Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Automatic Data Processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Automatic microseismic event picking via unsupervised machine learning

SUMMARY Effective and efficient arrival picking plays an important role in microseismic and earthquake data processing and imaging. Widely used short-term-average long-term-average ratio (STA/LTA) based arrival picking algorithms suffer from the sensitivity to moderate-to-strong random ambient noise. To make the state-of-the-art arrival picking approaches effective, microseismic data need to be first pre-processed, for example, removing sufficient amount of noise, and second analysed by arrival pickers. To conquer the noise issue in arrival picking for weak microseismic or earthquake event, I leverage the machine learning techniques to help recognizing seismic waveforms in microseismic or earthquake data. Because of the dependency of supervised machine learning algorithm on large volume of well-designed training data, I utilize an unsupervised machine learning algorithm to help cluster the time samples into two groups, that is, waveform points and non-waveform points. The fuzzy clustering algorithm has been demonstrated to be effective for such purpose. A group of synthetic, real microseismic and earthquake data sets with different levels of complexity show that the proposed method is much more robust than the state-of-the-art STA/LTA method in picking microseismic events, even in the case of moderately strong background noise.

Chen, Yangkang↗

THE COORDINATED RADIO AND INFRARED SURVEY FOR HIGH-MASS STAR FORMATION. II. SOURCE CATALOG

The CORNISH project is the highest resolution radio continuum survey of the Galactic plane to date. It is the 5 GHz radio continuum part of a series of multi-wavelength surveys that focus on the northern GLIMPSE region (10 Degree-Sign < l < 65 Degree-Sign ), observed by the Spitzer satellite in the mid-infrared. Observations with the Very Large Array in B and BnA configurations have yielded a 1.''5 resolution Stokes I map with a root mean square noise level better than 0.4 mJy beam{sup -1}. Here we describe the data-processing methods and data characteristics, and present a new, uniform catalog of compact radio emission. This includes an implementation of automatic deconvolution that provides much more reliable imaging than standard CLEANing. A rigorous investigation of the noise characteristics and reliability of source detection has been carried out. We show that the survey is optimized to detect emission on size scales up to 14'' and for unresolved sources the catalog is more than 90% complete at a flux density of 3.9 mJy. We have detected 3062 sources above a 7{sigma} detection limit and present their ensemble properties. The catalog is highly reliable away from regions containing poorly sampled extended emission, which comprise less than 2% of the survey area. Imaging problems have been mitigated by down-weighting the shortest spacings and potential artifacts flagged via a rigorous manual inspection with reference to the Spitzer infrared data. We present images of the most common source types found: H II regions, planetary nebulae, and radio galaxies. The CORNISH data and catalog are available online at http://cornish.leeds.ac.uk.

79 ASTRONOMY AND ASTROPHYSICS↗

Enabling modern data discovery for atmospheric measurements

The Atmospheric Radiation Measurement (ARM) user facility is a US Department of Energy Office of Science user facility that is managed and operated through a collaborative effort led by nine US Department of Energy national laboratories. The ARM Data Center, located at Oak Ridge National Laboratory, is responsible for the timely collection, processing, and delivery of data products to the scientific community. The ARM Data Center holds more than 11,000 data products, including metadata collected from field campaigns, instruments, value-added products, and principal investigator–contributed data. These data sets are checked for successful transfer (for most data, this transfer is carried out automatically via the network; however, some of the largest data sets and some of the most remote sites require manual shipping of hard disks) and both the data and metadata are processed to a standard format, which is an ARM-standardized structure, via the Network Common Data Form. The Network Common Data Form is a self-describing binary format with many compatible software tools. Once processed, the data are cataloged, stored in the ARM Data Archive, and made discoverable through association with an array of metadata-characterizing information, such as location and measurement classification. These metadata enable powerful search capabilities through the ARM Data Center Data Discovery interface. This paper discusses the workflow of how the new discovery system has been redesigned from user requirements and how the data are distributed to the scientific community.

54 ENVIRONMENTAL SCIENCES↗

Atmospheric parameters and metallicities for 2191 stars in the globular cluster M4

We report new metallicities for stars of Galactic globular cluster M4 using the largest number of stars ever observed at high spectral resolution in any cluster. We analyzed 7250 spectra for 2771 cluster stars gathered with the Very Large Telescope (VLT) FLAMES+GIRAFFE spectrograph at VLT. These medium-resolution spectra cover a small wavelength range, and often have very low signal-to-noise ratios. We approached this data set by reconsidering the whole method of abundance analysis of large stellar samples from beginning to end. We developed a new algorithm that automatically determines the atmospheric parameters of a star. Nearly all of the data preparation steps for spectroscopic analyses are processed on the syntheses, not the observed spectra. For 322 red giant branch (RGB) stars with V ≤ 14.7, we obtain a nearly constant metallicity, ([Fe/H]) = –1.07 (σ = 0.02). No difference in the metallicity at the level of 0.01 dex is observed between the two RGB sequences identified by Monelli et al. For 1869 subgiant and main-sequence stars with V > 14.7, we obtain ([Fe/H]) = –1.16 (σ = 0.09) after fixing the microturbulent velocity. These values are consistent with previous studies that have performed detailed analyses of brighter RGB stars at higher spectroscopic resolution and wavelength coverage. It is not clear if the small mean metallicity difference between brighter and fainter M4 members is real or is the result of the low signal-to-noise characteristics of the fainter stars. The strength of our approach is shown by recovering a metallicity close to a single value for more than 2000 stars, using a data set that is non-optimal for atmospheric analyses. This technique is particularly suitable for noisy data taken in difficult observing conditions.

79 ASTRONOMY AND ASTROPHYSICS↗

Eight new luminous z ≥ 6 quasars discovered via SED model fitting of VISTA, WISE and Dark Energy Survey Year 1 observations

We present the discovery and spectroscopic confirmation with the ESO NTT and Gemini South telescopes of eight new 6.0 < z < 6.5 quasars with z$_{AB}$ < 21.0. These quasars were photometrically selected without any star-galaxy morphological criteria from 1533 deg$^{2}$ using SED model fitting to photometric data from the Dark Energy Survey (g, r, i, z, Y), the VISTA Hemisphere Survey (J, H, K) and the Wide-Field Infrared Survey Explorer (W1, W2). The photometric data was fitted with a grid of quasar model SEDs with redshift dependent Lyman-{\alpha} forest absorption and a range of intrinsic reddening as well as a series of low mass cool star models. Candidates were ranked using on a SED-model based $\chi^{2}$-statistic, which is extendable to other future imaging surveys (e.g. LSST, Euclid). Our spectral confirmation success rate is 100% without the need for follow-up photometric observations as used in other studies of this type. Combined with automatic removal of the main types of non-astrophysical contaminants the method allows large data sets to be processed without human intervention and without being over run by spurious false candidates. We also present a robust parametric redshift estimating technique that gives comparable accuracy to MgII and CO based redshift estimators. We find two z $\sim$ 6.2 quasars with HII near zone sizes < 3 proper Mpc which could indicate that these quasars may be young with ages < 10$^6$ - 10$^7$ years or lie in over dense regions of the IGM. The z = 6.5 quasar VDESJ0224-4711 has J$_{AB}$ = 19.75 is the second most luminous quasar known with z > 6.5.

79 ASTRONOMY AND ASTROPHYSICS↗

Glycan Reader is improved to recognize most sugar types and chemical modifications in the Protein Data Bank

Motivation: Glycans play a central role in many essential biological processes. Glycan Reader was originally developed to simplify the reading of Protein Data Bank (PDB) files containing glycans through the automatic detection and annotation of sugars and glycosidic linkages between sugar units and to proteins, all based on atomic coordinates and connectivity information. Carbohydrates can have various chemical modifications at different positions, making their chemical space much diverse. Unfortunately, current PDB files do not provide exact annotations for most carbohydrate derivatives and more than 50% of PDB glycan chains have at least one carbohydrate derivative that could not be correctly recognized by the original Glycan Reader. Results: Glycan Reader has been improved and now identifies most sugar types and chemical modifications (including various glycolipids) in the PDB, and both PDB and PDBx/mmCIF formats are supported. CHARMM-GUI Glycan Reader is updated to generate the simulation system and input of various glycoconjugates with most sugar types and chemical modifications. It also offers a new functionality to edit the glycan structures through addition/deletion/modification of glycosylation types, sugar types, chemical modifications, glycosidic linkages, and anomeric states. The simulation system and input files can be used for CHARMM, NAMD, GROMACS, AMBER, GENESIS, LAMMPS, Desmond, OpenMM, and CHARMM/OpenMM. Glycan Fragment Database in GlycanStructure. Org is also updated to provide an intuitive glycan sequence search tool for complex glycan structures with various chemical modifications in the PDB.

Park, Sang-Jun↗

Serial crystallography with multi-stage merging of thousands of images

KAMO and BLEND provide particularly effective tools to automatically manage the merging of large numbers of data sets from serial crystallography. The requirement for manual intervention in the process can be reduced by extending BLEND to support additional clustering options such as the use of more accurate cell distance metrics and the use of reflection-intensity correlation coefficients to infer `distances' among sets of reflections. This increases the sensitivity to differences in unit-cell parameters and allows clustering to assemble nearly complete data sets on the basis of intensity or amplitude differences. If the data sets are already sufficiently complete to permit it, one applies KAMO once and clusters the data using intensities only. When starting from incomplete data sets, one applies KAMO twice, first using unit-cell parameters. In this step, either the simple cell vector distance of the original BLEND or the more sensitive NCDist is used. This step tends to find clusters of sufficient size such that, when merged, each cluster is sufficiently complete to allow reflection intensities or amplitudes to be compared. One then uses KAMO again using the correlation between reflections with a common hkl to merge clusters in a way that is sensitive to structural differences that may not have perturbed the unit-cell parameters sufficiently to make meaningful clusters. Many groups have developed effective clustering algorithms that use a measurable physical parameter from each diffraction still or wedge to cluster the data into categories which then can be merged, one hopes, to yield the electron density from a single protein form. Since these physical parameters are often largely independent of one another, it should be possible to greatly improve the efficacy of data-clustering software by using a multi-stage partitioning strategy. Here, one possible approach to multi-stage data clustering is demonstrated. The strategy is to use unit-cell clustering until the merged data are sufficiently complete and then to use intensity-based clustering. Using this strategy, it is demonstrated that it is possible to accurately cluster data sets from crystals that have subtle differences.

36 MATERIALS SCIENCE↗

Flexible Learning-Free Segmentation and Reconstruction of Neural Volumes

Imaging is a dominant strategy for data collection in neuroscience, yielding stacks of images that often scale to gigabytes of data for a single experiment. Machine learning algorithms from computer vision can serve as a pair of virtual eyes that tirelessly processes these images, automatically detecting and identifying microstructures. Unlike learning methods, our Flexible Learning-free Reconstruction of Imaged Neural volumes (FLoRIN) pipeline exploits structure-specifc contextual clues and requires no training. This approach generalizes across diferent modalities, including serially-sectioned scanning electron microscopy (sSEM) of genetically labeled and contrast enhanced processes, spectral confocal refectance (SCoRe) microscopy, and high-energy synchrotron X-ray microtomography (μCT) of large tissue volumes. We deploy the FLoRIN pipeline on newly published and novel mouse datasets, demonstrating the high biological fdelity of the pipeline’s reconstructions. FLoRIN reconstructions are of sufcient quality for preliminary biological study, for example examining the distribution and morphology of cells or extracting single axons from functional data. Compared to existing supervised learning methods, FLoRIN is one to two orders of magnitude faster and produces high-quality reconstructions that are tolerant to noise and artifacts, as is shown qualitatively and quantitatively.

47 OTHER INSTRUMENTATION↗

Publisher Correction: Flexible Learning-Free Segmentation and Reconstruction of Neural Volumes

Imaging is a dominant strategy for data collection in neuroscience, yielding stacks of images that often scale to gigabytes of data for a single experiment. Machine learning algorithms from computer vision can serve as a pair of virtual eyes that tirelessly processes these images, automatically detecting and identifying microstructures. Unlike learning methods, our Flexible Learning-free Reconstruction of Imaged Neural volumes (FLoRIN) pipeline exploits structure-specific contextual clues and requires no training. This approach generalizes across different modalities, including serially-sectioned scanning electron microscopy (sSEM) of genetically labeled and contrast enhanced processes, spectral confocal reflectance (SCoRe) microscopy, and high-energy synchrotron X-ray microtomography (μCT) of large tissue volumes. We deploy the FLoRIN pipeline on newly published and novel mouse datasets, demonstrating the high biological fidelity of the pipeline’s reconstructions. FLoRIN reconstructions are of sufficient quality for preliminary biological study, for example examining the distribution and morphology of cells or extracting single axons from functional data. Compared to existing supervised learning methods, FLoRIN is one to two orders of magnitude faster and produces high-quality reconstructions that are tolerant to noise and artifacts, as is shown qualitatively and quantitatively.

Shahbazi, Ali↗

An online application to measue the dispersion function in AGS

The measurement of the AGS dispersion function is one of the requirements for the development of an accurate online model of the AGS. Currently the zgoubi and the MADX online models of the AGS are employed as online models to set up and view the beam optics of the AGS using the model viewer. In this technical note we describe the method we employ to measure the numerical values of the dispersion function of the AGS at the location of the Beam Position Monitors (BPM’s) and we explain in detail the automatic process to measure experimentally the dispersion function of AGS at the location of the BPM’s. This automatic method of measuring the dispersion of the AGS not only reduces dramatically the time required to collect and analyze the experimental data to calculate the dispersion of the AGS, but also minimizes the possible human error that may occur in the process of the dispersion measurement.

43 PARTICLE ACCELERATORS↗

Natural Language Processing-Enhanced Nuclear Industry Operating Experience Data Analysis: Aggregation and Interpretation of Multi-Report Analysis Results

Industry-wide operating experience is a critical source of raw data for reliability and risk model parameter estimations for nuclear power plants. A large portion of operating experience data are failure events stored as reports that contain unstructured data, such as narratives. In current practice, a failure report is usually reviewed and manually coded by analysts. The coding is based on extracting several event characteristics such as system name, component type, sub-part type, failure mode, and failure cause. Event narratives are mostly used to help understand events and extract their characteristics. In this line of research, we aim to maximize the usage of event narratives by leveraging natural language processing (NLP) methods to automatically convert an event narrative to a causal graph. This research has promise to improve physical understanding of failure initiation and propagation and to facilitate use of non-failure data (e.g., near-misses and degradations) to complement the limited data pool of failures. In our previous work, we developed an NLP tool and applied it to analyze a number of licensee event reports submitted by U.S. nuclear power plants to the Nuclear Regulatory Commission. In this paper, we will report our recent research progress in aggregating the results of multiple reports, developing network model(s), and drawing statistical insights.

99 GENERAL AND MISCELLANEOUS↗

PySIDT: Subgraph Isomorphic Decision Trees for Molecular Property Prediction

Accurate molecular property prediction is important across all fields of chemistry. Deep neural networks (DNNs) have become increasingly popular due to their ability to train automatically, avoiding the incredibly tedious process of constructing and extending traditional property estimation schemes. However, DNNs require large amounts of training data, are challenging to interpret, require large amounts of memory to load even during inference, and have severe difficulties incorporating qualitative chemical knowledge, which are often desired for molecular property prediction tasks. Here, in this study, we present PySIDT (https://github.com/zadorlab/PySIDT), a software for training and running inference on Subgraph Isomorphic Decision Trees (SIDTs). SIDTs are graph-based decision trees made of nodes associated with molecular substructures. Inference is done by descending target molecular structures down the decision tree to nodes with matching subgraph isomorphic substructures and making predictions based on the final (most specific) nodes matched. SIDTs scale down well to dataset sizes much smaller than is feasible for DNNs. As trees of molecular substructures, SIDTs are inherently readable and easy to visualize, making them easy to analyze. They are also straightforward to extend and retrain, facilitate uncertainty estimation, and enable easy integration of expert knowledge. We demonstrate the SIDT approach discussing its application to a diverse range of molecular prediction tasks: rate coefficient estimation, diffusion coefficient estimation, thermochemistry estimation, transition state bond stretch prediction, p K a prediction, stability of molecular structures, stability of surface structures, and prediction of surface lateral interaction energetics. Additionally, we demonstrate the power of the SIDT algorithms in two direct learning curve vanilla comparisons with the popular DNN-based software Chemprop and the popular gradient boosted trees-based software XGBoost on enthalpy of formation and rate coefficient prediction tasks. In particular, in the enthalpy of formation case, vanilla PySIDT is able to outperform vanilla Chemprop and XGBoost across the full range of training/validation set sizes out to 11,560 data points.

Johnson, Matthew Sean [Sandia National Laboratorie↗

WE-A-17A-03: Catheter Digitization in High-Dose-Rate Brachytherapy with the Assistance of An Electromagnetic (EM) Tracking System

Purpose: To investigate the use of a system using EM tracking, postprocessing and error-detection algorithms for measuring brachytherapy catheter locations and for detecting errors and resolving uncertainties in treatment-planning catheter digitization. Methods: An EM tracker was used to localize 13 catheters in a clinical surface applicator (A) and 15 catheters inserted into a phantom (B). Two pairs of catheters in (B) crossed paths at a distance <2 mm, producing an undistinguishable catheter artifact in that location. EM data was post-processed for noise reduction and reformatted to provide the dwell location configuration. CT-based digitization was automatically extracted from the brachytherapy plan DICOM files (CT). EM dwell digitization error was characterized in terms of the average and maximum distance between corresponding EM and CT dwells per catheter. The error detection rate (detected errors / all errors) was calculated for 3 types of errors: swap of two catheter numbers; incorrect catheter number identification superior to the closest position between two catheters (mix); and catheter-tip shift. Results: The averages ± 1 standard deviation of the average and maximum registration error per catheter were 1.9±0.7 mm and 3.0±1.1 mm for (A) and 1.6±0.6 mm and 2.7±0.8 mm for (B). The error detection rate was 100% (A and B) for swap errors, mix errors, and shift >4.5 mm (A) and >5.5 mm (B); errors were detected for shifts on average >2.0 mm (A) and >2.4 mm (B). Both mix errors associated with undistinguishable catheter artifacts were detected and at least one of the involved catheters was identified. Conclusion: We demonstrated the use of an EM tracking system for localization of brachytherapy catheters, detection of digitization errors and resolution of undistinguishable catheter artifacts. Automatic digitization may be possible with a registration between the imaging and the EM frame of reference. Research funded by the Kaye Family Award 2012.

07 ISOTOPE AND RADIATION SOURCES↗

Performance and automatic calibration scheme of the waveform sampler in the ETROC2 ASIC chip

The waveform sampler in the CMS ETROC2 chip for LGAD gain aging monitoring is a 2.56-GS/s 12-bit 8x-Interleaved ADC that consists of a coarse SAR stage, and a fine stage. This architecture delivers high performance on a relatively modest 65 nm process, while requires finding up to 24 calibration constants through calibration. We developed an automatic calibration method using charge injection test data. After calibration, the baseline random error is reduced by a factor of 2.5–3 compared to the default calibration, and a 5% charge measurement precision is achieved in 15 fC charge injection tests.

Fu, Tao [Unlisted, US]↗

Enhanced FIB-SEM systems for large-volume 3D imaging

Focused Ion Beam Scanning Electron Microscopy (FIB-SEM) can automatically generate 3D images with superior z-axis resolution, yielding data that needs minimal image registration and related post-processing. Obstacles blocking wider adoption of FIB-SEM include slow imaging speed and lack of long-term system stability, which caps the maximum possible acquisition volume. Here, we present techniques that accelerate image acquisition while greatly improving FIB-SEM reliability, allowing the system to operate for months and generating continuously imaged volumes > 10 6 ?m 3 . These volumes are large enough for connectomics, where the excellent z resolution can help in tracing of small neuronal processes and accelerate the tedious and time-consuming human proofreading effort. Even higher resolution can be achieved on smaller volumes. We present example data sets from mammalian neural tissue, Drosophila brain, and Chlamydomonas reinhardtii to illustrate the power of this novel high-resolution technique to address questions in both connectomics and cell biology.

59 BASIC BIOLOGICAL SCIENCES↗

Smart Semi-Supervised Accumulation of Large Repositories for Industrial Control Systems Device Information

Industrial Control Systems device manufacturers frequently add new features to improve their product performance. Oftentimes, these changes are mainly vendor-driven initiatives, and customers may not be aware of the full impact of these new capabilities on their cybersecurity posture. In the energy sector, this can lead to considerable dissonance between vendor-provided cybersecurity claims and a customer’s responsibility for Operation Technology cybersecurity compliance. Thus, the resulting dynamic verification burden is shifted towards the customer and may pose a significant cybersecurity risk to the energy sector landscape. We found that there is very limited research into cybersecurity auditing for Operational Technology. However, a solution is needed for vetting the vendor-supplied feature claims and their adherence to cybersecurity requirements and standards. We are presently engaged in an effort to develop such a system. This paper demonstrates one vital aspect of this effort in proposing an end-to-end framework to accumulate a large repository of ICS device information for this vetting system, curate the dataset, and conduct extensive processing. This framework is designed to use web scraping, data analytics and Natural Language Processing (NLP) techniques to identify vendor websites, automate the collection of website-accessible documents and automatically derive metadata from them for identification of product documents relevant to the repository. We have found that this automated approach to vendor identification, document extraction into a product repository, and NLP pre-processing is unique and has not been previously presented in the literature. The preliminary work shows that this is feasible and can produce reliable results with minimum supervision. Future work will be built upon this foundation in order to achieve semi-supervised vetting of device technical information – a vital capability for ensuring that vendor-claimed device cybersecurity capabilities match industry requirements.

Ameri, Kimia↗

Applications of Autonomous Data Collection and Active Learning

Advances in sensors and robotics have dramatically improved the diversity of experimental approaches available to the materials community. Autonomous data collection platforms, either custom-made or commercially available, provide researchers with novel tools with which to probe materials behavior and perform advanced materials characterization. The application of novel control algorithms and active learning approaches can create much more robust experimental data, or can be used to improve the performance of existing characterization tools. Five papers within this special topic focus on experimental and computational methodologies for use in automatic data collection routines for materials characterization. From novel platforms for materials discovery to new statistical frameworks for assessing the autonomous experimentation process, these five papers highlight the diverse range of applications of automation for advancing materials science.

36 MATERIALS SCIENCE↗

Automatic Digitization and Orientation of Scanned Mesh Data for Floor Plan and 3D Model Generation

This paper describes a novel approach for generating accurate floor plans and 3D models of building interiors using scanned mesh data. Unlike previous methods, which begin with a high resolution point cloud from a laser range-finder, our approach begins with triangle mesh data, as from a Microsoft HoloLens. It generates two types of floor plans, a “pen-and-ink” style that preserves details and a drafting-style that reduces clutter. It processes the 3D model for use in applications by aligning it with coordinate axes, annotating important objects, dividing it into stories, and removing the ceiling. Its performance is evaluated on commercial and residential buildings, with experiments to assess quality and dimensional accuracy. Our approach demonstrates promising potential for automatic digitization and orientation of scanned mesh data, enabling floor plan and 3D model generation in various applications such as navigation, interior design, furniture placement, facilities management, building construction, and HVAC design.

Sharma, Ritesh↗