Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Dirac cones in the spectrum of bond-decorated graphenes

We present a two-band model based on periodic Hückel theory, which is capable of predicting the existence and position of Dirac cones in the first Brillouin zone of an infinite class of two-dimensional periodic carbon networks, obtained by systematic perturbation of the graphene connectivity by bond decoration, that is by inclusion of arbitrary π-electron Hückel networks into each of the three carbon–carbon π-bonds within the graphene unit cell. The bond decoration process can fundamentally modify the graphene unit cell and honeycomb connectivity, representing a simple and general way to describe many cases of graphene chemical functionalization of experimental interest, such as graphyne, janusgraphenes, and chlorographenes. Exact mathematical conditions for the presence of Dirac cones in the spectrum of the resulting two-dimensional π-networks are formulated in terms of the spectral properties of the decorating graphs. Our method predicts the existence of Dirac cones in experimentally characterized janusgraphenes and chlorographenes, recently speculated on the basis of density functional theory calculations. For these cases, our approach provides a proof of the existence of Dirac cones, and can be carried out at the cost of a back of the envelope calculation, bypassing any diagonalization step, even within Hückel theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced electron acceleration by high-intensity lasers in extended (confined) preplasma in cone targets

Here we report on experimental results from a high-intensity laser interaction with cone targets that increase the number (×3) and temperature (×3) of the measured hot electrons over a traditional planar target. This increase is caused by a substantial increase in the plasma density within the cone target geometry, which was induced by 17 ± 9 mJ prepulse that arrived 1.5 ns prior to the main high intensity (>10 19 W/cm 2 ). Three-dimensional hydrodynamic simulations are conducted using hydra which show that the cone targets create substantially longer and denser plasma than planar targets due to the geometric confinement of the expanding plasma. The density within the cone is a several hundred-micron plasma “shelf” with a density of approximately 10 20 n e /cc. The HYDRA simulated plasma densities are used as the initial conditions for two-dimensional particle-in-cell simulations using EPOCH. These simulations show that the main acceleration mechanism is direct-laser-acceleration, with close agreement between experimentally measured and simulated electron temperatures. Further analysis is conducted to investigate the acceleration of the electrons within the long plasma generated within a compound parabolic concentrator by the prepulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resonance cones in cold plasma: Origin, singularities, and power flow

In magnetized tenuous plasma, typical at the plasma edge of fusion devices, a nearly electrostatic wave mode with relatively enhanced electric field can propagate along a specific angle with the magnetic field. For this characteristic, it is known as a “resonance cone.” For instance, these waves can be excited by radio frequency antennas in the ion-cyclotron and lower-hybrid range of frequencies. We consider the resonance cones emitted by idealized spatially extended sources. In 2D, we use a novel geometric construction which generalizes the d'Alembert solution to curved boundaries/moving sources, and show, for the first time, that singular electric fields arise under these conditions, thereby bringing the resonance cones in line with the other resonances of the cold plasma theory. Still in 2D, we give an expression for the amount of power radiated by resonance cones in terms of surface quantities on the source, which is finite despite the singular electric field. In conclusion, we generalize the conclusions regarding the presence and location of singular electric fields to the 3D electromagnetic case.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Structural and functional dynamics of human cone cGMP-phosphodiesterase important for photopic vision

Cone cGMP-phosphodiesterase (PDE6) is the key effector enzyme for daylight vision, and its properties are critical for shaping distinct physiology of cone photoreceptors. We determined the structures of human cone PDE6C in various liganded states by single-particle cryo-EM that reveal essential functional dynamics and adaptations of the enzyme. Our analysis exposed the dynamic nature of PDE6C association with its regulatory γ-subunit (Pγ) which allows openings of the catalytic pocket in the absence of phototransduction signaling, thereby controlling photoreceptor noise and sensitivity. We demonstrate evolutionarily recent adaptations of PDE6C stemming from residue substitutions in the Pγ subunit and the noncatalytic cGMP binding site and influencing the Pγ dynamics in holoPDE6C. Thus, our structural analysis sheds light on the previously unrecognized molecular evolution of the effector enzyme in cones that advances adaptation for photopic vision.

Science & Technology - Other Topics↗

The halo light-cone catalogues of ABACUSSUMMIT

We describe a method for generating halo catalogues on the light-cone using the AbacusSummit suite of N-body simulations. The main application of these catalogues is the construction of realistic mock galaxy catalogues and weak lensing maps on the sky. Our algorithm associates the haloes from a set of coarsely spaced snapshots with their positions at the time of light-cone crossing by matching halo particles to on-the-fly light-cone particles. It then records the halo and particle information into an easily accessible product, which we call the AbacusSummit halo light-cone catalogues. Our recommended use of this product is in the halo mass regime of M halo > 2.1 x 10 11 M ⊙ h -1 for the base resolution simulations, i.e. haloes containing at least 100 particles, where the interpolated halo properties are most reliable. To test the validity of the obtained catalogues, we perform various visual inspections and consistency checks. In particular, we construct galaxy mock catalogues of emission-line galaxies (ELGs) at z ~ 1 by adopting a modified version of the AbacusHOD script, which builds on the standard halo occupation distribution (HOD) method by including various extensions. We find that the multipoles of the autocorrelation function are consistent with the predictions from the full-box snapshot, implicitly validating our algorithm. In addition, we compute and output CMB convergence maps and find that the auto- and cross-power spectrum agrees with the theoretical prediction at the sub-per-cent level.

79 ASTRONOMY AND ASTROPHYSICS↗

Observation of anisotropic Dirac cones in the topological material Ti 2 Te 2 P

Anisotropic bulk Dirac (or Weyl) cones in three-dimensional systems have recently gained intense research interest as they are examples of materials with tilted Dirac (or Weyl) cones indicating the violation of Lorentz invariance. In contrast, the studies on anisotropic surface Dirac cones in topological materials which contribute to anisotropic carrier mobility have been limited. By employing angle-resolved photoemission spectroscopy and first-principles calculations, we reveal the anisotropic surface Dirac dispersion in a tetradymite material Ti 2 Te 2 P on the (001) plane of the Brillouin zone. We observe quasielliptical Fermi pockets at the M ¯ point of the Brillouin zone forming the anisotropic surface Dirac cones. Our calculations of the Z 2 indices confirm that the system is topologically nontrivial with multiple topological phases in the same material. In addition, the observed nodal-line-like feature formed by bulk bands makes this system topologically rich.

36 MATERIALS SCIENCE↗

Measurement of breast tissue composition with dual energy cone-beam computed tomography: A postmortem study

Purpose: To investigate the feasibility of a three-material compositional measurement of water, lipid, and protein content of breast tissue with dual kVp cone-beam computed tomography (CT) for diagnostic purposes. Methods: Simulations were performed on a flat panel-based computed tomography system with a dual kVp technique in order to guide the selection of experimental acquisition parameters. The expected errors induced by using the proposed calibration materials were also estimated by simulation. Twenty pairs of postmortem breast samples were imaged with a flat-panel based dual kVp cone-beam CT system, followed by image-based material decomposition using calibration data obtained from a three-material phantom consisting of water, vegetable oil, and polyoxymethylene plastic. The tissue samples were then chemically decomposed into their respective water, lipid, and protein contents after imaging to allow direct comparison with data from dual energy decomposition. Results: Guided by results from simulation, the beam energies for the dual kVp cone-beam CT system were selected to be 50 and 120 kVp with the mean glandular dose divided equally between each exposure. The simulation also suggested that the use of polyoxymethylene as the calibration material for the measurement of pure protein may introduce an error of -11.0%. However, the tissue decomposition experiments, which employed a calibration phantom made out of water, oil, and polyoxymethylene, exhibited strong correlation with data from the chemical analysis. The average root-mean-square percentage error for water, lipid, and protein contents was 3.58% as compared with chemical analysis. Conclusions: The results of this study suggest that the water, lipid, and protein contents can be accurately measured using dual kVp cone-beam CT. The tissue compositional information may improve the sensitivity and specificity for breast cancer diagnosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-15: Quantitative Evaluation of Dose Distributions From Axial, Helical and Cone-Beam CT Imaging by Measurement Using a Two-Dimensional Diode-Array Detector

Purpose: To evaluate quantitatively dose distributions from helical, axial and cone-beam CT clinical imaging techniques by measurement using a two-dimensional (2D) diode-array detector. Methods: 2D-dose distributions from selected clinical protocols used for axial, helical and cone-beam CT imaging were measured using a diode-array detector (MapCheck2). The MapCheck2 is composed from solid state diode detectors that are arranged in horizontal and vertical lines with a spacing of 10 mm. A GE-Light-Speed CT-simulator was used to acquire axial and helical CT images and a kV on-board-imager integrated with a Varian TrueBeam-STx machine was used to acquire cone-beam CT (CBCT) images. Results: The dose distributions from axial, helical and cone-beam CT were non-uniform over the region-of-interest with strong spatial and angular dependence. In axial CT, a large dose gradient was measured that decreased from lateral sides to the middle of the phantom due to large superficial dose at the side of the phantom in comparison with larger beam attenuation at the center. The dose decreased at the superior and inferior regions in comparison to the center of the phantom in axial CT. An asymmetry was found between the right-left or superior-inferior sides of the phantom which possibly to angular dependence in the dose distributions. The dose level and distribution varied from one imaging technique into another. For the pelvis technique, axial CT deposited a mean dose of 3.67 cGy, helical CT deposited a mean dose of 1.59 cGy, and CBCT deposited a mean dose of 1.62 cGy. Conclusions: MapCheck2 provides a robust tool to measure directly 2D-dose distributions for CT imaging with high spatial resolution detectors in comparison with ionization chamber that provides a single point measurement or an average dose to the phantom. The dose distributions measured with MapCheck2 consider medium heterogeneity and can represent specific patient dose.

60 APPLIED LIFE SCIENCES↗

SU-E-T-757: TMRs Calculated From PDDs Versus the Direct Measurements for Small Field SRS Cones

Purpose: To investigate the variation of TMR for SRS cones obtained by TMR scanning, calculation from PDDs, and point measurements. The obtained TMRs were also compared to the representative data from the vendor. Methods: TMRs for conical cones of 4, 5, 7.5, 10, 12.5, 15, and 17.5 mm diameter (jaws set to 5×5 cm) were obtained for 6X FFF and 10X FFF energies on a Varian Edge linac. TMR scanning was performed with a Sun Nuclear 3D scanner and Edge detector at 100 cm SDD. TMR point measurements were measured with a Wellhofer tank and Edge detector, at multiple depths from 0.5 to 20 cm and 100 cm SDD. PDDs for converting to TMR were scanned with a Wellhofer system and SFD detector. The formalism of converting PDD to TMR, given in Khan’s book (4th Edition, p.161) was applied. Sp values at dmax were obtained by measuring Scp and Sc of the cones (jaws set to 5×5 cm) using the Edge detector, and normalized to the 10×10 cm field. Results: Along the central axis beyond dmax, the RMS and maximum percent difference of TMRs obtained with different methods were as follows: (a) 1.3% (max=3.5%) for the calculated TMRs from PDDs versus direct scanning; (b) 1.2% (max=3.3%) for direct scanning versus point measurement; (c) 1.8% (max=5.1%) for the calculated versus point measurements; (d) 1.0% (max=3.6%) for direct scanning versus vendor data; (e) 1.6% (max=7.2%) for the calculated versus vendor data. Conclusion: The overall accuracy of TMRs calculated from PDDs was comparable with that of direct scanning. However, the uncertainty at depths greater than 20 cm, increased up to 5% when compared to point measurements. This issue must be considered when developing a beam model for small field SRS planning using cones.

60 APPLIED LIFE SCIENCES↗

TU-CD-207-10: Dedicated Cone-Beam Breast CT: Design of a 3-D Beam-Shaping Filter

Purpose: To design a 3 -D beam-shaping filter for cone-beam breast CT for equalizing x-ray photon fluence incident on the detector along both fan and cone angle directions. Methods: The 3-D beam-shaping filter was designed as the sum of two filters: a bow-tie filter assuming cylindrical breast and a 3D difference filter equivalent to the difference in projected thickness between the cylinder and the real breast. Both filters were designed with breast-equivalent material and converted to Al for the targeted x-ray spectrum. The bow-tie was designed for the largest diameter cylindrical breast by determining the fan-angle dependent path-length and the filter thickness needed to equalize the fluence. A total of 23,760 projections (180 projections of 132 binary breast CT volumes) were averaged, scaled for the largest breast, and subtracted from the projection of the largest diameter cylindrical breast to provide the 3D difference filter. The 3 -D beam shaping filter was obtained by summing the two filters. Numerical simulations with semi-ellipsoidal breasts of 10–18 cm diameter (chest-wall to nipple length=0.75 x diameter) were conducted to evaluate beam equalization. Results: The proposed 3-D beam-shaping filter showed a 140% -300% improvement in equalizing the photon fluence along the chest-wall to nipple (cone-angle) direction compared to a bow-tie filter. The improvement over bow-tie filter was larger for breasts with longer chest-wall to nipple length. Along the radial (fan-angle) direction, the performance of the 3-D beam shaping filter was marginally better than the bow-tie filter, with 4%-10% improvement in equalizing the photon fluence. For a ray traversing the chest-wall diameter of the breast, the filter transmission ratio was >0.95. Conclusion: The 3-D beam shaping filter provided substantial advantage over bow-tie filter in equalizing the photon fluence along the cone-angle direction. In conjunction with a 2-axis positioner, the filter can accommodate breasts of varying dimensions and chest-wall inclusion. Supported in part by NIH R01 CA128906 and R21 CA134128. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or NCI.

60 APPLIED LIFE SCIENCES↗

Filtered-backprojection reconstruction for a cone-beam computed tomography scanner with independent source and detector rotations

Purpose: A new cone-beam CT scanner for image-guided radiotherapy (IGRT) can independently rotate the source and the detector along circular trajectories. Existing reconstruction algorithms are not suitable for this scanning geometry. The authors propose and evaluate a three-dimensional (3D) filtered-backprojection reconstruction for this situation. Methods: The source and the detector trajectories are tuned to image a field-of-view (FOV) that is offset with respect to the center-of-rotation. The new reconstruction formula is derived from the Feldkamp algorithm and results in a similar three-step algorithm: projection weighting, ramp filtering, and weighted backprojection. Simulations of a Shepp Logan digital phantom were used to evaluate the new algorithm with a 10 cm-offset FOV. A real cone-beam CT image with an 8.5 cm-offset FOV was also obtained from projections of an anthropomorphic head phantom. Results: The quality of the cone-beam CT images reconstructed using the new algorithm was similar to those using the Feldkamp algorithm which is used in conventional cone-beam CT. The real image of the head phantom exhibited comparable image quality to that of existing systems. Conclusions: The authors have proposed a 3D filtered-backprojection reconstruction for scanners with independent source and detector rotations that is practical and effective. This algorithm forms the basis for exploiting the scanner’s unique capabilities in IGRT protocols.

60 APPLIED LIFE SCIENCES↗

SU-F-J-51: A Cone-Based Scintillator Detector for IGRT QA for Scattered and Scanning Proton Therapy

Purpose: IGRT commissioning and QA are critical components for precise delivery of proton treatment beams to patients. In order to ensure high quality IGRT, a new cone-based scintillator detector was evaluated for our QA activities for double-scattered and scanning proton modalities. This allows a routine evaluation of the gantry-angle dependent position offset between the radiation and imaging. Methods: The cone-based scintillator detector (XRV-124, Logos Systems, Int’l CA, USA) features a unique configuration of measuring stereotactic paths of proton and x-ray beams in a single setup with arbitrary gantry angles. For the beams-eye-view (BEV) analysis of x-ray crosshair images, a cylindrical representation of the cone image was newly developed. The calibration accuracy was evaluated using different CT resolutions for a range of 55 – 95mm in patient’s cranial direction and ±9mm in the lateral direction. Energy-dependent spot sizes (σ) of pencil beams were characterized and compared to measurements by the MatriXX detector (IBA, Germany). Iso-centric deviations between radiation and x-ray imaging were characterized as a function of gantry angle. Results: The position calibration of the detector was successfully verified with a reproducible positioning by x-ray imaging. The measurements were reproducible within clinical tolerances (±1mm). The spot size vs. energy at zero gantry angle measured with the scintillating cone detector agreed with the MatriXX detector measurements within 17%. Conclusion: The new approach to investigate the accuracy of IGRT and pencil beam properties could successfully be implemented into the QA program. The system will improve efficiency in our QA activities for proton treatments.

60 APPLIED LIFE SCIENCES↗

The quantum entropy cone of hypergraphs

In this work, we generalize the graph-theoretic techniques used for the holographic entropy cone to study hypergraphs and their analogously-defined entropy cone. This allows us to develop a framework to efficiently compute entropies and prove inequalities satisfied by hypergraphs. In doing so, we discover a class of quantum entropy vectors which reach beyond those of holographic states and obey constraints intimately related to the ones obeyed by stabilizer states and linear ranks. We show that, at least up to 4 parties, the hypergraph cone is identical to the stabilizer entropy cone, thus demonstrating that the hypergraph framework is broadly applicable to the study of entanglement entropy. We conjecture that this equality continues to hold for higher party numbers and report on partial progress on this direction. To physically motivate this conjectured equivalence, we also propose a plausible method inspired by tensor networks to construct a quantum state from a given hypergraph such that their entropy vectors match.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of Nose Radius and Extreme Cooling on Boundary-Layer Transition for Three Smooth 15°-Cone-Cylinders in Free Flight at Mach Numbers to 8.50

Three highly polished 15°- included- angle cone- cylinders with hemispherical tips of several diameters ( 2, 3, and 4 in.) have been flown in order to obtain boundary- layer transition data at very low wall to local stream temperature ratios, and heat- transfer data. All surfaces had a 2-microinch average roughness height. Laminar flow existed over the entire hemispherical nose of the 2- and 3-inch-tip- diameter models throughout the complete flight history. Extreme cooling to wall to local stream temperature ratios at the sonic point as low as 0.20 did not cause transition on the nose for diameters as large as 3 inches. However, extreme cooling did cause early transition on the 4-inch model where it appears probable that transition occurred forward of the 45° station at a wall to local stream temperature ratio of about 0.26. Variations in tip diameter influenced transition downstream of the nose under conditions of extreme cooling. The 2-inch- tip model was laminar at all cone- cylinder stations at temperature ratios as low as 0.32 whereas the 3- and 4-inch-tip models were turbulent at the same local flow conditions but at higher wall to local temperature ratios. Transition on the cone and cylinder of the 3- and 4-inch- tip bodies appeared to be sensitive to local Mach number, and occurred at higher local temperature ratios when values of local Mach number were higher. Increasing the nose diameter from 2 to 3 inches significantly changed the local flow conditions for which laminar flow existed on the cone- cylinder afterbody. However, a further increase in tip size t o a 4-inch diameter had no discernable effect on the local flow conditions at transition. The transition results of the 3- and 4-inch-nose-diameter smooth bodies are similar to those observed on a 7/8-inch-nose-diameter body with roughened surfaces. Turbulent boundary layers resulted in both cases at very low wall to local stream temperature ratios. Both laminar and turbulent heat-transfer data were in good agreement with theoretical Stanton numbers when heat-transfer reduction due to tip blunting was considered.

CYLINDRICAL AFTERBODY↗

Cone and column solar energy concentrator

Solar energy concentrator consists of a reflective membrane cone and a stepped parabolic column located along the optical axis of the cone. The membrane cone can be folded for packaging and is supported by an expandable ring at the rim of the cone when erected. The stepped parabolic column can be telescoped for packaging.

Mc Cusker, T. J.↗

Static and dynamic pitching moment measurements on a family of elliptic cones at Mach number 11 in helium

Static and dynamic pitching moment measurements were made on a family of constant volume elliptic cones about two fixed axes of oscillation in the NAE helium hypersonic wind tunnel at a Mach number of 11 and at Reynolds numbers based on model length of up to 14 million. Viscous effects on the stability derivatives were investigated by varying the Reynolds number for certain models by a factor as large as 10. The models investigated comprised a 7.75 deg circular cone, elliptic cones of axis ratios 3 and 6, and an elliptic cone with conical protuberances.

Orlik-Rueckermann, K. J.↗

Computation of supersonic flow fields about bodies in coning motion using a shock-capturing finite-difference technique.

A numerical method for computing the nonlinear inviscid flow field surrounding a body performing coning motion is described. The method permits accurate computation of the aerodynamic moment due to one of the four motions characterizing an arbitrary nonplanar motion. Results of computations for a slender circular cone in coning motion are presented, and show good agreement with experiment for angles of attack up to twice the cone half angle. The computational results display significant departure of the side moment from the linear theory value with increasing angle of attack, but agree well with experimental measurements. This indicates that the initial nonlinear behavior of the aerodynamic moment is determined primarily by the inviscid flow.

Schiff, L. B.↗

Testing techniques and comparisons between theory and test for vibration modes of ring stiffened truncated-cone shells.

Vibration tests were carried out on truncated-cone shells with widely spaced ring stiffeners. The models were excited by an air shaker for LF modes and by small electrodynamic shakers for HF modes. The Novozhilov thin shell theory according to which a ring is an assembly of an arbitrary number of segments, each being a short truncated-cone shell of uniform thickness, is used in the analysis of the results. A mobile, noncontacting, displacement-sensitive sensor system developed by the author was used in the tests. Tests results are given for a free-free 60-deg cone and for a clamped-free 60-deg cone. The tests are characterized as having considerable value for the classification of prevalent multimode responses in shells of this type.

Naumann, E. C.↗