Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BPS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Electrocatalytically Upgrading Methane to Benzene in a Highly Compacted Microchannel Protonic Ceramic Membrane Reactor

This project aims to develop highly compacted microchannel protonic ceramic membrane reactors (HCM-PCMRs) for efficient and cost-effective methane dehydrogenation to aromatics (MDA, e.g., benzene). The integration of single-atom catalysis, electrocatalysis, membrane catalysis, membrane separation, and advanced manufacturing is designed to fulfill this goal. This project's success will ultimately develop a new cost-effective, efficient, and highly compacted infrastructure technology to address the flare and venting issue during oil and gas operations and other gas-to-liquid technologies. The key objectives for the three budget periods (BPs) are as follows.

02 PETROLEUM↗

Advanced Mixed Mode Combustor for Hydrogen F-Class Retrofit (Final Report)

This objective of this project was to develop a retrofittable combustor module for the GE Vernova Operations LLC (GE Vernova, GEV) frame 7F gas turbine (GT) that would allow operation on blends of hydrogen in Natural Gas (NG) between 0% and 100%. The new system was to be part of a package that retained current cycle performance while limiting the increase in NOx emissions to the equivalent of 25ppm (parts per million by volume dry at 15% O2, ppmvd15) with consideration for the impact of hydrogen fuel on the O2 correction. The expectation was that with the addition of Axial Fuel Staging (AFS), turndown within emission compliance would be extended to below 20% GT load. The original project plan included three budget periods (BPs): BP1 spanning October 1, 2022 through August 31, 2024; BP2 spanning September 1, 2024 through December 31, 2025; and BP3 spanning January 1, 2026 through September 30, 2026. The project was terminated early by the DOE on October 10, 2025 about three months prior to the end of BP2. BP3 activities were therefore cancelled. The program was on track to meet all objectives prior to the DOE termination. This Final Report covers work completed during BP1 and BP2 prior to the program termination.

08 HYDROGEN↗

Digital Grid Twin–Direct Communication Scheme Test Bed for Assessing Relay-to-Relay Radio Antenna and Optical Fiber Performance and Misoperations

This study introduces a novel “Digital Grid Twin–Direct Communication Scheme” test bed. This advanced platform evaluates point-to-point communication between transmitter and receiver relays with optical fiber and radio omnidirectional antenna systems, implemented at the Advanced Protection lab in the Grid Research Innovation and Development Center at Oak Ridge National Laboratory. The increased diversity of energy sources has led to more protective relay misoperations. In North America, microgrid protection schemes now use point-to-point communication along distribution lines between relays to implement advanced logic in nonradial grids that include both high- and low-inertia generators. This trend challenges utilities to minimize misoperations while ensuring rapid fault clearance and accurate selectivity coordination between primary and backup relays. This study assesses relay-to-relay communication schemes by introducing an advanced testing platform based on a digital grid twin protection test bed using a synchronized time source system. The platform evaluates the communication system using radio antennas or optical fiber links by integrating protective relays that operate breakers within the digital twin and record relay events and communication signals. In the experiments, transmitter and receiver relays were configured with inverse time overcurrent and breaker trip detection logic to assess the total time of the communication protection schemes based on the sum of the relay protection element operating time, radio latency, propagation delay, baud rate delay, and relay processing time. These delays were derived from recorded relay events and communication signals from the interface of a real-time simulator set as a digital grid twin. The test bed successfully simulated various electrical faults along a distribution line while ensuring effective and reliable point-to-point communication between transmitter and receiver relays. The radio antenna communication system exhibited latency because of the radio. This latency depends on the baud rate setting and type of radio application; in general, the higher the baud rate, the lower the radio latency. The measured radio latency (for Mirrored Bits with an encryption card at 9,600 bps) was about 9–10 ms. Additionally, calculated propagation delay per mile for radio antennas and optical fiber was 5.36 µs/mi and 8.04 µs/mi, respectively. Optical fiber communication did not demonstrate radio latency. Instead, the protection element operating time depends mainly on the protection logic function set in the relay, and the relay processing time depends on the processing rate of the relay in samples per power system cycle.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Miniature Coil for Wireless Power and Data Transfer through Aluminum

This paper presents the design and development of miniature coils for wireless power and data transfer through metal. Our coil has a total size of 15 mm × 13 mm × 6 mm. Experimental results demonstrate that we can harvest 440 mW through a 1 mm-thick aluminum plate. Aluminum and stainless-steel barriers of different thicknesses were used to characterize coil performance. Using a pair of the designed coils, we have developed a through-metal communication system to successfully transfer data through a 1 mm-thick aluminum plate. A maximum data rate of 100 bps was achieved using only harvested power. To the best of our knowledge, this is the first report that demonstrates power and data transfer through aluminum using miniature coils.

42 ENGINEERING↗

Global Magni4icence, or: 4G Networks

The global magnificent four theory is the homological version of a maximally supersymmetric $(8+1)$-dimensional gauge theory on a Calabi-Yau fourfold fibered over a circle. In the case of a toric fourfold we conjecture the formula for its twisted Witten index. String-theoretically we count the BPS states of a system of $D0$-$D2$-$D4$-$D6$-$D8$-branes on the Calabi-Yau fourfold in the presence of a large Neveu-Schwarz $B$-field. Mathematically, we develop the equivariant $K$-theoretic DT4 theory, by constructing the four-valent vertex with generic plane partition asymptotics. Physically, the vertex is a supersymmetric localization of a non-commutative gauge theory in $8+1$ dimensions.

Mathematics↗

Living on the edge: a non-perturbative resolution to the negativity of bulk entropies

Lin, Maldacena, Rozenberg, and Shan (LMRS) presented a new information paradox in black hole physics by noticing that the entanglement and Rényi entropies in a two-sided black hole can become negative when the geometry contains a very large number of matter excitations behind the black hole horizon. While originally this puzzle was presented in the context of BPS two-sided black holes in two-dimensional supergravity, the negativity in fact persists for more general two-sided black holes in the presence of a large number of matter excitations. Since the entanglement and Rényi entropies in ordinary quantum systems cannot be negative, resolving this puzzle is a necessary step towards understanding the quantum mechanical description of black holes. In this paper, we explain how to address the entanglement negativity puzzle, both in the original setting discussed by LMRS and in more general non-supersymmetric settings, by summing over all non-perturbative contributions to the gravitational path integral. We then interpret this result from the point of view of a dual matrix integral, which we use to extend our analysis beyond the regime of validity of the genus re-summation performed in the gravitational path integral. In this regime, positivity is rescued by new saddles of the matrix integral, a one-eigenvalue instanton and a two-eigenvalue instanton. Finally, we formulate a similar puzzle and its resolution using random tensor network techniques.

FOS: Physical sciences↗

SEED Platform for Building Performance Standards Implementation Guide (Spanish Translation)

This guide provides an overview of the Standard Energy Efficiency Data (SEED) Platform. The SEED Platform developed by the U.S. Department of Energy (DOE) to provide a low-cost, user-friendly tool for jurisdictions to launch and manage energy benchmarking and Building Performance Standard (BPS) programs. It has been translated into Spanish. This is the Spanish translation of NREL/FS-5500-90691.

benchmarking↗

SEED Platform for Building Performance Standards Implementation Guide (French Translation)

This guide provides an overview of the Standard Energy Efficiency Data (SEED) Platform. The SEED Platform developed by the U.S. Department of Energy (DOE) to provide a low-cost, user-friendly tool for jurisdictions to launch and manage energy benchmarking and Building Performance Standard (BPS) programs. It has been translated into Spanish. This is the French translation of NREL/FS-5500-90691.

benchmarking↗

SEED Platform for Building Performance Standards Implementation Guide (Arabic Translation)

This guide provides an overview of the Standard Energy Efficiency Data (SEED) Platform. The SEED Platform developed by the U.S. Department of Energy (DOE) to provide a low-cost, user-friendly tool for jurisdictions to launch and manage energy benchmarking and Building Performance Standard (BPS) programs. It has been translated into Spanish. This is the Arabic translation of NREL/FS-5500-90691.

benchmarking↗

SEED Platform for Building Performance Standards Implementation Guide (Mandarin Translation)

This guide provides an overview of the Standard Energy Efficiency Data (SEED) Platform. The SEED Platform developed by the U.S. Department of Energy (DOE) to provide a low-cost, user-friendly tool for jurisdictions to launch and manage energy benchmarking and Building Performance Standard (BPS) programs. It has been translated into Spanish. This is the Mandarin translation of NREL/FS-5500-90691.

benchmarking↗

The New Face of Standard 100

In January 2024, ASHRAE published a significant overhaul to ANSI/ASHRAE/IES Standard 100-2018, Energy Efficiency in Existing Buildings. You may almost not recognize it. Standard 100-2024, Energy and Emissions Building Performance Standard for Existing Buildings, now addresses both energy and emissions performance as a model building performance standard (BPS). ASHRAE Standing Standard Project Committee (SSPC) 100, with direction from ASHRAE and its Task Force for Building Decarbonization (TFBD) has been working to update the standard to make it a model for building performance standard adoption across the U.S. and internationally. Here, the new edition of Standard 100 addresses key issues of climate change surrounding building performance, including new metrics for greenhouse gas (GHG) emissions targets, continuing to support the imperative of improving our existing building stock and meeting global climate change commitments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grid and Wind Transient Ride Through Assessment of Type-5 Synchronous Wind Turbine

The integration of the inverter-based renewable energy resources is increasing and replacing conventional synchronous generators in the evolving bulk power system (BPS), impacting the system inertia along the way. Also, the limited over-current capability of power electronic converters continues to deteriorate the grid strength of the evolving power systems. Type-5 wind turbines have the potential to mitigate these problems because this configuration interfaces with the grid through a synchronous generator; hence, its operation and consequent grid impacts might mimic the conventional synchronous generator. The drivetrain of this type of turbines, however, is different from the more common Type-3 and Type-4 turbines. A hydraulic torque converter and gearbox with torque limiting feature are integral parts of a Type-5 wind turbine drivetrain, to isolate the wind speed variations at the wind turbine rotor from the grid connected generator side. This supports the synchronous operation of the generator. However, high fidelity models of Type-5 wind turbine drivetrain including these core components are not openly and widely available for grid integration and transient stability studies. Moreover, Type-5 turbines are not commonly deployed and hence its power generation and frequency stability characteristics are not widely publicized. This hinders appropriate assessment of Type-5 wind power plant's contribution to bulk grid resilience. This work provides transient stability assessment of a standalone Type-5 wind turbine. Normal operation and grid transient studies are performed to see the step load change and wind speed disturbance impacts on the Type-5 drivetrain and generation dispatch. Preliminary results show that Type-5 wind turbines can support load changes of between 0.6 p.u to 1.15 p.u. Beyond this point, the synchronization of the generator starts to deviate from its set point.

17 - WIND ENERGY↗

Urban building energy modeling (UBEM) tools: A state-of-the-art review of bottom-up physics-based approaches

Regulations corroborate the importance of retrofitting existing building stocks or constructing new energy-efficient districts. There is, thus, a need for modeling tools to evaluate energy scenarios to better manage and design cities, and numerous methodologies and tools have been developed. Among them, Urban Building Energy Modelling (UBEM) tools allow the energy simulation of buildings at large scales. Choosing an appropriate UBEM tool, balancing the level of complexity, accuracy, usability, and computing needs, remains a challenge for users. The review focuses on the main bottom-up physics-based UBEM tools, comparing them from a user-oriented perspective. Five categories are used: (i) the required inputs, (ii) the reported outputs, (iii) the exploited workflow, (iv) the applicability of each tool, and (v) the potential users. Moreover, a critical discussion is proposed, focusing on interests and trends in research and development. The results highlighted major differences between UBEM tools that must be considered to choose the proper one for an application. Finally, barriers of adoption of UBEM tools include the needs of a standardized ontology, a common three-dimensional city model, a standard procedure to collect data, and a standard set of test cases. This feeds into future development of UBEM tools to support cities’ sustainability goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Commercial Building Energy Use in Des Moines, Cedar Rapids, and Sioux Falls: Building Stock Segmentation for Retrofit Planning

This report is part of the second phase of a publication series focusing on approximately 100 different local geographies, or "clusters." Each report provides characteristic features and energy data for commercial buildings in a specific area to help policy makers at the city, county, and state level better understand building energy use and emissions. This report breaks down the energy consumption and emissions of the building stock in the counties shown in Figure 2 by building type, building size, end use, energy consumption, emissions, and segment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Commercial Building Energy Use in the Greater Little Rock Area: Building Stock Segmentation for Retrofit Planning

This report is part of the second phase of a publication series focusing on approximately 100 different local geographies, or "clusters." Each report provides characteristic features and energy data for commercial buildings in a specific area to help policy makers at the city, county, and state level better understand building energy use and emissions. This report breaks down the energy consumption and emissions of the building stock in the counties shown in Figure 2 by building type, building size, end use, energy consumption, emissions, and segment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Commercial Building Energy Use in Northwestern PA, Ashtabulam, and Chautauqua Counties: Building Stock Segmentation for Retrofit Planning

This report is part of the second phase of a publication series focusing on approximately 100 different local geographies, or "clusters." Each report provides characteristic features and energy data for commercial buildings in a specific area to help policy makers at the city, county, and state level better understand building energy use and emissions. This report breaks down the energy consumption and emissions of the building stock in the counties shown in Figure 2 by building type, building size, end use, energy consumption, emissions, and segment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Commercial Building Energy Use in the Evansville and Shawnee National Forest Area: Building Stock Segmentation for Retrofit Planning

This report is part of the second phase of a publication series focusing on approximately 100 different local geographies, or "clusters." Each report provides characteristic features and energy data for commercial buildings in a specific area to help policy makers at the city, county, and state level better understand building energy use and emissions. This report breaks down the energy consumption and emissions of the building stock in the counties shown in Figure 2 by building type, building size, end use, energy consumption, emissions, and segment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Commercial Building Energy Use in the Rural Eastern Climate Zone 5A Area: Building Stock Segmentation for Retrofit Planning

This report is part of the second phase of a publication series focusing on approximately 100 different local geographies, or "clusters." Each report provides characteristic features and energy data for commercial buildings in a specific area to help policy makers at the city, county, and state level better understand building energy use and emissions. This report breaks down the energy consumption and emissions of the building stock in the counties shown in Figure 2 by building type, building size, end use, energy consumption, emissions, and segment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗