Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Bone imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

STS-95 Day 07 Highlights

On this seventh day of the STS-95 mission, the flight crew, Cmdr. Curtis L. Brown, Pilot Steven W. Lindsey, Mission Specialists Scott E. Parazynski, Stephen K. Robinson, and Pedro Duque, and Payload Specialists Chiaki Mukai and John H. Glenn, again test the Orbiter Space Vision System. OSVS uses special markings on Spartan and the shuttle cargo bay to provide an alignment aid for the arm's operator using shuttle television images. It will be used extensively on the next Space Shuttle flight in December as an aid in using the arm to join together the first two modules of the International Space Station. Specialist John Glenn will complete a daily back-pain questionnaire by as part of a study of how the muscle, intervertebral discs and bone marrow change after exposure to microgravity.

Source record↗

In-situ observations of cyclic deformation in an extruded Mg-2Nd-1Y-0.1Zr-0.1Ca alloy

In this study, the evolution of deformation mechanisms during cyclic loading in an extruded, solution-treated Mg–2Nd–1Y–0.1Zr–0.1Ca alloy was investigated using a combination of in-situ loading, scanning electron microscopy (SEM), electron backscatter diffraction (EBSD), and focused ion beam (FIB) nanofabrication. The initial microstructure exhibited a random crystallographic texture with no preferred grain orientation. Flat, rectangular dog-bone specimens were subjected to load-controlled, fully reversed fatigue for 50 cycles, during which the same region was sequentially mapped to track microstructural changes. After 10 cycles of loading deformation twins were observed. During tensile reloading detwinning or narrowing of those twinned regions occurred. After 20 cycles, detwinning ceased and residual twins remained in the material. SEM imaging revealed numerous surface slip traces after cyclic loading. EBSD-assisted slip trace analysis identified the activation of prismatic and pyramidal < c+a> slip systems during low-cycle fatigue. Site-specific scanning transmission electron microscopy (STEM) further revealed that deformation was also accommodated by basal < a> slip and the dissociation of < c+a> dislocations. Center-of-symmetry (COS) analysis confirmed that the dissociation of < c+a> dislocations resulted in the formation of I₁ intrinsic stacking faults after cyclic loading. These findings provide new insights into the complex interplay of dislocation mechanisms governing fatigue deformation in rare-earth-containing Mg alloys.

Cyclic deformation↗

The Spacelab 2 mission - An overview

A summary is presented of the results of experiments on the Spacelab 2 mission, which was flown on the Shuttle Orbiter between July 29 and August 6, 1985. The background and flight of the mission and the payload configuration are examined. The experiments include the Ejectable Plasma Diagnostics Package, Vehicle Charging and Potential Experiment, and plasma detection experiments. Life science experiments include studies of the effects of spaceflight on the growth of plant tissues and perturbations of bone and calcium homeostasis in flight crew members. Solar studies include the Solar UV Spectral Irradiance Monitor, the Coronal Helium Abundance Spacelab Experiment, the High Resolution Telescope and Spectrograph, the Solar Magnetic and Velocity Field Measurement System, and the Solar Optical Universal Polarimeter. Additional experiments include observations with a small He-cooler IR telescope, Hard X-ray imaging of galaxy clusters and extended X-ray sources, the composition and energy spectra of cosmic ray nuclei, and the properties of superfluid He in zero gravity.

Urban, Eugene W.↗

Alterations in Cardiovascular Regulation and Function During Long-Term Simulated Microgravity

The Cardiovascular Alterations Team is conducting studies of hemodynamic regulation and susceptibility to arrhythmias resulting from sixteen days of simulated microgravity exposure. In these studies very intensive measurements are made during a short duration of bed rest. In this collaborative effort are making many of the same measurements, however much less frequently, on subjects who are exposed to a much longer duration of simulated microgravity. Alterations in cardiovascular regulation and function that occur during and after space flight have been reported. These alterations are manifested, for example, by reduced orthostatic tolerance upon reentry to the earth's gravity from space. However, the precise physiologic mechanisms responsible for these alterations remain to be fully elucidated. Perhaps, as a result, effective countermeasures have yet to be developed. In addition, numerous reports from the past 30 years suggest that the incidence of ventricular arrhythmias among astronauts is increased during space flight. However, the effects of space flight and the associated physiologic stresses on cardiac conduction processes are not known, and an increase in cardiac susceptibility to arrhythmias has never been quantified. In this project we are applying the most powerful technologies available to determine, in a ground-based study of long duration space flight, the mechanisms by which space flight affects cardiovascular function, and then on the basis of an understanding of these mechanisms to develop rational and specific countermeasures. To this end we are conducting a collaborative project with the Bone Demineralization/Calcium Metabolism Team of the National Space Biomedical Research Institute (NSBRI). The Bone Team is conducting bed rest studies in human subjects lasting 17 weeks, which provides a unique opportunity to study the effects of long duration microgravity exposure on the human cardiovascular system. We are applying a number of powerful new methods to these long term bed rest subjects, including cardiovascular system identification (CSI), microvolt level T wave alternans analysis, and cardiac magnetic resonance imaging to assess non-invasively the effects of simulated long duration space flight on the cardiovascular system.

Cohen, Richard J.↗

X-ray linear dichroic ptychography

Biominerals such as seashells, coral skeletons, bone, and tooth enamel are optically anisotropic crystalline materials with unique nanoscale and microscale organization that translates into exceptional macroscopic mechanical properties, providing inspiration for engineering new and superior biomimetic structures. Using Seriatopora aculeata coral skeleton as a model, here, we experimentally demonstrate X-ray linear dichroic ptychography and map the c-axis orientations of the aragonite (CaCO 3 ) crystals. Linear dichroic phase imaging at the oxygen K-edge energy shows strong polarization-dependent contrast and reveals the presence of both narrow (<35°) and wide (>35°) c-axis angular spread in the coral samples. These X-ray ptychography results are corroborated by four-dimensional (4D) scanning transmission electron microscopy (STEM) on the same samples. Evidence of co-oriented, but disconnected, corallite subdomains indicates jagged crystal boundaries consistent with formation by amorphous nanoparticle attachment. We expect that the combination of X-ray linear dichroic ptychography and 4D STEM could be an important multimodal tool to study nano-crystallites, interfaces, nucleation, and mineral growth of optically anisotropic materials at multiple length scales.

4D scanning transmission electron microscopy↗

Experimental Observations of Damage States in Unnotched and Notched 3D Orthogonal Woven Coupons Loaded in Tension

This paper describes a series of unnotched and notched tensile tests on two 3D orthogonal woven architectures. Dog bone specimens were used for the unnotched tests, and open-hole specimens were used for the notched tests. For each architecture and test type, two specimens were loaded under monotonic displacement control to failure and two specimens were incrementally loaded to failure in five steps. X-ray computed tomography (CT) was used to characterize the woven architecture and defects on each specimen prior to testing. Digital image correlation (DIC) images were obtained from both sides of the specimen throughout the loading and unloading. Acoustic emission (AE) data were also continuously acquired throughout the loading. For the incremental tests, X-ray CT was used to document the damage progression after each load increment. The damage progression was analyzed based on the results from these three techniques. The results for both architectures and test specimens followed a pattern where matrix cracks formed at the surface perpendicular to the tensile load direction. New surface cracks formed continuously throughout the loading and cracks extended in depth and width. In general, fiber failure was not detected until specimen failure.

Wade C Jackson↗

The use of subchondral bone topography to approximate the center of rotation of the elbow joint in dogs

Abstract Objectives The aim of this study was to compare the approximate center of rotation in normal and diseased elbows in dogs. Study design Cross‐sectional study Sample population Computer tomography scans of nine dogs with unilateral fragmented medial coronoid process (FMCP). Methods A board certified radiologist confirmed that each dog had unilateral FMCP, and a normal contralateral elbow. Digital 3D models of all elbow joints were uploaded into a surgical planning software package. Four axes approximating the center of rotation (COR) of elbow joints were generated using five geometric shapes based on subchondral topography of the humeral condyle radius and ulna. Images showing the locations where axes exited the medial and lateral cortex of the humeral condyle were captured and imported into a second software package, for measurement of distances between exit points and the origin of a system of axes. Results In normal joints 20/27 (74%) axes exited the medial cortex, and 25/27 (93%) axes exited the lateral cortex cranial and distal to the medial and lateral epicondyles, respectively. In diseased joints 22/27 (81%) axes exited medial cortex and 19/27 (70%) axes exited the lateral cortex, caudal and distal to the medial and lateral epicondyles, respectively. Conclusion Based on CT‐ derived geometry, the COR of elbow affected with FMCP was generally more caudal than normal. Clinical significance External landmarks approximating the location of the elbow COR are provided, and while not validated, may assist in planning, creation, and assessment of procedures for FMCP.

Berger, Chen↗

Battling Brittle Bones

The accuDEXA(R) Bone Mineral Density Assessment System, manufactured by Schick Technologies, Inc., utilizes "camera on a chip" sensor technology invented and developed by NASA's Jet Propulsion Laboratory. Schick's accuDEXA system offers several advantages over traditional osteoporosis tests, which assess bone density loss in the hip and spine, and require specialized personnel to conduct. With accuDEXA, physicians can test the entire body's bone density at a peripheral site, such as the finger, without applying gels or having patients remove garments. Results are achieved in 30 seconds and printed out in less than a minute, compared to the estimated exam time of 15 minutes for hip and spine density analyses. Schick has also applied the CMOS APS technology to a new software product that performs dental radiography using up to 90 percent less radiation exposure than conventional X-rays. Called Computed Dental Radiography(R), the new digital imaging product utilizes an electronic sensor in place of X-ray film to generate sharp and clear images that appear on a computer screen within 3 seconds, and can be enlarged and enhanced to identify problems.

Source record↗

Latent bone modelling for estimation of plutonium concentration in skeleton of former nuclear workers

Abstract The skeleton is a major plutonium retention site in the human body. Estimation of the total plutonium activity in the skeleton is a challenging problem. For most tissue donors at the United States Transuranium and Uranium Registries, a limited number of bone samples is available. The skeleton activity is calculated using plutonium activity concentration (Cskel) and skeleton weight. In this study, latent bone modelling was used to estimate Cskel from the limited number of analysed bone samples. Data from 13 non-osteoporotic whole-body donors were used to develop latent bone model (LBM) to estimate Cskel for seven cases with four to eight analysed bone samples. LBM predictions were compared to Cskel estimated using an arithmetic mean in terms of accuracy and precision. For the studied cases, LBM offered a significant reduction of uncertainty of Cskel estimate.

Environmental Sciences & Ecology↗

An Accurate and Dynamic Computer Graphics Muscle Model

A computer based musculo-skeletal model was developed at the University in the departments of Mechanical and Biomedical Engineering. This model accurately represents human shoulder kinematics. The result of this model is the graphical display of bones moving through an appropriate range of motion based on inputs of EMGs and external forces. The need existed to incorporate a geometric muscle model in the larger musculo-skeletal model. Previous muscle models did not accurately represent muscle geometries, nor did they account for the kinematics of tendons. This thesis covers the creation of a new muscle model for use in the above musculo-skeletal model. This muscle model was based on anatomical data from the Visible Human Project (VHP) cadaver study. Two-dimensional digital images from the VHP were analyzed and reconstructed to recreate the three-dimensional muscle geometries. The recreated geometries were smoothed, reduced, and sliced to form data files defining the surfaces of each muscle. The muscle modeling function opened these files during run-time and recreated the muscle surface. The modeling function applied constant volume limitations to the muscle and constant geometry limitations to the tendons.

Levine, David Asher↗

Melt-Pool Dynamics and Microstructure of Mg Alloy WE43 under Laser Powder Bed Fusion Additive Manufacturing Conditions

Magnesium-based alloy WE43 is a state-of-the-art bioresorbable metallic implant material. There is a need for implants with both complex geometries to match the mechanical properties of bone and refined microstructure for controlled resorption. Additive manufacturing (AM) using laser powder bed fusion (LPBF) presents a viable fabrication method for implant applications, as it offers near-net-shape geometrical control, allows for geometry customization based on an individual patient, and fast cooling rates to achieve a refined microstructure. In this study, the laser–alloy interaction is investigated over a range of LPBF-relevant processing conditions to reveal melt-pool dynamics, pore formation, and the microstructure of laser-melted WE43. In situ X-ray imaging reveals distinct laser-induced vapor depression morphology regimes, with minimal pore formation at laser-scan speeds greater than 500 mm/s. Optical and electron microscopy of cross-sectioned laser tracks reveal three distinct microstructural regimes that can be controlled by adjusting laser-scan parameters: columnar, dendritic, and banded microstructures. These regimes are consistent with those predicted by the analytic solidification theory for conduction-mode welding, but not for keyhole-mode tracks. The results provide insight into the fundamental laser–material interactions of the WE43 alloy under AM-processing conditions and are critical for the successful implementation of LPBF-produced WE43 parts in biomedical applications.

36 MATERIALS SCIENCE↗

NASA Tech Briefs, September 2006

Topics covered include: Improving Thermomechanical Properties of SiC/SiC Composites; Aerogel/Particle Composites for Thermoelectric Devices; Patches for Repairing Ceramics and Ceramic- Matrix Composites; Lower-Conductivity Ceramic Materials for Thermal-Barrier Coatings; An Alternative for Emergency Preemption of Traffic Lights; Vehicle Transponder for Preemption of Traffic Lights; Automated Announcements of Approaching Emergency Vehicles; Intersection Monitor for Traffic-Light-Preemption System; Full-Duplex Digital Communication on a Single Laser Beam; Stabilizing Microwave Frequency of a Photonic Oscillator; Microwave Oscillators Based on Nonlinear WGM Resonators; Pointing Reference Scheme for Free-Space Optical Communications Systems; High-Level Performance Modeling of SAR Systems; Spectral Analysis Tool 6.2 for Windows; Multi-Platform Avionics Simulator; Silicon-Based Optical Modulator with Ferroelectric Layer; Multiplexing Transducers Based on Tunnel-Diode Oscillators; Scheduling with Automated Resolution of Conflicts; Symbolic Constraint Maintenance Grid; Discerning Trends in Performance Across Multiple Events; Magnetic Field Solver; Computing for Aiming a Spaceborne Bistatic- Radar Transmitter; 4-Vinyl-1,3-Dioxolane-2-One as an Additive for Li-Ion Cells; Probabilistic Prediction of Lifetimes of Ceramic Parts; STRANAL-PMC Version 2.0; Micromechanics and Piezo Enhancements of HyperSizer; Single-Phase Rare-Earth Oxide/Aluminum Oxide Glasses; Tilt/Tip/Piston Manipulator with Base-Mounted Actuators; Measurement of Model Noise in a Hard-Wall Wind Tunnel; Loci-STREAM Version 0.9; The Synergistic Engineering Environment; Reconfigurable Software for Controlling Formation Flying; More About the Tetrahedral Unstructured Software System; Computing Flows Using Chimera and Unstructured Grids; Avoiding Obstructions in Aiming a High-Gain Antenna; Analyzing Aeroelastic Stability of a Tilt-Rotor Aircraft; Tracking Positions and Attitudes of Mars Rovers; Stochastic Evolutionary Algorithms for Planning Robot Paths; Compressible Flow Toolbox; Rapid Aeroelastic Analysis of Blade Flutter in Turbomachines; General Flow-Solver Code for Turbomachinery Applications; Code for Multiblock CFD and Heat-Transfer Computations; Rotating-Pump Design Code; Covering a Crucible with Metal Containing Channels; Repairing Fractured Bones by Use of Bioabsorbable Composites; Kalman Filter for Calibrating a Telescope Focal Plane; Electronic Absolute Cartesian Autocollimator; Fiber-Optic Gratings for Lidar Measurements of Water Vapor; Simulating Responses of Gravitational-Wave Instrumentation; SOFTC: A Software Correlator for VLBI; Progress in Computational Simulation of Earthquakes; Database of Properties of Meteors; Computing Spacecraft Solar-Cell Damage by Charged Particles; Thermal Model of a Current-Carrying Wire in a Vacuum; Program for Analyzing Flows in a Complex Network; Program Predicts Performance of Optical Parametric Oscillators; Processing TES Level-1B Data; Automated Camera Calibration; Tracking the Martian CO2 Polar Ice Caps in Infrared Images; Processing TES Level-2 Data; SmaggIce Version 1.8; Solving the Swath Segment Selection Problem; The Spatial Standard Observer; Less-Complex Method of Classifying MPSK; Improvement in Recursive Hierarchical Segmentation of Data; Using Heaps in Recursive Hierarchical Segmentation of Data; Tool for Statistical Analysis and Display of Landing Sites; Automated Assignment of Proposals to Reviewers; Array-Pattern-Match Compiler for Opportunistic Data Analysis; Pre-Processor for Compression of Multispectral Image Data; Compressing Image Data While Limiting the Effects of Data Losses; Flight Operations Analysis Tool; Improvement in Visual Target Tracking for a Mobile Robot; Software for Simulating Air Traffic; Automated Vectorization of Decision-Based Algorithms; Grayscale Optical Correlator Workbench; "One-Stop Shopping" for Ocean Remote-Sensing and Model Data; State Analysis Database Tool; Generating CAHV and CAHVOmages with Shadows in ROAMS; Improving UDP/IP Transmission Without Increasing Congestion; FORTRAN Versions of Reformulated HFGMC Codes; Program for Editing Spacecraft Command Sequences; Flight-Tested Prototype of BEAM Software; Mission Scenario Development Workbench; Marsviewer; Tool for Analysis and Reduction of Scientific Data; ASPEN Version 3.0; Secure Display of Space-Exploration Images; Digital Front End for Wide-Band VLBI Science Receiver; Multifunctional Tanks for Spacecraft; Lightweight, Segmented, Mostly Silicon Telescope Mirror; Assistant for Analyzing Tropical-Rain-Mapping Radar Data; and Anion-Intercalating Cathodes for High-Energy- Density Cells.

Source record↗

Effect of Ex Vivo Ionizing Radiation on Static and Fatigue Properties of Mouse Vertebral Bodies

For a variety of medical and scientific reasons, human bones can be exposed to a wide range of ionizing radiation levels. In vivo radiation therapy (0.05 kGy) is used in cancer treatment, and ex vivo irradiation (25-35 kGy) is used to sterilize bone allografts. Ionizing radiation in these applications has been shown to increase risk of fracture, decrease bone quality and degrade collagen integrity. Past studies have investigated the deleterious effects of radiation on cortical or trabecular bone specimens individually, but to date no studies have examined whole bones containing both cortical and trabecular tissue. Furthermore, a clear relationship between the dose and the mechanical and biochemical response of bone's extracellular matrix has yet to be established for doses ranging from cancer therapy to allograft sterilization (0.05-35 kGy). To gain insight into these issues, we conducted an ex vivo radiation study to investigate non-cellular (i.e. matrix) effects of ionizing radiation dose on vertebral whole bone mechanical properties, over a range of radiation doses (0.05-35 kGy), with a focus on any radiation-induced changes in collagen. With underlying mechanisms of action in mind, we hypothesized that any induced reductions in mechanical properties would be associated with changes in collagen integrity. METHODS: 20-week old female mice were euthanized and the lumbar spine was dissected using IACUC approved protocols. The lumbar vertebrae (L1- S1) were extracted from the spine via cuts through adjacent intervertebral discs, and the endplates, posterior processes, surrounding musculature, and soft tissues were removed (approx. 1.5mm diameter, approx. 2mm height). Specimens were randomly assigned to one of five groups for ex vivo radiation exposure: x-ray irradiation at 0.05, 1, 17, or 35 kGy, or a 0 kGy control. Following irradiation, the vertebrae were imaged using microcomputed tomography (micro-CT) and then subjected to either monotonic compressive loading to failure or uniform cyclic compressive loading. During cyclic testing, samples were loaded in force control to a force level that corresponded to a strain of 0.46%, as determined in advance by a linearly elastic micro-CT-based finite element analysis for each specimen. Tests were stopped at imminent fracture, defined as a rapid increase in strain. The main outcome for the monotonic test was the strength (maximum force); for cyclic testing it was the fatigue life (log of the number of cycles of loading at imminent failure). A fluorometric assay was used on the S1 vertebrae to measure the number of non-enzymatic collagen crosslinks[4]. A one-way ANOVA was performed on mechanical properties and collagen crosslinks; means were compared with controls using Dunnett's method, with a Tukey-Kramer post-hoc analysis when significance was found (p < or = 0.05). RESULTS: Compared to the unirradiated control group, the concentration of non-enzymatic collagen crosslinks was significantly increased for all irradiated groups (p < 0.0001), and being higher by at least 50% (Figure 1a). By contrast, the radiation effects on the collagen were only evident at the higher doses. For irradiation exposures of 17 kGy or more, strength decreased substantially as the radiation level was increased, but no effect was evident below 17 kGy (Figure 1b). There was no significant change in the stiffness or maximum displacement for any radiation dose (p>0.05). The finite element analysis prescribed force level for cyclic loading exceeded the measured (monotonic) strength of the 17 and 35 kGy irradiated groups (mean +/- SD, 20.6 +/- 5.6 N; 13.2 +/- 3.7 N, respectively) and therefore these groups were eliminated from the fatigue study. The fatigue life for the 0.05 and 1 kGy groups were similar to each other and were not statistically significantly different from the control group (Figure 1c).

radiation↗

Comparison and calibration of dose delivered by 137 Cs and x-ray irradiators in mice

Objective. The Office of Radiological Security, U.S. Department of Energy's National Nuclear Security Administration, is implementing a radiological risk reduction program which seeks to minimize or eliminate the use of high activity radiological sources, including 137 Cs, by replacing them with non-radioisotopic technologies, such as x-ray irradiators. The main goal of this paper is to evaluate the equivalence of the dose delivered by gamma- and x-ray irradiators in mice using experimental measurements and Monte Carlo simulations. We also propose a novel biophantom as an in situ dose calibration method. Approach. We irradiated mouse carcasses and 3D-printed mouse biophantoms in a 137 Cs irradiator (Mark I-68) and an x-ray irradiator (X-Rad320) at three voltages (160 kVp, 225 kVp and 320 kVp) and measured the delivered radiation dose. A Geant4-based Monte Carlo model was developed and validated to provide a comprehensive picture of gamma- and x-ray irradiation in mice. Main Results. Our Monte Carlo model predicts a uniform dose delivered in soft-tissue for all the explored irradiation programs and in agreement with the absolute dose measurements. Our Monte Carlo model shows an energy-dependent difference between dose in bone and in soft tissue that decreases as photon energy increases. Dose rate depends on irradiator and photon energy. We observed a deviation of the measured dose from the target value of up to –9% for the Mark I-68, and up to 35% for the X-Rad320. The dose measured in the 3D-printed phantoms are equivalent to that in the carcasses within 6% uncertainty. Significance. Our results suggest that 320 kVp irradiation is a good candidate to substitute 137 Cs irradiation barring a few caveats. There is a significant difference between measured and targeted doses for x-ray irradiation that suggests a strong need for in situ calibration, which can be achieved with 3D-printed mouse biophantoms. A dose correction is necessary for bone doses, which can be provided by a Monte Carlo calculation. Lastly, the biological implications of the differences in dose rates and dose per photon for the different irradiation methods should be carefully assessed for each small-animal irradiation experiment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pilot Study on the Investigation of Tear Fluid Biomarkers as an Indicator of Ocular, Neurological, and Immunological Health in Astronauts

The purpose of this pilot study is to investigate the collection, preparation, and analysis of tear biomarkers as a means of assessing ocular, neurological, and immunological health. At present, no published data exists on the cytokine profiles of tears from astronauts exposed to long periods of microgravity and space irradiations. In addition, no published data exist on cytokine (biomarker) profiles of tears that have been collected from irradiated non-human biological systems (primates and other animal models). A goal for the proposed pilot study is to discover novel tear biomarkers which can help inform researchers, clinicians, epidemiologist and healthcare providers about the health status of a living biological system, as well as informing them when a disease state is triggered. This would be done via analysis of the onset of expression of pro-inflammatory cytokines, leading up to the full progression of a disease (i.e. cancer, loss of vision, radiation-induced oxidative stress, cardiovascular disorders, fibrosis in major organs, bone loss). Another goal of this pilot study is to investigate the state of disease against proposed medical countermeasures, in order to determine whether the countermeasures are efficacious in preventing or mitigating these injuries. An example of an up and coming tear biomarker technology, Ascendant Dx, a clinical stage diagnostic company, is developing a screening test to detect breast cancer using proteins from tears. The team utilized Liquid Chromatography -Mass Spectrometry with Mass analysis (LC MS/MS) as a discovery platform followed by validation with ELISA to come up with a panel of protein biomarkers that can differentiate breast cancer samples from control ("cancer free") samples with results far surpassing the results of imaging techniques in use today. Continued research into additional proteins is underway to increase the sensitivity and specificity of the test and development efforts are on the way to transfer the test onto a fast, accurate and inexpensive point of care platform. In conclusion, the expected results from this proposed pilot study are to: a) establish an SOP for retrieving/storing/transporting tear fluid samples from multicentre sites b) establish a normal range for relevant biomarkers in tears; and c) establish a database (biobank) of tears of space naïve versus veteran astronauts, to establish a personal baseline for long-term ocular health monitoring

Morton, Stephen↗

Digital image correlation and infrared thermography data for seven unique geometries of 304L stainless steel

Material Testing 2.0 (MT2.0) is a paradigm that advocates for the use of rich, full-field data, such as from digital image correlation and infrared thermography, for material identification. By employing heterogeneous, multi-axial data in conjunction with sophisticated inverse calibration techniques such as finite element model updating and the virtual fields method, MT2.0 aims to reduce the number of specimens needed for material identification and to increase confidence in the calibration results. To support continued development, improvement, and validation of such inverse methods—specifically for rate-dependent, temperature-dependent, and anisotropic metal plasticity models—we provide here a thorough experimental data set for 304L stainless steel sheet metal. The data set includes full-field displacement, strain, and temperature data for seven unique specimen geometries tested at different strain rates and in different material orientations. Commensurate extensometer strain data from tensile dog bones is provided as well for comparison. We believe this complete data set will be a valuable contribution to the experimental and computational mechanics communities, supporting continued advances in material identification methods.

36 MATERIALS SCIENCE↗

Cross-calibration of liquid and solid QCT calibration standards: corrections to the UCSF normative data

Quantitative computed tomography (QCT) has been shown to be a precise and sensitive method for evaluating spinal bone mineral density (BMD) and skeletal response to aging and therapy. Precise and accurate determination of BMD using QCT requires a calibration standard to compensate for and reduce the effects of beam-hardening artifacts and scanner drift. The first standards were based on dipotassium hydrogen phosphate (K2HPO4) solutions. Recently, several manufacturers have developed stable solid calibration standards based on calcium hydroxyapatite (CHA) in water-equivalent plastic. Due to differences in attenuating properties of the liquid and solid standards, the calibrated BMD values obtained with each system do not agree. In order to compare and interpret the results obtained on both systems, cross-calibration measurements were performed in phantoms and patients using the University of California San Francisco (UCSF) liquid standard and the Image Analysis (IA) solid standard on the UCSF GE 9800 CT scanner. From the phantom measurements, a highly linear relationship was found between the liquid- and solid-calibrated BMD values. No influence on the cross-calibration due to simulated variations in body size or vertebral fat content was seen, though a significant difference in the cross-calibration was observed between scans acquired at 80 and 140 kVp. From the patient measurements, a linear relationship between the liquid (UCSF) and solid (IA) calibrated values was derived for GE 9800 CT scanners at 80 kVp (IA = [1.15 x UCSF] - 7.32).(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Program Space Physiology and Countermeasures↗

Impact of Acid–Base Stimulation Sequence on Mineral Stability for Tight/Impermeable Unconventional Carbonate-Rich Rocks: A Delaware Basin Case Study

We report mineral precipitation due to reactions with injected fluids during unconventional fracture stimulation is a well-recognized problem. The goal of this study is to evaluate secondary mineral precipitation and permeability attenuation under chemical injection scenarios specific to the Delaware basin. Whole cylindrical cores (2.54 cm diameter and 2.54 cm height) and ground shale (150–250 μm) from the carbonate-rich Bone Spring Formation, Delaware Basin TX (Leonardian), were reacted at 80 °C and 85 bar using a hydraulic fracturing fluid (HFF) recipe and an injection sequence typical of the Delaware Basin. The reacted shales and solutions were analyzed using a variety of laboratory- and synchrotron-based techniques to characterize both the chemical and spatial distributions of secondary mineral precipitation and identify changes in permeability and mineralogy. This carbonate-rich shale (>84% calcite) rapidly neutralized the acidic HFF. Synchrotron-based X-ray fluorescence mapping coupled with X-ray absorption spectroscopy (both bulk and micro) showed that most of the iron was in an oxidized form prior to exposure to HFF and that almost all iron(II) became fully oxidized after the reaction. Scanning electron microscopy images of the ground shale samples primarily identified iron(oxyhydr)oxide microcrystals on grain surfaces. A few small isolated iron-rich areas also contained sulfur, suggesting that some pyrite was preserved when isolated within a calcite crystal but that most was oxidized. The rapid neutralization of the acid spearhead in these carbonate-rich samples demonstrates that the acid spearhead is useful for initiating fractures in extremely calcite-rich rocks but does little to enhance rock permeability. This suggests that the impact of the acid spearhead is significantly smaller for carbonate-rich shales compared to clay-rich shales, which has broad implications for acidizing in carbonate-rich shale formations and iron transformations within these shales.

58 GEOSCIENCES↗