Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Beamline IDs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Phase-space analysis and experimental results for secondary focusing at X-ray beamlines

Micro-focusing optical devices at synchrotron beamlines usually have a limited acceptance, but more flux can be intercepted if such optics are used to focus secondary sources created by the primary optics. Flux throughput can be maximized by placing the secondary focusing optics close to or exactly at the secondary source position. However, standard methods of beamline optics analysis, such as the lens equation or matching the mirror surface to an ellipse, work poorly when the source-to-optics distance is very short. In this paper the general characteristics of the focusing of beams with Gaussian profiles by a 'thin lens' are analysed under the paraxial approximation in phase space, concluding that the focusing of a beam with a short source-to-optics distance is distinct from imaging the source; slope errors are successfully included in all the formulas so that they can be used to calculate beamline focusing with good accuracy. A method is also introduced to use the thin-lens result to analyse the micro-focusing produced by an elliptically bent trapezoid-shaped Kirkpatrick-Baez mirror. The results of this analysis are in good agreement with ray-tracing simulations and are confirmed by the experimental results of the secondary focusing at the 18-ID Bio-CAT beamline (at the APS). The result of secondary focusing carried out at 18-ID using a single-bounce capillary can also be explained using this phase-space analysis. A discussion of the secondary focusing results is presented at the end of this paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Data management and processing workflow for the Materials Physics and Engineering group beamlines at the Advanced Photon Source

The ability to store, organize, process and distribute experimental data effectively, efficiently and securely is particularly important for large user facilities like the Advanced Photon Source. In this article, the deployment of the APS Data Management System (DM) at the 1-ID and 6-BM beamlines of the APS is described. These two beamlines support a wide range of experimental techniques and generate data at relatively high rates, making them ideal candidates to illustrate the deployment and customization of the DM system and its tools. Using several usage examples at these beamlines, various capabilities of the DM system are described.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FMX – the Frontier Microfocusing Macromolecular Crystallography Beamline at the National Synchrotron Light Source II

Two new macromolecular crystallography (MX) beamlines at the National Synchrotron Light Source II, FMX and AMX, opened for general user operation in February 2017 [Schneider et al. (2013). J. Phys. Conf. Ser. 425 , 012003; Fuchs et al. (2014). J. Phys. Conf. Ser. 493 , 012021; Fuchs et al. (2016). AIP Conf. Proc. SRI2015 , 1741 , 030006]. FMX, the micro-focusing Frontier MX beamline in sector 17-ID-2 at NSLS-II, covers a 5–30 keV photon energy range and delivers a flux of 4.0 × 10 12 photons s −1 at 1 Å into a 1 µm × 1.5 µm to 10 µm × 10 µm (V × H) variable focus, expected to reach 5 × 10 12 photons s −1 at final storage-ring current. This flux density surpasses most MX beamlines by nearly two orders of magnitude. The high brightness and microbeam capability of FMX are focused on solving difficult crystallographic challenges. The beamline's flexible design supports a wide range of structure determination methods – serial crystallography on micrometre-sized crystals, raster optimization of diffraction from inhomogeneous crystals, high-resolution data collection from large-unit-cell crystals, room-temperature data collection for crystals that are difficult to freeze and for studying conformational dynamics, and fully automated data collection for sample-screening and ligand-binding studies. FMX's high dose rate reduces data collection times for applications like serial crystallography to minutes rather than hours. With associated sample lifetimes as short as a few milliseconds, new rapid sample-delivery methods have been implemented, such as an ultra-high-speed high-precision piezo scanner goniometer [Gao et al. (2018). J. Synchrotron Rad. 25 , 1362–1370], new microcrystal-optimized micromesh well sample holders [Guo et al. (2018). IUCrJ , 5 , 238–246] and highly viscous media injectors [Weierstall et al. (2014). Nat. Commun. 5 , 3309]. The new beamline pushes the frontier of synchrotron crystallography and enables users to determine structures from difficult-to-crystallize targets like membrane proteins, using previously intractable crystals of a few micrometres in size, and to obtain quality structures from irregular larger crystals.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dose calculations using MARS for Bremsstrahlung beam stops and collimators in APS beamline stations.

The Monte Carlo radiation transport code MARS is used to model the generation of gas bremsstrahlung (GB) radiation from 7-GeV electrons which scatter from residual gas atoms in undulator straight sections within the Advanced Photon Source (APS) storage ring. Additionally, MARS is employed to model the interactions of the GB radiation with components along the x-ray beamlines and then determine the expected radiation dose-rates that result. In this manner, MARS can be used to assess the adequacy of existing shielding or the specifications for new shielding when required. The GB radiation generated in the 'thin-target' of an ID straight section will consist only of photons in a 1/E-distribution up to the full energy of the stored electron beam. Using this analytical model, the predicted GB power for a typical APS 15.38-m insertion device (ID) straight section is 4.59 x 10{sup -7} W/nTorr/mA, assuming a background gas composed of air (Z{sub eff} = 7.31) at room temperature (293K). The total GB power provides a useful benchmark for comparisons between analytical and numerical approaches. We find good agreement between MARS and analytical estimates for total GB power. The extended straight section 'target' creates a radial profile of GB, which is highly peaked centered on the electron beam. The GB distribution reflects the size of the electron beam that creates the radiation. Optimizing the performance of MARS in terms of CPU time per incident trajectory requires the use of a relatively short, high-density gas target (air); in this report, the target density is {rho}L = 2.89 x 10{sup -2} g/cm{sup 2} over a length of 24 cm. MARS results are compared with the contact dose levels reported in TB-20, which used EGS4 for radiation transport simulations. Maximum dose-rates in 1 cc of tissue phantom form the initial basis for comparison. MARS and EGS4 results are approximately the same for maximum 1-cc dose-rates and attenuation in the photon-dominated regions; for thicker targets, however, the dose-rate no longer depends only on photon attenuation, as photoneutrons (PNs) begin to dominate. The GB radiation-induced photoneutron measurements from four different metals (Fe, Cu, W, and Pb) are compared with MARS predictions. The simulated dose-rates for beamline 6-ID are approximately 3-5 times larger than the measured values, whereas those for beamline 11-ID are much closer. Given the uncertainty in local values of pressure and Z, the degree of agreement between MARS and the PN measurements is good. MARS simulations of GB-induced radiation in and around the FOE show the importance of using actual pressure and gas composition (Z{sub eff}) to obtain accurate PN dose. For a beam current of 300 mA, extrapolating pressure data measured in previously published studies predicts an average background gas pressure of 27 nTorr. An average atomic number of Z{sub eff} = 4.0 is obtained from the same studies. In addition, models of copper masks presently in use at the APS are included. Simulations show that inclusion of exit masks make significant differences in both the radiation spatial distribution within the FOE, as well as the peak intensity. Two studies have been conducted with MARS to assess shielding requirements. First, dose levels in contact with the outside wall of the FOE are examined when GB radiation strikes Pb or W beam stops of varying transverse size within the FOE. Four separate phantom regions are utilized to measure the dose, two at beam elevation and two at the horizontal beam position. The first two phantoms are used for scoring FOE dose along the outside and back walls, horizontally; the second two collect dose on the roof and vertically on the back wall. In all cases, the beam stop depth is maintained at 30 cm. Inclusion of front end (FE) exit masks typically cause a 1-2 order-of-magnitude increase in the dose-rates relative to the case with no masks. Masks place secondary bremsstrahlung sources inside the FOE, and therefore they must be shielded appropriately. The MARS model does not fully account for all shielding present in the hutches; localized shielding is employed in individual hutches. Typically, a collimator, placed downstream of the FE exit masks, mitigates the possible increase in dose. Regarding beam stop transverse size, a modest reduction in dose on the back wall is noted as the stop dimension (square cross section) is increased from 12 cm to 24 cm. In the second study, the thickness of Pb required to shield against the GB extremal ray is determined. In this study, we are interested in finding the thickness of material necessary to add at the edge of a stop to adequately block GB radiation; therefore, we look at the case of no masks in order to have a well-defined GB beam edge. Simulations show the separation between the extremal ray and the edge of the shielding should be 2R{sub m}, where R{sub m} is the Moliere radius.

43 PARTICLE ACCELERATORS↗

Commissioning of the synchrotron radiation protection system and beamlines frontends at NSLS-II

The first eight insertion devices (IDs) at the NSLS-II were commissioned during the fall run of 2014. In this paper we discuss commissioning of the synchrotron radiation protection (SRP) system and beamline frontends (FE) for the respective IDs. We describe the diagnostics utilized if FE commissioning and a procedure that was used for the alignment of the photon beam from insertion devices in the beamline frontends. Then we discuss the current status of the SRP system and operation of the commissioned frontends.

43 PARTICLE ACCELERATORS↗

The large-volume high-pressure facility at GSECARS: A 'Swiss-army-knife' approach to synchrotron-based experimental studies

A number of new techniques have been developed at the large-volume press (LVP) high-pressure facility at the GeoSoilEnviroCARS (GSECARS) sector of the advanced photon source (APS). This article describes the 10 MN (1000 T) and 2.5 MN (250 T) hydraulic presses in the insertion device (ID) and bending magnet (BM) beamlines, respectively, with several apparatus and various diffraction and imaging techniques developed since the inception of the facility. Several Kawai-type high-pressure modules, whose second-stage anvils range from 10 mm to 25.4 mm in edge lengths, are used in the hydraulic presses, with pressure (P) and temperature (T) capabilities up to 30 GPa and 3000 K. A DIA-type apparatus can be compressed in both presses for studies requiring large sample volumes. A deformation DIA (D-DIA) has been developed to allow controlled deformation studies on both crystalline and glass materials, using monochromatic diffraction and imaging, up to 20 GPa and 1800 K. A high-pressure tomography apparatus is available for conducting tomography studies at high P and T, with a typical spatial resolution of a few micrometers. Toroidal anvil modules provide large 2{theta} angles for studies of non-crystalline materials, and a new large D-DIA module is under construction for double-stage megabar pressure generation as well as deformation on large samples with the capability of acoustic emission detection. The flexible design of the monochromator at the BM beamline makes it feasible to switch between monochromatic and white-beam mode during an experiment, ideal for monochromatic imaging studies (e.g., high-P tomography) with energy-dispersive diffraction for pressure measurements. A new angle-dispersive diffraction technique has been developed for high P-T crystallography studies, where a solid-state detector is step-scanned, thereby collecting a large number of angle-dispersive spectra over a wide range of photon energies recorded in the multi-channel analyzer. An ultrasonic interferometer is available and has been used in several high-pressure modules for acoustic velocity measurements. These unique features allow world-wide users to select the best experimental techniques for tackling a wide range of problems relevant to earth and planetary science, materials science, physics, and chemistry. Scientific highlights are provided and future improvements and prospects are discussed.

43 PARTICLE ACCELERATORS↗

Validations of Time-Resolved X-Ray Emissions Spectroscopy for Analysis of Mn-Based Natural and Artifical Sunlight-to-Energy Assemblies

The goal of this project was to demonstrate time resolved analysis of the electronic structure dynamic using techniques of miniature X-ray emission spectrometers. The focus was on development of easy/fast to set up, portable, cost efficient, good energy resolution, good sensitivity, dispersive (particularly suitable for time resolved analysis) system. These mile stones were achieved and miniXES spectrometer for the Mn Kβ range was reported. Contrary to pointby- point detection, the miniXES setup allows a complete emission spectrum to be recorded following each laser excitation, Fig. 1. miniXES system compares favorably with other realization of a dispersive XES spectrometer with cylindrically bent analyzers. Setup reported by others has disadvantages of high cost (which limits its re-creation by other researchers) and lower (0.55 eV) energy resolution (at 6490 eV). The energy resolution of our miniXES system is 0.30 eV. Additional advantage of portability allowed us to use miniXES at multiple beamlines at APS (ANL): 20-ID, 14-ID and 7-ID. Moreover, in March 2013 PI transported the Mn Kβ spectrometer (which fits into a small hand luggage bag) to SLS (Switzerland) and set it up there for the TR-XES beamtime. Our spectrometer works with 2D-PSD (Pilatus-100) which is a standard detector available via equipment pool at synchrotron sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

APS: High-Energy X-rays Expediting Applied and Fundamental Research

The Advanced Photon Source (APS) at Argonne National Laboratory (ANL) was designed and built as one of the first large 3rd generation synchrotrons operated at 7 GeV. The United States Department of Energy (DOE) Office of Science funded the construction and continues to fund the operation of this national facility. Furthermore, the beamlines were originally operated by Collaborative Access Teams (CAT), which allowed a strong involvement of research institutes, universities, and industry. Today 43 of 68 beamlines are operated by the X-ray Science Division (XSD) and 35 beamlines are directly funded by the DOE Office of Science. The APS became operational in 1995, and was planned right from the beginning with 4 beamlines dedicated to high-energy x-rays above 40 keV: 1-ID designed to study engineering materials science, 6-ID-D for magnetism and condensed matter research, 11-ID-B dedicated to magnetic Compton scattering using an Elliptical Multipole Wiggler, and 11-ID-C for materials science and condensed matter physics. These stations were later joined by the bending magnet beamlines 6-BM for white beam studies and 17-BM for rapid powder diffraction. CAT operated beamlines such as 15-ID for crystallography or 16-ID for high-pressure studies also use the high-energy x-ray regime frequently. The program in Compton scattering ended in 2004 and the wiggler was replaced by an undulator. 11-ID-B became the first dedicated station for Pair Distribution Function (PDF) Analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A new Kirkpatrick–Baez-based scanning microscope for the Submicron Resolution X-ray Spectroscopy (SRX) beamline at NSLS-II

The development, construction, and first commissioning results of a new scanning microscope installed at the 5-ID Submicron Resolution X-ray Spectroscopy (SRX) beamline at NSLS-II are reported. The developed system utilizes Kirkpatrick–Baez mirrors for X-ray focusing. The instrument is designed to enable spectromicroscopy measurements in 2D and 3D with sub-200 nm spatial resolution. The present paper focuses on the design aspects, optical considerations, and specifics of the sample scanning stage, summarizing some of the initial commissioning results.

36 MATERIALS SCIENCE↗

28ID1 - PDF Beamline Radiation Shielding Analysis

The high flux hard x-ray damping wiggler (DW100) located in cell 28-ID provides a synchrotron source for the X-ray Powder Diffraction (XPD) beamline and the Pair Distribution Function (PDF) beamline. The primary purpose of these beamlines is the quantitative characterization of the atomic structure of complex materials; not just carefully prepared ideal systems, but materials as they are actually used.

36 MATERIALS SCIENCE↗

The Status of the Taiwan Photon Source

NSRRC has been operating a 1.5 GeV synchrotron light source, the Taiwan Light Source (TLS), for over 15 years and has established a large user community. For the future development of synchrotron radiation research in Taiwan, a feasibility study report to construct a 3.0 GeV low-emittance storage ring, the Taiwan Photon Source (TPS), was issued in July 2005. The government approval of the TPS project was obtained in December 2007 and the machine will be built at current site of NSRRC. The project has progressed steadily since and reached several major milestones now: the architect firm has finished the site plan and civil design, the accelerator design has been fixed, and purchase of long-lead items begins its course. The TPS storage ring has a circumference of 518.4 meters with a concentric booster of 496.8 meters. The storage ring adopted a 24-cell double-bend structure with a 1.6 nm-rad natural emittance. There are six 12-m and eighteen 7-m ID straights. For user research, five new beamlines have been selected for the Phase I operations: the micro protein crystallography, the materials sub-micron diffraction, the inelastic soft x-ray scattering, the coherent x-ray scattering, and the nano probe beamlines. The civil construction is getting ready to start. The commissioning of the TPS storage ring is targeted for 2013.

43 PARTICLE ACCELERATORS↗

Laser, vacuum and gas reaction chamber for operando measurements at NSLS-II's 28-ID-2

We present a laser reaction chamber that we have developed for in situ/operando X-ray diffraction measurements at the NSLS-II 28-ID-2 X-ray powder diffraction beamline. This chamber allows for rapid and dynamic sample heating under specialized gas environments, spanning ambient conditions down to vacuum pressures. We demonstrate the capabilities of this setup through two applications: laser-driven heating in polycrystalline iron oxide and in single-crystal WTe 2 . Our measurements reveal the ability to resolve chemical reaction kinetics over minutes with 1 s time resolution. This setup advances opportunities for in situ/operando X-ray diffraction studies of both bulk and single-crystal materials.

36 MATERIALS SCIENCE↗

XRF-ROI Finder: Machine Learning to Guide Region-of-Interest Scanning for X-ray Fluorescence Microscopy

The ROI-finder software is being developed for use by several Microscopy Group beamlines at Argonne National Laboratory, including 2-ID microprobes and 9-ID-B Bionanoprobe which use multi-scale scanning fluorescence microscopy to acquire elemental maps (multi-modal image data). Microscopy experiments require scan of samples at a coarse resolution followed by ROI identification using feature detection based on domain expertise. Finer resolution scans are then conducted based on identified ROI. The decision-making process based on domain expertise will be difficult to perform for faster data rates and much larger sampling volumes anticipated after APS-U necessitating the need for the ROI-finder software. The ROI- finder detects regions of interest through a continuous learning process, starting with a unsupervised representation learning and improving its recommendations through supervised learning and an interactive tool for user annotation. The scope of ongoing development efforts includes the integration of image registration module to correlate optical and X-ray images, extraction of feature morphology as well as elemental signatures in the image space and incorporation of beamtime streaming data by the scanning probe via EPICS.

CHOWDHURY, M. ARSHAD ZAHANGIR↗

FOFB-compatible AC Local Bump as a Potential New Operations Mode for NSLS-II

AC local bumps of the beam orbit developed at NSLS-II are successfully used for accelerator physics studies. Recently, AC bumps localized at light-generating insertion devices (ID) are considered by NSLS-II beamline scientists as a possible user operation mode. The AC perturbation of the X-ray beam in a controllable way will provide a possibility to investigate the effects of the source size and temporal evolution on the coherence of the photon beam. It also can be used to average out the spatial non-uniformity of the beam intensity caused by the beamline optics. Before the implementation of the AC orbit bumps into user operations, we must investigate if the electron beam perturbation affects the other beamlines. A proof-of-principle experiment was carried out: an AC bump was created and well localized in the CSX and/or FXI beamline. Transparency of this AC bump to other beamlines has been studied, the results are discussed.

36 MATERIALS SCIENCE↗

Mini-beam collimator enables micro-crystallography experiments on standard beamlines.

The high-brilliance X-ray beams from undulator sources at third-generation synchrotron facilities are excellent tools for solving crystal structures of important and challenging biological macromolecules and complexes. However, many of the most important structural targets yield crystals that are too small or too inhomogeneous for a 'standard' beam from an undulator source, 25-50 {micro}m (FWHM) in the vertical and 50-100 {micro}m in the horizontal direction. Although many synchrotron facilities have microfocus beamlines for other applications, this capability for macromolecular crystallography was pioneered at ID-13 of the ESRF. The National Institute of General Medical Sciences and National Cancer Institute Collaborative Access Team (GM/CA-CAT) dual canted undulator beamlines at the APS deliver high-intensity focused beams with a minimum focal size of 20 {micro}m x 65 {micro}m at the sample position. To meet growing user demand for beams to study samples of 10 {micro}m or less, a 'mini-beam' apparatus was developed that conditions the focused beam to either 5 {micro}m or 10 {micro}m (FWHM) diameter with high intensity. The mini-beam has a symmetric Gaussian shape in both the horizontal and vertical directions, and reduces the vertical divergence of the focused beam by 25%. Significant reduction in background was achieved by implementation of both forward- and back-scatter guards. A unique triple-collimator apparatus, which has been in routine use on both undulator beamlines since February 2008, allows users to rapidly interchange the focused beam and conditioned mini-beams of two sizes with a single mouse click. The device and the beam are stable over many hours of routine operation. The rapid-exchange capability has greatly facilitated sample screening and resulted in several structures that could not have been obtained with the larger focused beam.

36 MATERIALS SCIENCE↗

Compressional behavior of omphacite to 47 GPa

Omphacite is an important mineral component of eclogite. Single crystal synchrotron X-ray diffraction data on natural (Ca,Na)(Mg,Fe,Al)Si 2 O 6 omphacite have been collected at the Advanced Photon Source beamlines 13-BM-C and 13-ID-D up to 47 GPa at ambient temperature. Unit cell parameter and crystal structure refinements were carried out to constrain the isothermal equation of state and compression mechanism. The 3rd order Birch-Murnaghan equation of state (BM3) fit of all data gives V o = 423.9(3) Å3, K To = 116(2) GPa and K To ’ = 4.3(2). These elastic parameters are consistent with the general trend of the diopside-jadeite join. The eight-coordinated polyhedra (M2 and M21) are the most compressible, and contribute to majority of the unit cell compression, while the SiO 4 tetrahedra (Si1 and Si2) behave as rigid structural units and are the most incompressible. Axial compressibilities are determined by fitting linearized BM 3 equation of state to pressure dependences of unit cell parameters. Throughout the investigated pressure range, the b-axis is more compressible than the c-axis. Here, the axial compressibility of the α-axis is the largest among the three axes at 0 GPa, yet it quickly drops to the smallest at pressures above 5 GPa, which is explained by the rotation of the stiffest compression axis toward the a-axis with the increase of pressure.

36 MATERIALS SCIENCE↗

Reviewed approach to defining the Active Interlock Envelope for Front End ray tracing

To protect the NSLS-II Storage Ring (SR) components from damage from synchrotron radiation produced by insertion devices (IDs) the Active Interlock (AI) keeps electron beam within some safe envelope (a.k.a Active Interlock Envelope or AIE) in the transverse phase space. The beamline Front Ends (FEs) are designed under assumption that above certain beam current (typically 2 mA) the ID synchrotron radiation (IDSR) fan is produced by the interlocked e-beam. These assumptions also define how the ray tracing for FE is done. To simplify the FE ray tracing for typical uncanted ID it was decided to provide the Mechanical Engineering group with a single set of numbers (x,x’,y,y’) for the AIE at the center of the long (or short) ID straight section. Such unified approach to the design of the beamline Front Ends will accelerate the design process and save valuable human resources. In this paper we describe our new approach to defining the AI envelope and provide the resulting numbers required for design of the typical Front End.

43 PARTICLE ACCELERATORS↗

Reviewed Approach to Defining the Active Interlock Envelope for Front End Ray Tracing

To protect the NSLS-II Storage Ring (SR) components from damage from synchrotron radiation produced by insertion devices (IDs) the Active Interlock (AI) keeps electron beam within some safe envelope (a.k.a Active Interlock Envelope or AIE) in the transverse phase space. The beamline Front Ends (FEs) are designed under assumption that above certain beam current (typically 2 mA) the ID synchrotron radiation (IDSR) fan is produced by the interlocked e-beam. These assumptions also define how the ray tracing for FE is done. To simplify the FE ray tracing for typical uncanted ID it was decided to provide the Mechanical Engineering group with a single set of numbers (x,x’,y,y’) for the AIE at the center of the long (or short) ID straight section. Such unified approach to the design of the beamline Front Ends will accelerate the design process and save valuable human resources. In this paper we describe our new approach to defining the AI envelope and provide the resulting numbers required for design of the typical Front End.

36 MATERIALS SCIENCE↗