Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPARISON SOFTWARE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Rapid sample classification using an open port sampling interface coupled with liquid introduction atmospheric pressure ionization mass spectrometry

An “Open Access”-like mass spectrometric platform to fully utilize the simplicity of the manual open port sampling interface for rapid characterization of unprocessed samples by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The in-house developed integrated software with a simple, small and relatively low-cost mass spectrometry system introduced here fills this void. Software was developed to operate the mass spectrometer, to collect and process mass spectrometric data files, to build a database and to classify samples using such a database. These tasks were accomplished via the vendorprovided software libraries. Sample classification based on spectral comparison utilized the spectral contrast angle method. As a result, using the developed software platform near real-time sample classification is exemplified using a series of commercially available blue ink rollerball pens and vegetable oils. In the case of the inks, full scan positive and negative ion ESI mass spectra were both used for database generation and sample classification. For the vegetable oils, full scan positive ion mode APCI mass spectra were recorded. The overall accuracy of the employed spectral contrast angle statistical model was 95.3% and 98% in case of the inks and oils, respectively, using leave-one-out cross-validation. In conclusion, this work illustrates that an open port sampling interface/mass spectrometer combination, with appropriate instrument control and data processing software, is a viable direct liquid extraction sampling and analysis system suitable for the non-expert user and near real-time sample classification via database matching.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Normalized Temperature Contrast Processing in Flash Infrared Thermography

The paper presents further development in normalized contrast processing of flash infrared thermography method by the author given in US 8,577,120 B1. The method of computing normalized image or pixel intensity contrast, and normalized temperature contrast are provided, including converting one from the other. Methods of assessing emissivity of the object, afterglow heat flux, reflection temperature change and temperature video imaging during flash thermography are provided. Temperature imaging and normalized temperature contrast imaging provide certain advantages over pixel intensity normalized contrast processing by reducing effect of reflected energy in images and measurements, providing better quantitative data. The subject matter for this paper mostly comes from US 9,066,028 B1 by the author. Examples of normalized image processing video images and normalized temperature processing video images are provided. Examples of surface temperature video images, surface temperature rise video images and simple contrast video images area also provided. Temperature video imaging in flash infrared thermography allows better comparison with flash thermography simulation using commercial software which provides temperature video as the output. Temperature imaging also allows easy comparison of surface temperature change to camera temperature sensitivity or noise equivalent temperature difference (NETD) to assess probability of detecting (POD) anomalies.

Koshti, Ajay M.↗

Cloud Computing Option for Modeling the Debris Environment

NASA’s Digital Transformation Initiative aims to promote the agency’s adoption of current and evolving digital technologies. Through agency-wide collaboration with other NASA teams, the Office of Safety and Mission Assurance (OSMA) has directed the Orbital Debris Program Office and the Meteoroid Environment Office to integrate cloud computing technologies in their publicly released software models: the Orbital Debris Engineering Model (ORDEM) and the Meteoroid Engineering Model (MEM). Decoupling the user interface from the backend processor was key for the software packages to run on a cloud computing framework. Benefits to this design include horizontal scaling of computing resources, user authentication and authorization, and automated deployment. Both models are hosted on a cloud computing platform supported by the NASA authorized IT security and compliance framework. This paper focuses on the new ORDEM web application, which includes the current features of the publicly released ORDEM software with an upgraded frontend design. The underlying ORDEM processor is run on a cloud container, allowing the user to run multiple spacecraft and telescope/radar mode simulations. Featuresexclusive to the ORDEM web application, such as importing multiple TLEs, auto-generated plotting, and the ability to check runtime progress are discussed. Comparisons between the current ORDEM software and the web application are summarized.

Andrew Vavrin↗

SU-E-T-133: Assessing IMRT Treatment Delivery Accuracy and Consistency On a Varian TrueBeam Using the SunNuclear PerFraction EPID Dosimetry Software

Purpose: To assess if the TrueBeam HD120 collimator is delivering small IMRT fields accurately and consistently throughout the course of treatment using the SunNuclear PerFraction software. Methods: 7-field IMRT plans for 8 canine patients who passed IMRT QA using SunNuclear Mapcheck DQA were selected for this study. The animals were setup using CBCT image guidance. The EPID fluence maps were captured for each treatment field and each treatment fraction, with the first fraction EPID data serving as the baseline for comparison. The Sun Nuclear PerFraction Software was used to compare the EPID data for subsequent fractions using a Gamma (3%/3mm) pass rate of 90%. To simulate requirements for SRS, the data was reanalyzed using a Gamma (3%/1mm) pass rate of 90%. Low-dose, low- and high gradient thresholds were used to focus the analysis on clinically relevant parts of the dose distribution. Results: Not all fractions could be analyzed, because during some of the treatment courses the DICOM tags in the EPID images intermittently change from CU to US (unspecified), which would indicate a temporary loss of EPID calibration. This technical issue is still being investigated. For the remaining fractions, the vast majority (7/8 of patients, 95% of fractions, and 96.6% of fields) are passing the less stringent Gamma criteria. The more stringent Gamma criteria caused a drop in pass rate (90 % of fractions, 84% of fields). For the patient with the lowest pass rate, wet towel bolus was used. Another patient with low pass rates experienced masseter muscle wasting. Conclusion: EPID dosimetry using the PerFraction software demonstrated that the majority of fields passed a Gamma (3%/3mm) for IMRT treatments delivered with a TrueBeam HD120 MLC. Pass rates dropped for a DTA of 1mm to model SRS tolerances. PerFraction pass rates can flag missing bolus or internal shields. Sanjeev Saini is an employee of Sun Nuclear Corporation. For this study, a pre-release version of PerFRACTION 1.1 software from Sun Nuclear Corporation was used.

60 APPLIED LIFE SCIENCES↗

Cloud Computing Option for Modeling the Debris Environment

NASA’s Digital Transformation Initiative aims to promote the agency’s adoption of current and evolving digital technologies. Through agency-wide collaboration with other NASA teams, the Office of Safety and Mission Assurance (OSMA) has directed the Orbital Debris Program Office and the Meteoroid Environment Office to integrate cloud computing technologies into their publicly released software models: the Orbital Debris Engineering Model (ORDEM) and the Meteoroid Engineering Model (MEM). Decoupling the user interface from the backend processor was key for the software packages to run on a cloud computing framework. Benefits to this design include horizontal scaling of computing resources, user authentication and authorization, and automated deployment. Both models are hosted on a cloud computing platform supported by the NASA authorized IT security and compliance framework. This paper focuses on the new ORDEM web application, which includes the current features of the publicly released ORDEM software with an upgraded frontend design, although parallels between ORDEM and MEM are also discussed. The underlying ORDEM processor is run on a cloud container, allowing the user to run multiple spacecraft and telescope/radar mode simulations. Features exclusive to the ORDEM web application, such as importing multiple TLEs, auto-generated plotting, and the ability to check runtime progress are discussed. Comparisons between the current ORDEM software and the web application are summarized.

Andrew Vavrin↗

Utilizing Code Generation from Models for Electric Aircraft Motor Controller Flight Software

The processes followed to develop and test safety-critical flight software significantly increase development effort and overhead in comparison to both non-safety-critical and non-flight software. Generating code from models can be used to reduce development effort; however, the processes for using code generation to develop flight software are relatively immature. This work presents an approach for developing safety-critical flight software utilizing code generation from models to reduce development time and effort. The presented use-case is of electric aircraft motor control software developed for NASA's X-57 Maxwell aircraft.

flight software↗

Model-Based Verification and Validation of Spacecraft Avionics

Verification and Validation (V&V) at JPL is traditionally performed on flight or flight-like hardware running flight software. For some time, the complexity of avionics has increased exponentially while the time allocated for system integration and associated V&V testing has remained fixed. There is an increasing need to perform comprehensive system level V&V using modeling and simulation, and to use scarce hardware testing time to validate models; the norm for thermal and structural V&V for some time. Our approach extends model-based V&V to electronics and software through functional and structural models implemented in SysML. We develop component models of electronics and software that are validated by comparison with test results from actual equipment. The models are then simulated enabling a more complete set of test cases than possible on flight hardware. SysML simulations provide access and control of internal nodes that may not be available in physical systems. This is particularly helpful in testing fault protection behaviors when injecting faults is either not possible or potentially damaging to the hardware. We can also model both hardware and software behaviors in SysML, which allows us to simulate hardware and software interactions. With an integrated model and simulation capability we can evaluate the hardware and software interactions and identify problems sooner. The primary missing piece is validating SysML model correctness against hardware; this experiment demonstrated such an approach is possible.

MBV&V↗

Ndarts

Ndarts software provides algorithms for computing quantities associated with the dynamics of articulated, rigid-link, multibody systems. It is designed as a general-purpose dynamics library that can be used for the modeling of robotic platforms, space vehicles, molecular dynamics, and other such applications. The architecture and algorithms in Ndarts are based on the Spatial Operator Algebra (SOA) theory for computational multibody and robot dynamics developed at JPL. It uses minimal, internal coordinate models. The algorithms are low-order, recursive scatter/ gather algorithms. In comparison with the earlier Darts++ software, this version has a more general and cleaner design needed to support a larger class of computational dynamics needs. It includes a frames infrastructure, allows algorithms to operate on subgraphs of the system, and implements lazy and deferred computation for better efficiency. Dynamics modeling modules such as Ndarts are core building blocks of control and simulation software for space, robotic, mechanism, bio-molecular, and material systems modeling.

Jain, Abhinandan↗

Comparison of Patient Skin Dose Evaluated Using Radiochromic Film and Dose Calculation Software

PurposeTo compare, in an interventional radiology setting, peak skin doses (PSDs) delivered as calculated using a dedicated software tool and as measured using radiochromic film. To assess the utility of this dose calculation software tool in routine clinical practice.Materials and MethodsFirst, radiochromic films were positioned on the examination table in the back of an adult anthropomorphic phantom to measure PSD, and X-ray examinations were simulated. Then, films were again positioned in the patient’s back for 59 thoracic or abdominopelvic endovascular interventions. The results obtained with the radiochromic films were taken as a reference and were statistically compared with those of the software.ResultsWith measured PSDs ranging from 100 to 7000 mGy, the median software–film difference was 8.5%. Lin’s concordance coefficient was 0.98 [0.97; 0.99] (p < 0.001), meaning that concordance was excellent between the two methods. For the films where PSD exceeded 1000 mGy, the median difference in the measured value was 8.7% [− 1.3; 21.1], with a maximum discrepancy of 34%. Lin’s concordance coefficient was 0.98 [0.96; 1] (p < 0.001), meaning that concordance was excellent between the two methods.ConclusionComparison between radiochromic films and the software tool showed that the software is a suitable tool for a simple and reliable estimation of PSD. The software seems to be a good alternative to films, whose use remains complex.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advanced software techniques for data management systems. Volume 3: Programming language characteristics and comparison reference

A comparative evaluation was made of eight higher order languages of general interest in the aerospace field: PL/1; HAL; JOVIAL/J3; SPL/J6; CLASP; ALGOL 60; FORTRAN 4; and MAC360. A summary of the functional requirements for a language for general use in manned aerodynamic applications is presented. The evaluation supplies background material to be used in assessing the worth of each language for some particular application.

James, T. A.↗

Solar Sail GN and C Model Comparisons

The Solar Sail Propulsion project is engaged in an ambitious program to raise the Technology Readiness Level of solar sails and prepare for a validation flight via a series of hardware ground demonstrations and development of a number of high fidelity simulations and models. Guidance, navigation, and control of solar sails is a key part of this effort. The large flexible structure and optical nature of solar sails create a considerable challenge for attitude control, thrust modeling, and navigation. In this paper, we present an overview and comparison of two recently delivered prototype solar sail guidance, navigation, and control software tools currently funded by the Solar Sail Propulsion project. The results of some key test cases are presented. Where possible, we also make comparisons to other software tools. We discuss the implications of the results of these comparative studies to the future direction and scope of development efforts for guidance, navigation and control software for solar sails, including the relationship to hardware test efforts such as the Thrust Vector Control Authority Demonstration.

Heaton, Andrew F.↗

Screening of the Suzuki Cross-Coupling Reaction Using Desorption Electrospray Ionization in High-Throughput and in Leidenfrost Droplet Experiments

Suzuki cross-coupling is a widely performed reaction, typically using metal catalysts under heated conditions. Acceleration of the Suzuki cross-coupling reaction has been previously explored in microdroplets using desorption electrospray ionization mass spectrometry (DESI-MS). Building upon previous work, presented here is the use of a high-throughput DESI-MS screening system to identify optimal reaction conditions. Multiple reagents, bases, and stoichiometries were screened using the automated system at rates that approach 10,000 reaction mixture systems per hour. The DESI-MS system utilizes reaction acceleration in microdroplets to allow rapid screening. The results of screening of an array of reaction mixtures using this technique are presented as product ion images via standard MS imaging software, facilitating quick readout. Instructive comparisons are provided with another method of generating droplets for reaction acceleration—the Leidenfrost technique. Acceleration factors greater than 200 were measured for brominated substrates, paralleling the DESI-MS results. Acceleration factors dropped to near unity with highly substituted pyridines, attributable to a steric effect. The reaction proceeded in the absence of a base in Leidenfrost droplets although no product formation was seen without base in the bulk or in the DESI-MS screening experiments. These differences between Leidenfrost chemistry and the bulk and in droplets formed in high-throughput DESI are tentatively attributed to extremes of pH associated with the surfaces of Leidenfrost droplets. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A new fuel modeling capability, CTFFuel, with a case study on the fuel thermal conductivity degradation

Here, a new fuel modeling capability, CTFFuel, is developed from the subchannel code, CTF. This code is a standalone interface to the CTF fuel rod models, allowing for fuel rod simulations to be run independently from the fluid. This paper provides an overview of the code with a case study on the thermal conductivity degradation of LWR fuels to demonstrate its capabilities. The modeling of fuel thermal conductivity degradation in the code is improved through the addition of new modeling options to account for the irradiation effects via globally defined parameters. After the initial implementation, a variety of order-of-accuracy tests and code comparisons are performed to test software quality. A controlled analysis is allowed by CTFFuel to verify the numerical scheme of CTF’s conduction solution and to benchmark its fuel temperature predictions against FRAPCON-4.0’s. Overall, the software quality and verification procedure ensures that the new model is coded correctly, that it properly interacts with the rest of the code.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The optimization of high resolution topographic data for 1D hydrodynamic models

The main focus of our research presented in this paper is to optimize and use high resolution topographical data (HRTD) for hydrological modelling. Optimization of HRTD is done by generating adaptive mesh by measuring distance of coarse mesh and the surface of the dataset and adapting the mesh from the perspective of keeping the geometry as close to initial resolution as possible. Technique described in this paper enables computation of very accurate 1-D hydrodynamic models. In the paper, we use HEC-RAS software as a solver. For comparison, we have chosen the amount of generated cells/grid elements (in whole discretization domain and selected cross sections) with respect to preservation of the accuracy of the computational domain. Generation of the mesh for hydrodynamic modelling is strongly reliant on domain size and domain resolution. Topographical dataset used in this paper was created using LiDAR method and it captures 5.9km long section of a catchment of the river Olše. We studied crucial changes in topography for generated mesh. Assessment was done by commonly used statistical and visualization methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-148: Efficient Verification Method for Modulated Electron Radiotherapy Treatment Plans

Purpose: For shallow tumors, modulated electron radiotherapy (MERT) promises a reduction of dose to distal organs at risk. At our institution a framework was developed in order to create treatment plans for MERT employing both forward and inverse optimization. In this work, an efficient quality assurance (QA) process is established. Methods: Treatment plans for three different tumor sites were created using an inverse optimization. These plans consist of 6–12 segments and energies between 6 and 18 MeV. An already established QA process for photon IMRT plans is now extended to additionally handle MERT plans. First, the dose distributions are calculated in a homogenous water phantom. For this task a dedicated Monte Carlo (MC) framework for MERT is used. Second, the segments are applied on a stand-alone amorphous silicon electronic portal imaging device (EPID) using a source-to-surface distance of 70 cm. This device was calibrated for electron beams in a previous work. An in-house developed analysis software, is then utilized for comparisons and evaluation of the measured and calculated dose distributions. Results: For all three plans the calculated dose distributions agree well with the measured ones. Using a 2D gamma comparison (2% of dose max/2 mm and 10% dose threshold) passing rates >98% are achieved.The dose calculation for each plan on the water phantom, using voxels of 0.2×0.2×0.2 cm{sup 3}, takes at maximum 30 min on a single core Pentium 2.66 GHz system with 6 GB RAM, to reach a statistical uncertainty of 2% (1 std. dev.). Conclusion: An already established QA procedure for IMRT photon plans was applied for MERT. The dedicated MC framework and the use of EPID measurements allow an efficient QA procedure in a clinical environment. This work was supported by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-E-I-51: Quantitative Assessment of X-Ray Imaging Detector Performance in a Clinical Setting - a Simple Approach Using a Commercial Instrument

Purpose: To measure and compare the performance of X-ray imaging detectors in a clinical setting using a dedicated instrument for the quantitative determination of detector performance. Methods: The DQEPro (DQE Instruments Inc., London, Ontario Canada) was used to determine the MTF, NPS and DQE using an IEC compliant methodology for three different imaging modalities: conventional radiography (CsI-based detector), general-purpose radioscopy (CsI-based detector), and mammography (a-Se based detector). The radiation qualities (IEC) RQA-5 and RQA-M-2 were used for the CsI-based and a-Se-based detectors, respectively. The DQEPro alleviates some of the difficulties associated with DQE measurements by automatically positioning test devices over the detector, guiding the user through the image acquisition process and providing software for calculations. Results: A comparison of the NPS showed that the image noise of the a-Se detector was less correlated than the CsI detectors. A consistently higher performance was observed for the a-Se detector at all spatial frequencies (MTF: 0.97@0.25 cy/mm, DQE: 0.72@0.25 cy/mm) and the DQE drops off slower than for the CsI detectors. The CsI detector used for conventional radiography displayed a higher performance at low spatial frequencies compared to the CsI detector used for radioscopy (DQE: 0.65 vs 0.60@0.25 cy/mm). However, at spatial frequencies above 1.3 cy/mm, the radioscopy detector displayed better performance than the conventional radiography detector (DQE: 0.35 vs 0.24@2.00 cy/mm). Conclusion: The difference in the MTF, NPS and DQE that was observed for the two different CsI detectors and the a-Se detector reflect the imaging tasks that the different detector types are intended for. The DQEPro has made the determination and calculation of quantitative metrics of X-ray imaging detector performance substantially more convenient and accessible to undertake in a clinical setting.

60 APPLIED LIFE SCIENCES↗

Replicated computational results (RCR) report for "BLIS: A framework for rapidly instantiating BLAS functionality"

“BLIS: A Framework for Rapidly Instantiating BLAS Functionality” includes single-platform BLIS performance results for both level-2 and level-3 operations that is competitive with OpenBLAS, ATLAS, and Intel MKL. A detailed description of the configuration used to generate the performance results was provided to the reviewer by the authors. All the software components used in the comparison were reinstalled and new performance results were generated and compared to the original results. After completing this process, the published results are deemed replicable by the reviewer.

97 MATHEMATICS AND COMPUTING↗