Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Body Height”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Pickup Ion Distributions from Three Dimensional Neutral Exospheres

Pickup ions formed from ionized neutral exospheres in flowing plasmas have phase space distributions that reflect their source's spatial distributions. Phase space distributions of the ions are derived from the Vlasov equation with a delta function source using three.dimensional neutral exospheres. The ExB drift produced by plasma motion picks up the ions while the effects of magnetic field draping, mass loading, wave particle scattering, and Coulomb collisions near a planetary body are ignored. Previously, one.dimensional exospheres were treated, resulting in closed form pickup ion distributions that explicitly depend on the ratio rg/H, where rg is the ion gyroradius and H is the neutral scale height at the exobase. In general, the pickup ion distributions, based on three.dimensional neutral exospheres, cannot be written in closed form, but can be computed numerically. They continue to reflect their source's spatial distributions in an implicit way. These ion distributions and their moments are applied to several bodies, including He(+) and Na(+) at the Moon, H(+2) and CH(+4) at Titan, and H+ at Venus. The best places to use these distributions are upstream of the Moon's surface, the ionopause of Titan, and the bow shock of Venus.

Hartle, R. E.↗

Risk Factors for Neovascular Glaucoma After Proton Beam Therapy of Uveal Melanoma: A Detailed Analysis of Tumor and Dose–Volume Parameters

Purpose: To determine neovascular glaucoma (NVG) incidence and identify contributing tumor and dosing factors in uveal melanoma patients treated with proton beam radiation therapy (PBRT). Methods and Materials: A total of 704 PBRT patients treated by a single surgeon (DHC) for uveal melanoma (1996-2010) were reviewed for NVG in our prospectively maintained database. All patients received 56 GyE in 4 fractions. Median follow-up was 58.3 months. Analyses included the Kaplan-Meier method to estimate NVG distributions, univariate log–rank tests, and Cox's proportional hazards multivariate analysis using likelihood ratio tests to identify independent risk factors of NVG among patient, tumor, and dose–volume histogram parameters. Results: The 5-year PBRT NVG rate was 12.7% (95% confidence interval [CI] 10.2%-15.9%). The 5-year rate of enucleation due to NVG was 4.9% (95% CI 3.4%-7.2%). Univariately, the NVG rate increased significantly with larger tumor diameter (P<.0001), greater height (P<.0001), higher T stage (P<.0001), and closer proximity to the disc (P=.002). Dose–volume histogram analysis revealed that if >30% of the lens or ciliary body received ≥50% dose (≥28 GyE), there was a higher probability of NVG (P<.0001 for both). Furthermore, if 100% of the disc or macula received ≥28 GyE, the NVG rate was higher (P<.0001 and P=.03, respectively). If both anterior and posterior doses were above specified cut points, NVG risk was highest (P<.0001). Multivariate analysis confirmed significant independent risk factors to include tumor height (P<.0001), age (P<.0001), %disc treated to ≥50% Dose (<100% vs 100%) (P=.0007), larger tumor diameter (P=.01), %lens treated to ≥90% Dose (0 vs >0%-30% vs >30%) (P=.01), and optic nerve length treated to ≥90% Dose (≤1 mm vs >1 mm) (P=.02). Conclusions: Our current PBRT patients experience a low rate of NVG and resultant enucleation compared with historical data. The present analysis shows that tumor height, diameter, and anterior as well as posterior critical structure dose–volume parameters may be used to predict NVG risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Resource Prospector Neutron Spectrometer System: RP's Bloodhound

The primary goal of the Resource Prospector Neutron Spectrometer System (NSS) is to locate and characterize hydrogen-bearing volatile deposits, especially subsurface ice, that may exist at the lunar poles. A key objective is to detect water-equivalent hydrogen concentrations of 0.5 wt% or greater while on a moving rover. A second objective is to determine approximate burial depth of enhanced hydrogen-bearing materials up to 1 meter below otherwise dry regolith. The instrument will be carried aboard a landed mobility system at the lunar poles. The instrument operates by measuring the changes in the leakage flux of low energy neutrons out of the regolith. These neutrons are produced by galactic cosmic rays, which are so energetic that they shatter the nuclei in surface materials. The neutrons interact with other nuclei and lose energy, becoming thermalized in the process. Hydrogen is most efficient at thermalizing neutrons owing to protons' similar mass - statistically, neutrons lose half their energy per collision with protons. With hydrogen in the soil, leakage fluxes of neutrons in the 0.5 eV to 500 keV energy range are reduced. A concentration of only1-2 wt% water-equivalent hydrogen results in a decrease in epithermal leakage flux of a factor of two. The leakage flux of thermal neutrons, from 0 to 0.5 eV in energy, can either increase or decrease depending on the hydrogen abundance and stratigraphy. As with the highly successful Lunar Prospector Neutron Spectrometer, the RP NSS detects both thermal and epithermal neutrons by using two helium-3 gas proportional counters, one covered by cadmium and the other uncovered. The former detects only epithermal neutrons with energies above approximately 0.5 eV, the latter detects both thermal (less than 0.5 eV) and epithermal energies (greater than 0.5 eV). When a neutron enters the detector tube and interacts with a helium-3 nucleus, the resulting reaction produces an energetic proton and triton that ionize the gas. The resulting electrons are accelerated toward a high-voltage anode and cascade, amplifying the net charge, which is collected at the anode. The number of electrons produced is proportional to the energy that the triton and proton deposit in the gas. A charge sensitive pre-amplifier converts the total charge to a step voltage output. A shaper amplifier then shapes this step into a uni-polar waveform with peaking time appropriate for the detection depending on the event rate. The integrated shaped waveform, representing the deposited triton/proton energy, is then measured. A histogram, or pulse height analysis, is performed to record the main capture peak and wall effect pulses. A threshold for detection is also required to limit the low amplitude counting rate such as noise floor. The system electronics consists of 2 modules - the Sensor Module (SM) front-end and the Data Processing Module (DPM) back-end circuits. SM is designed as a light-weight and low power front-end housing the two helium-3 proportional counter detectors, preamp and HVPS. It is mounted external to the rover body to detect the thermalized neutron flux with a minimum of host background. The DPM is located inside the rover; it digitizes the SM signals, performs pulse height analysis and accumulates the count rate for each spectral channel. The DPM controls high voltage and thresholding, and sends the science data to the host craft via an RS422 serial asynchronous protocol. The payload host provides all thermal management and control for the SM and DPM.

hydrogen-bearing volatile deposits↗

Overshooting cloud top, variation of tropopause and severe storm formation

The development of severe multicell thunderstorms leading to the touchdown of six tornados near Pampa, TX, on May 19-20, 1982, is characterized in detail on the basis of weather maps, rawinsonde data, and radar summaries, and the results are compared with GOES rapid-scan IR images. The multicell storm cloud is shown to have formed beginning at 1945 GMT at the point of highest horizontal moisture convergence and lowest tropopause height and to have penetrated the tropopause at 2130 GMT, reaching a maximum altitude and a cloud-top black-body temperature 9 C lower than the tropopause temperature at 2245 GMT and collapsing about 20 min, when the firt tornado touched down. The value of the real-time vertical profiles provided by satellite images in predicting which severe storms will produce tornados or other violent phenomena is stressed.

Hung, R. J.↗

Underestimation of Deep Convective Cloud Tops by Thermal Imagery

The most common method of ascertaining cloud heights from space is from thermal brightness temperatures. Deep cumulus clouds of high water content are expected to radiate as black bodies. Here, cloud tops are estimated from several sensors: GOES-8, the Moderate Resolution Imaging Spectroradiometer (MODIS), the Moderate resolution Imaging Sensor (MISR), and the Goddard Cloud Physics Lidar (CPL), all collected during the CRYSTAL Florida Area Cirrus Experiment (CRYSTAL-FACE). Thermally derived cloud tops are consistently approx. 1km too low compared with independent measurements, no matter how thick the clouds are, even when the finite optical extinctions near cloud top and in thin overlying cirrus are taken into account. The bias appears to get worse for the tallest clouds. Cloud material is often present 2 km or more above the apparent cloud top. This mysterious discrepancy appears to be satellite-independent.

Sherwood, Steven C.↗

3D Scanning System to Assess Gravity-Dependent Body Shape Changes

The human body shows unique morphological changes when exposed to different gravity conditions, including muscle atrophy, fluid shift, and spinal elongation. Such changes need to be incorporated for human-system integration in the vehicle habitat, garment, and spacesuit designs, as inaccurate body measurements can result in suboptimal crew protection that can potentially decrease injury tolerance. However, measurement tools have not been available for accurate assessments of body shape changes. This work aimed to develop a prototype 3-D body scanning system with the configuration and performance optimized for in-flight crewmember body scanning. A scan hardware system was developed using Intel RealSense commercial off-the-shelf 3D sensors. The sensor parameters were iteratively optimized and tested to obtain the performance level needed for body scanning. A scan booth structure was fabricated, with the overall size 4 x 4 x 8 feet. The specific number of sensors and mounting positions were determined by iterative simulations, which indicated that 16 cameras can capture 94% and 96% of body surface area from the 1st percentile female and 99th percentile male crew population subject. The mounted sensors were linked through a mix of USB-C and USB-3 cables and operated for data acquisition from a Linux laptop computer. A software prototype was developed using Python and Tkinter graphical user interface toolkit. A calibration procedure was also built using a panel of QR codes. A computer vision tool detected and decoded the unique ID and pattern locations of the QR codes. The calibration information determined the position and orientation of the 3D sensors with respect to each other. The scanner performance was assessed using a set of 3D printed custom manikins. The manikin size and shape were derived from the previous ISS study, which measured the crewmembers’ anthropometry changes across the different flight phases. The average anthropometric measurements at the pre-flight and flight day 15 were sampled and projected onto the 1st percentile female and 99th percentile male body shapes. Another pair of manikins were also 3D printed to simulate the neutral body posture, estimated from ISS microgravity environments. A preliminary analysis assessed the performance of the newly developed scanner against the reference scanner, which has been used at the NASA JSC for crew and test subject anthropometry. Although the new scanner data showed several artifacts and missing geometries in the occluded body areas such as armpits and crotch, overall shape matched with the reference scan. When the manikin surface coordinates were compared, a root mean square error of 1.3 cm was observed from the manikin torso segment. Linear measurements including the stature, knee height and circumference measurements at the chest and calf showed differences from the reference scan measurements, ranging between 0.3 and 0.9 cm. Overall, this work demonstrated a development framework for an in-flight scanner with design and operation optimized for crewmember body scanning. Further improvement can potentially provide previously unavailable anthropometric data from different gravitational environments, including 0-g, 1/6-g, and 1-g. Such data can improve suit fit, habitat design, exercise efficacy quantification and sizing of orthostatic intolerance garments.

K H Kim↗

SU-F-T-82: Dosimetric Evaluation of a Shield Used for Hemi-Body Skin Electron Irradiation

Purpose: We had several mycosis fungoides patients with a limited disease to about half of the skin surface. A custom-made plywood shield was used to protect the non-targeted skin region with our total skin electron irradiation (TSEI) technique. We report a dosimetric evaluation for our “hemi-body” skin electron irradiation technique. Methods: The technique is similar to our clinical total skin electron irradiation (TSEI), performed with a six-pair dual field (Stanford technique) at an extended source-to-skin distance (SSD) of 377 cm, with the addition of a plywood shield placed 50 cm from the patient. The shield is made of three layers of standard 5/8″ thick plywood (total thickness of 4.75 cm) that are clamped securely on an adjustable-height stand. Gafchromic EBT3 films were used in assessing the shield’s transmission factor and the extend of the dose penumbra region. To verify the dose delivered for hemi-body skin radiation in a real patient treatment, in-vivo dosimetry using Gafchromic EBT3 films were performed. Film pieces were taped on the patient skin to measure the dose received during the first two fractions, placed on the forehead and upper body (shielded region); and also at the level of pelvic area, left thigh, and left ankle. Results: The shield transmission factor was found to be 10%, and the width of the penumbra (80-to-20% dose fall-off) was about 12 cm. In-vivo dosimetry of a real case confirmed the expected shielded area dose. Conclusion: Hemi-Body skin electron irradiation at an extended SSD is feasible with the addition of a plywood shield at a distance from patient skin. The penumbra dose region and the shield’s transmission factor should be evaluated prior to clinical use. We have treated several hemi-body skin patients with our custom-made plywood shield, the current patient measurements are representative of these for other patients as well.

60 APPLIED LIFE SCIENCES↗

A wearable sensor based on CLYC scintillators

We developed a wearable radiation sensor using Cs 2 LiYCl 6 :Ce (CLYC) for simultaneous gamma-ray and neutron detection. The system includes two ø2.5×2.5 cm 3 crystals coupled to small, metal-body photomultiplier tubes. A custom, low-power electronics base digitizes the output signal at three time points and enables both pulse height and pulse shape discrimination of neutrons and gamma-rays. Data, including spectra, can be transferred via a wired or wireless connection. The total gamma-ray and neutron counts, anomaly detection metrics, and identified isotopes are displayed on a small screen on the device. Users may leave the system in unattended mode to collect long-dwell energy spectra. The prototype system has overall dimensions of 13×7.5×18 cm 3 and weight of 1.3 kg, not including the protective pouch, and runs on six AA alkaline batteries for 29 hours with a 1% wireless transmission duty cycle and 41 hours with the wireless turned off . In this paper, we summarize the system design and present characterization results from the detector modules. The energy resolution is about 6.5% full width at half maximum at 662 keV due to the small photomultiplier tube selected, and the linearity and pulse shape discrimination performance are very good.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of Aerothermodynamic and Boundary-Layer Transition Testing of 0.0362-Scale X-38 (Rev. 3.1) Vehicle in NASA Langley 20-Inch Mach 6 Tunnel

The aeroheating characteristics of the X-38 Revision 3.1 lifting-body configuration have been experimentally examined in the Langley 20-inch Mach 6 Tunnel. Global surface heat transfer distributions, surface streamline patterns, and shock shapes were measured on a 0.0362-scale model of a proposed Space Station Crew Return Vehicle at Mach 6 in air. Parametric variations include angles-of-attack of 20 deg, 30 deg, and 40 deg; Reynolds numbers based on model length of 0.9 to 3.7 million; and body-flap deflections of O deg, 20 deg, 25 deg, and 30 deg. The effects of discrete roughness elements, which included trip height, location, size, and orientation, as well as multiple-trip parametrics, were investigated. This document is intended to serve as a quick release of preliminary data to the X-38 program; analysis is limited to observations of the experimental trends in order to expedite dissemination.

Berry, Scott A.↗

X-33 (Rev-F) Aeroheating Results of Test 6770 in NASA Langley 20-Inch Mach 6 Air Tunnel

Aeroheating characteristics of the X-33 Rev-F configuration have been experimentally examined in the Langley 20-Inch Mach 6 Air Tunnel (Test 6770). Global surface heat transfer distributions, surface streamline patterns, and shock shapes were measured on a 0.013-scale model at Mach 6 in air. Parametric variations include angles-of-attack of 20-deg, 30-deg, and 40-deg; Reynolds numbers based on model length of 0.9 to 4.9 million; and body-flap deflections of 10-deg and 20-deg. The effects of discrete roughness elements on boundary layer transition, which included trip height, size, and location, both on and off the windward centerline, were investigated. This document is intended to serve as a quick release of preliminary data to the X-33 program; analysis is limited to observations of the experimental trends in order to expedite dissemination.

Berry, Scott A.↗

Initial Sensorimotor and Cardiovascular Data Acquired from Soyuz Landings: Establishing a Functional Performance Recovery Time Constant

INTRODUCTION Testing of crew responses following long-duration flights has not been previously possible until a minimum of more than 24 hours after landing. As a result, it has not been possible to determine the trend of the early recovery process, nor has it been possible to accurately assess the full impact of the decrements associated with long-duration flight. To overcome these limitations, both the Russian and U.S. programs have implemented joint testing at the Soyuz landing site. This International Space Station research effort has been identified as the functional Field Test, and represents data collect on NASA, Russian, European Space Agency, and Japanese Aerospace Exploration Agency crews. RESEARCH The primary goal of this research is to determine functional abilities associated with long-duration space flight crews beginning as soon after landing as possible on the day of landing (typically within 1 to 1.5 hours). This goal has both sensorimotor and cardiovascular elements. To date, a total of 15 subjects have participated in a 'pilot' version of the full 'field test'. The full version of the 'field test' will assess functional sensorimotor measurements included hand/eye coordination, standing from a seated position (sit-to-stand), walking normally without falling, measurement of dynamic visual acuity, discriminating different forces generated with the hands (both strength and ability to judge just noticeable differences of force), standing from a prone position, coordinated walking involving tandem heel-to-toe placement (tested with eyes both closed and open), walking normally while avoiding obstacles of differing heights, and determining postural ataxia while standing (measurement of quiet stance). Sensorimotor performance has been obtained using video records, and data from body worn inertial sensors. The cardiovascular portion of the investigation has measured blood pressure and heart rate during a timed stand test in conjunction with postural ataxia testing (quiet stance sway) as well as cardiovascular responses during sensorimotor testing on all of the above measures. We have also collected motion sickness data associated with each of the postflight tests. When possible rudimentary cerebellar assessment was undertaken. In addition to the immediate post-landing collection of data, postflight data has been acquired twice more within 24 hours after landing and measurements continue until sensorimotor and cardiovascular responses have returned to preflight normative values (approximately 60 days postflight). SUMMARY The level of functional deficit observed in the crew tested to date is more severe than expected, clearly triggered by the acquisition of gravity loads immediately after landing when the demands for crew intervention in response to emergency operations will be greatest. Measureable performance parameters such as ability to perform a seat egress, recover from a fall or the ability to see clearly when walking, and related physiologic data (orthostatic responses) are required to provide an evidence base for characterizing programmatic risks and the degree of variability among crewmembers for exploration missions where the crew will be unassisted after landing. Overall, these early functional and related physiologic measurements will allow the estimation of nonlinear sensorimotor and cardiovascular recovery trends that have not been previously captured.

Reschke, M. F.↗

Turbulence Model Validation Through Joint Experimental /Computational Studies of Separated Flow Over A Three-Dimensional Tapered Bump: Part I - Experimental Investigation

The results of a three-year experimental campaign aimed at comprehensively documenting the separated flow over a three-dimensional bump are presented with the purpose of generating a benchmark experimental database useful in validating computational fluid dynamics (CFD) flow simulations. The bump model geometry was designed to provide well-defined and repeatable smooth-body flow separation conditions that were suitable for both experiments and simulations. The bump had a Gaussian streamwise profile with a constant height equal to 8.5% of its width over the central 60% of the test section width. The remaining 40% were outboard spanwise portions that gradually taper to zero using an error function profile to minimize side-wall boundary layer effects. The model was immersed in a turbulent boundary layer that was developed on a suspended flat plate in the Notre Dame Mach 0.6 Wind Tunnel. In order to document the effect of the incoming boundary layer thickness on the flow separation, the bump model could be located at two streamwise positions. The mean velocity and turbulence intensity of the wind tunnel freestream flow field and approaching turbulent boundary layer were fully documented. The measurements of the flow separation region included surface visualization, wall shear stress using oil-film interferometry, mean and dynamic surface pressure, and planar and stereoscopic particle image velocimetry. The experiments were conducted over a range of Mach numbers from 0.05 to 0.2 corresponding to a range of Reynolds numbers based on the test section spanwise dimension (0.914m) of 1.0 × 10 6 ≤ Re L = U ∞ L/ν ≤ 4.0 × 10 6 . The bulk of the results are presented for the higher Mach number conditions of 0.1 and 0.2 with Re L = 2.0 × 10 6 and 4.0 × 10 6 , respectively. Extensive uncertainty analysis of the data was performed. The data is archived in the NASA Langley Turbulence Modeling Resource website at https://turbmodels.larc.nasa.gov/Other_exp_Data/speedbump_sep_exp.html. In addition to the experiments, a computational effort was made in parallel by the CFD group at Boeing Research & Technology highlighting the usefulness of the data set, which is outlined in the accompanying CFD report.

Flow separation↗

Machine-Learning-Based Monitoring of Laser Powder Bed Fusion

A two-step machine learning approach to monitoring Laser Powder Bed Fusion (LPBF) additive manufacturing is demonstrated that enables on-the-fly assessments of laser track welds. First, in situ video melt pool data acquired during LPBF is labeled according to the (1) average and (2) standard deviation of individual track width and also (3) whether or not the track is continuous, measured post-build through an ex situ height map analysis algorithm. This procedure generates three ground truth labeled datasets for supervised machine learning. Using a portion of the labeled 10-millisecond video clips, a single Convolutional Neural Network architecture is trained to generate three distinct networks. With the remaining in situ LPBF data, the trained neural networks are tested and evaluated and found to predict track width, standard deviation, and continuity without the need for ex situ measurements. This two-step approach should benefit any LPBF system – or any additive manufacturing technology – where height-map-derived properties can serve as useful labels for in situ sensor data.

42 ENGINEERING↗

Vibration Suppression of High-Temperature Superconducting Maglev System via Electromagnetic Shunt Damper

The high-temperature superconducting (HTS) maglev system is characterized with self-stable levitation, low energy consumption, and pollution-free operation, and it has been considered as a promising technology for implementing high-speed transport systems. But the previous studies have shown that the damping of such system is relatively low, which indicates the large-amplitude nonlinear vibration may occur easily under external disturbances and affect the long-term motion stability, operation safety, and comfort of HTS maglev in rail transit application. In order to suppress the harmful vibration, an electromagnetic shunt damper (EMSD) was designed and incorporated into the HTS maglev system. Compared with other systems which employ the EMSD to diminish the vibration, the HTS maglev system does not need to set up external devices to supply magnetic field for the damper, because the permanent magnet guideway (PMG) in this system is directly taken advantages of. The natural frequency of the damper is adjusted to a value close to that of the maglev system. In this way, the damper becomes most effective because the moving vehicle body and the circuit resonate simultaneously. The feasibility of the damper was demonstrated through systematic experiments, and the effects of different field cooling heights (FCHs) of the HTS maglev system on EMSD’s performance were experimentally studied as well. Also, how the change of resistors in the EMSD circuit affects its working efficiency was preliminarily explored in this work. The results show that under the definite external disturbance, the damper can effectively attenuate the acceleration of vibration, furthermore, and it is found that the damper works better in condition of lower FCH. Within the scope of our experiments, the EMSD with a resistor in lower resistance performs better as results have shown. This investigation indicates that the vehicle will run in a more smooth and comfortable way along the track with this damper. The work is important for the further practical application of the technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Anthropometric changes and fluid shifts

Several observations of body size, shape, posture, and configuration were made to document changes resulting from direct effects of weightlessness during the Skylab 4 mission. After the crewmen were placed in orbit, a number of anatomical and anthropometric changes occurred including a straightening of the thoracolumbar spine, a general decrease in truncal girth, and an increase in height. By the time of the earliest in-flight measurement on mission day 3, all crewmen had lost more than two liters of extravascular fluid from the calf and thigh. The puffy facies, the bird legs effect, the engorgement of upper body veins, and the reduced volume of lower body veins were all documented with photographs. Center-of-mass measurements confirmed a fluid shift cephalad. This shift remained throughout the mission until recovery, when a sharp reversal occurred; a major portion of the reversal was completed in a few hours. The anatomical changes are of considerable scientific interest and of import to the human factors design engineer, but the shifts of blood and extravascular fluid are of more consequence. It is hypothesized that the driving force for the fluid shift is the intrinsic and unopposed lower limb elasticity that forces venous blood and then other fluid cephalad.

Thornton, W. E.↗

Velocity and pressure fields associated with near-wall turbulence structures

Computer generated databases containing velocity and pressure fields in three-dimensional space at a sequence of time-steps, were used for the investigation of near-wall turbulence structures, their space-time evolution, and their associated pressure fields. The main body of the results were obtained from simulation data for turbulent channel flow at a Reynolds number of 180 (based on half-channel height and friction velocity) with a grid of 128 x 129 x and 128 points. The flow was followed over a total time of 141 viscous time units. Spanwise centering of the detected structures was found to be essential in order to obtain a correct magnitude of the associated Reynolds stress contribution. A positive wall-pressure peak is found immediately beneath the center of the structure. The maximum amplitude of the pressure pattern was, however, found in the buffer region at the center of the shear-layer. It was also found that these flow structures often reach a maximum strength in connection with an asymmetric spanwise motion, which motivated the construction of a conditional sampling scheme that preserved this asymmetry.

Johansson, Arne V.↗

Evaluation of restraint system concepts for the Japanese Experiment Module flight demonstration

The current International Space Station configuration includes a Japanese Experiment Module which relies on a large manipulator and a smaller dexterous manipulator to operate outside the pressurized environment of the experiment module. The module's flight demonstration is a payload that will be mounted in the aft flight deck on STS-87 to evaluate a prototype of the dexterous manipulator. Since the payload operations entail two 8-hour scenarios on consecutive days, adequate operator restraint at the workstation will be critical to the perceived success or failure of the payload. Simulations in reduced gravity environment on the KC-135A were the only way to evaluate the restraint systems and workstation configuration. Two astronaut and two non-astronaut operators evaluated the Advanced Lower Body Extremities Restraint Test and a foot loop restraint system by performing representative tasks at the workstation in each of the two restraint systems; at the end of each flight they gave their impressions of each system and the workstation. Results indicated that access to the workstation switch panels was difficult and manipulation of the hand controllers forced operators too low for optimal viewing of the aft flight deck monitors. The workstation panel should be angled for better visibility, and infrequently used switches should be on the aft flight deck panel. Pitch angle and placement of the hand controllers should optimize the operator's eye position with respect to the monitors. The lower body restraint was preferred over the foot loops because it allowed operators to maintain a more relaxed posture during long-duration tasks, its height adjustability allowed better viewing of aft flight deck monitors, and it provided better restraint for reacting forces imparted on the operator at the workstation. The foot loops provide adequate restraint for the flight demonstration tasks identified. Since results will impact the design of the workstation, both restraints should be flown and used during operation of the flight demonstration payload to evaluate the effect of restraint during long-duration tasks.

Sampaio, Carlos E.↗

Defining Exercise Performance Metrics for Flight Hardware Development

The space industry has prevailed over numerous design challenges in the spirit of exploration. Manned space flight entails creating products for use by humans and the Johnson Space Center has pioneered this effort as NASA's center for manned space flight. NASA Astronauts use a suite of flight exercise hardware to maintain strength for extravehicular activities and to minimize losses in muscle mass and bone mineral density. With a cycle ergometer, treadmill, and the Resistive Exercise Device available on the International Space Station (ISS), the Space Medicine community aspires to reproduce physical loading schemes that match exercise performance in Earth s gravity. The resistive exercise device presents the greatest challenge with the duty of accommodating 20 different exercises and many variations on the core set of exercises. This paper presents a methodology for capturing engineering parameters that can quantify proper resistive exercise performance techniques. For each specified exercise, the method provides engineering parameters on hand spacing, foot spacing, and positions of the point of load application at the starting point, midpoint, and end point of the exercise. As humans vary in height and fitness levels, the methodology presents values as ranges. In addition, this method shows engineers the proper load application regions on the human body. The methodology applies to resistive exercise in general and is in use for the current development of a Resistive Exercise Device. Exercise hardware systems must remain available for use and conducive to proper exercise performance as a contributor to mission success. The astronauts depend on exercise hardware to support extended stays aboard the ISS. Future plans towards exploration of Mars and beyond acknowledge the necessity of exercise. Continuous improvement in technology and our understanding of human health maintenance in space will allow us to support the exploration of Mars and the future of space exploration.

Beyene, Nahon M.↗