Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM SCANNERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Design improvements to the SNS ion source and diagnostics

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world's most intense pulsed-neutron beams to a wide array of instruments which are used to conduct investigations in many fields of science and engineering. The accelerator system is fed by an RF-driven, multicusp, H - ion source which nominally provides pulsed beam currents of 50-60 mA (1ms, 60Hz). This report provides a discussion of ongoing design improvements to the SNS ion source and Low Energy Beam Transport (LEBT) as well as diagnostic upgrades undertaken since the previous ICIS conference. These improvements include (i) simple mechanical modifications to the source outlet aperture which resulted in dramatically increased extracted beam current and comparable or lower emittance at similar beam currents, (ii) design improvements to the LEBT chopper target which will enable full power beam-dumping during physics studies, (iii) refinement of the SNS Allison emittance scanner that has enabled the first reliable LEBT beam measurements at full beam power (65kV, 50-100mA, 1ms, 60Hz) on the SNS ion source test stand and (iv) the implementation of a thermal imaging camera for the monitoring the LEBT electrode temperatures. (v) The design of an advanced Cs system, capable of more efficient Cs utilization with significantly lower Cs losses from the source is also presented. Mechanical details, computational simulations and experimental results are discussed within the context of these improvements.

47 OTHER INSTRUMENTATION↗

Emittance Measurements with Wire Scanners in the Fermilab Side-coupled Linac

The Fermilab Side-Coupled Linac accelerates H-beam from 116 MeV to 400 MeV through seven 805 MHz modules. Twelve wire scanners are present in the Side Coupled Linac and four are present in the transfer line between the Linac and the Booster synchrotron ring. These wire scanners act as important diagnostic instruments to directly collect information on the beam's transverse distribution. The manipulation of the conditions of wire scanner data collection enables further characterization of the beamline, such as calculating emittance and the Twiss parameters of the beam at select regions, which we present here.

43 PARTICLE ACCELERATORS↗

Emittance Measurements with Wire Scanners in the Fermilab Side-Coupled Linac

The Fermilab Side-Coupled Linac accelerates H- beam from 116 MeV to 400 MeV through seven 805 MHz modules. Twelve wire scanners are present in the Side Coupled Linac and four are present in the transfer line between the Linac and the Booster synchrotron ring. These wire scanners act as important diagnostic instru-ments to directly collect information on the beam s transverse distribution. The manipulation of the condi-tions of wire scanner data collection enables further characterization of the beamline, such as calculating emittance and the Twiss parameters of the beam at select regions. Here we present the results of these studies and characterization of the non-Gaussian transverse beam distribution observed.

43 PARTICLE ACCELERATORS↗

TU-F-CAMPUS-I-02: Validation of a CT X-Ray Source Characterization Technique for Dose Computation Using An Anthropomorphic Thorax Phantom

Purpose: To experimentally validate a rotational kV x-ray source characterization technique by computing CT dose in an anthropomorphic thorax phantom using an in-house dose computation algorithm (kVDoseCalc). Methods: The lateral variation in incident energy spectra of a GE Optima big bore CT scanner was found by measuring the HVL along the internal, full bow-tie filter axis. The HVL and kVp were used to generate the x-ray spectra using Spektr software, while beam fluence was derived by dividing the integral product of the spectra and in-air mass-energy absorption coefficients by in-air dose measurements along the bow-tie filter axis. Beams produced by the GE Optima scanner were modeled at 80 and 140 kVp tube settings. kVDoseCalc calculates dose by solving the linear Boltzmann transport equation using a combination of deterministic and stochastic methods. Relative doses in an anthropomorphic thorax phantom (E2E SBRT Phantom) irradiated by the GE Optima scanner were measured using a (0.015 cc) PTW Freiburg ionization chamber, and compared to computations from kVDoseCalc. Results: The agreement in relative dose between dose computation and measurement for points of interest (POIs) within the primary path of the beam was within experimental uncertainty for both energies, however points outside the primary beam were not. The average absolute percent difference for POIs within the primary path of the beam was 1.37% and 5.16% for 80 and 140 kVp, respectively. The minimum and maximum absolute percent difference for both energies and all POIs within the primary path of the beam was 0.151% and 6.41%, respectively. Conclusion: The CT x-ray source characterization technique based on HVL measurements and kVp can be used to accurately compute CT dose in an anthropomorphic thorax phantom.

60 APPLIED LIFE SCIENCES↗

A coherent light scanner for optical processing of large format transparencies

A laser scanner is discussed in which the scanning beam is random-access addressable and perpendicular to the image input plane and the irradiance of the scanned beam is controlled so that a constant average irradiance is maintained after passage through the image plane. The scanner's optical system and design are described, and its performance is evaluated. It is noted that with this scanner, data in the form of large-format transparencies can be processed without the expense, space, maintenance, and precautions attendant to the operation of a high-power laser with large-aperture collimating optics. It is shown that the scanned format as well as the diameter of the scanning beam may be increased by simple design modifications and that higher scan rates can be achieved at the expense of resolution by employing acousto-optic deflectors with different relay optics.

Callen, W. R.↗

Feasibility of RACT for 3D dose measurement and range verification in a water phantom

Purpose: The objective of this study is to establish the feasibility of using radiation-induced acoustics to measure the range and Bragg peak dose from a pulsed proton beam. Simulation studies implementing a prototype scanner design based on computed tomographic methods were performed to investigate the sensitivity to proton range and integral dose. Methods: Derived from thermodynamic wave equation, the pressure signals generated from the dose deposited from a pulsed proton beam with a 1 cm lateral beam width and a range of 16, 20, and 27 cm in water using Monte Carlo methods were simulated. The resulting dosimetric images were reconstructed implementing a 3D filtered backprojection algorithm and the pressure signals acquired from a 71-transducer array with a cylindrical geometry (30 × 40 cm) rotated over 2π about its central axis. Dependencies on the detector bandwidth and proton beam pulse width were performed, after which, different noise levels were added to the detector signals (using 1 μs pulse width and a 0.5 MHz cutoff frequency/hydrophone) to investigate the statistical and systematic errors in the proton range (at 20 cm) and Bragg peak dose (of 1 cGy). Results: The reconstructed radioacoustic computed tomographic image intensity was shown to be linearly correlated to the dose within the Bragg peak. And, based on noise dependent studies, a detector sensitivity of 38 mPa was necessary to determine the proton range to within 1.0 mm (full-width at half-maximum) (systematic error < 150 μm) for a 1 cGy Bragg peak dose, where the integral dose within the Bragg peak was measured to within 2%. For existing hydrophone detector sensitivities, a Bragg peak dose of 1.6 cGy is possible. Conclusions: This study demonstrates that computed tomographic scanner based on ionizing radiation-induced acoustics can be used to verify dose distribution and proton range with centi-Gray sensitivity. Realizing this technology into the clinic has the potential to significantly impact beam commissioning, treatment verification during particle beam therapy and image guided techniques.

07 ISOTOPE AND RADIATION SOURCES↗

Focusing laser scanner

Economical laser scanner assembled from commercially available components, modulates and scans focused laser beam over area up to 5.1 by 5.1 cm. Scanner gives resolution comparable to that of conventional television. Device is highly applicable to area of analog and digital storage and retrieval.

Callen, W. R.↗

Contextual modeling and Bayesian Optimization for Improved Injection at the Fermilab Booster

The Fermilab accelerator complex delivers high-intensity proton beams to serve the lab’s neutrino, muon, and fixed-target programs. A normal-conducting Linac accelerates H− beam to 400 MeV and injects into the Booster rapid cycling synchrotron via charge exchange, which accelerates protons to 8 GeV. Injection from the Linac into the Booster is a critical area for high-power performance of the Fermilab proton complex. The Booster is a high-intensity proton ring with extreme space-charge forces which necessitates precise control over the beam losses through the acceleration cycle. The main challenge for the reliability of Booster performance is compensating for drifting conditions in the beam from the Linac, which can drift daily in energy by up to O(1) MeV w.r.t. design. Drifts in Linac orbit and energy must be corrected to match the Booster, while simultaneously accommodating interdependent drifts in transverse and longitudinal beam quality. Operationally, compensation for these changes is addressed by manual tuning of the Linac output energy and/or Booster acceptance, which can be inefficient and time-consuming. This works describes contextual Bayesian Optimization for injection tuning that takes into account the state of Linac beam via information from instrumentation in the injection line (Beam position monitors (BPMs), beam loss monitors (BLMs), wire scanners for transverse profiles (WSs)), as well as RF cavity setting parameters from the Linac.

Sharankova, R. [Fermilab] (ORCID:000000027014593X)↗

Management of natural resources through automatic cartographic inventory

The author has identified the following significant results. Return beam vidicon and multispectral band scanner imagery will be correlated with existing vegetation and geologic maps of southern France and northern Spain to develop correspondence codes between map units and space data. Microclimate data from six stations, spectral measurements from a few meters to 2 km using ERTS-type filter and spectrometers, and leaf reflectance measurements will be obtained to assist in correlation studies.

Rey, P.↗

Scene correction (precision techniques) of ERTS sensor data using digital image processing techniques

Techniques have been developed, implemented, and evaluated to process ERTS Return Beam Vidicon (RBV) and Multispectral Scanner (MSS) sensor data using digital image processing techniques. The RBV radiometry has been corrected to remove shading effects, and the MSS geometry and radiometry have been corrected to remove internal and external radiometric and geometric errors. The results achieved show that geometric mapping accuracy of about one picture element RMS and two picture elements (maximum) can be achieved by the use of nine ground control points. Radiometric correction of MSS and RBV sensor data has been performed to eliminate striping and shading effects to about one count accuracy. Image processing times on general purpose computers of the IBM 370/145 to 168 class are in the range of 29 to 3.2 minutes per MSS scene (4 bands). Photographic images of the fully corrected and annotated scenes have been generated from the processed data and have demonstrated excellent quality and information extraction potential.

Bernstein, R.↗

ERTS-1, the spacecraft and its sensors

The basic objectives of the ERTS-1 mission are defined as follows: (1) to determine what data can be acquired from an orbiting satellite on the natural and cultural resources and on the environment; and (2) to develop and demonstrate the combination of data-acquisition procedures and interpretative techniques which can make this new knowledge available for use in the many facets of man's life. A general description of the satellite's observatory system and its sensors is given, including the thermal control subsystem, the power subsystem, the attitude control subsystem, the orbit adjust subsystem, the telemetry and tracking systems, the communications and data handling subsystem, the return beam vidicon subsystem, the multispectral scanner subsystem, the two wideband video tape recorders, and the data collection subsystem.

Weiland, S.↗

Improved LANDSAT to give better view of earth resources

The launch data of LANDSAT 3 is announced. The improved capability of the spacecrafts' remote sensors (the return beam vidicon and the multispectral scanner) and application of LANDSAT data to the study of energy supplies, food production, and global large-scale environmental monitoring are discussed along with the piggyback amateur radio communication satellite-OSCAR-D, the plasma Interaction Experiment, and the data collection system onboard LANDSAT 3. An assessment of the utility of LANDSAT multispectral data is given based on the research results to data from studies of LANDSAT 1 and 2 data. Areas studied include agriculture, rangelands, forestry, water resources, environmental and marine resources, environmental and marine resources, cartography, land use, demography, and geological surveys and mineral/petroleum exploration.

Source record↗

An evaluation of the first four LANDSAT-D thematic mapper reflective sensors for monitoring vegetation: A comparison with other satellite sensor systems

The first four LANDSAT-D thematic mapper sensors were evaluated and compared to: the return beam vidicon (RBV) and multispectral scanners (MSS) sensors from LANDSATS 1, 2, and 3; Colvocoresses' proposed 'operational LANDSAT' three band system; and the French SPOT three band system using simulation/intergration techniques and in situ collected spectral reflectance data. Sensors were evaluated by their ability to discriminate vegetation biomass, chlorophyll concentration, and leaf water content. The thematic mapper and SPOT bands were found to be superior in a spectral resolution context to the other three sensor systems for vegetational applications. Significant improvements are expected for most vegetational analyses from LANDSAT-D thematic mapper and SPOT imagery over MSS and RBV imagery.

Tucker, C. J.↗

Use of spaceborne imaging radar in regional geomorphic studies

In the past two decades, the use of both photographic and non-photographic remote sensing from satellite platforms has provided a unique capability for the observation and study of Earth and planetary surfaces. A wide range of imaging sensors that operate in different portions of the electromagnetic spectrum have yielded images of large areas that formerly were unknown or that had not previously been observed at a simultaneous instant in time. In addition, remote sensors equipped with multispectral or multiband capabilities are capable of taking data at different wavelengths simultaneously. Notable examples include the LANDSAT series of multispectral scanners, thematic mappers, and return beam vidicons. Synthetic aperture radar and LANDSAT imagery are discussed.

Ford, J. P.↗

Stratified Diffractive Optic Approach for Creating High Efficiency Gratings

Gratings with high efficiency in a single diffracted order can be realized with both volume holographic and diffractive optical elements. However, each method has limitations that restrict the applications in which they can be used. For example, high efficiency volume holographic gratings require an appropriate combination of thickness and permittivity modulation throughout the bulk of the material. Possible combinations of those two characteristics are limited by properties of currently available materials, thus restricting the range of applications for volume holographic gratings. Efficiency of a diffractive optic grating is dependent on its approximation of an ideal analog profile using discrete features. The size of constituent features and, consequently, the number that can be used within a required grating period restricts the applications in which diffractive optic gratings can be used. These limitations imply that there are applications which cannot be addressed by either technology. In this paper we propose to address a number of applications in this category with a new method of creating high efficiency gratings which we call stratified diffractive optic gratings. In this approach diffractive optic techniques are used to create an optical structure that emulates volume grating behavior. To illustrate the stratified diffractive optic grating concept we consider a specific application, a scanner for a space-based coherent wind lidar, with requirements that would be difficult to meet by either volume holographic or diffractive optic methods. The lidar instrument design specifies a transmissive scanner element with the input beam normally incident and the exiting beam deflected at a fixed angle from the optical axis. The element will be rotated about the optical axis to produce a conical scan pattern. The wavelength of the incident beam is 2.06 microns and the required deflection angle is 30 degrees, implying a grating period of approximately 4 microns. Creating a high efficiency volume grating with these parameters would require a grating thickness that cannot be attained with current photosensitive materials. For a diffractive optic grating, the number of binary steps necessary to produce high efficiency combined with the grating period requires feature sizes and alignment tolerances that are also unattainable with current techniques. Rotation of the grating and integration into a space-based lidar system impose the additional requirements that it be insensitive to polarization orientation, that its mass be minimized and that it be able to withstand launch and space environments.

Chambers, Diana M.↗

G-LiHT: Goddard's LiDAR, Hyperspectral and Thermal Airborne Imager

Scientists at NASA's Goddard Space Flight Center have developed an ultra-portable, low-cost, multi-sensor remote sensing system for studying the form and function of terrestrial ecosystems. G-LiHT integrates two LIDARs, a 905 nanometer single beam profiler and 1550 nm scanner, with a narrowband (1.5 nanometers) VNIR imaging spectrometer and a broadband (8-14 micrometers) thermal imager. The small footprint (approximately 12 centimeters) LIDAR data and approximately 1 meter ground resolution imagery are advantageous for high resolution applications such as the delineation of canopy crowns, characterization of canopy gaps, and the identification of sparse, low-stature vegetation, which is difficult to detect from space-based instruments and large-footprint LiDAR. The hyperspectral and thermal imagery can be used to characterize species composition, variations in biophysical variables (e.g., photosynthetic pigments), surface temperature, and responses to environmental stressors (e.g., heat, moisture loss). Additionally, the combination of LIDAR optical, and thermal data from G-LiHT is being used to assess forest health by sensing differences in foliage density, photosynthetic pigments, and transpiration. Low operating costs (approximately $1 ha) have allowed us to evaluate seasonal differences in LiDAR, passive optical and thermal data, which provides insight into year-round observations from space. Canopy characteristics and tree allometry (e.g., crown height:width, canopy:ground reflectance) derived from G-LiHT data are being used to generate realistic scenes for radiative transfer models, which in turn are being used to improve instrument design and ensure continuity between LiDAR instruments. G-LiHT has been installed and tested in aircraft with fuselage viewports and in a custom wing-mounted pod that allows G-LiHT to be flown on any Cessna 206, a common aircraft in use throughout the world. G-LiHT is currently being used for forest biomass and growth estimation in the CONUS and Mexico in support of NASA's Carbon Monitoring System (CMS) and AMIGA-Carb (AMerican Icesat Glas Assessment of Carbon). For NASA's CMS, wall-to-wall G-LiHT data have been acquired over intensive study sites with historic LiDAR datasets, dense inventory data, stem maps and flux tower observations. For AMIGA-Carb, G-LiHT transects have been acquired over ICESat tracks and USDA-FS inventory plots throughout the CONUS, and similar data will be acquired in Mexico during 2013. This talk will highlight recent science results from continental-scale transects landscape-scale deployments of G-LiHT, as well as seasonal forest dynamics from repeat pass G-LiHT acquisitions.

Cook, Bruce↗

Compact adaptive optic-optical coherence tomography system

Badal Optometer and rotating cylinders are inserted in the AO-OCT to correct large spectacle aberrations such as myopia, hyperopic and astigmatism for ease of clinical use and reduction. Spherical mirrors in the sets of the telescope are rotated orthogonally to reduce aberrations and beam displacement caused by the scanners. This produces greatly reduced AO registration errors and improved AO performance to enable high order aberration correction in a patient eyes.

47 OTHER INSTRUMENTATION↗

Compact adaptive optic-optical coherence tomography system

Badal Optometer and rotating cylinders are inserted in the AO-OCT to correct large spectacle aberrations such as myopia, hyperopic and astigmatism for ease of clinical use and reduction. Spherical mirrors in the sets of the telescope are rotated orthogonally to reduce aberrations and beam displacement caused by the scanners. This produces greatly reduced AO registration errors and improved AO performance to enable high order aberration correction in a patient eyes.

47 OTHER INSTRUMENTATION↗