Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BOILERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Mercury Stable Isotope Fractionation During Coal Combustion in Coal-Fired Boilers: Reconciling Atmospheric Hg Isotope Observations with Hg Isotope Fractionation Theory

Mercury (Hg) stable isotope is a useful tool to understand the transformation of atmospheric Hg. The observation on the enrichment of heavier isotopes in gaseous elemental Hg (GEM) relative to oxidized Hg{sup II} species in atmosphere cannot be convincingly explained by isotope fractionation of Hg redox processes. This review shows that the large Hg isotope mass dependent fractionation (MDF) in coal-fired boilers is one of the underlying reasons. The reported Hg isotope data of feed coals and their combustion products are first summarized to give a general overview of how Hg isotopes fractionate before Hg discharge from coal-fired boilers. Then, predictive MDF models are discussed to simulate δ{sup 202}Hg values of different Hg species in coal combustion flue gases. The discharged GEM is predicted to have the highest δ{sup 202}Hg followed by gaseous Hg{sup II} and particulate-bound Hg{sup II}, which is in consistent with the observed MDF pattern of atmospheric Hg species.

54 ENVIRONMENTAL SCIENCES↗

Elevated Temperature Corrosion Studies of AlCrN and TiAlN Coatings by PAPVD on T91 Boiler Steel

The present investigation discusses the hot corrosion behavior of AlCrN and TiAlN nano-coatings on T91 boiler steel by PAPVD process subjected to molten salt of Na{sub 2}SO{sub 4}-60%V{sub 2}O{sub 5} at 900 °C for 50 cycles. Surface and cross-sectional studies were performed by AFM, SEM/EDS and XRD techniques to understand the corrosion kinetics and mechanism. T91 bare boiler steel as well as TiAlN-coated specimen has shown higher internal oxidation as well as weight gain. The better corrosion resistance of AlCrN-coated specimen has been observed by virtue of higher availability of Cr and Al in the oxide scale as well as adherent and dense coating. The betterment of AlCrN coating can be attributed to low internal oxidation as well as movement of Cr and Al toward oxide scale to form protective corrosion barriers.

36 MATERIALS SCIENCE↗

Polymer heat exchanger design for condensing boiler applications

Condensing boilers achieve very high efficiency levels by recovering both sensible heat and water vapor latent heat from the flue gas. Research since the 1980's has focused on corrosion in such condensing heat exchangers related to the acidic condensate and material selection. Polymers in condensing heat exchangers have been considered to avoid the cost and corrosion concerns of metallic designs. Past efforts have shown that polymers offer the advantage of corrosion resistance and cost, however, lower thermal conductivity limited their application. More recent developments have introduced thermally conductive polymers which now offer promising conductivity values. This project focused on the evaluation of a thermally conductive polymer heat exchanger for this application. Computational fluid dynamic results indicated thermal conductivity values of stainless steel, a typical heat exchanger material, do not need to be achieved for similar heat transfer performance. An increase in thermal conductivity from about 10 times that of the base polymer can achieve an overall heat exchanger effectiveness similar to that achieved with stainless steel. A polymer composite thermal conductivity of approximately 2.5 W/m∙K would be adequate. Thermally conductive polymer materials are now commercially available which offer values up to 20 W/m∙K. In this work, one Nylon-12 and one thermally conductive polymer composite heat exchanger prototypes were constructed for a condensing boiler application. In conclusion, tests demonstrated that good overall heat transfer performance was achieved. The lower thermal conductivity of the polymer heat exchanger will lead to higher surface temperatures and lower water condensation rates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Staged, Pressurized Oxy-Combustion Technology: Status and Application to Boiler Retrofits to Yield Carbon-Negative Power via Biomass

Recognizing the benefits of pressurization and fuel staging on the efficiency of oxy-combustion, the staged, pressurized oxy-combustion (SPOC) process was introduced in 2012. The combination of fuel staging and pressurized oxy-combustion results in a more compact plant, a higher plant efficiency and reduced costs for pollutant and greenhouse gas removal compared with plants equipped with conventional carbon capture. This approach to power generation enables a modular boiler design and optimizes the plant for flexible operation, which is essential to meet the demands of the modern grid when it contains intermittent power sources. Originally designed to burn coal, the SPOC process is well-suited for biomass because the combustion of biomass leads to a high moisture content in the flue gas and the SPOC process is able to recover the latent heat of this moisture, enhancing system performance over that of traditional biomass combustion at atmospheric pressure. The present work is focused on evaluating the potential for utilizing the SPOC process in retrofit applications wherein the boilers of an existing plant are replaced with the SPOC process, and woody biomass is used as the fuel to yield carbon-negative power. Two applications are considered: power generation and cogeneration (heat and power). Modeling these systems in Aspen Plus demonstrates that the SPOC process surpasses the performance of baseline plants with post-combustion capture (PCC) for both power generation and cogeneration. Specifically, compared to a PCC equipped plant, the SPOC power plant has 33% higher efficiency, and the SPOC cogeneration plant reaches 42% higher net energy. Experimentally, the existing SPOC facility was fired for the first time with 100% biomass and after minor improvements were made to the feeding system, the facility demonstrated excellent performance during startup, steady-state operation and turndown.

Carbon capture and storage↗

Study of the scale formed on super 304H boiler tube steels after long-term steam oxidation at high temperatures

Highlights: • Steam oxidation tests were performed on the conventional and shot-peened Super304H boiler tube. • A continuous amorphous SiO{sub 2} layer separated the metal from the scale in shot-peened specimen. • The SiO{sub 2} layer enhanced the formation of dense Cr{sub 2}O{sub 3} and FeCr{sub 2}O{sub 4} layers. • The scale on shot-peened specimens is stable upon steam temperature and time increase. Steam oxidation of a Super 304H boiler tube was performed at steam temperatures of 650 °C and 700 °C for time durations up to 5000 h. The oxidation scale outcomes which formed on as-received untreated and shot-peened (SP) tubes were studied using X-ray diffraction (XRD), scanning electron microscopy (SEM), electron backscatter diffraction (EBSD), and transmission electron microscopy (TEM). γ-Grain nanocrystallization on the surface of the SP specimen generated an abundant fraction of grain boundary that guaranteed the formation of a continuous amorphous SiO{sub 2} layer at the metal-scale interface that enhanced the formation of dense Cr{sub 2}O{sub 3} and FeCr{sub 2}O{sub 4} in the scale. Scale breakaway along defects in the outer layer of the scale was accelerated by the steam temperature in the untreated specimens, whereas the scale that formed on the SP specimens appeared to be stable.

36 MATERIALS SCIENCE↗

Effect of Thermal Storage on the Emissions and Efficiency Performance of a Wood Pellet-Fired Residential Boiler

Wood pellet boilers for residential heating applications offer the promise of low emissions, high efficiency, and automatic operation. However, when operated in the field, these units operate often at very low loads causing them to cycle. In this study, the performance of a 25-kW modern pellet boiler under emulated field conditions and fixed nominal loads of 15% and 100% has been studied in a lab—with and without a buffer tank. A dilution tunnel approach was used for the measurement of particulate emissions, in accordance with U.S. certification testing requirements under EPA Methods 28 WHH and 28 WHH PTS. Results show that increasing the amount of thermal storage used decreases cycling rates leading to decreased emissions and increased efficiency. Without thermal storage, integrated efficiency over a 15% load test period was 57%, compared to 74% when thermal storage was used. Particulate emissions were 180 mg/MJ and 64 mg/MJ for the 15% load case without and with thermal storage, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Capacity mapping for optimum utilization of pulverizers for coal fired boilers - article no. 032201

Capacity mapping is a process of comparison of standard inputs with actual fired inputs to assess the available standard output capacity of a pulverizer. The base capacity is a function of grindability; fineness requirement may vary depending on the volatile matter (VM) content of the coal and the input coal size. The quantity and the inlet will change depending on the quality of raw coal and output requirement. It should be sufficient to dry pulverized coal (PC). Drying capacity is also limited by utmost PA fan power to supply air. The PA temperature is limited by air preheater (APH) inlet flue gas temperature; an increase in this will result in efficiency loss of the boiler. The higher PA inlet temperature can be attained through the economizer gas bypass, the steam coiled APH, and the partial flue gas recirculation. The PS/coal ratioincreases with a decrease in grindability or pulverizer output and decreases with a decrease in VM. The flammability of mixture has to be monitored on explosion limit. Through calibration, the PA flow and efficiency of conveyance can be verified. The velocities of coal/air mixture to prevent fallout or to avoid erosion in the coal carrier pipe are dependent on the PC particle size distribution. Metal loss of grinding elements inversely depends on the YGP index of coal. Variations of dynamic loading and wearing of grinding elements affect the available milling capacity and percentage rejects. Therefore, capacity mapping in necessary to ensure the available pulverizer capacity to avoid overcapacity or undercapacity running of the pulverizing system, optimizing auxiliary power consumption. This will provide a guideline on the distribution of raw coal feeding in different pulverizers of a boiler to maximize system efficiency and control, resulting in a more cost effective heat rate.

01 COAL, LIGNITE, AND PEAT↗

Characterization of Oxy-combustion Impacts in Existing Coal-fired Boilers

This report summarizes Year 2 results of a research program designed to use multi-scale experimental studies and fundamental theoretical models to characterize and predict the impacts of retrofit of existing coal-fired utility boilers for oxy-combustion. Year 2 focused extensively on obtaining experimental data from the bench-scale, lab-scale and pilot-scale reactors. These data will be used to refine and validate submodels to be implemented in CFD simulations of full-scale boiler retrofits. Program tasks are on schedule for Year 3 completion. Both Year 2 milestones were completed on schedule and within budget.

01 COAL, LIGNITE, AND PEAT↗

Development of Self-Powered Wireless-Ready High Temperature Electrochemical Sensors for In-Situ Corrosion Monitoring for Boiler Tubes in Next Generation Coal-based Power Systems

The key innovation of this project is the synergy of the high temperature sensor technology based on the science of electrochemical measurement and state-of-the-art wireless communication technology. A novel self-powered wireless high temperature electrochemical sensor system has been developed for coal-fired boilers used for power generation. An initial prototype of the in-situ sensor demonstrated the capability of the wireless communication system in the laboratory and in a pilot plant (Industrial USC Boiler Setting) environment to acquire electrochemical potential and current signals during the corrosion process. Uniform and localized under-coal ash deposit corrosion behavior of Inconel 740 superalloy has been studied at different simulated coal ash hot corrosion environments using the developed sensor. Two typical potential noise patterns were found to correlate with the oxidation and sulfidation stages in the hot coal ash corrosion process. Two characteristic current noise patterns indicate the extent of the corrosion. There was a good correlation between the responses of electrochemical test data and the results from corroded surface analysis. Wireless electrochemical potential and current noise signals from a simulated coal ash hot corrosion process were concurrently transmitted and recorded. The results from the performance evaluation of the sensor confirm a high accuracy in the thermodynamic and kinetic response represented by the electrochemical noise and impedance test data.

47 OTHER INSTRUMENTATION↗

Technical Assessment of Using Biomass from Methyl-bromide Treated Fields in Solid Fuel Boilers

Approximately 2,500 tons of alfalfa hay in Idaho farm fields were impacted by excessive amount of bromide (Br) from field application of methyl bromide, which makes them unsuitable for animal feed. The Idaho State Department of Agriculture (ISDA) engaged the Biomass Feedstock National User Facility (BFNUF) at the Idaho National Laboratory (INL) with an objective to evaluate the feasibility of affected alfalfa as a boiler fuel to provide thermal heat. To this end, the following tasks were conducted and accomplished: (1) alfalfa characterization, both as received and processed; (2) environment, safety and health (ES&H) monitoring associated with alfalfa processing; (3) alfalfa processing and densification; (4) combustion analysis in a lab-scale boiler.

09 BIOMASS FUELS↗

Performance of a Biomass Boiler in a Load Profile Test

In this report, results are presented of the performance evaluation of a modern residential cordwood-fired hydronic heater. This unit was tested under a specific load and operating profile that includes cold start, four load levels, reload, and cycling in response to an emulated thermostat. The protocol can be completed in a single day, which allows for replicate runs in about a week of testing. This can characterize variability with greater confidence than current methods used in certification testing, reduces time to conduct certification tests, and moves toward greater representative operations as the test includes start-up and requires boilers to respond to a variety of heat loads in a manner that better reflects day-to-day operations. Detailed in the report are the results of triplicate testing of one U.S. Environmental Protection Agency-certified cordwood-fired outdoor wood boiler. Cold start emissions were the greatest among all testing periods. In triplicate testing, emission output values for the cold start tests were 9.52, 4.74, and 6.63 lb/MMBtu of output for Test 1, 2, and 3, respectively. The overall emission output values for Test 1, 2, and 3 were 0.44, 0.34, and 0.19 lb/MMBtu of output, respectively. Additionally, the work in this project found significant differences in filter sampling methods with different integrated time periods. The use of real-time particulate matter emission measurement devices was explored. Specifically, sampling with one filter over a long test with various phases (cold starts, reloads, high and low burns) yielded lower particulate mass than sampling phase by phase (one filter for high burns, one filter for low burns, etc.). Perhaps the use of a real-time particulate matter emission measurement device can be used to distinguish different burn phases without having to change filters multiple times throughout a varied load test method

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Watertube or Firetube Industrial Boiler, 150,000 lbs/hr Capacity

This unit process quantifies the total mass of steel required for the construction of a single 150,000 lbs/hr capacity watertube or firetube boiler. The boiler is assumed to be comprised entirely of steel plate. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=15451C24-413F-4840-9B16-E6E53F8AC751

42 ENGINEERING↗

Equivalent Safety Evaluation of the 2021 Edition of the ASME Boiler and Pressure Vessel Code to Editions Incorporated by Reference in 49 CFR 192, 193, and 195

Federal safety standards for natural gas and hazardous liquid pipelines and liquid natural gas facilities incorporate rules and requirements for boiler and pressure vessel design and fabrication into 49 CFR Parts 192, 193, and 195 through the IBR process. The equivalent safety evaluations documented in this report demonstrate that boilers and pressure vessels in pipeline facilities that are designed and fabricated in accordance with rules and requirements specified in the 2021 edition do not violate the fundamental safety assumptions stated or implied in the 2007 edition of the ASME BPVC and therefore provide equivalent safety.

03 NATURAL GAS↗

An Integrated Approach to Predicting Ash Deposition and Heat Transfer in Coal-Fired Boilers

The overall goal of this project is to develop via measurements and simulations an advanced online technology to predict, monitor and manage fireside ash deposition in a coal-fired boiler allowing for more efficient operations under a range of load conditions and fuel property variability. With this in place fuel sorting and blending can be done upstream and operations can be optimized to compensate for load and fuel properties. In support of this objective, three experimental campaigns were undertaken during the course of the project to measure ash deposition rates within the boiler at different fuel flow rates and its ash composition variability. Simulations of the experimental conditions representing actual geometry, operational scenarios in terms of air flow rates, coal flow rates as well as coal compositions, heating values, and particle size distributions were also carried out. Deposition rates were predicted using a unique particle kinetic energy and viscosity based ash deposition methodology whose validity was ascertained by comparing against deposition rate measurements for widely varying operating conditions and ash compositions in a lab-scale furnace. With a unique end-to-end combustion modeling methodology established and different simulation scenarios carried out, the results from our computational fluid dynamic (CFD) simulations in conjunction with the plant data summarized in this report were used to refine Microbeam Technology Incorporated’s MTI CSPI-CT Tool to predict and monitor fire-side ash deposition under a range of load conditions and fuel property variability in real time.

01 COAL, LIGNITE, AND PEAT↗

Wireless High-Temperature Sensor Network for smart boiler systems

This final project report describes the research data and findings. This project aims to develop a new wireless high-temperature sensor network for real-time continuous boiler condition monitoring in harsh environments. Such a wireless high-temperature sensor network enables network-based automatic temperature sensing and data collection, which combined with artificial intelligent (AI) algorithms allow the construction of smart boiler systems with boiling condition management and optimization for significant energy-saving and reliability improvement

42 ENGINEERING↗

Modular Staged Pressurized Oxy-Combustion (SPOC) Power Plant for Coal and Biomass – Integration of Combustor Boiler and DCC

Critical to the future of power generation is the development of a power plant that will be capable of flexible operation to meet the needs of the modern grid, providing resilient, low-emissions power to a grid that is increasingly seeing a large penetration of intermittent wind and solar. The modular Staged, Pressurized Oxy-Combustion (SPOC) process envisioned by and under development at Washington University in St. Louis (WUSTL) has the potential to achieve these goals. The process offers: 1) a modular plant design for improved operational flexibility; 2) fuel-staging combined with pressurized oxy-combustion, which leads to smaller plant size, higher plant efficiency, and lower cost for pollutant and greenhouse gas removal compared with traditional carbon-capture equipped coal power plants; and 3) small modular boilers and pollutant removal units that can be fabricated in shop and assembled on site, further reducing plant capital costs. Under DOE's support (DE-FE0031925), WUSTL is advancing the development of the critical components for the SPOC power plant, including the integrated combustion system and the direct contact cooler (DCC) from Technology Readiness Level (TRL) 4 to TRL-5, which would allow these technologies to be subsequently incorporated into a pilot plant. This talk will present an overview of the SPOC technology, CFD modeling and validation for burner and boiler development, and recent results to evaluate critical components for system integration needed to advance its TRL.

Magalhaes, Duarte↗

Robust Heat-Flux Sensors for Coal-Fired Boiler Extreme Environments

In this project, robust heat-flux measurement systems were developed. The heat-flux sensors utilize thermoelectric effects to directly transduce the heat-flux inputs to analog electrical voltage signals. They were constructed from dedicated materials that can withstand temperatures of at least 1000°C and maintain adequate performance at these conditions for prolonged periods of time. The proposed approaches took into account numerous considerations, including system cost, sensor head resilience, sensor footprint, data accuracy, response time, and maintenance requirements. Through modern thermoelectric materials design, methodical materials selection and rigorous testing in materials characterization labs and medium-scale fire research facilities, we have demonstrated functioning laboratory prototypes, upon which one could base industrial heat-flux sensing platforms capable of operating in the challenging high-temperature, corrosive environments of the boilers of coal-fired power plants. A distributed sensor array for heat-flux measurements throughout the furnace water-wall, the superheater area and the economizer coils can provide critical data for the power plant control systems to increase efficiency, improve safety and reduce down times. For example, the combined heat-flux sensor/control systems can contribute to the optimization of burner and boiler operations under flexible loads, the optimization of heat-exchange conditions and overall reduction of heat rate and emissions, the prediction of imminent overheating conditions, and the optimization of the soot-blowing protocols.

20 FOSSIL-FUELED POWER PLANTS↗