Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Automatic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

MO-G-BRE-04: Automatic Verification of Daily Treatment Deliveries and Generation of Daily Treatment Reports for a MR Image-Guided Treatment Machine

Purpose: Two aims of this work were to develop a method to automatically verify treatment delivery accuracy immediately after patient treatment and to develop a comprehensive daily treatment report to provide all required information for daily MR-IGRT review. Methods: After systematically analyzing the requirements for treatment delivery verification and understanding the available information from a novel MR-IGRT treatment machine, we designed a method to use 1) treatment plan files, 2) delivery log files, and 3) dosimetric calibration information to verify the accuracy and completeness of daily treatment deliveries. The method verifies the correctness of delivered treatment plans and beams, beam segments, and for each segment, the beam-on time and MLC leaf positions. Composite primary fluence maps are calculated from the MLC leaf positions and the beam-on time. Error statistics are calculated on the fluence difference maps between the plan and the delivery. We also designed the daily treatment delivery report by including all required information for MR-IGRT and physics weekly review - the plan and treatment fraction information, dose verification information, daily patient setup screen captures, and the treatment delivery verification results. Results: The parameters in the log files (e.g. MLC positions) were independently verified and deemed accurate and trustable. A computer program was developed to implement the automatic delivery verification and daily report generation. The program was tested and clinically commissioned with sufficient IMRT and 3D treatment delivery data. The final version has been integrated into a commercial MR-IGRT treatment delivery system. Conclusion: A method was developed to automatically verify MR-IGRT treatment deliveries and generate daily treatment reports. Already in clinical use since December 2013, the system is able to facilitate delivery error detection, and expedite physician daily IGRT review and physicist weekly chart review.

60 APPLIED LIFE SCIENCES↗

SU-E-J-29: Automatic Image Registration Performance of Three IGRT Systems for Prostate Radiotherapy

Purpose: To compare the performance of an automatic image registration algorithm on image sets collected on three commercial image guidance systems, and explore its relationship with imaging parameters such as dose and sharpness. Methods: Images of a CIRS Virtually Human Male Pelvis phantom (VHMP) were collected on the CBCT systems of Varian TrueBeam/OBI and Elekta Synergy/XVI linear accelerators, across a range of mAs settings; and MVCT on a Tomotherapy Hi-ART accelerator with a range of pitch. Using the 6D correlation ratio algorithm of XVI, each image was registered to a mask of the prostate volume with a 5 mm expansion. Registrations were repeated 100 times, with random initial offsets introduced to simulate daily matching. Residual registration errors were calculated by correcting for the initial phantom set-up error. Automatic registration was also repeated after reconstructing images with different sharpness filters. Results: All three systems showed good registration performance, with residual translations <0.5mm (1σ) for typical clinical dose and reconstruction settings. Residual rotational error had larger range, with 0.8°, 1.2° and 1.9° for 1σ in XVI, OBI and Tomotherapy respectively. The registration accuracy of XVI images showed a strong dependence on imaging dose, particularly below 4mGy. No evidence of reduced performance was observed at the lowest dose settings for OBI and Tomotherapy, but these were above 4mGy. Registration failures (maximum target registration error > 3.6 mm on the surface of a 30mm sphere) occurred in 5% to 10% of registrations. Changing the sharpness of image reconstruction had no significant effect on registration performance. Conclusions: Using the present automatic image registration algorithm, all IGRT systems tested provided satisfactory registrations for clinical use, within a normal range of acquisition settings.

60 APPLIED LIFE SCIENCES↗

SU-E-J-155: Automatic Quantitative Decision Making Metric for 4DCT Image Quality

Purpose: To develop a quantitative decision making metric for automatically detecting irregular breathing using a large patient population that received phase-sorted 4DCT. Methods: This study employed two patient cohorts. Cohort#1 contained 256 patients who received a phasesorted 4DCT. Cohort#2 contained 86 patients who received three weekly phase-sorted 4DCT scans. A previously published technique used a single abdominal surrogate to calculate the ratio of extreme inhalation tidal volume to normal inhalation tidal volume, referred to as the κ metric. Since a single surrogate is standard for phase-sorted 4DCT in radiation oncology clinical practice, tidal volume was not quantified. Without tidal volume, the absolute κ metric could not be determined, so a relative κ (κrel) metric was defined based on the measured surrogate amplitude instead of tidal volume. Receiver operator characteristic (ROC) curves were used to quantitatively determine the optimal cutoff value (jk) and efficiency cutoff value (τk) of κrel to automatically identify irregular breathing that would reduce the image quality of phase-sorted 4DCT. Discriminatory accuracy (area under the ROC curve) of κrel was calculated by a trapezoidal numeric integration technique. Results: The discriminatory accuracy of ?rel was found to be 0.746. The key values of jk and tk were calculated to be 1.45 and 1.72 respectively. For values of ?rel such that jk≤κrel≤τk, the decision to reacquire the 4DCT would be at the discretion of the physician. This accounted for only 11.9% of the patients in this study. The magnitude of κrel held consistent over 3 weeks for 73% of the patients in cohort#3. Conclusion: The decision making metric, ?rel, was shown to be an accurate classifier of irregular breathing patients in a large patient population. This work provided an automatic quantitative decision making metric to quickly and accurately assess the extent to which irregular breathing is occurring during phase-sorted 4DCT.

60 APPLIED LIFE SCIENCES↗

SU-E-T-596: P3DVHStats - a Novel, Automatic, Institution Customizable Program to Compute and Report DVH Quantities On Philips Pinnacle TPS

Purpose: To implement a novel, automatic, institutional customizable DVH quantities evaluation and PDF report tool on Philips Pinnacle treatment planning system (TPS) Methods: An add-on program (P3DVHStats) is developed by us to enable automatic DVH quantities evaluation (including both volume and dose based quantities, such as V98, V100, D2), and automatic PDF format report generation, for EMR convenience. The implementation is based on a combination of Philips Pinnacle scripting tool and Java language pre-installed on each Pinnacle Sun Solaris workstation. A single Pinnacle script provide user a convenient access to the program when needed. The activated script will first export DVH data for user selected ROIs from current Pinnacle plan trial; a Java program then provides a simple GUI interface, utilizes the data to compute any user requested DVH quantities, compare with preset institutional DVH planning goals; if accepted by users, the program will also generate a PDF report of the results and export it from Pinnacle to EMR import folder via FTP. Results: The program was tested thoroughly and has been released for clinical use at our institution (Pinnacle Enterprise server with both thin clients and P3PC access), for all dosimetry and physics staff, with excellent feedback. It used to take a few minutes to use MS-Excel worksheet to calculate these DVH quantities for IMRT/VMAT plans, and manually save them as PDF report; with the new program, it literally takes a few mouse clicks in less than 30 seconds to complete the same tasks. Conclusion: A Pinnacle scripting and Java language based program is successfully implemented, customized to our institutional needs. It is shown to dramatically reduce time and effort needed for DVH quantities computing and EMR reporting.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-F-CAMPUS-I-01: A System for Automatically Calculating Organ and Effective Dose for Fluoroscopically-Guided Procedures

Purpose: A system was developed that automatically calculates the organ and effective dose for individual fluoroscopically-guided procedures using a log of the clinical exposure parameters. Methods: We have previously developed a dose tracking system (DTS) to provide a real-time color-coded 3D- mapping of skin dose. This software produces a log file of all geometry and exposure parameters for every x-ray pulse during a procedure. The data in the log files is input into PCXMC, a Monte Carlo program that calculates organ and effective dose for projections and exposure parameters set by the user. We developed a MATLAB program to read data from the log files produced by the DTS and to automatically generate the definition files in the format used by PCXMC. The processing is done at the end of a procedure after all exposures are completed. Since there are thousands of exposure pulses with various parameters for fluoroscopy, DA and DSA and at various projections, the data for exposures with similar parameters is grouped prior to entry into PCXMC to reduce the number of Monte Carlo calculations that need to be performed. Results: The software developed automatically transfers data from the DTS log file to PCXMC and runs the program for each grouping of exposure pulses. When the dose from all exposure events are calculated, the doses for each organ and all effective doses are summed to obtain procedure totals. For a complicated interventional procedure, the calculations can be completed on a PC without manual intervention in less than 30 minutes depending on the level of data grouping. Conclusion: This system allows organ dose to be calculated for individual procedures for every patient without tedious calculations or data entry so that estimates of stochastic risk can be obtained in addition to the deterministic risk estimate provided by the DTS. Partial support from NIH grant R01EB002873 and Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

TU-AB-201-05: Automatic Adaptive Per-Operative Re-Planning for HDR Prostate Brachytherapy - a Simulation Study On Errors in Needle Positioning

Purpose: To develop adaptive planning with feedback for MRI-guided focal HDR prostate brachytherapy with a single divergent needle robotic implant device. After each needle insertion, the dwell positions for that needle are calculated and the positioning of remaining needles and dosimetry are both updated based on MR imaging. Methods: Errors in needle positioning may occur due to inaccurate needle insertion (caused by e.g. the needle’s bending) and unpredictable changes in patient anatomy. Consequently, the dose plan quality might dramatically decrease compared to the preplan. In this study, a procedure was developed to re-optimize, after each needle insertion, the remaining needle angulations, source positions and dwell times in order to obtain an optimal coverage (D95% PTV>19 Gy) without exceeding the constraints of the organs at risk (OAR) (D10% urethra<21 Gy, D1cc bladder<12 Gy and D1cc rectum<12 Gy). Complete HDR procedures with 6 needle insertions were simulated for a patient MR-image set with PTV, prostate, urethra, bladder and rectum delineated. Random angulation errors, modeled by a Gaussian distribution (standard deviation of 3 mm at the needle’s tip), were generated for each needle insertion. We compared the final dose parameters for the situations (I) without re-optimization and (II) with the automatic feedback. Results: The computation time of replanning was below 100 seconds on a current desk computer. For the patient tested, a clinically acceptable dose plan was achieved while applying the automatic feedback (median(range) in Gy, D95% PTV: 19.9(19.3–20.3), D10% urethra: 13.4(11.9–18.0), D1cc rectum: 11.0(10.7–11.6), D1cc bladder: 4.9(3.6–6.8)). This was not the case without re-optimization (median(range) in Gy, D95% PTV: 19.4(14.9–21.3), D10% urethra: 12.6(11.0–15.7), D1cc rectum: 10.9(8.9–14.1), D1cc bladder: 4.8(4.4–5.2)). Conclusion: An automatic guidance strategy for HDR prostate brachytherapy was developed to compensate errors in needle positioning and improve the dose distribution. Without re-optimization, target coverage and OAR constraints may not be achieved. M. Borot de Battisti is funded by Philips Medical Systems Nederland B.V.; M. Moerland is principal investigator on a contract funded by Philips Medical Systems Nederland B.V.; G. Hautvast and D. Binnekamp are full-time employees of Philips Medical Systems Nederland B.V.

60 APPLIED LIFE SCIENCES↗

TU-G-204-02: Automatic Sclerotic Bone Metastases Detection in the Pelvic Region From Dual Energy CT

Purpose: To automatically detect sclerotic bone metastases in the pelvic region using dual energy computed tomography (DECT). Methods: We developed a two stage algorithm to automatically detect sclerotic bone metastases in the pelvis from DECT for patients with multiple bone metastatic lesions and with hip implants. The first stage consists of extracting the bone and marrow regions by using a support vector machine (SVM) classifier. We employed a novel representation of the DECT images using multi-material decomposition, which represents each voxel as a mixture of different physical materials (e.g. bone+water+fat). Following the extraction of bone and marrow, in the second stage, a bi -histogram equalization method was employed to enhance the contrast to reveal the bone metastases. Next, meanshift segmentation was performed to separate the voxels by their intensity levels. Finally, shape-based filtering was performed to extract the possible locations of the metastatic lesions using multiple shape criteria. We used the following shape parameters: area, eccentricity, major and minor axis, perimeter and skeleton. Results: A radiologist with several years of experience with DECT manually labeled 64 regions consisting of metastatic lesions from 10 different patients. However, the patients had many more metastasic lesions throughout the pelvis. Our method correctly identified 46 of the marked 64 regions (72%). In addition, our method also identified several other lesions, which can then be validated by the radiologist. The missed lesions were typically very large elongated regions consisting of several islands of very small (<4mm) lesions. Conclusion: We developed an algorithm to automatically detect sclerotic lesions in the pelvic region from DECT. Preliminary assessment shows that our algorithm generated lesions agreeing with the radiologist generated candidate regions. Furthermore, our method reveals additional lesions that can be inspected by the radiologist, thereby, reducing radiologist effort in identifying all the lesions with poor contrast from the DECT images.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRA-05: Fully Automatic Segmentation of Male Pelvic Organs On CT Without Manual Intervention

Purpose: We aim to develop a fully automatic tool for accurate contouring of major male pelvic organs in CT images for radiotherapy without any manual initialization, yet still achieving superior performance than the existing tools. Methods: A learning-based 3D deformable shape model was developed for automatic contouring. Specifically, we utilized a recent machine learning method, random forest, to jointly learn both image regressor and classifier for each organ. In particular, the image regressor is trained to predict the 3D displacement from each vertex of the 3D shape model towards the organ boundary based on the local image appearance around the location of this vertex. The predicted 3D displacements are then used to drive the 3D shape model towards the target organ. Once the shape model is deformed close to the target organ, it is further refined by an organ likelihood map estimated by the learned classifier. As the organ likelihood map provides good guideline for the organ boundary, the precise contouring Result could be achieved, by deforming the 3D shape model locally to fit boundaries in the organ likelihood map. Results: We applied our method to 29 previously-treated prostate cancer patients, each with one planning CT scan. Compared with manually delineated pelvic organs, our method obtains overlap ratios of 85.2%±3.74% for the prostate, 94.9%±1.62% for the bladder, and 84.7%±1.97% for the rectum, respectively. Conclusion: This work demonstrated feasibility of a novel machine-learning based approach for accurate and automatic contouring of major male pelvic organs. It shows the potential to replace the time-consuming and inconsistent manual contouring in the clinic. Also, compared with the existing works, our method is more accurate and also efficient since it does not require any manual intervention, such as manual landmark placement. Moreover, our method obtained very similar contouring results as the clinical experts. Project is partially support by a grant from NCI 1R01CA140413.

60 APPLIED LIFE SCIENCES↗

SU-F-J-34: Automatic Target-Based Patient Positioning Framework for Image-Guided Radiotherapy in Prostate Cancer Treatment

Purpose: Current image-guided radiotherapy (IGRT) procedure is bonebased patient positioning, followed by subjective manual correction using cone beam computed tomography (CBCT). This procedure might cause the misalignment of the patient positioning. Automatic target-based patient positioning systems achieve the better reproducibility of patient setup. Our aim of this study was to develop an automatic target-based patient positioning framework for IGRT with CBCT images in prostate cancer treatment. Methods: Seventy-three CBCT images of 10 patients and 24 planning CT images with digital imaging and communications in medicine for radiotherapy (DICOM-RT) structures were used for this study. Our proposed framework started from the generation of probabilistic atlases of bone and prostate from 24 planning CT images and prostate contours, which were made in the treatment planning. Next, the gray-scale histograms of CBCT values within CTV regions in the planning CT images were obtained as the occurrence probability of the CBCT values. Then, CBCT images were registered to the atlases using a rigid registration with mutual information. Finally, prostate regions were estimated by applying the Bayesian inference to CBCT images with the probabilistic atlases and CBCT value occurrence probability. The proposed framework was evaluated by calculating the Euclidean distance of errors between two centroids of prostate regions determined by our method and ground truths of manual delineations by a radiation oncologist and a medical physicist on CBCT images for 10 patients. Results: The average Euclidean distance between the centroids of extracted prostate regions determined by our proposed method and ground truths was 4.4 mm. The average errors for each direction were 1.8 mm in anteroposterior direction, 0.6 mm in lateral direction and 2.1 mm in craniocaudal direction. Conclusion: Our proposed framework based on probabilistic atlases and Bayesian inference might be feasible to automatically determine prostate regions on CBCT images.

60 APPLIED LIFE SCIENCES↗

Automatic Residential/Commercial Classification of Parcels with Solar Panel Detections

A computational method to automatically detect solar panels on rooftops to aid policy and financial assessment of solar distributed generation. The code automatically classifies parcels containing solar panels in the U.S. as residential or commercial. The code allows the user to specify an input dataset containing parcels and detected solar panels, and then uses information about the parcels and solar panels to automatically classify the rooftops as residential or commercial using machine learning techniques. The zip file containing the code includes sample input and output datasets for the Boston and DC areas.

Morton, AprilM↗

Automatic Tuner for the Step Sizes of Gradient-Based RT-OPF DERMS Control Systems [SWR-22-50]

Gradient-based controllers have parameters called step sizes that determine how sensitive its control actions are to received inputs. Finding a practical setting for a step size is important. If it is too small, the controller is ineffective by not reacting in a significant manor to its received inputs. On the other hand, if it is too large, the actions implemented by the controller may be excessive and cause the controlled system to become unstable. The main objective of the Automatic Tuner for the Step Sizes of Gradient-Based RT-OPF DERMS Control Systems is to speed up the implementation of gradient-based control schemes by automatically tuning its step sizes instead of having a practitioner spend considerable time doing the task manually. Only simple adjustments need to be made to the code of each controller with a step size to allow the addition of an individual automatic tuner. This can be applied to any RT-OPF based control for DER management.

Comden, Joshua↗

Automatic inference of indexing rules for MEDLINE

Background: Indexing is a crucial step in any information retrieval system. In MEDLINE, a widely used database of the biomedical literature, the indexing process involves the selection of Medical Subject Headings in order to describe the subject matter of articles. The need for automatic tools to assist MEDLINE indexers in this task is growing with the increasing number of publications being added to MEDLINE. Methods: In this paper, we describe the use and the customization of Inductive Logic Programming (ILP) to infer indexing rules that may be used to produce automatic indexing recommendations for MEDLINE indexers. Results: Our results show that this original ILP-based approach outperforms manual rules when they exist. In addition, the use of ILP rules also improves the overall performance of the Medical Text Indexer (MTI), a system producing automatic indexing recommendations for MEDLINE. Conclusion: We expect the sets of ILP rules obtained in this experiment to be integrated into MTI.

59 BASIC BIOLOGICAL SCIENCES↗

Towards reverse mode automatic differentiation of Kokkos-based codes

Derivative computation is a key component of optimization, sensitivity analysis, uncertainty quantification, and the solving of nonlinear problems. Automatic differentiation (AD) is a powerful technique for evaluating such derivatives, and in recent years, has been integrated into programming environments such as Jax, PyTorch, and TensorFlow to support derivative computations needed for training of machine learning models, facilitating wide-spread use of these technologies. The C++ language has become the de facto standard for scientific computing due to numerous factors, yet language complexity has made the wide-spread adoption of AD technologies for C++ difficult, hampering the incorporation of powerful differentiable programming approaches into C++ scientific simulations. This is exacerbated by the increasing emergence of architectures, such as GPUs, with limited memory capabilities and requiring massive thread-level concurrency. C++ AD tools must effectively use these environments to bring novel scientific simulations to next-generation DOE experimental and observational facilities. In this project, we investigated source transformation-based automatic differentiation using LLVM compiler infrastructure to automatically generate portable and efficient gradient computations of Kokkos-based code. We have demonstrated that our proposed strategy is feasible by investigating the usage of a prototype LLVM-based source transformation tool to generate gradients of simple functions made of sequences of simple Kokkos parallel regions. Speedups of up to 500x compared to Sacado were observed on NVIDIA V100 GPU.

97 MATHEMATICS AND COMPUTING↗

Comparing Automatic CME Detections in Multiple LASCO and SECCHI Catalogs

With the creation of numerous automatic detection algorithms, a number of different catalogs of coronal mass ejections (CMEs) spanning the entirety of the Solar and Heliospheric Observatory ( SOHO ) Large Angle Spectrometric Coronagraph (LASCO) mission have been created. Some of these catalogs have been further expanded for use on data from the Solar Terrestrial Earth Observatory ( STEREO ) Sun Earth Connection Coronal and Heliospheric Investigation (SECCHI) as well. We compare the results from different automatic detection catalogs (Solar Eruption Event Detection System (SEEDS), Computer Aided CME Tracking (CACTus), and Coronal Image Processing (CORIMP)) to ensure the consistency of detections in each. Over the entire span of the LASCO catalogs, the automatic catalogs are well correlated with one another, to a level greater than 0.88. Focusing on just periods of higher activity, these correlations remain above 0.7. We establish the difficulty in comparing detections over the course of LASCO observations due to the change in the instrument image cadence in 2010. Without adjusting catalogs for the cadence, CME detection rates show a large spike in cycle 24, despite a notable drop in other indices of solar activity. The output from SEEDS, using a consistent image cadence, shows that the CME rate has not significantly changed relative to sunspot number in cycle 24. These data, and mass calculations from CORIMP, lead us to conclude that any apparent increase in CME rate is a result of the change in cadence. We study detection characteristics of CMEs, discussing potential physical changes in events between cycles 23 and 24. We establish that, for detected CMEs, physical parameters can also be sensitive to the cadence.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical automatic gain channel

Automatic Gain Control /AGC/ channel automatically compensates for gain changes in the azimuth error channel due to time varying optical sight degrading effects. This system is useful in remote television monitors, automatic navigation systems, and surveying and mapping instrumentation.

Mrus, G.↗

Flight test results from the CV990 simulated space shuttle during unpowered automatic approaches and landings

Unpowered automatic approaches and landings with a CV990 aircraft were conducted to study navigation, guidance, and control problems associated with terminal area approach and landing for the space shuttle. The flight tests were designed to study from 11,300 m to touchdown the performance of a navigation and guidance concept which utilized blended radio/inertial navigation using VOR, DME, and ILS as the ground navigation aids. In excess of fifty automatic approaches and landings were conducted. Preliminary results indicate that this concept may provide sufficient accuracy to accomplish automatic landing of the shuttle orbiter without air-breathing engines on a conventional size runway.

Edwards, F. G.↗

Image analysis techniques associated with automatic data base generation.

This paper considers some basic problems relating to automatic data base generation from imagery, the primary emphasis being on fast and efficient automatic extraction of relevant pictorial information. Among the techniques discussed are recursive implementations of some particular types of filters which are much faster than FFT implementations, a 'sequential similarity detection' technique of implementing matched filters, and sequential linear classification of multispectral imagery. Several applications of the above techniques are presented including enhancement of underwater, aerial and radiographic imagery, detection and reconstruction of particular types of features in images, automatic picture registration and classification of multiband aerial photographs to generate thematic land use maps.

Bond, A. D.↗

A manual-control approach to development of VTOL automatic landing technology.

The operation of VTOL aircraft in the city-center environment will require complex landing-approach trajectories that insure adequate clearance from other traffic and obstructions and provide the most direct routing for efficient operations. As part of a larger program to develop the necessary technology base, a flight investigation was undertaken to study the problems associated with manual and automatic control of steep, decelerating instrument approaches and landings. The study employed a three-cue flight director driven by control laws developed and refined during manual-control studies and subsequently applied to the automatic approach problem. The validity of this approach was demonstrated by performing the first automatic approach and landings to a predetermined spot ever accomplished with a helicopter. The manual-control studies resulted in the development of a constant-attitude deceleration profile and a low-noise navigation system.

Kelly, J. R.↗