Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPUTER ANIMATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Stable Small Animal Mechanical Ventilation for Dynamic Lung Imaging to Support Computational Fluid Dynamics Models

Pulmonary computational fluid dynamics models require 3D images to be acquired over multiple points in the dynamic breathing cycle, with no breath holds or changes in ventilatory mechanics. With small animals, these requirements result in long imaging times ({approx}90 minutes), over which lung mechanics, such as compliance, can gradually change if not carefully monitored and controlled. These changes, caused by derecruitment of parenchymal tissue, are manifested as an upward drift in peak inspiratory pressure or by changes in the pressure waveform and/or lung volume over the course of the experiment. We demonstrate highly repeatable mechanical ventilation in anesthetized rats over a long duration for pulmonary CT imaging throughout the dynamic breathing cycle. We describe significant updates to a basic commercial ventilator that was acquired for these experiments. Key to achieving consistent results was the implementation of periodic deep breaths, or sighs, of extended duration to maintain lung recruitment. In addition, continuous monitoring of breath-to-breath pressure and volume waveforms and long-term trends in peak inspiratory pressure and flow provide diagnostics of changes in breathing mechanics.

59 BASIC BIOLOGICAL SCIENCES↗

Final Report for NMBSA Project, Monika Kaden, 2016

The following pages define the objectives and results for Project 022, requested by Monika Kaden, a sculptor who maintains studios in Santa Fe. This effort was first approved in February 2016, and was completed during several different time segments spread over the year, depending on Monika’s availability. The project deliverables that are of primary use to the customer are digital data files that are to be delivered electronically. This report is a summary overview of how the project was conducted.

97 MATHEMATICS AND COMPUTING↗

Introduction: Neuromorphic Materials

The explosive growth in data collection and the need to process it efficiently, as well as the desire to automate increasingly complex tasks in transportation, medical care, manufacturing, security and many other fields have motivated a growing interest in neuromorphic computing. Unlike the binary, transistorbased ON/OFF logic gates and separate logic and memory functionalities employed in digital computing, neuromorphic computing is inspired by animal brains that use interconnected synapses and neurons to perform processing, storage and transmission of information at the same location, while only consuming ~20 W or less of power. Motivated by the brain’s efficiency, adaptability, self-learning and resiliency qualities, neuromorphic computing can be broadly defined as an approach to processing and storing information using hardware and algorithms inspired by models of biological neural systems. Present research in neuromorphic computing encompasses approaches that vary significantly in their degree of neuro-inspiration, from systems that only incorporate features such as asynchronous, event-driven operation or use crossbar arrays of non-volatile memory (NVM) elements to accelerate deep neural networks (DNNs), to designs that embrace the extreme parallelism, sparsity, reconfigurability, adaptability, complexity and stochasticity observed in nervous systems. The term ‘neuromorphic’ computing is often credited to Carver Mead, who in the 1980s investigated Si-based analog electronics to replicate functions of the animal retina. Earlier important advances in this field include the work of Frank Rosenblatt, who proposed the concept of the perceptron, Bernard Widrow, who used this concept to build one of the first analog neural networks, the Adaline and many other researchers (see ref. 6 for an historical perspective on neuromorphic computing). With the recent increase in the use of artificial intelligence and large language models, and rising concerns over the associated energy costs, interest in neuromorphic hardware has expanded rapidly. According to some estimates, driven largely by the drastic growth in the training use of artificial intelligence (AI) models using the current computing architectures, the energy cost of computing is projected to reach the energy supply worldwide by 2045. Furthermore, while this is not a realistic outcome, it means that, if more efficient computing technologies are not developed -- soon -- the world will soon become one where demand for energy and market constraints limit the continued increase of societal access to AI and cloud services from data centers. Data centers used for training and use of these models consume hundreds of terawatt hours of electricity, already past 4% of the US electricity demand.

Circuits↗

Development of a prototype gantry system for preclinical x-ray phase-contrast computed tomography

Purpose: To explore the potential of grating-based x-ray phase-contrast imaging for clinical applications, a first compact gantry system was developed. It is designed such that it can be implemented into an in-vivo small-animal phase-contrast computed tomography (PC-CT) scanner. The purpose of the present study is to assess the accuracy and quantitativeness of the described gantry in both absorption and phase-contrast. Methods: A phantom, containing six chemically well-defined liquids, was constructed. A tomography scan with cone-beam reconstruction of this phantom was performed yielding the spatial distribution of the linear attenuation coefficient {mu} and decrement {delta} of the complex refractive index. Theoretical values of {mu} and {delta} were calculated for each liquid from tabulated data and compared with the experimentally measured values. Additionally, a color-fused image representation is proposed to display the complementary absorption and phase-contrast information in a single image. Results: Experimental and calculated data of the phantom agree well confirming the quantitativeness and accuracy of the reconstructed spatial distributions of {mu} and {delta}. The proposed color-fused image representation, which combines the complementary absorption and phase information, considerably helps in distinguishing the individual substances. Conclusions: The concept of grating-based phase-contrast computed tomography (CT) can be implemented into a compact, cone-beam geometry gantry setup. The authors believe that this work represents an important milestone in translating phase-contrast x-ray imaging from previous proof-of-principle experiments to first preclinical biomedical imaging applications on small-animal models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Generating Animated Displays of Spacecraft Orbits

Tool for Interactive Plotting, Sonification, and 3D Orbit Display (TIPSOD) is a computer program for generating interactive, animated, four-dimensional (space and time) displays of spacecraft orbits. TIPSOD utilizes the programming interface of the Satellite Situation Center Web (SSCWeb) services to communicate with the SSC logic and database by use of the open protocols of the Internet. TIPSOD is implemented in Java 3D and effects an extension of the preexisting SSCWeb two-dimensional static graphical displays of orbits. Orbits can be displayed in any or all of the following seven reference systems: true-of-date (an inertial system), J2000 (another inertial system), geographic, geomagnetic, geocentric solar ecliptic, geocentric solar magnetospheric, and solar magnetic. In addition to orbits, TIPSOD computes and displays Sibeck's magnetopause and Fairfield's bow-shock surfaces. TIPSOD can be used by the scientific community as a means of projection or interpretation. It also has potential as an educational tool.

Candey, Robert M.↗

Comet Impact 1994 Animation Reel

This video contains computer generated simulations of the impact of comet Shoemaker-Levy 9 with Jupiter that will take place in July 1994. The simulations display the event from a number of vantage points including earth view, views from orbit, and views from the surface of Jupiter's moons.

Source record↗

A simple electrical-mechanical model of the heart applied to the study of electrical-mechanical alternans

Recent evidence has shown that a subtle alternation in the surface ECG (electrical alternans) may be correlated with the susceptibility to ventricular fibrillation. In the present work, the author presents evidence that a mechanical alternation in the heartbeat (mechanical alternans) generally accompanies electrical alternans. A simple finite-element computer model which emulates both the electrical and the mechanical activity of the heart is presented. A pilot animal study is also reported. The computer model and the animal study both found that (1) there exists a regime of combined electrical-mechanical alternans during the transition from a normal rhythm towards a fibrillatory rhythm, (2) the detected degree of alternation is correlated with the relative instability of the rhythm, and (3) the electrical and mechanical alternans may result from a dispersion in local electrical properties leading to a spatial-temporal alternation in the electrical conduction process.

Clancy, Edward A.↗

Development of a Micro-Computed Tomography-Based Image-Guided Conformal Radiotherapy System for Small Animals

Purpose: To report on the physical aspects of a system in which radiotherapy functionality was added to a micro-computed tomography (microCT) scanner, to evaluate the accuracy of this instrument, and to and demonstrate the application of this technology for irradiating tumors growing within the lungs of mice. Methods and Materials: A GE eXplore RS120 microCT scanner was modified by the addition of a two-dimensional subject translation stage and a variable aperture collimator. Quality assurance protocols for these devices, including measurement of translation stage positioning accuracy, collimator aperture accuracy, and collimator alignment with the X-ray beam, were devised. Use of this system for image-guided radiotherapy was assessed by irradiation of a solid water phantom as well as of two mice bearing spontaneous MYC-induced lung tumors. Radiation damage was assessed ex vivo by immunohistochemical detection of {gamma}H2AX foci. Results: The positioning error of the translation stage was found to be <0.05 mm, whereas after alignment of the collimator with the X-ray axis through adjustment of its displacement and rotation, the collimator aperture error was <0.1 mm measured at isocenter. Computed tomography image-guided treatment of a solid water phantom demonstrated target localization accuracy to within 0.1 mm. Gamma-H2AX foci were detected within irradiated lung tumors in mice, with contralateral lung tissue displaying background staining. Conclusions: Addition of radiotherapy functionality to a microCT scanner is an effective means of introducing image-guided radiation treatments into the preclinical setting. This approach has been shown to facilitate small-animal conformal radiotherapy while leveraging existing technology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Collection Of Software For Computer Graphics

Ames Research Graphics System (ARCGRAPH) collection of software libraries and software utilities assisting researchers in generating, manipulating, and visualizing graphical data. Defines metafile format containing device-independent graphical data. File format used with various computer-graphics-manipulation and -animation software packages at Ames, including SURF (COSMIC Program ARC-12381) and GAS (COSMIC Program ARC-12379). Consists of two-stage "pipeline" used to put out graphical primitives. ARCGRAPH libraries developed on VAX computer running VMS.

Hibbard, Eric A.↗

Design of a specialized computer for on-line monitoring of cardiac stroke volume

The design of a specialized analog computer for on-line determination of cardiac stroke volume by means of a modified version of the pressure pulse contour method is presented. The design consists of an analog circuit for computation and a timing circuit for detecting necessary events on the pressure waveform. Readouts of arterial pressures, systolic duration, heart rate, percent change in stroke volume, and percent change in cardiac output are provided for monitoring cardiac patients. Laboratory results showed that computational accuracy was within 3 percent, while animal experiments verified the operational capability of the computer. Patient safety considerations are also discussed.

Webb, J. A., Jr.↗

Quo vadimus? The 21st Century and multimedia

The concept is related of computer driven multimedia to the NASA Scientific and Technical Information Program (STIP). Multimedia is defined here as computer integration and output of text, animation, audio, video, and graphics. Multimedia is the stage of computer based information that allows access to experience. The concepts are also drawn in of hypermedia, intermedia, interactive multimedia, hypertext, imaging, cyberspace, and virtual reality. Examples of these technology developments are given for NASA, private industry, and academia. Examples of concurrent technology developments and implementations are given to show how these technologies, along with multimedia, have put us at the threshold of the 21st century. The STI Program sees multimedia as an opportunity for revolutionizing the way STI is managed.

Kuhn, Allan D.↗

Theoretical and experimental studies of baroclinic processes

The geophysical fluid flow simulation code, GEOSIM, is being used to study the phenomenon of vacillation in the baroclinic annulus. Having verified that the code predicts vacillation for the same points as the experiments, the work is aiming toward explaining the mechanics of vacillation and pointing out some of the sensitivities of the results to the numerical method. Researchers are finding that there is a structural change associated with amplitude vacillation, where the structural changes are in the vertical. The results disagree with the premise of Lindzen et al, that the vacillation is due to constructive and destructive interference of neutral modes with different phase speeds. The researchers are continuing to study the Spacelab 3 Geophysical Fluid Flow Cell (GFFC) results with horizontal temperature gradients and heating from below. GEOSIM has been used to compute a wide range of cases, and these are being compared with the observations. The computations and observations compare well, and the model is being used to extend the results beyond cases studied in the experiments and to study the mechanics and predictability of the flows. The study of fully nonlinear baroclinic instability using the GFFC apparatus is proceeding with the numerical code. While the first instability that occurs is of planetary scale, secondary instabilities consisting of small-scale, penetrative convection occurs where cold fluid flows over a warm surface. The simultaneous modeling of the planetary scale and the convective scale is possible because of the nonhydrostatic formulation of the model. Some of these results have been animated on the Stardent computer, which shows the explosive nature of the small-scale convection.

Miller, Tim↗

Thermal Tracker: The Secret Lives of Bats and Birds Revealed

Offshore wind developers and stakeholders can accelerate the sustainable, widespread deployment of offshore wind using a new open-source software program, called ThermalTracker. Researchers can now collect the data they need to better understand the potential effects of offshore wind turbines on bird and bat populations. This plug and play software can be used with any standard desktop computer, thermal camera, and statistical software to identify species and behaviors of animals in offshore locations.

17 WIND ENERGY↗

SU-F-T-53: Treatment Planning with Inhomogeneity Correction for Intraoperative Radiotherapy Using KV X-Ray Beams

Purpose: The current standard in dose calculation for intraoperative radiotherapy (IORT) using the ZEISS Intrabeam 50 kV x-ray system is based on depth dose measurements in water and no heterogeneous tissue effect has been taken into account. We propose an algorithm for pre-treatment planning including inhomogeneity correction based on data of depth dose measurements in various tissue phantoms for kV x-rays. Methods: Direct depth dose measurements were made in air, water, inner bone and cortical bone phantoms for the Intrabeam 50 kV x-rays with a needle applicator. The data were modelled by a function of power law combining exponential with different parameters. Those phantom slabs used in the measurements were scanned to obtain CT numbers. The x-ray beam initiated from the source isocenter is ray-traced through tissues. The corresponding doses will be deposited/assigned at different depths. On the boundary of tissue/organ changes, the x-ray beam will be re-traced in new tissue/organ starting at an equivalent depth with the same dose. In principle, a volumetric dose distribution can be generated if enough directional beams are traced. In practice, a several typical rays traced may be adequate in providing estimates of maximum dose to the organ at risk and minimum dose in the target volume. Results: Depth dose measurements and modeling are shown in Figure 1. The dose versus CT number is shown in Figure 2. A computer program has been written for Kypho-IORT planning using those data. A direct measurement through 2 mm solid water, 2 mm inner bone, and 1 mm solid water yields a dose rate of 7.7 Gy/min. Our calculation shows 8.1±0.4 Gy/min, consistent with the measurement within 5%. Conclusion: The proposed method can be used to more accurately calculate the dose by taking into account the heterogeneous effect. The further validation includes comparison with Monte Carlo simulation.

60 APPLIED LIFE SCIENCES↗

Improved Depiction Of Computed Unsteady Flows

PLOT4D and STREAKER programs increase ease of production and utility of animated depictions of unsteady flows simulated numerically by advanced computational fluid dynamics. Programs developed to maximize information displayed while minimizing amount stored. PLOT4D, an extended version of PLOT3D, used to depict steady three-dimensional flows, incorporates features making it more computationally efficient than to visualize unsteady flow as succession of steady flows, animating frame by frame. PLOT4D postprocesses numerical output of fluid-dynamical computation into maps of flow quantities on two-coordinate surfaces depicting cut through flow field or conform to body surface. STREAKER generates streaklines, close approximations of patterns traced by streams of dye or smoke released into simulated flows. Streaklines defined via spatial succession of endpoints of pathlines of massless particles released into flow. STREAKER computes endpoints by fourth-order Runge-Kutta integration of velocity vectors.

Smith, Merritt H.↗

Environmental control and life support systems analysis for a Space Station life sciences animal experiment

NASA's Langley and Goddard facilities have evaluated the effects of animal science experiments on the Space Station's Environmental Control and Life Support System (ECLSS) by means of computer-aided analysis, assuming an animal colony consisting of 96 rodents and eight squirrel monkeys. Thirteen ECLSS options were established for the reclamation of metabolic oxygen and waste water. Minimum cost and weight impacts on the ECLSS are found to accrue to the system's operation in off-nominal mode, using electrochemical CO2 removal and a static feed electrolyzer for O2 generation.

So, Kenneth T.↗

Exploratory Study of 4D versus 3D Robust Optimization in Intensity Modulated Proton Therapy for Lung Cancer

Purpose: The purpose of this study was to compare the impact of uncertainties and interplay on 3-dimensional (3D) and 4D robustly optimized intensity modulated proton therapy (IMPT) plans for lung cancer in an exploratory methodology study. Methods and Materials: IMPT plans were created for 11 nonrandomly selected non-small cell lung cancer (NSCLC) cases: 3D robustly optimized plans on average CTs with internal gross tumor volume density overridden to irradiate internal target volume, and 4D robustly optimized plans on 4D computed tomography (CT) to irradiate clinical target volume (CTV). Regular fractionation (66 Gy [relative biological effectiveness; RBE] in 33 fractions) was considered. In 4D optimization, the CTV of individual phases received nonuniform doses to achieve a uniform cumulative dose. The root-mean-square dose-volume histograms (RVH) measured the sensitivity of the dose to uncertainties, and the areas under the RVH curve (AUCs) were used to evaluate plan robustness. Dose evaluation software modeled time-dependent spot delivery to incorporate interplay effect with randomized starting phases of each field per fraction. Dose-volume histogram (DVH) indices comparing CTV coverage, homogeneity, and normal tissue sparing were evaluated using Wilcoxon signed rank test. Results: 4D robust optimization plans led to smaller AUC for CTV (14.26 vs 18.61, respectively; P=.001), better CTV coverage (Gy [RBE]) (D{sub 95%} CTV: 60.6 vs 55.2, respectively; P=.001), and better CTV homogeneity (D{sub 5%}-D{sub 95%} CTV: 10.3 vs 17.7, resspectively; P=.002) in the face of uncertainties. With interplay effect considered, 4D robust optimization produced plans with better target coverage (D{sub 95%} CTV: 64.5 vs 63.8, respectively; P=.0068), comparable target homogeneity, and comparable normal tissue protection. The benefits from 4D robust optimization were most obvious for the 2 typical stage III lung cancer patients. Conclusions: Our exploratory methodology study showed that, compared to 3D robust optimization, 4D robust optimization produced significantly more robust and interplay-effect-resistant plans for targets with comparable dose distributions for normal tissues. A further study with a larger and more realistic patient population is warranted to generalize the conclusions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-18C-04: Evaluation of Effective Dose During Ureteroscopy for Obese and Non-Obese Patients

Purpose: Ureteroscopy involves fluoroscopy which potentially results in considerable amount of radiation dose to the patient. Purpose of this study was two-fold: (a) to develop the effective dose computational model for obese and non-obese patients undergoing left and right ureteroscopy, and (b) to evaluate the utility of a commercial Monte Carlo software for dose assessment in ureteroscopy. Methods: Organ dose measurements were performed on an adult male anthropomorphic phantom, representing the non-obese patients, with 20 high-sensitivity MOSFET detectors and two 0.18cc ionization chambers placed in selected organs. Fat-equivalent paddings were placed around the abdominal region to simulate for obese patients. Effective dose (ED) was calculated using ICRP 103 tissue weighting factors and normalized to the effective dose rate in miliSivert per second (mSv/s). In addition, a commercial Monte Carlo (MC) dose estimation program was used to estimate ED for the non-obese model, with table attenuation correction applied to simulate clinical procedure. Results: For the equipment and protocols involved in this study, the MOSFETderived ED rates for the obese patient model (‘Left’: 0.0092±0.0004 mSv/s; ‘Right’: 0.0086±0.0004 mSv/s) was found to be more than twice as much as that to the non-obese patient model (‘Left’: 0.0041±0.0003 mSv/s; ‘Right’: 0.0036±0.0007 mSv/s). The MC-derived ED rates for the non-obese patient model (‘Left’: 0.0041 mSv/s; ‘Right’: 0.0036 mSv/s; with statistical uncertainty of 1%) showed a good agreement with the MOSFET method. Conclusion: The significant difference in ED rate between the obese and non-obese patient models shows the limitation of directly applying commercial softwares for obese patients and leading to considerable underestimation of ED. Although commercial softwares offer a convenient means of dose estimation, but the utility may be limited to standard-man geometry as the software does not account for table attenuation, obese patient geometry, and differences between the anthropomorphic phantom and MC mathematical phantom.

60 APPLIED LIFE SCIENCES↗