Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM ACCEPTANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Computational simulations and beamline optimizations for an electron beam degrader at CEBAF

An electron beam degrader is under development with the objective of measuring the transverse and longitudinal acceptance of the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. This project is in support of the CE+BAF positron capability. Computational simulations of beam-target interactions and particle tracking were performed integrating the GEANT4 and Elegant toolkits. A solenoid was added to the setup to control the beam's divergence. Parameter optimization of the solenoid field and magnetic quadrupoles gradient was also performed to further reduce particle loss through the rest of the injector beamline.

Lizárraga-Rubio, V.↗

Design and simulation of the nuSTORM facility

This thesis provides a full design and simulation of the nuSTORM beam line facility including the pion beam line , the pion and muon orbit combination section, and the muon decay ring. The study also includes the development of numerical optimization methods and their application to the design. At nuSTORM, one proton batch from the Main Injector (MI) is extracted and transported to the target station to bombard a solid target. A magnetic horn is used as the collection device for the secondary particles such as pions and kaons. A pion beam line is designed to transport the secondary particles downstream to the muon decay ring. In order to avoid the use of a fast kicker with a large aperture for the injection, an Orbit Combination Section (OCS) was designed to combine the reference pion orbit with the circulating muon orbit. This ful lls the stochastic injection scheme proposed in the 1980s. It is shown through the simulation that the pion beam line is able to deliver 0.011 muons per proton on target within the acceptance of the ring. In order to improve the circulating muon ux, an optimization of the magnetic collection horn was studied. A Multi-Objective Genetic Algorithm (MOGA), that was modi ed to integrate Message Passing Interface (MPI) in the process, is applied to the optimization. The number of muons within the ring acceptance from the pion decay is estimated by the pions after the collection horn. This new method was proposed to lower the requirement on the computing resources for the optimization. The study gives a new and better target and horn con guration after a full investigation of the system. The nuSTORM ring is examined with two optics designs. With di erent features, the two designs are optimized via correcting the nonlinearities with sextupolar eld distribution in the ring. A modi ed MPI-based Simulated Annealing (SA) algorithm was applied to obtain the optimal ring acceptance. The comparison with the GA shows good agreements on the achieved optimal ring acceptance. The pion and muon beams at nuSTORM were simulated and yield avor-pure and precisely measurable neutrino beams, which can be used to provide a de nite statement about the existence of a sterile neutrino.

97 MATHEMATICS AND COMPUTING↗

BEAM DIAGNOSTICS USING BPM SIGNALS FROM INJECTED AND STORED BEAMS IN A STORAGE RING

Many modern light sources are operating in top-off injection mode or are being upgraded to top-off injection mode. The storage ring always has the stored beam and injected beam for top-off injection mode. So the BPM data is the mixture of both beam positions and the injected beam position cannot be measured directly. We propose to use dedicated wide band BPM electronics in the NSLS II storage ring to retrieve the injected beam trajectory with the singular value decomposition (SVD) method. The beam position monitor (BPM) has the capability to measure bunch-by-bunch beam position. Similar electronics can be used to measure the bunch-by-bunch beam current which is necessary to get the injection beam position. The measurement precision of current needs to be evaluated since button BPM sum signal has position dependence. The injected beam trajectory can be measured and monitored all the time without dumping the stored beam. We can adjust and optimize the injected beam trajectory to maximize the injection efficiency. We can also measure the storage ring acceptance by mapping the injected beam trajectory.

43 PARTICLE ACCELERATORS↗

Theoretical Limits of Damping Attainable by Smart Beams with Rate Feedback

Using a generally accepted model we present a comprehensive analysis (within the page limitation) of an Euler- Bernoulli beam with PZT sensor-actuator and pure rate feedback. The emphasis is on the root locus - the dependence of the attainable damping on the feedback gain. There is a critical value of the gain beyond which the damping decreases to zero. We construct the time-domain response using semigroup theory, and show that the eigenfunctions form a Riesz basis, leading to a 'modal' expansion.

Balakrishnan, A. V.↗

The EMMA Project

EMMA stands for Electron Model of Muon Accelerator and is expected to demonstrate that a nonscaling FFAG can accelerate a beam quickly with large acceptance in both transverse and longitudinal directions, that is necessary for muon acceleration. We will study resonance crossing and outside bucket acceleration in detail. The concept of EMMA has been considered and designed over the last several years. Recently the project was funded and construction started at the STFC Daresbury Laboratory in April 2007. The first beam should be in the ring in summer 2009. We will discuss its backgrounds and aims, beam dynamics issues, and current hardware status.

43 PARTICLE ACCELERATORS↗

CONCEPT OF A POLARIZED POSITRON SOURCE FOR CEBAF

Positron beams would provide new and meaningful probes for the experimental program at the Thomas Jefferson National Accelerator Facility (JLab), including but not limited to future hadronic physics and dark matter experiments. Critical requirements involve generating positron beams with a high degree of spin polarization, sufficient intensity and a continuous-wave (CW) bunch train compatible with acceleration to 12 GeV at the Continuous Electron Beam Accelerator Facility (CEBAF). To address these requirements, a polarized positron injector based upon the bremsstrahlung of an intense CW spin polarized electron beam is considered*. First a polarized electron beam line provides >1 mA of polarized electrons at ~120 MeV to a high-power target for positron production. Next, a second beam line collects, shapes and aligns the spin of positrons for users. Finally, the positron beam is matched into the CEBAF acceptance for acceleration and transport to the end stations with energies up to 12 GeV. An optimized layout to provide positrons beams with intensity >100 nA (polarized) or intensity >3 µA (unpolarized) will be discussed in this poster.

Habet, S. H.↗

Plant Response to Microwaves at 2.45 GHz

One method of beaming to Earth energy captured by Space Solar Power (SSP) satellites is by using microwaves. Since microwaves are non-ioniz ing and of low energy they probably will have little or no direct eff ect (either long- or short-term) on terrestrial biota. This contentio n must to be proved however, before the public will accept a continuo us beam of microwaves being sent to the ground near populated areas or onto agricultural lands. To begin to address this question, an exper iment has been done that exposed an important agronomic plant speaes (alfalfa, Medicago sativa L.) to a continuous microwave beam at 2.45 GHz and from between 0.5 to 1.2 milli-watts per square centimeter. Th e hypothesis was that plants exposed to microwaves will be no differe nt from those control plants that were not exposed to microwaves. The microwaves were broadcast over a tray of mature, growing plants in the laboratory. The control plants were subjected to the same environme ntal conditions (light, temperature, soil and nutrients) minus the mi crowave exposure. Both populations of plants were watered as needed. As may be seen, the experiment was designed so that the only variable to which the test plants were subjected was microwave exposure. Prec ise, non-destructive measurements were taken of leaf chlorophyll concentration over the period of the experiment. Also measured were gross plant variables such as stem length, internodal distance, and, at the end of the experiment, above-ground biomass, both fresh and dry weig hts. Soil temperatures on bare soil and under the plant canopy were a lso measured. After seven weeks of exposure to microwaves there was n o sigruficant difference between control and test plant populations. A number of other plant/ microwave exposure studies will be discussed in this presentation. However, this experiment is one of the few publ ished examples of organisms being exposed to continuos microwave illu mination at one of the proposed SSP microwave frequencies and intensi ties.

Skiles, J. W.↗

Upgrade of the beam extraction system of the GTS-LHC electron cyclotron resonance ion source at CERN

Linac3 is the first accelerator in the heavy ion injector chain of the Large Hadron Collider (LHC), providing multiply charged heavy ion beams for the CERN experimental program. The ion beams are produced with GTS-LHC, a 14.5 GHz electron cyclotron resonance ion source, operated in afterglow mode. Improvement of the GTS-LHC beam formation and beam transport along Linac3 is part of the upgrade program of the injector chain in preparation for the future high luminosity LHC. A mismatch between the ion beam properties in the ion source extraction region and the acceptance of the following Low Energy Beam Transport (LEBT) section has been identified as one of the factors limiting the Linac3 performance. The installation of a new focusing element, an einzel lens, into the GTS-LHC extraction region is foreseen as a part of the Linac3 upgrade, as well as a redesign of the first section of the LEBT. Details of the upgrade and results of a beam dynamics study of the extraction region and LEBT modifications will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sci—Sat AM: Stereo — 06: Dosimetric Comparison of 3D Conformai, Flattened and Flattening Filter-Free TrueBeam RapidArc Planning for Lung SBRT

The major advantages of the VMAT SBRT plans compared to the conventional 3D conformai plan include faster delivery and improved target dose conformity. This study quantifies the dosimetric differences among 3D conformai plan; flattened beam and flattening filter-free (FFF) beam RapidArc Plans for lung SBRT. Five early stage lung cancer patients with various tumor positions and sizes previously treated with 3D non-coplanar SBRT were randomly selected. 4DCT was used for each patient to determine the internal target volume. Abdominal compression was applied to minimize respiratory motion for SBRT patients. For treatment planning, a 5 mm margin was given to the ITV to generate a planning target volume. The prescription dose was 48 Gy in 4 fractions and normalized to 95% of the PTV. Organs at risk (OAR) included spinal cord, esophagus, heart, trachea, bilateral lung, and great vessels. Optimization constraints were set to meet the criteria of the RTOG-0915 protocol. All VMAT plans were optimized with the RapidArc technique using two full arcs in Eclipse treatment planning system. The RapidArc SBRT plans with flattened 6MV beam and 6MV FFF beam were generated and dosimetric results were compared with the previous treated 3D non-coplanar plans. RapidArc plans demonstrated better conformity to target, sharper dose fall-off in normal tissues and lower dose to normal lung and other OARs than the 3D conformai plans. RapidArc SBRT for FFF beam showed comparable target conformity, adequate tumor dose, and clinically acceptable DVHs of OARs to flattened beams and significantly reduced treatment delivery time.

60 APPLIED LIFE SCIENCES↗

Beam-recoil polarization transfer in the nucleon resonance region in the exclusive e-vectorp{yields}e{sup '}K{sup +}{lambda}-vector and e-vectorp{yields}e{sup '}K{sup +}{sigma}-vector{sup 0} reactions at the CLAS spectrometer

Beam-recoil transferred polarizations for the exclusive e-vectorp{yields}e{sup '}K{sup +}{lambda}-vector,{sigma}-vector{sup 0} reactions have been measured using the Continuous Electron Beam Accelerator Facility's large acceptance spectrometer (CLAS) at the Thomas Jefferson National Accelerator Facility. New measurements have been completed at beam energies of 4.261 and 5.754 GeV that span a range of momentum transfer Q{sup 2} from 0.7 to 5.4 GeV{sup 2}, invariant energy W from 1.6 to 2.6 GeV, and the full center-of-mass angular range of the K{sup +} meson. These new data add to the existing CLAS K{sup +}{lambda} measurements at 2.567 GeV, and provide the first-ever data for the K{sup +}{sigma}{sup 0} channel in electroproduction. Comparisons of the data with several theoretical models are used to study the sensitivity to s-channel resonance contributions and the underlying reaction mechanism. Interpretations within two semiclassical partonic models are made to probe the underlying reaction mechanism and the ss quark-pair creation dynamics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

World-Wide Experience with SRF Facilities

The speaker will review and analyze the performance of existing SRF facilities in the world, addressing issues of usage and availability for different customers (HEP research, material sciences, ADS). Lessons learned should be summarized for proposed future facilities (ILC, Project X, Muon Collider). The first use of superconducting cavities for accelerating beams was at HEPL, Stanford University in the early sixties. Rather quickly, other laboratories followed suit, notably the University of Illinois at Champagne, Urbana and Cornell University. There were two main uses, which still persist today. The first is to provide accelerated particles as an injector or for fixed target experiments. The second is to maintain circulating beams, either for synchrotron light sources or for colliding beam experiments. Given the differing requirements, these two uses led to rather different implementations and, in particular, different average operating gradients. A second difference in the implementation is the speed of the particle being accelerated. Electrons are sufficiently relativistic at low beam energies (> {approx} 5 MeV) that cavities designed for relativistic beams can also function acceptably at low energy. This is not the case for protons or ion accelerators so, until recently, copper cavities were used to cover the first {approx} 100 MeV. Superconducting cavities are now also being proposed to cover this energy range as well using a series of superconducting cavities, each of which is matched to the particle velocity.

43 PARTICLE ACCELERATORS↗

ACCELERATOR CHALLENGES OF THE LHeC PROJECT

The LHeC project studies the design of a future electron-proton collider at CERN that will run in parallel to the standard LHC operation. For this purpose, the existing LHC storage ring will be combined with an Energy Recovery Linac (ERL), to accelerate electrons up to kinetic energy of 50 GeV. This concept - also applicable to the FCC-eh collider and studied at the PERLE project as prototype version - allows a peak luminosity of 10³⁴ cm⁻² s⁻¹. A sophisticated design of the RF structures, linacs, arcs, and interaction region is required. The electrons are accelerated and, after the interaction point, their energy is recovered through the same RF structures. While this energy recovery concept is a very promising approach, severe challenges are set by the layout of the interaction region, the beam separation concept and the design of the linac and arc lattice for the highest possible momentum acceptance. Emittance control and beam-beam effect of both, electron and proton beams, have been studied in front-to-end simulations and will be presented. We summarise the design principles of the ERL, the optimization of the arc lattice, and the main parameters of the project.

Holzer, B. J.↗

SU-F-J-110: MRI-Guided Single-Session Simulation, Online Adaptation, and Treatment

Purpose: To develop a combined simulation and treatment workflow for MRI-guided radiation therapy using the ViewRay treatment planning and delivery system. Methods: Several features of the ViewRay MRIdian planning and treatment workflows are used to simulate and treat patients that require emergent radiotherapy. A simple “pre-plan” is created on diagnostic imaging retrieved from radiology PACS, where conformal fields are created to target a volume defined by a physician based on review of the diagnostic images and chart notes. After initial consult in radiation oncology, the patient is brought to the treatment room, immobilized, and imaged in treatment position with a volumetric MR. While the patient rests on the table, the pre-plan is applied to the treatment planning MR and dose is calculated in the treatment geometry. After physician review, modification of the plan may include updating the target definition, redefining fields, or re-balancing beam weights. Once an acceptable treatment plan is finalized and approved, the patient is treated. Results: Careful preparation and judicious choices in the online planning process allow conformal treatment plans to be created and delivered in a single, thirty-minute session. Several advantages have been identified using this process as compared to conventional urgent CT simulation and delivery. Efficiency gains are notable, as physicians appreciate the predictable time commitment and patient waiting time for treatment is decreased. MR guidance in a treatment position offers both enhanced contrast for target delineation and reduction of setup uncertainties. The MRIdian system tools designed for adaptive radiotherapy are particularly useful, enabling plan changes to be made in minutes. Finally, the resulting plans, typically 6 conformal beams, are delivered as quickly as more conventional AP/PA beam arrangements with comparatively superior dose distributions. Conclusion: The ViewRay treatment planning software and delivery system can accommodate a fast simulation and treatment workflow.

60 APPLIED LIFE SCIENCES↗

Characterization and performance of the Silicon Vertex Tracker modules for the CLAS12 experiment

The Continuous Electron Beam Accelerator Facility's (CEBAF) Large Acceptance Spectrometer (CLAS) is being upgraded for the 12 GeV electron beam. The Silicon Vertex Tracker (SVT) will be part of the Central Tracker for the CLAS12 experiment and will be centered inside of the solenoid, which has 5 T magnetic field. We present the design, fabrication, characterization and performance of the SVT modules.

Gotra, Yuri↗

Neutronics Analyses for the Spallation Neutron Source Second Target Station

The Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR), two of the word-class neutron scattering facilities, are located at the Oak Ridge National Laboratory. The SNS and HFIR are funded by the U.S. Department of Energy, Office of Science, Office of Basic Energy Science, and are operated as user facilities, available to researchers from all over the world. Currently there are thirteen neutron scattering instruments in operation at the HFIR and twenty at the SNS First Target Station.Producing the cutting edge science requires continuous improvements and development of the facilities and instruments. The SNS was designed from the beginning to allow addition of the Second Target Station (STS), and an upgrade of the accelerator power. At this time both advances: the accelerator upgrade and the construction of the STS are in preparation.Current baseline design for the STS calls for a rotating compact tungsten target. The target station is driven with short (<1 μs) proton pulses at 10 Hz repetition rate and 467 kW proton beam power, and is optimized for high intensity and high resolution long wavelength neutron applications. The proton beam footprint as small as acceptable from the mechanical and heat removal aspects is planned to generate a compact-volume neutron production zone in the target, which is essential for tight coupling of the target and the moderators and for achieving high-intensity peak thermal and cold neutron fluxes. The STS will allow operation of approximately 22 beamlines and will expand and complement the current national neutron scattering capabilities.This paper will present an update of the status of the neutronics analyses performed for the STS and will discuss the performance of the moderators, heating rates, activation analyses, and shielding calculations which provide input in the engineering design.

Remec, Igor↗

Design, Fabrication and Concept for the Surface Treatment of the SRF Cavity Prototype for the CLIC Damping Rings

The Compact Linear Collider (CLIC) Damping Rings (DRs) need to generate ultra-low emittance bunches to achieve high luminosity in CLIC. This requires many wiggler magnets with big energy loss which is compensated by the Radio Frequency (RF) system. The resulting strong beam loading transients lead to a challenging design for the RF system. A novel SRF cavity at 2 GHz with an ultra-low R/Q parameter of below 1 Ω is proposed to minimize the transient beam loading effects below acceptable level. The design and fabrication of the bulk Nb prototype based on turning from a single piece of Nb and EB welding is presented. Moreover, conceptual study of the system for cavity surface treatment to achieve the highest surface magnetic field which is the main goal of the prototype cold test is described as well. To enable excellent performance in this cavity, we plan to apply the 75/120C modified low temperature bake in combination with the cold electropolishing process. This surface treatment approach has been shown to consistently deliver high accelerating gradients and improved quality factors in TESLA-shaped 1.3 GHz SRF cavities. By adapting and implementing this process for the 2 GHz ultra-low R/Q design, we aim to maximize the achievable surface magnetic field while minimizing residual resistance and field emission. This treatment strategy will be critical for demonstrating that the cavity can meet the demanding performance requirements of the CLIC damping ring RF system under high beam loading conditions.

Bafia, Daniel P. [Fermilab]↗

Electroexcitation of nucleon resonances from CLAS data on single pion electroproduction

We present results on the electroexcitation of the low mass resonances {delta}(1232)P{sub 33}, N(1440)P{sub 11}, N(1520)D{sub 13}, and N(1535)S{sub 11} in a wide range of Q{sup 2}. The results were obtained in the comprehensive analysis of data from the Continuous Electron Beam Accelerator Facility (CEBAF) large acceptance spectrometer (CLAS) detector at the Thomas Jefferson National Accelerator Facility (JLab) on differential cross sections, longitudinally polarized beam asymmetries, and longitudinal target and beam-target asymmetries for {pi} electroproduction off the proton. The data were analyzed using two conceptually different approaches--fixed-t dispersion relations and a unitary isobar model--allowing us to draw conclusions on the model sensitivity of the obtained electrocoupling amplitudes. The amplitudes for the {delta}(1232)P{sub 33} show the importance of a meson-cloud contribution to quantitatively explain the magnetic dipole strength, as well as the electric and scalar quadrupole transitions. They do not show any tendency of approaching the pQCD regime for Q{sup 2}{<=}6 GeV{sup 2}. For the Roper resonance, N(1440)P{sub 11}, the data provide strong evidence that this state is a predominantly radial excitation of a three-quark (3q) ground state. Measured in pion electroproduction, the transverse helicity amplitude for the N(1535)S{sub 11} allowed us to obtain the branching ratios of this state to the {pi}N and {eta}N channels via comparison with the results extracted from {eta} electroproduction. The extensive CLAS data also enabled the extraction of the {gamma}*p{yields}N(1520)D{sub 13} and N(1535)S{sub 11} longitudinal helicity amplitudes with good precision. For the N(1535)S{sub 11}, these results became a challenge for quark models and may be indicative of large meson-cloud contributions or of representations of this state that differ from a 3q excitation. The transverse amplitudes for the N(1520)D{sub 13} clearly show the rapid changeover from helicity-3/2 dominance at the real photon point to helicity-1/2 dominance at Q{sup 2}>1 GeV{sup 2}, confirming a long-standing prediction of the constituent quark model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗