Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONE ALGORITHMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Optimization-based scatter estimation using primary modulation for computed tomography

Purpose: Scatter reduces the image quality in computed tomography (CT), but scatter correction remains a challenge. A previously proposed primary modulation method simultaneously obtains the primary and scatter in a single scan. However, separating the scatter and primary in primary modulation is challenging because it is an underdetermined problem. In this study, an optimization-based scatter estimation (OSE) algorithm is proposed to estimate and correct scatter. Methods: In the concept of primary modulation, the primary is modulated, but the scatter remains smooth by inserting a modulator between the x-ray source and the object. In the proposed algorithm, an objective function is designed for separating the scatter and primary. Prior knowledge is incorporated in the optimization-based framework to improve the accuracy of the estimation: (1) the primary is always positive; (2) the primary is locally smooth and the scatter is smooth; (3) the location of penumbra can be determined; and (4) the scatter-contaminated data provide knowledge about which part is smooth. Results: The simulation study shows that the edge-preserving weighting in OSE improves the estimation accuracy near the object boundary. Simulation study also demonstrates that OSE outperforms the two existing primary modulation algorithms for most regions of interest in terms of the CT number accuracy and noise. The proposed method was tested on a clinical cone beam CT, demonstrating that OSE corrects the scatter even when the modulator is not accurately registered. Conclusions: The proposed OSE algorithm improves the robustness and accuracy in scatter estimation and correction. This method is promising for scatter correction of various kinds of x-ray imaging modalities, such as x-ray radiography, cone beam CT, and the fourth-generation CT.

60 APPLIED LIFE SCIENCES↗

Analytic reconstruction algorithms for triple-source CT with horizontal data truncation

Purpose: This paper explores a triple-source imaging method with horizontal data truncation to enlarge the field of view (FOV) for big objects. Methods: The study is conducted by using theoretical analysis, mathematical deduction, and numerical simulations. The proposed algorithms are implemented in c + + and MATLAB. While the basic platform is constructed in MATLAB, the computationally intensive segments are coded in c + +, which are linked via a MEX interface. Results: A triple-source circular scanning configuration with horizontal data truncation is developed, where three pairs of x-ray sources and detectors are unevenly distributed on the same circle to cover the whole imaging object. For this triple-source configuration, a fan-beam filtered backprojection-type algorithm is derived for truncated full-scan projections without data rebinning. The algorithm is also extended for horizontally truncated half-scan projections and cone-beam projections in a Feldkamp-type framework. Using their method, the FOV is enlarged twofold to threefold to scan bigger objects with high speed and quality. The numerical simulation results confirm the correctness and effectiveness of the developed algorithms. Conclusions: The triple-source scanning configuration with horizontal data truncation cannot only keep most of the advantages of a traditional multisource system but also cover a larger FOV for big imaging objects. In addition, because the filtering is shift-invariant, the proposed algorithms are very fast and easily parallelized on graphic processing units.

60 APPLIED LIFE SCIENCES↗

A compressible Navier-Stokes solver with two-equation and Reynolds stress turbulence closure models

This report outlines the development of a general purpose aerodynamic solver for compressible turbulent flows. Turbulent closure is achieved using either two equation or Reynolds stress transportation equations. The applicable equation set consists of Favre-averaged conservation equations for the mass, momentum and total energy, and transport equations for the turbulent stresses and turbulent dissipation rate. In order to develop a scheme with good shock capturing capabilities, good accuracy and general geometric capabilities, a multi-block cell centered finite volume approach is used. Viscous fluxes are discretized using a finite volume representation of a central difference operator and the source terms are treated as an integral over the control volume. The methodology is validated by testing the algorithm on both two and three dimensional flows. Both the two equation and Reynolds stress models are used on a two dimensional 10 degree compression ramp at Mach 3, and the two equation model is used on the three dimensional flow over a cone at angle of attack at Mach 3.5. With the development of this algorithm, it is now possible to compute complex, compressible high speed flow fields using both two equation and Reynolds stress turbulent closure models, with the capability of eventually evaluating their predictive performance.

Navier-Stoke solver↗

Physics‐based iterative reconstruction for dual‐source and flying focal spot computed tomography

Purpose For single‐source helical Computed Tomography (CT), both Filtered‐Back Projection (FBP) and statistical iterative reconstruction have been investigated. However, for dual‐source CT with flying focal spot (DS‐FFS CT), a statistical iterative reconstruction that accurately models the scanner geometry and acquisition physics remains unknown to researchers. Therefore, our purpose is to present a novel physics‐based iterative reconstruction method for DS‐FFS CT and assess its image quality. Methods Our algorithm uses precise physics models to reconstruct from the native cone‐beam geometry and interleaved dual‐source helical trajectory of a DS‐FFS CT. To do so, we construct a noise physics model to represent data acquisition noise and a prior image model to represent image noise and texture. In addition, we design forward system models to compute the locations of deflected focal spots, the dimension, and sensitivity of voxels and detector units, as well as the length of intersection between x‐rays and voxels. The forward system models further represent the coordinated movement between the dual sources by computing their x‐ray coverage gaps and overlaps at an arbitrary helical pitch. With the above models, we reconstruct images by an advanced Consensus Equilibrium (CE) numerical method to compute the maximum a posteriori estimate to a joint optimization problem that simultaneously fits all models. Results We compared our reconstruction with Siemens ADMIRE, which is the clinical standard hybrid iterative reconstruction (IR) method for DS‐FFS CT, in terms of spatial resolution, noise profile, and image artifacts through both phantoms and clinical scan datasets. Experiments show that our reconstruction has a higher spatial resolution, with a Task‐Based Modulation Transfer Function (MTF task ) consistently higher than the clinical standard hybrid IR. In addition, our reconstruction shows a reduced magnitude of image undersampling artifacts than the clinical standard. Conclusions By modeling a precise geometry and avoiding data rebinning or interpolation, our physics‐based reconstruction achieves a higher spatial resolution and fewer image artifacts with smaller magnitude than the clinical standard hybrid IR.

Wang, Xiao↗

A comparison of upwind schemes for computation of three-dimensional hypersonic real-gas flows

The method of Suresh and Liou (1992) is extended, and the resulting explicit noniterative upwind finite-volume algorithm is applied to the integration of 3D parabolized Navier-Stokes equations to model 3D hypersonic real-gas flowfields. The solver is second-order accurate in the marching direction and employs flux-limiters to make the algorithm second-order accurate, with total variation diminishing in the cross-flow direction. The algorithm is used to compute hypersonic flow over a yawed cone and over the Ames All-Body Hypersonic Vehicle. The solutions obtained agree well with other computational results and with experimental data.

Gerbsch, R. A.↗

Novel multimodality segmentation using level sets and Jensen-Rényi divergence

Purpose: Positron emission tomography (PET) is playing an increasing role in radiotherapy treatment planning. However, despite progress, robust algorithms for PET and multimodal image segmentation are still lacking, especially if the algorithm were extended to image-guided and adaptive radiotherapy (IGART). This work presents a novel multimodality segmentation algorithm using the Jensen-Rényi divergence (JRD) to evolve the geometric level set contour. The algorithm offers improved noise tolerance which is particularly applicable to segmentation of regions found in PET and cone-beam computed tomography. Methods: A steepest gradient ascent optimization method is used in conjunction with the JRD and a level set active contour to iteratively evolve a contour to partition an image based on statistical divergence of the intensity histograms. The algorithm is evaluated using PET scans of pharyngolaryngeal squamous cell carcinoma with the corresponding histological reference. The multimodality extension of the algorithm is evaluated using 22 PET/CT scans of patients with lung carcinoma and a physical phantom scanned under varying image quality conditions. Results: The average concordance index (CI) of the JRD segmentation of the PET images was 0.56 with an average classification error of 65%. The segmentation of the lung carcinoma images had a maximum diameter relative error of 63%, 19.5%, and 14.8% when using CT, PET, and combined PET/CT images, respectively. The estimated maximal diameters of the gross tumor volume (GTV) showed a high correlation with the macroscopically determined maximal diameters, with aR{sup 2} value of 0.85 and 0.88 using the PET and PET/CT images, respectively. Results from the physical phantom show that the JRD is more robust to image noise compared to mutual information and region growing. Conclusions: The JRD has shown improved noise tolerance compared to mutual information for the purpose of PET image segmentation. Presented is a flexible framework for multimodal image segmentation that can incorporate a large number of inputs efficiently for IGART.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A digitally reconstructed radiograph algorithm calculated from first principles

Purpose: To develop an algorithm for computing realistic digitally reconstructed radiographs (DRRs) that match real cone-beam CT (CBCT) projections with no artificial adjustments. Methods: The authors used measured attenuation data from cone-beam CT projection radiographs of different materials to obtain a function to convert CT number to linear attenuation coefficient (LAC). The effects of scatter, beam hardening, and veiling glare were first removed from the attenuation data. Using this conversion function the authors calculated the line integral of LAC through a CT along rays connecting the radiation source and detector pixels with a ray-tracing algorithm, producing raw DRRs. The effects of scatter, beam hardening, and veiling glare were then included in the DRRs through postprocessing. Results: The authors compared actual CBCT projections to DRRs produced with all corrections (scatter, beam hardening, and veiling glare) and to uncorrected DRRs. Algorithm accuracy was assessed through visual comparison of projections and DRRs, pixel intensity comparisons, intensity histogram comparisons, and correlation plots of DRR-to-projection pixel intensities. In general, the fully corrected algorithm provided a small but nontrivial improvement in accuracy over the uncorrected algorithm. The authors also investigated both measurement- and computation-based methods for determining the beam hardening correction, and found the computation-based method to be superior, as it accounted for nonuniform bowtie filter thickness. The authors benchmarked the algorithm for speed and found that it produced DRRs in about 0.35 s for full detector and CT resolution at a ray step-size of 0.5 mm. Conclusions: The authors have demonstrated a DRR algorithm calculated from first principles that accounts for scatter, beam hardening, and veiling glare in order to produce accurate DRRs. The algorithm is computationally efficient, making it a good candidate for iterative CT reconstruction techniques that require a data fidelity term based on the matching of DRRs and projections.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Beam hardening correction using iterative total variation (ITV)-based algorithm in CBCT reconstruction

Recently, beam hardening reduction is required to produce high-quality reconstructions of X-ray cone-beam computed tomography (CBCT) system for medical applications. This paper introduces the iterative total variation (ITV) for filtered-backprojection suffering from the serious beam hardening problems. Feldkamp, Davis, and Kress (FDK) reconstruction algorithm for CBCT system is widely used reconstruction technique. FDK reconstruction algorithm could be realized by generating the weighted projection data, filtering the projection images, and back-projecting the filtered projection data into the volume. However, FDK algorithm suffers from the beam hardening artifacts by X-ray attenuation coefficients. Recently, total variation (TV) method for compressed sensing (CS) has been particularly useful in exploiting the prior knowledge of minimal variation in the X-ray attenuation characteristics across object or human body. But a practical implementation of this method still remains a challenge. The main problem is the iterative nature of solving the TV-based CS formulation, which generally requires multiple iterations of forward and backward projections of a large dataset in clinically or industrially feasible time frame. In this paper, we propose ITV method after FDK reconstruction for reducing the beam hardening artifacts. The beam hardening problems are reduced by the ITV method to promote sparsity inherent in the X-ray attenuation characteristics. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hierarchical Trigger of the ALICE Calorimeters

The trigger of the ALICE electromagnetic calorimeters is implemented in 2 hierarchically connected layers of electronics. In the lower layer, level-0 algorithms search shower energy above threshold in locally confined Trigger Region Units (TRU). The top layer is implemented as a single, global trigger unit that receives the trigger data from all TRUs as input to the level-1 algorithm. This architecture was first developed for the PHOS high p{sub T} photon trigger before it was adopted by EMCal also for the jet trigger. TRU units digitize up to 112 analogue input signals from the Front End Electronics (FEE) and concentrate their digital stream in a single FPGA. A charge and time summing algorithm is combined with a peakfinder that suppresses spurious noise and is precise to single LHC bunches. With a peak-to-peak noise level of 150 MeV the linear dynamic range above threshold spans from MIP energies at 215 up to 50 GeV. Local level-0 decisions take less than 600 ns after LHC collisions, upon which all TRUs transfer their level-0 trigger data to the upstream global trigger module which searches within the remaining level-1 latency for high p{sub T} gamma showers (PHOS) and/or for Jet cone areas (EMCaL).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cone-Probe Rake Design and Calibration for Supersonic Wind Tunnel Models

A series of experimental investigations were conducted at the NASA Langley Unitary Plan Wind Tunnel (UPWT) to calibrate cone-probe rakes designed to measure the flow field on 1-2% scale, high-speed wind tunnel models from Mach 2.15 to 2.4. The rakes were developed from a previous design that exhibited unfavorable measurement characteristics caused by a high probe spatial density and flow blockage from the rake body. Calibration parameters included Mach number, total pressure recovery, and flow angularity. Reference conditions were determined from a localized UPWT test section flow survey using a 10deg supersonic wedge probe. Test section Mach number and total pressure were determined using a novel iterative technique that accounted for boundary layer effects on the wedge surface. Cone-probe measurements were correlated to the surveyed flow conditions using analytical functions and recursive algorithms that resolved Mach number, pressure recovery, and flow angle to within +/-0.01, +/-1% and +/-0.1deg , respectively, for angles of attack and sideslip between +/-8deg. Uncertainty estimates indicated the overall cone-probe calibration accuracy was strongly influenced by the propagation of measurement error into the calculated results.

Won, Mark J.↗

Large-scale parallel multibody dynamics with frictional contact on the GPU.

In the context of simulating the frictional contact dynamics of large systems of rigid bodies, this paper reviews a novel method for solving large cone complementarity problems by means of a fixed-point iteration algorithm. The method is an extension of the Gauss-Seidel and Gauss-Jacobi methods with over-relaxation for symmetric convex linear complementarity problems. Convergent under fairly standard assumptions, the method is implemented in a parallel framework by using a single instruction multiple data computation paradigm promoted by the Compute Unified Device Architecture library for graphical processing unit programming. The framework supports the simulation of problems with more than one million bodies in contact. Simulation thus becomes a viable tool for investigating the dynamics of complex systems such as ground vehicles running on sand, powder composites, and granular material flow.

99 GENERAL AND MISCELLANEOUS↗

SU-E-J-151: Dosimetric Evaluation of DIR Mapped Contours for Image Guided Adaptive Radiotherapy with 4D Cone-Beam CT

Purpose: To estimate dosimetric errors resulting from using contours deformably mapped from planning CT to 4D cone beam CT (CBCT) images for image-guided adaptive radiotherapy of locally advanced non-small cell lung cancer (NSCLC). Methods: Ten locally advanced non-small cell lung cancer (NSCLC) patients underwent one planning 4D fan-beam CT (4DFBCT) and weekly 4DCBCT scans. Multiple physicians delineated the gross tumor volume (GTV) and normal structures in planning CT images and only GTV in CBCT images. Manual contours were mapped from planning CT to CBCTs using small deformation, inverse consistent linear elastic (SICLE) algorithm for two scans in each patient. Two physicians reviewed and rated the DIR-mapped (auto) and manual GTV contours as clinically acceptable (CA), clinically acceptable after minor modification (CAMM) and unacceptable (CU). Mapped normal structures were visually inspected and corrected if necessary, and used to override tissue density for dose calculation. CTV (6mm expansion of GTV) and PTV (5mm expansion of CTV) were created. VMAT plans were generated using the DIR-mapped contours to deliver 66 Gy in 33 fractions with 95% and 100% coverage (V66) to PTV and CTV, respectively. Plan evaluation for V66 was based on manual PTV and CTV contours. Results: Mean PTV V66 was 84% (range 75% – 95%) and mean CTV V66 was 97% (range 93% – 100%) for CAMM scored plans (12 plans); and was 90% (range 80% – 95%) and 99% (range 95% – 100%) for CA scored plans (7 plans). The difference in V66 between CAMM and CA was significant for PTV (p = 0.03) and approached significance for CTV (p = 0.07). Conclusion: The quality of DIR-mapped contours directly impacted the plan quality for 4DCBCT-based adaptation. Larger safety margins may be needed when planning with auto contours for IGART with 4DCBCT images. Reseach was supported by NIH P01CA116602.

60 APPLIED LIFE SCIENCES↗

A Sequential Quadratically Constrained Quadratic Programming Method of Feasible Directions

In this paper, a sequential quadratically constrained quadratic programming method of feasible directions is proposed for the optimization problems with nonlinear inequality constraints. At each iteration of the proposed algorithm, a feasible direction of descent is obtained by solving only one subproblem which consist of a convex quadratic objective function and simple quadratic inequality constraints without the second derivatives of the functions of the discussed problems, and such a subproblem can be formulated as a second-order cone programming which can be solved by interior point methods. To overcome the Maratos effect, an efficient higher-order correction direction is obtained by only one explicit computation formula. The algorithm is proved to be globally convergent and superlinearly convergent under some mild conditions without the strict complementarity. Finally, some preliminary numerical results are reported.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

WE-G-18A-03: Cone Artifacts Correction in Iterative Cone Beam CT Reconstruction

Purpose: For iterative reconstruction (IR) in cone-beam CT (CBCT) imaging, data truncation along the superior-inferior (SI) direction causes severe cone artifacts in the reconstructed CBCT volume images. Not only does it reduce the effective SI coverage of the reconstructed volume, it also hinders the IR algorithm convergence. This is particular a problem for regularization based IR, where smoothing type regularization operations tend to propagate the artifacts to a large area. It is our purpose to develop a practical cone artifacts correction solution. Methods: We found it is the missing data residing in the truncated cone area that leads to inconsistency between the calculated forward projections and measured projections. We overcome this problem by using FDK type reconstruction to estimate the missing data and design weighting factors to compensate the inconsistency caused by the missing data. We validate the proposed methods in our multi-GPU low-dose CBCT reconstruction system on multiple patients' datasets. Results: Compared to the FDK reconstruction with full datasets, while IR is able to reconstruct CBCT images using a subset of projection data, the severe cone artifacts degrade overall image quality. For head-neck case under a full-fan mode, 13 out of 80 slices are contaminated. It is even more severe in pelvis case under half-fan mode, where 36 out of 80 slices are affected, leading to inferior soft-tissue delineation. By applying the proposed method, the cone artifacts are effectively corrected, with a mean intensity difference decreased from ∼497 HU to ∼39HU for those contaminated slices. Conclusion: A practical and effective solution for cone artifacts correction is proposed and validated in CBCT IR algorithm. This study is supported in part by NIH (1R01CA154747-01)

60 APPLIED LIFE SCIENCES↗

Exploring small-angle emissions in charm quark jets in proton-proton collisions at $\sqrt{s}=5.02$ TeV

A measurement of the angular structure of inclusive jets and those containing a prompt D 0 meson in proton-proton collisions at the LHC at a center-of-mass energy of 5.02 TeV is presented. The data corresponding to an integrated luminosity of 301 pb −1 were collected by the CMS experiment in 2017. Two jet grooming algorithms, late-k T and soft drop, are used to study the intrajet radiation pattern using iterative Cambridge-Aachen declustering. The splitting-angle distributions of jets with transverse momentum (p T ) of around 100 GeV, obtained with these two algorithms, show that there is a shift of the distribution for jets containing a prompt D 0 meson with respect to inclusive jets. The suppression of emissions at small angles observed in the late-k T grooming approach is consistent with the dead-cone effect, whereas the similar suppression for splittings selected with the soft-drop algorithm appears to be induced by gluon splitting to charm quark-antiquark pairs at large angles. The measured distributions are corrected to the particle level and can be used to constrain model predictions for the substructure of high-p T charm quark jets.

Charm Physics↗

AbacusSummit Halo Light Cone Catalogs

This is a set of halo light cone catalogs from the AbacusSummit suite of cosmological N-body simulations (abacussummit.readthedocs.io/). They are a value-added data product provided by post-processing the simulation output. The main application of the halo light cone catalogs is the construction of realistic mock galaxy catalogues and weak lensing maps on the sky. The algorithm (described in Hadzhiyska et al. 2021) associates CompaSO halos from 29 redshift epochs spanning z = 0.1-2.5 with their particles at the time of light-cone crossing. It then records the halo and particle information into an easily accessible product, which can be read with the CompaSO reader. The 25 base resolution boxes at fiducial cosmology have a halo light cone catalog covering an octant of the sky to z approx 0.8 and about 2000 deg2 extending to z approx 2.4. The huge boxes provide light cone information of the full sky until z approx 2.18 and extend further towards the corners of the box (available until z = 2.25). Galaxy mock catalogs on the sky can be generated easily though the AbacusHOD script providing an extended HOD framework (see Yuan et al. 2021, for details), which has been modified to work with the halo light cone catalogs. The available tracers are luminous red galaxies (LRGs), emission-line galaxies (ELGs), and quasi-stellar objects (QSOs).

79 ASTRONOMY AND ASTROPHYSICS↗

Three-dimensional compressible laminar boundary layers on sharp and blunt circular cones at angle of attack

A method for solving the three-dimensional compressible laminar boundary layer equations for the case of a circular cone and a sphere-cone body at an angle of attack is presented. The governing equations are modified by a similarity type transformation and then transformed into a Crocco-type form. The resulting set of equations is solved simultaneously by an iterative method using an implicit finite difference scheme by means of an efficient algorithm for equations of tridiagonal form. The effects of streamline swallowing on a sharp cone are included by introducing the true inviscid edge conditions at the distance from the wall equal to the boundary layer thickness. The validity of the approach was established by comparison of the computational results with similar results by other methods and with experimental data. It was concluded that at sufficiently high Mach number and moderate to large angles of attack, the streamline swallowing effects on a sharp cone result in higher values of skin friction and heat transfer as compared with the classical results for constant entropy.

Popinski, Z.↗

Hierarchical Distributed Optimal Power Flow of HV and MV Distribution Networks With Continuous and Discrete Devices

With large-scale distributed photovoltaics (PVs) being integrated into distribution networks (DNs), coordinated optimal power flow (OPF) of high voltage (HV) and medium voltage (MV) DNs should be investigated to optimally dispatch the distributed PVs and other network devices. Here, this paper presents a hierarchical distributed OPF method for HV and MV DNs with on-load tap changers, reactive power compensators, feeder switches and distributed PVs. A hierarchical master-slave control architecture is applied to implement coordinated OPF of two-layer DNs. The HV master problem and MV subproblems are transformed into mixed-integer convex problems respectively with second order cone programming and LinDistFlow approximation. Since there is no efficient distributed algorithm to solve such OPF models with integer subproblems, a novel distributed algorithm is proposed in this paper to efficiently solve the hierarchical coordinated OPF model with integer subproblems in a distributed manner. In the proposed algorithm, the coordinated OPF model is solved in a branch-and-bound framework, where in each branch node generalized Benders decomposition (GBD) algorithm is applied to decompose the coordinated OPF model into a master problem and relaxed subproblems and solves them iteratively to get optimal solution. The GBD optimal and feasible cutting planes generated in a branch node are proved to be valid for its descendants. Moreover, three acceleration techniques are introduced into the proposed algorithm to improve computational efficiency. Finally, the effectiveness and accuracy of the proposed method are verified via simulation tests in Jinzhai DNs of China.

42 ENGINEERING↗