Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CESIUM ION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Electron-Transfer Activation of Thiophene

The research supported by contract FG02-90ER14146 from the U.S. Department of Energy to Thomas B. Rauchfuss is summarized. Seven research themes are described. The work on thiophenes identified pathways for desulfurization that are initiated by electron transfer or hydrolysis. Using similar half-sandwich platforms, a large family of molecular cyanometallate cages were prepared. These cages exhibit host-guest behavior, with a notable affinity for cesium ions. A series of investigations made pioneering contributions to the understanding of the catalytic properties of the hydrogenase enzymes. Work on molecular metal sulfides focused on elucidating hydrogen activation pathways, relevant to the corresponding reactions that are invoked for metal sulfide heterogeneous catalysts. The theme of proton-activated catalysis was continued with the elucidation of the effects of Bronsted acids and oxidation on inducing H2 activation by metal-amides. The proton-activation theme was shown to be a powerful vehicle for upgrading bio-derives substrates including sugars. The project concluded with emphasis on developing ligand platforms that facilitate the use of earth-abundant metals in homogeneous catalysis.

09 BIOMASS FUELS↗

Device for measuring electric fields

Measurement of low-intensity electric fields in space and in presence of weak magnetic fields is accomplished by utilizing a device which permits determination of the extent a beam of cesium ions is deflected by an electric field.

Levine, S. H.↗

Design and development of a Micropound Extended Range Thrust Stand (MERTS)

The development and operation of a micropound extended range thrust stand are considered. A cesium ion engine was tested in order to determine the measurement accuracy of the apparatus and to verify the calibration techniques used. The ion engine was tracked to within 5 percent. A check of the thrust stand calibration factor against that of the ion engine calibration factor showed a 4.3 percent difference.

Stark, K. W.↗

Data from a synchronous altitude satellite quartz crystal microbalance monitor

Results of one year's operation in orbit of the Quartz Crystal Microbalance Monitor on the ATS-6 satellite are presented. The data indicate a general decreasing trend for the first four and one-half months in orbit. At that time, a sudden increase in beat frequency occurred; this correlates in time with the firing of the North Cesium Ion Engine. A general increase in beat frequency is evidenced since that time. Laboratory tests conducted to investigate the phenomenon are described.

Rogers, J. F.↗

ATS-6 - Quartz-Crystal Microbalance

The Quartz-Crystal Microbalance Experiment provided data on the possible return of contaminants to the exterior surfaces of the spacecraft. The experiment measures the change in resonant frequency of the crystal due to deposition of material on the surface. There has been no mass accretion corresponding to the firing of hydrazine thrusters to unload the spacecraft momentum wheels. There have been accretions corresponding to the firing of the cesium ion engines.

Rogers, J. F.↗

Low arc drop hybrid mode thermionic converter

The hybrid mode operation for the reduction of plasma drops is being investigated. This report discusses the results obtained from two molybdenum emitter converters. One converter had a molybdenum collector and the other a nickel collector. The molybdenum collector converter was operated in a hybrid mode (at an interelectrode distance of 1.7 mm) and produced a minimum barrier index of 1.96 eV at an emitter temperature of 1500 K. The arc drop was calculated to be 0.14 eV, using the published results for a molybdenum collector. On the other hand, the nickel collector converter was operated in a conventional ignited mode (at an interelectrode distance of 0.5 mm) and produced a minimum barrier index of 2.1 eV at an emitter temperature of 1700 K. It is tentatively concluded that a large-gap operation of the hybrid mode converter permits the diffusion of cesium ions to a distance in the order of one millimeter for an effective neutralization of electron space charge. By employing a low work function collector (1.55 eV) in a hybrid mode converter with an arc drop of 0.14 eV, it appears that a barrier index as low as 1.69 eV could be achieved.

Shimada, K.↗

Manufacture of ionizers intended for electric propulsion

An electric propulsion system which relies on the formation of cesium ions in contact with a porous wall made of a metal with a high work function when the wall is heated to 1500 K was described. The manufacture of porous walls on the mountings was considered. Erosion of the electrodes by slow ions was examined, and the life times of the ionizers was estimated by means of experimental studies. The purpose of the electric propulsion system was to bring about minor corrections in the orbits of geostationary satellites; the main advantage of this system was that it weighs less than currently used hydrazine systems.

Hivert, A.↗

Recent progress in hybrid mode thermionic converter development

Thermionic research has been conducted to investigate a hybrid-mode thermionic converter as a candidate for reducing the barrier index. The hybrid-mode thermionic converter is designed to operate in a combination ignited mode and unignited mode by using a series of parallel grooves in the emitter. The emitter material is molybdenum and the non-grooved land area is thinly coated with rhenium metal. When the emitter is exposed to cesium vapor, as it is during the converter operation, the rhenium-coated land area achieves a lower work function than the grooved molybdenum surface by as much as 0.5 eV. The low work function land area provides a major portion of electron emission, and the high work function grooved area provides cesium ions required for efficient transport of electrons generated in adjacent land areas to the collector. Experimental results obtained from two different converters and a numerical analysis of converter characteristics are presented in this paper.

Shimada, K.↗

Advances in the Glass Formulations for the Hanford Tank Waste Treatment and Immobilization Plant

The Department of Energy-Office of River Protection (DOE-ORP) is constructing the Hanford Tank Waste Treatment and Immobilization Plant (WTP) to treat radioactive waste currently stored in underground tanks at the Hanford site in Washington. The WTP that is being designed and constructed by a team led by Bechtel National, Inc. (BNI) will separate the tank waste into High Level Waste (HLW) and Low Activity Waste (LAW) fractions with the majority of the mass (~90%) directed to LAW and most of the activity (>95%) directed to HLW. The pretreatment process, envisioned in the baseline, involves the dissolution of aluminum-bearing solids so as to allow the aluminum salts to be processed through the cesium ion exchange and report to the LAW Facility. There is an oxidative leaching process to affect a similar outcome for chromium-bearing wastes. Both of these unit operations were advanced to accommodate shortcomings in glass formulation for HLW inventories. A by-product of this are a series of technical challenges placed upon materials selected for the processing vessels. The advances in glass formulation play a role in revisiting the flow sheet for the WTP and hence, the unit operations that were being imposed by minimal waste loading requirements set forth in the contract for the design and construction of the plant. Another significant consideration to the most recent revision of the glass models are the impacts on resolution of technical questions associated with current efforts for design completion.

Kruger, Albert A.↗

Inclusion property of Cs, Sr, and Ba impurities in LiCl crystal formed by layer-melt crystallization

Pyroprocessing is one of the promising technologies enabling the recycling of spent nuclear fuels from a commercial light water reactor (LWR). In general, pyroprocessing uses dry molten salts as electrolytes. In particular, LiCl waste salt after pyroprocessing contains highly radioactive I/II group fission products mainly composed of Cs, Sr, and Ba impurities. Therefore, it is beneficial to reuse LiCl salt in the pyroprocessing as an electrolyte for economic and environmental issues. Herein, to understand the inclusion property of impurities within LiCl crystal, the physical properties such as lattice parameter change, bulk modulus, and substitution enthalpy of a LiCl crystal having 0-6 at% Cs{sup +} or Ba{sup 2+} impurities under existence of 1 at% Sr{sup 2+} impurity were calculated via the first-principles density functional theory. The substitution enthalpy of LiCl crystals having 1 at% Sr{sup 2+} showed slightly decreased value than those without Sr{sup 2+} impurity. Therefore, through the substitution enthalpy calculation, it is expected that impurities will be incorporated within LiCl crystal as co-existed form rather than as a single component form. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multiple delivery cesium oven system for negative ion sources

Distribution of cesium in large negative ion beam sources to be operational in ITER, is presently based on the use of three or more cesium ovens, which operate simultaneously and are controlled remotely. However, use of multiple Cs ovens simultaneously is likely to pose difficulties in operation and maintenance of the ovens. An alternate method of Cs delivery, based on a single oven distribution system is proposed as one which could reduce the need of simultaneous operation of many ovens. A proof of principle experiment verifying the concept of a multinozzle distributor based Cs oven has been carried out at Institute for Plasma Research. It is also observed that the Cs flux is not controlled by Cs reservoir temperature after few hours of operation but by the temperature of the distributor which starts behaving as a Cs reservoir.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interaction of Cesium and Barium Ions with Calcium Silicate Hydrate under a Geological Temperature Condition - 16239

The interaction of calcium-silicate-hydrate (CSH gel) and cationic radionuclides such as cesium-135 significantly affects the assessment of radionuclide migration. This study examined the influence of temperature on the interaction of Cs and barium (Ba) ions with CSH gel because temperature generally affects chemical reactions such as sorption. In the sorption experiments, CSH gel was prepared by the hydration of CaO and fumed silica without a drying process, with Ca/Si molar ratios ranging from 0.4 to 1.6 and the liquid/solid weight ratio set to 20. The concentration of Cs and/or Ba ions was adjusted to 1.0 mM. The temperature conditions during the sorption experiments for 14 days were set to 298, 313 and 333 K. As a result, the sorption of Cs ions on CSH gel increased at higher temperature. Moreover, Raman spectroscopy studies showed that the silicate chain of CSH gel depolymerized with the increase in temperature. That is, the structural deformation of CSH gel at a relatively high temperature facilitates the sorption of Cs ions. On the other hand, the sorption of Ba ions on CSH gel remained high (90 %) regardless of temperature, and hardly affected the sorption of Cs ions. These findings suggest that CSH gel around the repository is expected to further retard the migration of cationic radionuclides under temperature condition up to 333 K. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantification Of Cesium In Negative Hydrogen Ion Sources By Laser Absorption Spectroscopy

The use of cesium in negative hydrogen ion sources and the resulting cesium dynamics caused by the evaporation and redistribution in the vacuum and plasma phase makes a reliable and on-line monitoring of the cesium amount in the source highly desirable. For that purpose, a robust and compact laser absorption setup suitable for the ion source environment has been developed utilizing the Cs D{sub 2} resonance line at 852.1 nm. First measurements are taken in a small laboratory plasma chamber with cesium evaporation. A detection limit of {approx_equal}5x10{sup 13} m{sup -3} at a typical path length of 15 cm has been obtained with a dynamic range of more than three orders of magnitude, limited by line saturation at high densities. For on-line monitoring an automatic data analysis is established achieving a temporal resolution of 100 ms. The setup has then been applied to the ITER prototype ion sources developed at IPP. It is been shown that the method is well suited for routine measurements revealing a new insight into the cesium dynamics during source operation and cesium conditioning.

43 PARTICLE ACCELERATORS↗

Enhanced capacity and stability for the separation of cesium in electrically switched ion exchange

Electrically switched ion exchange (ESIX) can be used to separate ionic contaminants from industrial wastewater, including that generated by the nuclear industry. The ESIX method involves sequential application of reduction and oxidation potentials to an ion exchange film to induce the respective loading and unloading of cesium. This technology is superior to conventional methods (e.g electrodialysis reversal or reverse osmosis) as it requires very little energy for ionic separation. In previous studies, ESIX films have demonstrated relatively low ion exchange capacities and limited film stabilities over repeated potential applications. In this study, the methodology for the deposition of electro-active films (nickel hexacyanoferrate) on nickel electrodes was modified to improve the ion exchange capacity for cesium removal using ESIX. Cyclic voltammetry was used to investigate the ion exchange capacity and stability. Scanning electron microscopy (SEM) was used to characterize the modified film surfaces. Additionally, the films were examined for the separation of cesium ions. This modified film preparation technique enhanced the ion exchange capacity and improves the film stability compared to previous methods for the deposition of ESIX films. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗