Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CALORIMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The BigBite Calorimeter for the Super Bigbite Spectrometer Program at Jefferson Lab

Here, we report features of the design, construction, installation, and performance of the BigBite Calorimeter (BBCal), a lead-glass electromagnetic calorimeter constructed as part of the BigBite Spectrometer (BBS), which served as the electron arm for the Super Bigbite Spectrometer (SBS) program of high-precision neutron electromagnetic form factor measurements in Hall A at Jefferson Lab. As a total-absorption calorimeter, BBCal provided the primary electron trigger for BBS, detecting quasi-elastically scattered electrons in the 1–4 GeV energy range with an energy resolution of approximately 6.2%, position resolution of 1.2 cm, and timing resolution of 0.5 ns.

BBCal↗

sPHENIX Calorimeter Design and Jet Performance

The PHENIX collaboration is planning a detector upgrade, sPHENIX, which consists of large acceptance calorimetry and tracking detectors built around the superconducting solenoid recently shipped to Brookhaven from the decommissioned BaBar experiment at SLAC. The sPHENIX calorimeter system includes three radial layers of samplingcalorimeters, a tungsten-scintillating fiber electromagnetic calorimeter, and two longitudinally segmented samplinghadron calorimeters that are made of scintillator tiles and steel plates. Together, they provide hermetic coverage in n < 1 for calorimetry based jet measurements as well as minimal bias jet trigger capability, which coupled with high resolution tracking, enable an extremely rich jet physics program at RHIC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impedance Measurement of a Gamma-Ray TES Calorimeter with a Bulk Sn Absorber

We performed complex impedance measurements with a Ti/Au-based gamma-ray TES calorimeter with a bulk Sn absorber. Excellent energy resolution of 38.4{+-}0.9eV at 60 keV was observed. The impedance of the calorimeter can be well explained by a two-body thermal model. We investigated the behavior of the parameters of the calorimeter during the superconducting-to-normal transition. We confirmed that C and G{sub a} are in good agreement with the predicted values. We performed a noise analysis and found several excess noise components, as well as internal thermal fluctuation noise (ITFN) term due to the thermal conductance between the Sn absorber and the Ti/Au TES. Dominanting the noise is an excess noise having a similar frequency dependence to the phonon noise and the ITFN noise.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The ALICE Electromagnetic Calorimeter

ALICE (A Large Ion Collider Experiment) is the only LHC experiment at CERN fully dedicated to the study of the quark and gluon plasma. Driven by the RHIC results on jet quenching, the ALICE collaboration has proposed to extend the capabilities of the ALICE detector for the study of high momentum photons and jets by adding a large acceptance calorimeter. This EMCal (ElectroMagnetic Calorimeter) is designed to provide an unbiased fast high-p{sub T} trigger and to measure the neutral energy of jets and photons up to 200 GeV. Four over ten supermodules of the calorimeter have been installed and commissioned at CERN in 2009 which represents 40% of the full acceptance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The calorimeter of the Mu2e experiment at Fermilab

Here, the Mu2e experiment at Fermilab looks for Charged Lepton Flavor Violation (CLFV) improving by 4 orders of magnitude the current experimental sensitivity for the muon to electron conversion in a muonic atom. A positive signal could not be explained in the framework of the current Standard Model of particle interactions and therefore would be a clear indication of new physics. In 3 years of data taking, Mu2e is expected to observe less than one background event mimicking the electron coming from muon conversion. Achieving such a level of background suppression requires a deep knowledge of the experimental apparatus: a straw tube tracker, measuring the electron momentum and time, a cosmic ray veto system rejecting most of cosmic ray background and a pure CsI crystal calorimeter, that will measure time of flight, energy and impact position of the converted electron. The calorimeter has to operate in a harsh radiation environment, in a 10 -4 Torr vacuum and inside a 1 T magnetic field. The results of the first qualification tests of the calorimeter components are reported together with the energy and time performances expected from the simulation and measured in beam tests of a small scale prototype.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the ALICE Electromagnetic Calorimeter

The performance of the electromagnetic calorimeter of the ALICE experiment during operation in 2010–2018 at the Large Hadron Collider is presented. After a short introduction into the design, readout, and trigger capabilities of the detector, the procedures for data taking, reconstruction, and validation are explained. The methods used for the calibration and various derived corrections are presented in detail. Subsequently, the capabilities of the calorimeter to reconstruct and measure photons, light mesons, electrons and jets are discussed. The performance of the calorimeter is illustrated mainly with data obtained with test beams at the Proton Synchrotron and Super Proton Synchrotron or in proton-proton collisions at $\sqrt{s}$ = 13 TeV, and compared to simulations.

47 OTHER INSTRUMENTATION↗

Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20–300 GeV/c

The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing medium and silicon sensors as an active medium in the regions of high radiation exposure, and scintillator tiles directly read out by silicon photomultipliers in the remaining regions. As part of the development of the detector and its readout electronic components, a section of a silicon-based HGCAL prototype detector along with a section of the CALICE AHCAL prototype was exposed to muons, electrons and charged pions in beam test experiments at the H2 beamline at the CERN SPS in October 2018. The AHCAL uses the same technology as foreseen for the HGCAL but with much finer longitudinal segmentation. The performance of the calorimeters in terms of energy response and resolution, longitudinal and transverse shower profiles is studied using negatively charged pions, and is compared to GEANT4 predictions. This is the first report summarizing results of hadronic showers measured by the HGCAL prototype using beam test data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the local reconstruction algorithms for the CMS hadron calorimeter with Run 2 data

A description is presented of the algorithms used to reconstruct energy deposited in the CMS hadron calorimeter during Run 2 (2015–2018) of the LHC. During Run 2, the characteristic bunch-crossing spacing for proton-proton collisions was 25 ns, which resulted in overlapping signals from adjacent crossings. The energy corresponding to a particular bunch crossing of interest is estimated using the known pulse shapes of energy depositions in the calorimeter, which are measured as functions of both energy and time. A variety of algorithms were developed to mitigate the effects of adjacent bunch crossings on local energy reconstruction in the hadron calorimeter in Run 2, and their performance is compared.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using graph neural networks to reconstruct charged pion showers in the CMS High Granularity Calorimeter

A novel method to reconstruct the energy of hadronic showersin the CMS High Granularity Calorimeter (HGCAL) is presented. TheHGCAL is a sampling calorimeter with very fine transverse andlongitudinal granularity. The active media are silicon sensors andscintillator tiles readout by SiPMs and the absorbers are acombination of lead and Cu/CuW in the electromagnetic section, andsteel in the hadronic section. The shower reconstruction method isbased on graph neural networks and it makes use of a dynamicreduction network architecture. It is shown that the algorithm isable to capture and mitigate the main effects that normally hinderthe reconstruction of hadronic showers using classicalreconstruction methods, by compensating for fluctuations in themultiplicity, energy, and spatial distributions of the shower'sconstituents. The performance of the algorithm is evaluated usingtest beam data collected in 2018 prototype of the CMS HGCALaccompanied by a section of the CALICE AHCAL prototype. Thecapability of the method to mitigate the impact of energy leakagefrom the calorimeter is also demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Poster — Thur Eve — 22: A water calorimeter for low-energy particle beams

In this work, the feasibility of absolute dose to water measurements in low-energy electron beams using a water calorimeter specifically developed for shallow measurements is established. The calorimeter design consists of a cylindrical glass vessel encased in a block of expanded polystyrene. The vessel has a front window thickness of 1.1 mm, a 4 cm radius, and is 2.5 cm in depth. The vessel-block assembly sits inside a thermally-insulated box and is air-cooled to an operating temperature of 4 °C. Radiation-induced thermal gradients were simulated in a geometric model of the calorimeter using a finite element analysis software package. 52 absorbed dose to water measurements were performed in a 6 and 8 MeV electron beam (z{sub max} of 1.32 and 1.76 cm, respectively) for 60 seconds at a repetition rate of 400 MU/min and an SSD of 120 cm. Within the vessel, the depth of measurement was set to 1.08 cm relative to the inner front window. The average measured dose to water was 59.6 ± 0.2 cGy/100 MU (6 MeV), and 63.7 ± 0.3 cGy/100 MU (8 MeV). The associated heat transfer corrections were determined to be 1.026 ± 0.003 and 1.017 ± 0.004 for the 6 and 8 MeV beams, respectively. The most significant source of uncertainty in this study was the repeatability (type A, 0.42%). It is expected that performing fewer consecutive measurements under higher dose rate conditions will improve the stability of the thermal background, thereby improving the repeatability and reducing the overall standard uncertainty.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-207-05: Excess Heat Corrections in a Prototype Calorimeter for Direct Realization of CT Absorbed Dose to Phantom

Purpose: To reconcile air kerma and calorimetry measurements in a prototype calorimeter for obtaining absorbed dose in diagnostic CT beams. While corrections for thermal artifacts are routine and generally small in calorimetry of radiotherapy beams, large differences in relative stopping powers of calorimeter materials at the lower energies typical of CT beams greatly magnify their effects. Work-to-date on the problem attempts to reconcile laboratory measurements with modeling output from Monte Carlo and finite-element analysis of heat transfer. Methods: Small thermistor beads were embedded in a polystyrene (PS) core element of 1 cm diameter, which was inserted into a cylindrical HDPE phantom of 30 cm diameter and subjected to radiation in a diagnostic CT x-ray imaging system. Resistance changes in the thermistors due to radiation heating were monitored via lock-in amplifier. Multiple 3-second exposures were recorded at 8 different dose-rates from the CT system, and least-squares fits to experimental data were compared to an expected thermal response obtained by finite-element analysis incorporating source terms based on semi-empirical modeling and Monte Carlo simulation. Results: Experimental waveforms exhibited large thermal artifacts with fast time constants, associated with excess heat in wires and glass, and smaller steps attributable to radiation heating of the core material. Preliminary finite-element analysis follows the transient component of the signal qualitatively, but predicts a slower decay of temperature spikes. This was supplemented by non-linear least-squares fits incorporating semi-empirical formulae for heat transfer, which were used to obtain dose-to-PS in reasonable agreement with the output of Monte Carlo calculations that converts air kerma to absorbed dose. Conclusion: Discrepancies between the finite-element analysis and our experimental data testify to the very significant heat transfer correction required for absorbed dose calorimetry of diagnostic CT beams. The results obtained here are being used to refine both simulations and design of calorimeter core components.

60 APPLIED LIFE SCIENCES↗

Status of the endcap BGO calorimeter of the CMD-3 detector

The electromagnetic endcap BGO calorimeter of the CMD-3 detector is ready for experiments at the new e{sup +}e{sup -} collider VEPP-2000. Light readout is performed by silicon photodiodes. A thermalcontrol system that is able to maintain the calorimeter temperature at a level of 12 {+-}1 deg. C was designed and manufactured. All blocks of the endcap calorimeter are assembled, tested, and prepared for installing at the detector.

43 PARTICLE ACCELERATORS↗

Simulations for CMS hadron endcap calorimeter upgrade at HL-LHC

The upgrade of the present endcap calorimeters is foreseen to prepare the CMS experiment for the High Luminosity LHC. Integrated doses at the location of the front layers of the hadron endcap calorimeter are expected to reach 20 Mrad. Studies of radiation fields are presented in this report. At the same time, the effects of pileup will become more severe, making the identification of jet objects more challenging. We estimated the effects of different transverse segmentations of back hadron calorimeter (BH) for CMS upgrade.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electromagnetic Calorimeter of the Belle-II Detector

The electromagnetic calorimeter for the Belle-II detector is briefly described. The algorithm of reconstruction of amplitude and time of calorimeter signals is described. The status of preparation of the electromagnetic calorimeter for the data-taking is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The modular nuclear absorber of the ATLAS hadron calorimeter (The experience controlled assembly of the surface and in the pit).

The Hadron Calorimeter of the ATLAS spectrometric complex is a principal part of the whole setup. This paper describes the developed concept and methods for the controlled construction of a steel nuclear calorimeter absorber which provides calorimeter assembly on the surface and in the underground experimental hall meeting the required design tolerances.

36 MATERIALS SCIENCE↗

D0 Decommissioning: Storage of depleted uranium modules inside D0 calorimeters after the termination of D0 experiment

Dzero liquid Argon calorimeters contain hadronic modules made of depleted uranium plates. After the termination of D0 detector's operation, liquid Argon will be transferred back to Argon storage Dewar, and all three calorimeters will be warmed up. At this point, there is no intention to disassemble the calorimeters. The depleted uranium modules will stay inside the cryostats. Depleted uranium is a by-product of the uranium enrichment process. It is slightly radioactive, emits alpha, beta and gamma radiation. External radiation hazards are minimal. Alpha radiation has no external exposure hazards, as dead layers of skin stop it; beta radiation might have effects only when there is a direct contact with skin; and gamma rays are negligible - levels are extremely low. Depleted uranium is a pyrophoric material. Small particles (such as shavings, powder etc.) may ignite with presence of Oxygen (air). Also, in presence of air and moisture it can oxidize. Depleted uranium can absorb moisture and keep oxidizing later, even after air and moisture are excluded. Uranium oxide can powder and flake off. This powder is also pyrographic. Uranium oxide may create health problems if inhaled. Since uranium oxide is water soluble, it may enter the bloodstream and cause toxic effects.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Applying fast calorimetry on a spent nuclear fuel calorimeter

Recently at Los Alamos National Laboratory, sophisticated prediction algorithms have been considered for the use of calorimetry for treaty verification. These algorithms aim to predict the equilibrium temperature based on early data and therefore be able to shorten the measurement time while maintaining good accuracy. The algorithms have been implemented in MATLAB and applied on existing equilibrium measurements from a spent nuclear fuel calorimeter located at the Swedish nuclear fuel interim storage facility. The results show significant improvements in measurement time in the order of 15 to 50 compared to equilibrium measurements, but cannot predict the heat accurately in less time than the currently used temperature increase method can. This Is both due to uncertainties in the calibration of the method as well as identified design features of the calorimeter that limits the usefulness of equilibrium type measurements. The conclusions of these findings are discussed, and suggestions of both improvements of the current calorimeter as well as what to keep in mind in a new design are given.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Search for new physics in the Compact Muon Solenoid (CMS) experiment and the response of the CMS calorimeters to particles and jets

A Monte Carlo study of a generic search for new resonances beyond the Standard Model (SM) in the CMS experiment is presented. The resonances are axigluon, coloron, E 6 diquark, excited quark, W', Z', and the Randall-Sundrum graviton which decay to dijets. The dijet resonance cross section that the CMS can expect to discover at a 5σ significance or to exclude at 95% confidence level for integrated luminosities of 100 pb -1 , 1 fb -1 , and 10 fb -1 is evaluated. It is shown that a 5σ discovery of a multi-TeV dijet resonance is possible for an axigluon, excited quark, and E 6 diquark. However, a 5σ discovery can not be projected with confidence for a W', Z' and the Randall-Sundrum graviton. On the other hand, 95% CL exclusion mass regions can be measured for all resonances at high luminosities. In the second part of this dissertation, the analyses of the 2006 test beam data from the combined electromagnetic and hadronic barrel calorimeters are presented. The CMS barrel calorimeters response to a variety of beam particles in a wide momenta range (1 to 350 GeV/c) is measured. Furthermore, using these beam data, the expected performance of the barrel calorimeters to jets is predicted.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗