count rate dependencies when activities change from extreme high to very low. The second phase performed measurements on samples containing multiple isotopes (Xe-135, Xe-133 and Xe-133m), and addressed concerns about the dependence of isotopic concentrations on the presence of additional isotopes. The MRVL showed a concentration dependence on the Xe-133 due to the amount of Xe-133m that was in the sample. The dependency is due to the decay of Xe-133m into Xe-133. This document focuses on the second phase and will address the analysis used to account for ingrowth of Xe-133 from Xe-133m.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heterogeneous in-situ nanostructure contributes to the thermoelectric performance of Zn{sub 4}Sb{sub 3}

Single-phase Zn{sub 4}Sb{sub 3} and ZnSb-containing samples were prepared by Plasma Activated Sintering. An abrupt decrease of thermal conductivity was found at about 400 K, which is attributed to the microstructure change of Zn{sub 4}Sb{sub 3}. Nanoscale inclusions and compositional inhomogeneities were found in Zn{sub 4}Sb{sub 3} sample at 473 K by high-resolution transmission electron microscopy. The phonon scattering is enhanced by increasing grain boundaries and chaotic structure, which reduces the thermal conductivity and increases the thermoelectric performance of Zn{sub 4}Sb{sub 3} at elevated temperature. The Rietveld refinement results show that large ZnSb grains in ZnSb-containing samples will accommodate excess Zn atoms, and then reduce thermoelectric performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Exothermic furnace module

An exothermic furnace module is disclosed for processing materials in space which includes an insulated casing and a sample support, carried within the casing which supports a sample container. An exothermic heat source includes a plurality of segments of exothermic material stacked one upon another to produce a desired temperature profile when ignited. The exothermic material segments are constructed in the form of an annular element having a recess opening which defines an open central core throughout the vertical axis of the stacked exothermic material. The sample container is arranged within the core of the stacked exothermic heating material.

Poorman, R. M.↗

Microstructure investigations of Yb- and Bi-doped Mg{sub 2}Si prepared from metal hydrides for thermoelectric applications

Within the field of thermoelectric materials for energy conversion magnesium silicide, Mg{sub 2}Si, is an outstanding candidate due to its low density, abundant constituents and low toxicity. However electronic and thermal tuning of the material is a required necessity to improve its Figure of Merit, zT. Doping of Yb via reactive YbH{sub 2} into the structure is performed with the goal of reducing the thermal conductivity. Hydrogen is released as a by-product at high temperatures allowing for facile incorporation of Yb into the structure. We report on the properties of Yb- and Bi-doped Mg{sub 2}Si prepared with MgH{sub 2} and YbH{sub 2} with the focus on the synthetic conditions, and samples’ microstructure, investigated by various electron microscopy techniques. Yb is found in the form of both Yb{sub 3}Si{sub 5} inclusions and Yb dopant segregated at the grain boundary substituting for Mg. The addition of 1 at% Yb concentration reduced the thermal conductivity, providing a value of 30 mW/cm K at 800 K. In order to adjust carrier concentration, the sample is additionally doped with Bi. The impact of the microstructure on the transport properties of the obtained material is studied. Idealy, the reduction of the thermal conductivity is achieved by doping with Yb and the electronic transport is adjusted by doping with Bi. Large grain microstructure facilitates the electronic transport. However, the synthetic conditions that provide the optimized microstructure for electrical transport do not facilitate the additional Yb dopant incorporation. Therefore, the Yb and Bi containing sample with the optimized microstructure provides a zT=0.46 at 800 K. - Graphical abstract: 1% or less addition of YbH{sub 2} to Mg{sub 2}Si significantly reduces the thermal conductivity of the material. Yb replaces some Mg in Mg{sub 2}Si and the remainder is distributed as Yb{sub 3}Sb{sub 5} in the Yb-doped Mg{sub 2}Si matrix. Correlation between the observed grain size and transport show the difficulty in simultaneously reducing the thermal conductivity with optimal electronic properties.

36 MATERIALS SCIENCE↗

An Innovative Accident Tolerant LWR Fuel Rod Design Based on Uranium-Molybdenum Metal Alloy

The US Department of Energy is developing a uranium-molybdenum metal alloy Enhanced Accident Tolerant Fuel concept for Light Water Reactor applications that provides improved fuel performance during normal operation, anticipated operational occurrences, and postulated accidents. The high initial uranium atom density, the high thermal conductivity, and a low heat capacity permit a U-Mo-based fuel assembly to meet important design and safety requirements. These attributes also result in a fuel design that can satisfy increased fuel utilization demands and allow for improved accident tolerance in LWRs. This paper summarizes the results obtained from the on-going activities to; 1) evaluate the impact of the U-10wt%Mo thermal properties on operational and accident safety margins, 2) produce a triple extrusion of stainless steel cladding/niobium liner/U-10Mo fuel rod specimen and 3) test the high temperature water corrosion of rodlet samples containing a drilled hole in the cladding. Characterization of the cladding and liner thickness uniformity, microstructural features of the U-Mo gamma phase, and the metallurgical bond between the component materials will be presented. The results from corrosion testing will be discussed which yield insights into the resistance to attack by water ingress during high temperature water exposure for the triple extruded samples containing a drilled hole. These preliminary evaluations find that the U-10Mo fuel design concept has many beneficial features that can meet or improve conventional LWR fuel performance requirements under normal operation, AOOs, and postulated accidents. The viability of a deployable U-Mo fuel design hinges on demonstrating that fabrication processes and alloying additions can produce acceptable irradiation stability during normal operation and accident conditions and controlled metal-water reaction rates in the unlikely event of a cladding perforation. In the area of enhanced accident tolerance, a key objective is to establish that the lower stored energy of the U-Mo fuel design can provide the emergency core cooling systems the opportunity to maintain the reactor core in a coolable geometry following an accident.

Accident tolerance fuel↗

Isotope Enrichment Detection by Laser Ablation - Dual Tunable Diode Laser Absorption Spectrometry

The rapid global expansion of nuclear energy is motivating the expedited development of new safeguards technology to mitigate potential proliferation threats arising from monitoring gaps within the uranium enrichment process. Current onsite enrichment level monitoring methods are limited by poor sensitivity and accuracy performance. Offsite analysis has better performance, but this approach requires onsite hand sampling followed by time-consuming and costly post analysis. These limitations make it extremely difficult to implement comprehensive safeguards accounting measures that can effectively counter enrichment facility misuse. In addition, uranium enrichment by modern centrifugation leads to a significant proliferation threat, since the centrifuge cascades can quickly produce a significant quantity of highly enriched uranium (HEU). The Pacific Northwest National Laboratory is developing an engineered safeguards approach having continuous aerosol particulate collection and uranium isotope analysis to provide timely detection of HEU production in a low enriched uranium facility. This approach is based on laser vaporization of aerosol particulate samples, followed by wavelength tuned laser diode spectroscopy, to characterize the 235U/238U isotopic ratio by subtle differences in atomic absorption wavelengths arising from differences in each isotope’s nuclear mass, volume, and spin (hyperfine structure for 235U). Environmental sampling media is introduced into a small, reduced pressure chamber, where a focused pulsed laser vaporizes a 10 to 20-µm sample diameter. The ejected plasma forms a plume of atomic vapor. A plume for a sample containing uranium has atoms of the 235U and 238U isotopes present. Tunable diode lasers are directed through the plume to selectively excite each isotope and their presence is detected by monitoring absorbance signals on a shot-to-shot basis. Single-shot detection sensitivity approaching the femtogram range and abundance uncertainty less than 10% have been demonstrated with measurements on surrogate materials. In this paper we present measurement results on samples containing background materials (e.g., dust, minerals, soils) laced with micron-sized target particles having isotopic ratios ranging from 1 to 50%.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In-House Alternative for Chemical Analyses of Rhenium and Sulfur in Glass

Accurate measurements of rhenium (Re) and sulfur (S) concentrations in solid samples are of critical importance for the key research activities at the Pacific Northwest National Laboratory (PNNL) Waste Form Development Laboratory (WFDL) related to Re behavior during waste glass melting process and solubility of S in glass. Southwest Research Institute (SwRI) has provided reliable services for chemical analysis needs at WFDL; however, its long turnaround time, occasionally up to 5 months, has caused some difficulties. An in-house method was developed for dissolving and fusing glass and feed samples in preparation for analyses by inductively coupled plasma-optical emission spectrometry and -mass spectrometry at a PNNL facility. Using a previously developed sodium hydroxide fusion method as a basis, four groups of samples from Hanford waste glass research were digested and fused at WFDL. The samples included 1) Enhanced low-activity waste glass correlation phase 2/3 melter glasses from the Vitreous State Laboratory at the Catholic University of America, 2) AN-102 dried feeds and glasses, 3) SS-AN-102 dried feeds and glasses, and 4) Integrated Research Project S solubility study glasses. We evaluated three different sets of solution preparation and analysis combinations, which included 1) a WFDL-prepared solution analyzed at SwRI, 2) a PNNLprepared solution analyzed at a laboratory in the Building-331at PNNL, and 3) an SwRIprepared solution analyzed at SwRI. We concluded that the PNNL in-house Re results can be used in parallel with the SwRI data based on the relative standard deviation values less than 6% from three different sets of solution preparation and analysis for all three groups of rhenium-containing samples tested. However, it was proposed that the in-house S data be used for the barium oxide-free glasses only because of the issue of barium sulfate precipitation in digestion/fusion solutions prepared from glasses containing barium oxide. In addition, higher analytical biases between the PNNL and SwRI S results are expected compared to the Re results, based on the relative standard deviation values of less than 10% from three different sets of solution preparation and analysis for two groups of S-containing samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Overview of the Mars Sample Return Earth Entry Vehicle

NASA's Mars Sample Return (MSR) project will bring Mars surface and atmosphere samples back to Earth for detailed examination. Langley Research Center's MSR Earth Entry Vehicle (EEV) is a core part of the mission, protecting the sample container during atmospheric entry, descent, and landing. Planetary protection requirements demand a higher reliability from the EEV than for any previous planetary entry vehicle. An overview of the EEV design and preliminary analysis is presented, with a follow-on discussion of recommended future design trade studies to be performed over the next several years in support of an MSR launch in 2018 or 2020. Planned topics include vehicle size for impact protection of a range of sample container sizes, outer mold line changes to achieve surface sterilization during re-entry, micrometeoroid protection, aerodynamic stability, thermal protection, and structural materials selection.

Dillman, Robert↗