Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Automatic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

2011 Status of the Automatic Alignment System for the National Ignition Facility

Automated alignment for the National Ignition Facility (NIF) is accomplished using a large-scale parallel control system that directs 192 laser beams along the 300-m optical path. The beams are then focused down to a 50-micron spot in the middle of the target chamber. The entire process is completed in less than 50 minutes. The alignment system commands 9,000 stepping motors for highly accurate adjustment of mirrors and other optics. 41 control loops per beamline perform parallel processing services running on a LINUX cluster to analyze high-resolution images of the beams and their references. This paper describes the status the NIF automatic alignment system and the challenges encountered as NIF development has transitioned from building the laser, to becoming a research project supporting a 24 hour, 7 day laser facility. NIF is now a continuously operated system where performance monitoring is increasingly more critical for operation, maintenance, and commissioning tasks. Equipment wear and the effects of high energy neutrons from fusion experiments are issues which alter alignment efficiency and accuracy. New sensors needing automatic alignment assistance are common. System modifications to improve efficiency and accuracy are prevalent. Handling these evolving alignment and maintenance needs while minimizing the impact on NIF experiment schedule is expected to be an on-going challenge for the planned 30 year operational life of NIF.

42 ENGINEERING↗

Dentalmaps: Automatic Dental Delineation for Radiotherapy Planning in Head-and-Neck Cancer

Purpose: To propose an automatic atlas-based segmentation framework of the dental structures, called Dentalmaps, and to assess its accuracy and relevance to guide dental care in the context of intensity-modulated radiotherapy. Methods and Materials: A multi-atlas-based segmentation, less sensitive to artifacts than previously published head-and-neck segmentation methods, was used. The manual segmentations of a 21-patient database were first deformed onto the query using nonlinear registrations with the training images and then fused to estimate the consensus segmentation of the query. Results: The framework was evaluated with a leave-one-out protocol. The maximum doses estimated using manual contours were considered as ground truth and compared with the maximum doses estimated using automatic contours. The dose estimation error was within 2-Gy accuracy in 75% of cases (with a median of 0.9 Gy), whereas it was within 2-Gy accuracy in 30% of cases only with the visual estimation method without any contour, which is the routine practice procedure. Conclusions: Dose estimates using this framework were more accurate than visual estimates without dental contour. Dentalmaps represents a useful documentation and communication tool between radiation oncologists and dentists in routine practice. Prospective multicenter assessment is underway on patients extrinsic to the database.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic Segmentation and Online virtualCT in Head-and-Neck Adaptive Radiation Therapy

Purpose: The purpose of this work was to develop and validate an efficient and automatic strategy to generate online virtual computed tomography (CT) scans for adaptive radiation therapy (ART) in head-and-neck (HN) cancer treatment. Method: We retrospectively analyzed 20 patients, treated with intensity modulated radiation therapy (IMRT), for an HN malignancy. Different anatomical structures were considered: mandible, parotid glands, and nodal gross tumor volume (nGTV). We generated 28 virtualCT scans by means of nonrigid registration of simulation computed tomography (CTsim) and cone beam CT images (CBCTs), acquired for patient setup. We validated our approach by considering the real replanning CT (CTrepl) as ground truth. We computed the Dice coefficient (DSC), center of mass (COM) distance, and root mean square error (RMSE) between correspondent points located on the automatically segmented structures on CBCT and virtualCT. Results: Residual deformation between CTrepl and CBCT was below one voxel. Median DSC was around 0.8 for mandible and parotid glands, but only 0.55 for nGTV, because of the fairly homogeneous surrounding soft tissues and of its small volume. Median COM distance and RMSE were comparable with image resolution. No significant correlation between RMSE and initial or final deformation was found. Conclusion: The analysis provides evidence that deformable image registration may contribute significantly in reducing the need of full CT-based replanning in HN radiation therapy by supporting swift and objective decision-making in clinical practice. Further work is needed to strengthen algorithm potential in nGTV localization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Whole-Cell Scan using Automatic Variable-Angle and Variable-Illumination-Depth Pseudo—Total Internal Reflection Fluorescence Microscopy

An automatic calibration and angle-scanning prism-type total internal reflection fluorescence microscope (TIRFM) was modified to function in both TIRFM and pseudo-TIRFM modes. When the incident angle of the excitation laser beam was controlled to be larger than the critical angle, the instrument served as a variable-angle TIRFM. A homemade computer program automatically calibrates the laser illumination spot in the sample to overlap with the center of the microscope's field of view. Then, by measuring the fluorescence intensities at different incident angles, the z-positions of fluorescent nanospheres close to the cell basolateral membrane can be extracted. When the incident angle is reduced to be in the subcritical range, the instrument works as a pseudo-TIRFM. The whole cell body from bottom to top can be imaged in a vertical scan process. Furthermore, the illumination field depth in the pseudo-TIRFM can be controlled by changing the incident angle or the horizontal position of the laser spot.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An algorithm for automatic identification of double twin variants in Mg alloys

Highlights: • An algorithm for automatic identification of {10–11}–{10–12} double twin variants is proposed. • This algorithm is applicable for the cases without knowing the primary twin orientations. • The primary twin orientations can be reconstructed using this algorithm. - Abstract: {10 1-bar 1}−{10 1-bar 2} double twins (DTs) are profuse in Mg alloys after rolling at a large reduction (>10%). In many cases, the secondary twins completely occupy the primary ones, causing difficulty in variant analysis. Here, we propose an algorithm for automatic identification of twin variants. This is applicable for the {10 1-bar 1}−{10 1-bar 2} DTs without knowing the primary twins. In addition, two kinds of stereographic projections are constructed to assist such variant selection. By this method, the variants of 67 DTs observed in a rolled AZ31 sheet are determined. Based on 14 sets of DTs with known primary twin orientations, the high efficiency and reliability of this proposed algorithm is verified. The reason for unreliable variant identification in two special cases is also discussed.

36 MATERIALS SCIENCE↗

RU-net for automatic characterization of TRISO fuel cross sections

During irradiation, phenomena such as kernel swelling and buffer densification may impact the performance of tristructural isotropic (TRISO) particle fuel. Post-irradiation microscopy is often used to identify these irradiation-induced morphologic changes. However, each fuel compact generally contains thousands of TRISO particles. Manually performing the work to get statistical information on these phenomena is cumbersome and subjective. Here, to reduce the subjectivity inherent in that process and to accelerate data analysis, we used convolutional neural networks (CNNs) to automatically segment cross-sectional images of microscopic TRISO layers. CNNs are a class of machine-learning algorithms specifically designed for processing structured grid data. They have gained popularity in recent years due to their remarkable performance in various computer vision tasks, including image classification, object detection, and image segmentation. In this research, we generated a large irradiated TRISO layer dataset with more than 2,000 microscopic images of cross-sectional TRISO particles and the corresponding annotated images. Based on these annotated images, we used different CNNs to automatically segment different TRISO layers. These CNNs include RU-Net (developed in this study), as well as three existing architectures: U-Net, Residual Network (ResNet), and Attention U-Net. The preliminary results show that the model based on RU-Net performs best in terms of Intersection over Union (IoU). Using CNN models, we can expedite the analysis of TRISO particle cross sections, significantly reducing the manual labor involved and improving the objectivity of the segmentation results.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Scripting in Radiation Therapy: An Automatic 3D Beam-Naming System

Scripts can be executed within the radiation treatment planning software framework to reduce human error, increase treatment planning efficiency, reduce confusion, and promote consistency within an institution or even among institutions. Scripting is versatile, and one application is an automatic 3D beam-naming system that describes the position of the beam relative to the patient in 3D space. The naming system meets the need for nomenclature that is conducive for clear and accurate communication of beam entry relative to patient anatomy. In radiation oncology in particular, where miscommunication can cause significant harm to patients, a system that minimizes error is essential. Frequent sharing of radiation treatment information occurs not only among members within a department but also between different treatment centers. Descriptions of treatment beams are perhaps the most commonly shared information about a patient's course of treatment in radiation oncology. Automating the naming system by the use of a script reduces the potential for human error, improves efficiency, enforces consistency, and would allow an institution to convert to a new naming system with greater ease. This script has been implemented in the Department of Radiation Oncology at the University of Washington Medical Center since December 2009. It is currently part of the dosimetry protocol and is accessible by medical dosimetrists, radiation oncologists, and medical physicists. This paper highlights the advantages of using an automatic 3D beam-naming script to flawlessly and quickly identify treatment beams with unique names. Scripting in radiation treatment planning software has many uses and great potential for improving clinical care.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mining Software Usage with the Automatic Library Tracking Database (ALTD)

Tracking software usage is important for HPC centers, computer vendors, code developers and funding agencies to provide more efficient and targeted software support, and to forecast needs and guide HPC software effort towards the Exascale era. However, accurately tracking software usage on HPC systems has been a challenging task. In this paper, we present a tool called Automatic Library Tracking Database (ALTD) that has been developed and put in production on several Cray systems. The ALTD infrastructure prototype automatically and transparently stores information about libraries linked into an application at compilation time and also the executables launched in a batch job. We will illustrate the usage of libraries, compilers and third party software applications on a system managed by the National Institute for Computational Sciences.

97 MATHEMATICS AND COMPUTING↗

Building a Simplistic Automatic Extruder: Instrument Development Opportunities for the Laboratory

This work presents an automatic extruder as a research experience for undergraduate students. The system offers a user-friendly approach to preparing vesicles, such as liposomes or polymersomes, with a defined size and polydispersity properties crucial for research in biology and macromolecules. It comprises two syringe pumps connected by a membrane filter. The setup is controlled by software. Compared to manual extrusion, this automated system provides advantages, such as precisely controlled variables. The project describes a tool to enhance undergraduate learning in science and engineering laboratories. Building an automatic extruder serves as a simplified model of a complex industrial process. It offers a clear advantage: automating a well-understood manual extrusion process. To make this project accessible, it is broken down into three manageable tasks: software development, hardware assembly, and testing procedures. This breakdown describes the software created, the hardware components used, and the testing procedures conducted for this project. All project data, including software code, testing data, and procedures, are freely available online. This allows undergraduate students to not only begin their own projects but also contribute to this educational instrument’s ongoing development.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ab initio wavenumber accurate spectroscopy : {sup 1}CH{sub 2} and HCN vibrational levels on automatically generated IMLS potential energy surfaces.

We report here calculated J = 0 vibrational frequencies for {sup 1}CH{sub 2} and HCN with root-mean-square error relative to available measurements of 2.0 cm{sup -1} and 3.2 cm{sup -1}, respectively. These results are obtained with DVR calculations with a dense grid on ab initio potential energy surfaces (PESs). The ab initio electronic structure calculations employed are Davidson-corrected MRCI calculations with double-, triple-, and quadruple-{zeta} basis sets extrapolated to the complete basis set (CBS) limit. In the {sup 1}CH{sub 2} case, Full CI tests of the Davidson correction at small basis set levels lead to a scaling of the correction with the bend angle that can be profitably applied at the CBS limit. Core-valence corrections are added derived from CCSD(T) calculations with and without frozen cores. Relativistic and non-Born-Oppenheimer corrections are available for HCN and were applied. CBS limit CCSD(T) and CASPT2 calculations with the same basis sets were also tried for HCN. The CCSD(T) results are noticeably less accurate than the MRCI results while the CASPT2 results are much poorer. The PESs were generated automatically using the local interpolative moving least-squares method (L-IMLS). A general triatomic code is described where the L-IMLS method is interfaced with several common electronic structure packages. All PESs were computed with this code running in parallel on eight processors. The L-IMLS method provides global and local fitting error measures important in automatically growing the PES from initial ab initio seed points. The reliability of this approach was tested for {sup 1}CH{sub 2} by comparing DVR-calculated vibrational levels on an L-IMLS ab initio surface with levels generated by an explicit ab initio calculation at each DVR grid point. For all levels ({approx}200) below 20000 cm{sup -1}, the mean unsigned difference between the levels of these two calculations was 0.1 cm{sup -1}, consistent with the L-IMLS estimated mean unsigned fitting error of 0.3 cm{sup -1}. All L-IMLS PESs used in this work have comparable mean unsigned fitting errors, implying that fitting errors have a negligible role in the final errors of the computed vibrational levels with experiment. Less than 500 ab initio calculations of the energy and gradients are required to achieve this level of accuracy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WPEC SG50: Developing an Automatically Readable, Comprehensive and Curated Experimental Nuclear Reaction Database

The Organisation for Economic Co-operation and Development (OECD) Nuclear Energy Agency (NEA) Working Party on International Nuclear Data Evaluation Co-operation (WPEC) subgroup (SG) 50 was formed in 2020 to develop an automatically readable, comprehensive and curated experimental nuclear reaction database. This database is called MEDUSAL (Machine-readable Experimental Data User Application & Library), and will draw from EXFOR. The EXFOR database preserves experimental nuclear reaction data true to its original documentation and information from the authors of the data. MEDUSAL will deviate from EXFOR by storing additional information from users of the data for their fields of work (evaluation, model development, validation, etc.). This includes expert judgment on the data sets, identification of data points as outliers, renormalization of the data to the newest monitor reactions, and estimations of missing uncertainty sources. The format for MEDUSAL is being developed to enable easy automatic parsing of large amounts of data. Here, we will summarize the use cases, high-level requirements and first steps towards developing the database MEDUSAL and the API to access it.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Automatic Lane-Level Road Network Extraction from Aerial Imagery for Transportation Digital Twins

Accurate road networks are essential for credible traffic microsimulation and transportation digital twins, yet high-definition maps are often difficult to obtain due to limited availability, high cost, or proprietary restrictions. Some build networks from crowdsourced data, such as OpenStreetMap, but these sources often contain geometric and semantic inconsistencies. Others create networks manually, a process that is labor-intensive and difficult to scale. To address these limitations, this work presents an end-to-end pipeline that automatically extracts georeferenced, lane-level road networks from publicly available high-resolution satellite imagery and converts them into simulation-ready assets. The developed end-to-end pipeline has three primary modules: (1) A computer-vision-based module first detects directed lane geometries and intersection layouts. (2) A heuristic-based topology construction module then identifies approach and exit legs and establishes conflict-free lane-to-lane connections. (3) Finally, an automatic simulation-building module converts the extracted network into standard formats, e.g., OpenDRIVE, and generates routable SUMO networks. The framework supports both complete network construction from scratch and local-scale refinement of existing networks through lane-count correction, transition recovery, and geometric regularization. The proposed pipeline provides a practical pathway to generate traffic simulation networks from satellite imagery, significantly reducing manual reconstruction effort and enabling scalable, continuously updated transportation digital twins.

Guo, Hetian [University of Georgia, Athens] (ORCID↗

Using a MaxEnt Classifier for the Automatic Content Scoring of Free-Text Responses

Criticisms against multiple-choice item assessments in the USA have prompted researchers and organizations to move towards constructed-response (free-text) items. Constructed-response (CR) items pose many challenges to the education community - one of which is that they are expensive to score by humans. At the same time, there has been widespread movement towards computer-based assessment and hence, assessment organizations are competing to develop automatic content scoring engines for such items types - which we view as a textual entailment task. This paper describes how MaxEnt Modeling is used to help solve the task. MaxEnt has been used in many natural language tasks but this is the first application of the MaxEnt approach to textual entailment and automatic content scoring.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Automatic energy calibration algorithm for an RBS setup

This work describes a computer algorithm for automatic extraction of the energy calibration parameters from a Rutherford Back-Scattering Spectroscopy (RBS) spectrum. Parameters like the electronic gain, electronic offset and detection resolution (FWHM) of a RBS setup are usually determined using a standard sample. In our case, the standard sample comprises of a multi-elemental thin film made of a mixture of Ti-Al-Ta that is analyzed at the beginning of each run at defined beam energy. A computer program has been developed to extract automatically the calibration parameters from the spectrum of the standard sample. The code evaluates the first derivative of the energy spectrum, locates the trailing edges of the Al, Ti and Ta peaks and fits a first order polynomial for the energy-channel relation. The detection resolution is determined fitting the convolution of a pre-calculated theoretical spectrum. To test the code, data of two years have been analyzed and the results compared with the manual calculations done previously, obtaining good agreement.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automatic computer procedure for generating exact and analytical kinetic energy operators based on the polyspherical approach: General formulation and removal of singularities

We present new techniques for an automatic computation of the kinetic energy operator in analytical form. These techniques are based on the use of the polyspherical approach and are extended to take into account Cartesian coordinates as well. An automatic procedure is developed where analytical expressions are obtained by symbolic calculations. This procedure is a full generalization of the one presented in Ndong et al., [J. Chem. Phys. 136, 034107 (2012)]. The correctness of the new implementation is analyzed by comparison with results obtained from the TNUM program. We give several illustrations that could be useful for users of the code. In particular, we discuss some cyclic compounds which are important in photochemistry. Among others, we show that choosing a well-adapted parameterization and decomposition into subsystems can allow one to avoid singularities in the kinetic energy operator. We also discuss a relation between polyspherical and Z-matrix coordinates: this comparison could be helpful for building an interface between the new code and a quantum chemistry package.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance of automatic scanning microscope for nuclear emulsion experiments

The impressive improvements in scanning technology and methods let nuclear emulsion to be used as a target in recent large experiments. We report the performance of an automatic scanning microscope for nuclear emulsion experiments. After successful calibration and alignment of the system, we have reached 99% tracking efficiency for the minimum ionizing tracks that penetrating through the emulsions films. The automatic scanning system is successfully used for the scanning of emulsion films in the OPERA experiment and plan to use for the next generation of nuclear emulsion experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A diagrammatic approach for automatically deriving analytical gradients of tensor hyper-contracted electronic structure methods

In this work, we introduce a diagrammatic approach to facilitate the automatic derivation of analytical nuclear gradients for tensor hyper-contraction (THC) based electronic structure methods. The automatically derived gradients are guaranteed to have the same scaling in terms of both operation count and memory footprint as the underlying energy calculations, and the computation of a gradient is roughly three times as costly as the underlying energy. The new diagrammatic approach enables the first cubic scaling implementation of nuclear derivatives for THC tensors fitted in molecular orbital basis (MO-THC). Furthermore, application of this new approach to THC-MP2 analytical gradients leads to an implementation, which is at least four times faster than the previously reported, manually derived implementation. Finally, we apply the new approach to the 14 tensor contraction patterns appearing in the supporting subspace formulation of multireference perturbation theory, laying the foundation for developments of analytical nuclear gradients and nonadiabatic coupling vectors for multi-state CASPT2.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automatic classification of time-variable X-ray sources

To maximize the discovery potential of future synoptic surveys, especially in the field of transient science, it will be necessary to use automatic classification to identify some of the astronomical sources. The data mining technique of supervised classification is suitable for this problem. Here, we present a supervised learning method to automatically classify variable X-ray sources in the Second XMM-Newton Serendipitous Source Catalog (2XMMi-DR2). Random Forest is our classifier of choice since it is one of the most accurate learning algorithms available. Our training set consists of 873 variable sources and their features are derived from time series, spectra, and other multi-wavelength contextual information. The 10 fold cross validation accuracy of the training data is ∼97% on a 7 class data set. We applied the trained classification model to 411 unknown variable 2XMM sources to produce a probabilistically classified catalog. Using the classification margin and the Random Forest derived outlier measure, we identified 12 anomalous sources, of which 2XMM J180658.7–500250 appears to be the most unusual source in the sample. Its X-ray spectra is suggestive of a ultraluminous X-ray source but its variability makes it highly unusual. Machine-learned classification and anomaly detection will facilitate scientific discoveries in the era of all-sky surveys.

79 ASTRONOMY AND ASTROPHYSICS↗