Adaptive Optical Two-Photon Fluorescence Microscopy Probes Cellular Organization of Ocular Lenses In Vivo

The mammalian ocular lens is an avascular multicellular organ that grows continuously throughout life. Traditionally, its cellular organization is investigated using dissected lenses, which eliminates in vivo environmental and structural support. Therefore, in vivo optical imaging methods for studying lenses in their native context in live animals are urgently needed. Here, we demonstrated that two-photon fluorescence microscopy can visualize lens cells in vivo. To maintain subcellular resolution at depth, we used adaptive optics to correct aberrations owing to ocular and lens tissues, which led to substantial signal and resolution improvements. Imaging lens cells up to 980 µm deep, we observed novel cellular organizations including suture-associated voids, enlarged vacuoles, and large cavities, contrary to the conventional view of a highly ordered organization. We tracked these features longitudinally over weeks and observed the incorporation of new cells during growth. Taken together, noninvasive longitudinal in vivo imaging of lens morphology using adaptive optics two-photon fluorescence microscopy will allow us to observe the development or alterations of lens cellular organization in living animals directly.

60 APPLIED LIFE SCIENCES↗

Highly Catalytically Active High-spin Single-atom Iron Catalyst Supported by Catechol-containing Microporous 2D Polymer

Traditionally, Fe-SACs are prepared through energy-intense processes, which often lead to the loss of precision in structural features from the starting substrates and impeding rational design. In this work, we have described the synthesis of a unique catechol-containing porous polymer with designed features in the substrates maintained, affording atomically dispersed iron catalyst (Fe-SAC) through treatment of ferrous chloride (FeCl 2 ). An aberration-corrected scanning transmission electron microscope (AC-STEM) and synchrotron X-ray absorption spectroscopy (XAS) were employed to shed light on the local coordination geometry of the atomically dispersed iron catalyst. The resulting Fe-SAC exhibits excellent catalytic performance in reduction of nitroaromatics with highest molar K app among all Fe based catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dataset for "Resistance of Boron Nitride Nanotubes to Radiation-Induced Oxidation" as published in The Journal of Physical Chemistry C

We present unprecedented results on the damage thresholds and pathways for boron nitride nanotubes (BNNT) under the influence of energetic electrons in an oxidative gas environment, using an environmental aberration-corrected electron microscope over a range of oxygen pressures. We observe a damage cascade process that resists damage until a higher electron dose, compared with carbon nanotubes, initiating at defect-free BNNT sidewalls and proceeding through the conversion from crystalline nanotubes to amorphous boron nitride (BN), resisting oxidation throughout. We compare with prior results on the oxidation of carbon nanotubes and present a model that attributes the onset of damage in both cases to a physisorbed oxygen layer that reduces the threshold for damage onset. Surprisingly, increased temperatures offer protection against damage, as do electron dose rates that significantly exceed the oxygen dose rates, and our model attributes both effects to a physisorbed oxygen population.

Adsorption↗

High spatial and energy resolution electron energy loss spectroscopy of the magnetic and electric excitations in plasmonic nanorod oligomers

We leverage the high spatial and energy resolution of monochromated aberration-corrected scanning transmission electron microscopy to study the hybridization of cyclic assemblies of plasmonic gold nanorods. Detailed experiments and simulations elucidate the hybridization of the coupled long-axis dipole modes into collective magnetic and electric dipole plasmon resonances. We resolve the magnetic dipole mode in these closed loop oligomers with electron energy loss spectroscopy and confirm the mode assignment with its characteristic spectrum image. The energy splitting of the magnetic mode and antibonding modes increases with the number of polygon edges (n). For the n=3-6 oligomers studied, optical simulations using normal incidence and s-polarized oblique incidence show the respective electric and magnetic modes’ extinction efficiencies are maximized in the n=4 arrangement.

47 OTHER INSTRUMENTATION↗

Electron Energy-Loss Spectroscopy and Differential Phase Contrast Imaging with Active Decision in Multimodal Electron Microscopy: Isotopic detection at the atomic scale

Isotopic engineering provides a powerful route to control phonon behavior in crystalline solids, enabling fundamental studies of lattice dynamics and heat transport at the atomic scale. Here, we directly visualize isotope-dependent phonon propagation in epitaxial Cr 2 O 3 using aberration-corrected scanning transmission electron microscopy (STEM) combined with monochromated, high-energy-resolution electron energy-loss spectroscopy (EELS). Guided by ab initio phonon calculations, we demonstrate that optical phonon modes above 70 meV are predominantly oxygen-derived and exhibit measurable redshifts upon substitution of natural 16 O by enriched 18 O. Spatially resolved vibrational spectrum imaging reveals isotope-enriched tracer layers within Cr 2 O 3 thin films, correlating isotope concentration with phonon intensity variations and vibrational energy shifts. At the nanometer and atomic scales, vibrational EELS mapping uncovers coherent phonon propagation across isotopic interfaces, consistent with theoretical phonon density of states and dispersion relations. These results establish vibrational EELS as a quantitative probe for isotope-dependent phonon transport in materials, opening new possibilities for studying energy dissipation and lattice dynamics.

36 MATERIALS SCIENCE↗

The Art of Automation: Translating Electron Microscopy Workflows Into Automated Processes

Acquiring data using a scanning transmission electron microscope (STEM) is a complex, multi-step process. The intricacy of the process depends on the type of sample, composition of the material, desired results of the experiment, resolution requirement and other experimental factors. Each experiment presents unique complications, such as sample drift and contamination, that the microscopist must consider when acquiring data. All these challenges are handled fluidly and expertly by experienced microscopists, but to reach new levels of innovation in material development, including greater reproducibility, throughput, and precision, the automation of these workflows is essential. The initial phase of this work involved translating intuition-based workflows into discrete, programmable steps. Some common key stages in STEM workflows are the initial tuning, scanning the sample for areas of interest, and then acquiring the data. Each stage can be broken further into specific parameter adjustments, such as aberration correction and dwell time optimization, depending on the experiment. When deconstructing various experiments each step was assessed for automation feasibility based on the amount of real time operator decisions. There are steps that lend themselves to automation more readily than others, such as course focusing and sample screening, but there is potential for full automation of all stages with time. As an initial step, an automated montage routine was developed, allowing for the efficient acquisition of large portions of the sample without requiring continuous intervention from the operator. The automation of this small process of the procedure demonstrates the value of this capability. A major challenge in automation arises from discrepancies between commanded, reported and actual stage movements. Using systematic tests, stage movement was quantified. This error can be corrected algorithmically for more accurate workflows in the future. Expanding automation capabilities would result in larger, more efficient data acquisition which allows for more robust statistical analysis. Additionally, this work lays the groundwork for a closed loop system where machine learning algorithms would intake automatically acquired data and make real time decisions. By progressively automating this instrument, this work establishes the foundation for fully automated experimentation in transmission electron microscopy.

97 MATHEMATICS AND COMPUTING↗

Manufacturing of Complex Silicon–Carbon Structures: Exploring Si x C y Materials

This paper reports on the manufacturing of complex three-dimensional Si/C structures via a chemical vapor deposition method. The structure and properties of the grown materials were characterized using various techniques including scanning electron microscopy, aberration-corrected transmission electron microscopy, confocal Raman spectroscopy, and X-ray photoelectron spectroscopy. The spectroscopy results revealed that the grown materials were composed of micro/nanostructures with various compositions and dimensions. These included two-dimensional silicon carbide (SiC), cubic silicon, and various SiC polytypes. The coexistence of these phases at the nano-level and their interfaces can benefit several Si/C-based applications ranging from ceramics and structural applications to power electronics, aerospace, and high-temperature applications. With an average density of 7 mg/cm 3 , the grown materials can be considered ultralightweight, as they are three orders of magnitude lighter than bulk Si/C materials. This study aims to impact how ceramic materials are manufactured, which may lead to the design of new carbide materials or Si/C-based lightweight structures with additional functionalities and desired properties.

36 MATERIALS SCIENCE↗

Ethanol Electrooxidation at 1–2 nm AuPd Nanoparticles

We report a systematic study of the electrocatalytic properties and stability of a series of 1–2 nm Au, Pd, and AuPd alloy nanoparticles (NPs) for the ethanol oxidation reaction (EOR). Following EOR electrocatalysis, NP sizes and compositions were characterized using aberration-corrected scanning transmission electron microscopy (ac-STEM) and energy dispersive spectroscopy (EDS). Two main findings emerge from this study. First, alloyed AuPd NPs exhibit enhanced electrocatalytic EOR activity compared to either monometallic Au or Pd NPs. Specifically, NPs having a 3:1 ratio of Au:Pd exhibit an ~8-fold increase in peak current density compared to Pd NPs, with an onset potential shifted ~200 mV more to the negative compared to Au NPs. Second, the size and composition of AuPd alloy NPs do not (within experimental error) change following 1.0 or 2.0 h chronoamperometry experiments, while monometallic Au NPs increase in size from 2 to 5 nm under the same conditions. Notably, this report demonstrates the importance of post-catalytic ac-STEM/EDS characterization for fully evaluating NP activity and stability, especially for 1–2 nm NPs that may change in size or structure during electrocatalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing the Boundary between Classical and Quantum Mechanics by Analyzing the Energy Dependence of Single-Electron Scattering Events at the Nanoscale

The relation between the energy-dependent particle and wave descriptions of electron–matter interactions on the nanoscale was analyzed by measuring the delocalization of an evanescent field from energy-filtered amplitude images of sample/vacuum interfaces with a special aberration-corrected electron microscope. The spatial field extension coincided with the energy-dependent self-coherence length of propagating wave packets that obeyed the time-dependent Schrödinger equation, and underwent a Goos–Hänchen shift. The findings support the view that wave packets are created by self-interferences during coherent–inelastic Coulomb interactions with a decoherence phase close to Δφ = 0.5 rad. Due to a strictly reciprocal dependence on energy, the wave packets shrink below atomic dimensions for electron energy losses beyond 1000 eV, and thus appear particle-like. Consequently, our observations inevitably include pulse-like wave propagations that stimulate structural dynamics in nanomaterials at any electron energy loss, which can be exploited to unravel time-dependent structure–function relationships on the nanoscale.

36 MATERIALS SCIENCE↗

Picometer-Precision Atomic Position Tracking through Electron Microscopy

The modern aberration-corrected scanning electron microscopes have successfully achieved direct visualization of atomic columns with sub-angstrom resolution. With this significant progress, advanced image quantification and analysis is still at its early stages. In this work, we present the complete pathway for the metrology of atomic resolution STEM images. This includes: 1) tips for acquiring high-quality STEM images; 2) denoising and drift-correction for enhancing measurement accuracy; 3) obtaining initial atom positions; 4) indexing the atoms based on unit cell vectors; 4) quantifying the atom column positions with either 2D-gaussian single peak fitting or 5) multi-peak fitting routines for slightly overlapping atomic columns; 6) quantification of lattice distortion/strain within the crystal structures or at the defects/interfaces where the lattice periodicity is disrupted, and 7) some common methods to visualize and present the analysis. Furthermore, a simple self-developed free MATLAB app (EASY-STEM) with a graphical user interface (GUI) will be introduced that can help with the analysis of STEM images without the need for writing dedicated analysis code or software. The advanced data analysis methods presented here can be applied for the local quantification of defect relaxations, local structural distortions, local phase transformations, and non-centrosymmetry in a wide range of materials.

47 OTHER INSTRUMENTATION↗

Performing In Situ Closed-Cell Gas Reactions in the Transmission Electron Microscope

Gas reactions studied by in situ electron microscopy can be used to capture the real-time morphological and microchemical transformations of materials at length scales down to the atomic level. In situ closed-cell gas reaction (CCGR) studies performed using (scanning) transmission electron microscopy (STEM) can separate and identify localized dynamic reactions, which are extremely challenging to capture using other characterization techniques. For these experiments, we used a CCGR holder that utilizes microelectromechanical systems (MEMS)-based heating microchips (hereafter referred to as "E-chips"). The experimental protocol described here details the method for performing in situ gas reactions in dry and wet gases in an aberration-corrected STEM. This method finds relevance in many different materials systems, such as catalysis and high-temperature oxidation of structural materials at atmospheric pressure and in the presence of various gases with or without water vapor. Here, several sample preparation methods are described for various material form factors. During the reaction, mass spectra obtained with a residual gas analyzer (RGA) system with and without water vapor further validates gas exposure conditions during reactions. Integrating an RGA with an in situ CCGR-STEM system can, therefore, provide critical insight to correlate gas composition with the dynamic surface evolution of materials during reactions. In situ/operando studies using this approach allow for detailed investigation of the fundamental reaction mechanisms and kinetics that occur at specific environmental conditions (time, temperature, gas, pressure), in real-time, and at high spatial resolution.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Study of shuttle imaging microwave system antenna. Volume 1: Conceptual design

A detailed preliminary design and complete performance evaluation are presented of an 11-channel large aperture scanning radiometer antenna for the shuttle imaging microwave system (SIMS) program. Provisions for interfacing the antenna with the space shuttle orbiter are presented and discussed. A program plan for hardware development and a rough order of magnitude (ROM) cost are also included. The conceptual design of the antenna is presented. It consists of a four-meter diameter parabolic torus main reflector, which is a graphite/epoxy shell supported by a graphite/epoxy truss. A rotating feed wheel assembly supports six Gregorian subreflectors covering the upper eight frequency channels from 6.6 GHz through 118.7 GHz, and two three-channel prime forms feed assemblies for 0.6, 1.4, and 2.7 GHz. The feed wheel assembly also holds the radiometers and power supplies, and a drive system using a 400 Hz synchronous motor is described. The RF analysis of the antenna is performed using physical optics procedures for both the dual reflector Gregorian concept and the single reflector prime focus concept. A unique aberration correcting feed for 2.7 GHz is analyzed. A structural analysis is also included. The analyses indicate that the antenna will meet system requirements.

Wesley, R. W.↗

Design of an offset fed scanning antenna for the shuttle imaging microwave system

A design study is described for a mechanically scanned offset fed parabolic torus reflector antenna having a 4m x 2m aperture for simultaneous use at eleven frequency channels from UHF to millimeter wavelengths. A design for the antenna is presented utilizing dipole and horn feeds at the low frequencies and a Gregorian aberration correcting subreflector system for feeding the torus at the high frequencies. The results and details of a theroetical study based on geometrical optics performed to evaluate the high frequency design and the results of an experimental study involving a one-tenth scale model for evaluation of the low-frequency behavior are given. Beam efficiencies, antenna patterns, beamwidths and cross polarization levels are presented and these results demonstrate that the antenna concept is viable for the Shuttle Imaging Microwave System requirement.

Gustincic, J. J.↗

Mariner-Venus-Mercury optical navigation demonstration - Results and implications for future missions

Optical navigation uses spacecraft television pictures of a target body against a known star background in a process which relates the spacecraft trajectory to the target body. This technology was used in the Mariner-Venus-Mercury mission, with the optical data processed in near-real-time, simulating a mission critical environment. Optical data error sources were identified, and a star location error analysis was carried out. Several methods for selecting limb crossing coordinates were used, and a limb smear compensation was introduced. Omission of planetary aberration corrections was the source of large optical residuals.

Acton, C. H., Jr.↗

A high resolution holographic particle sizing system

This paper will review briefly the requirements of holography with respect to particle sizing techniques. A holographic construction system and the appropriate reconstruction system will be discussed regarding their characteristics and performance (i.e. system resolution, magnification, system aberration and correction of aberrations, and maximum total test volume). The capabilities of a commercial particle sizing system used to obtain particle sizes and distribution information from reconstructed holograms will be described and characterized. It will be shown that by using the methods described, high resolution throughout large test volumes can be achieved.

Witherow, W. K.↗

Space Telescope fine guidance - A design for manufacturability

The NASA Space Telescope (ST) is a 2.4-m aperture, f/24 Ritchey-Chretien telescope coupled to five on-board astronomical scientific packages. The very accurate line-of-sight stability required by ST during operating periods of up to 24 hours is maintained by the Pointing Control System whose optical system, the Fine Guidance Subsystem (FGS), is described. The Pointing Control System includes three identical FGSs, any two of which provide line-of-sight stabilization by tracking guide stars while the third performs astrometry. The optical system for the ST FGS performs the field aberration correction within the FGS near a pupil plane measuring only 52.7 mm. The design is simple and easily corrected, and offers substantial advantages over the traditional approach in terms of manufacturability.

Friedman, I.↗

Design concept for an IR mapping spectrometer for the Pluto fast flyby mission

The design of an IR mapping spectrometer that exceeds all the criteria of the Pluto Fast Flyby Mission will be presented. The instrument has a mass of approximately 1700 g and uses less than 4 W of power. The design concept is based on an f/3 spectrograph using an aberration-corrected concave holographic grating. Up to four spectral regions can be covered simultaneously by dividing the grating into two to four sections, each imaging the entrance slit on a different area of the array. The spectrography will be fed by a lightweight 5 in. f/3 telescope based on SDIO precepts. In order to provide spectroscopic access to the fundamental molecule frequencies, an extended-range NICMOS array to approximately 3.5 microns and an InSb array going to 5.8 microns will be considered.

Fink, U.↗

Reflective correctors for the Hubble Space Telescope axial instruments

Reflective correctors to compensate the spherical aberration in the Hubble Space Telescope are placed in front of three of the axial scientific instruments (a camera and two spectrographs) during the first scheduled refurbishment mission. The five correctors required are deployed from a new module that replaces the fourth axial instrument. Each corrector consists of a field mirror and an aspherical, aberration-correcting reimaging mirror. In the camera the angular resolution capability is restored, be it in reduced fields, and in the spectrographs the potential for observations in crowded areas is regained along with effective light collection at the slits.

Bottema, Murk↗