Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARGONNE LABORATORY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Adapting LEU-Modified Cintichem Process for Processing Up to 750 Grams of Uranium Targets

Argonne National Laboratory (Argonne) developed a low-enriched uranium (LEU)-modified Cintichem (LMC) process to enable production and purification of fission-produced molybdenum-99 (Mo-99) from LEU foil targets. This separation scheme starts with nitric acid (HNO 3 ) dissolution of irradiated LEU foil targets that yields an approximate final volume of 2 L. The dissolved uranium solution containing fission products, including Mo-99, is then treated by loading the solution on a titania-based recovery column to separate Mo-99 from bulk uranium. After several washing steps, Mo and other fission products are stripped from the titania column using sodium hydroxide (NaOH). The eluate is then acidified using nitric acid and subsequently processed for final purification using the LMC process. Uranium and most fission products are not adsorbed on the titania column but are eluted (i.e., removed using a solvent) during the wash steps; they can be purified and recycled into new uranium targets.

07 ISOTOPE AND RADIATION SOURCES↗

Financial Analysis of the 2022 Macroinvertebrate Production Flow Experiment at Glen Canyon Dam

This report was prepared by Argonne National Laboratory (Argonne) in support of a financial analysis of the Glen Canyon Dam (GCD) flow experiment that was intended to support downstream macroinvertebrate production that are a primary food supply for fishes in the Colorado River. Also known as “bug flow” experiments, these experimental water releases were conducted on the weekends and holidays from the beginnings of May 2022 through the end of August 2022. This analysis was funded by and prepared for the Colorado River Storage Project (CRSP) Office of the U.S. Department of Energy’s Western Area Power Administration (WAPA). CRSP markets electricity produced by hydroelectric facilities collectively known as the Salt Lake City Area Integrated Projects including dams equipped for power generation on the Colorado, Green, Gunnison, and Rio Grande Rivers and on Plateau Creek in the states of Arizona, Colorado, New Mexico, Utah, and Wyoming. Staff members in Argonne’s Energy Systems and Infrastructure Analysis Division prepared this technical memorandum with assistance from WAPA’s CRSP and Energy Marketing and Management Offices (EMMO).

13 HYDRO ENERGY↗

Community Resilience Indicator Analysis: Commonly Used Indicators from Peer-Reviewed Research (Updated for Research Published 2003-2021)

In 2017, FEMA’s National Integration Center (NIC) Technical Assistance (TA) Branch identified a need to establish a data-driven basis for prioritizing locations for TA investment and guiding local emergency management planning. To achieve this goal, FEMA tasked Argonne National Laboratory (Argonne) with identifying commonly used indicators of community resilience across the landscape of published peer-reviewed research. FEMA and Argonne completed the first Community Resilience Indicator Analysis (CRIA) in 2018 and repeated the process in 2022. The CRIA process begins with a literature review and cataloguing of published peer-reviewed assessment methodologies on social vulnerability and community resilience. The literature review findings are then filtered by inclusion criteria established by the CRIA research team to ensure the methodologies are: (1) Quantitative, (2) Data and methodology are publicly available, (3) Calculated at the county level or lower, (4) Examine generalized hazard risk (rather than a singular hazard), and (5) Focused on pre-disaster community conditions. After this, the research team identifies the commonly used indicators across these methodologies and selects the best data source for each indicator. Finally, the research team bins the data for visual display, conducts a correlation analysis and creates a composite index, the FEMA Community Resilience Index (FEMA CRI). In 2018, the CRIA identified eight resilience and vulnerability assessment methodologies and 20 commonly used indicators (indicators used in three or more of the eight methodologies). The FEMA CRI in 2018 was created from these 20 indicators and was produced for at the county level. The 2022 CRIA updated the literature review to expand the list of methodologies examined and followed the same process, resulting in an analysis of 14 methodologies published between 2003 and 2021 and 22 indicators identified as commonly used (indicators used in five or more of the 14 methodologies). In 2022, the research team produced the FEMA CRI at the county and the census tract levels. To make the CRIA data more accessible and more actionable, each individual indicator and the FEMA CRI is binned and included in FEMA’s Resilience Analysis and Planning Tool (RAPT). RAPT enables emergency managers and community partners to quickly visualize relative differences in potential resilience by county, tribe and census tract. By reviewing the data for each of these 22 indicators individually, emergency managers can gain insights for targeted outreach strategies, planning, mitigation investments and response and recovery operations. Communities, regional governments and others can use this data to better understand potential challenges to resilience. As the social science field of examining and validating indicators of resilience evolves, FEMA will update RAPT to provide emergency managers and community partners with additional data and tools to inform planning, mitigation, response and recovery. It is important to understand that the role of the emergency manager is not to change or to “improve” the data, but to plan appropriately for the community characteristics reflected in the data. These datasets are community characteristics that researchers have identified as important considerations for resilience. For example, people with disabilities may have greater challenges to be resilient to disasters. If a community has a high population of people with disabilities, the emergency manager(s) may need to create tailored preparedness outreach programs and strategies to ensure those residents have support if evacuation is necessary. Rather than label these indicators as an absolute measure of resilience, FEMA considers “potential challenges to resilience” a better frame to understand these indicators. Everyone is vulnerable to disasters. While scholars theorize that certain characteristics may make an individual or a household more socially vulnerable, the data does not reflect measures that individuals and/or communities have taken to address potential challenges, such as emergency management planning and outreach or household preparedness measures. To aid emergency managers in understanding how to use these indicators, calling them potential challenges to resilience supports a more positive and strategic application of the data in all phases of emergency management.

99 GENERAL AND MISCELLANEOUS↗

Semi-Annual Report for Horizontal Compact High Temperature Gas Reactor (HC-HTGR) Development during Performance Period October 2022-March 2023

Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed HC-HTGR in 3 years and support its commercialization as a safe, low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. Additionally, Argonne is providing analysis of the primary heat transport system to ensure temperatures in the reactor systems, structures and components with significant safety margins during normal operation and design basis accident scenarios. This third semi-annual report summarized the progress made at Argonne on the two tasks during the first half of FY23. As a part of the RCCS design task, a design process for the water panel and the system configuration was performed to improve the thermal performance of the RCCS. The updated water panel design had achieved enhanced thermal performance with 0.96 MWth capability with major design updates made in structural interfaces with the RPV and initial configuration of the water tanks. The loop configuration of the RCCS has been proposed to have two independently working loops for system redundancy. A water panel material study was performed focusing on the use of carbon steel in water systems. Additional modeling strategies of primary system thermal fluids analyses were developed to meet modeling needs that are not well suited for the 1D-3D assembly level approach. The first of these is a reduced order assembly model, in which fuel centered unit cells are used to represent a fuel assembly. The 2D approach used in this model is much more computationally efficient, making this model useful for full core transient scenarios where fuel to coolant heat transfer is still the dominant flow path. The next model is the 3D core conduction model to be used to analyze decay heat removal in loss of primary system flow scenarios. Because these scenarios require a large domain to be modeled, a homogenized core model is being pursued to reduce the required computational costs. To accurately model decay heat scenarios it is necessary to couple a RCCS model to the 3D core conduction model. A simplified case is presented to demonstrate how the coupling methodology will be applied to the full core 3D conduction model.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Predicting Switchgrass Biomass Yields Using a Spectral Vegetation Index Derived from Multispectral Satellite Imagery

Successful scaling of perennial bioenergy crop production requires a landscape design that optimizes the benefits of finite lands for people, communities, and environments. Utilizing marginal areas is the key to sustainable bioenergy crop production (Ssegane et al., 2015, 2016). Marginal areas are often small-sized lands and unevenly distributed across the agricultural landscape (Ssegane et al., 2016); thus, a systematic, semi-automated remote sensing method is needed as an effective means of estimating bioenergy crop yields across landscapes. Argonne National Laboratory (Argonne) is currently developing a tool, Scaling Up Perennial Bioenergy Economics and Ecosystem Services Tool (SUPERBEEST), to identify marginal agricultural lands and quantify environmental and economic effects of perennial bioenergy crop production systems. The tool aims to provide users a path to foster the sustainable and productive integration of bioenergy crops in the Midwestern agricultural landscape. Reliable, cost-effective, and timely estimation of bioenergy crop yields using remote sensing would help calculate and track the success of integrated bioenergy crops in the landscape for those communities. Argonne previously conducted feasibility studies for estimating biomass yields for bioenergy feedstock, corn and perennial grass using spectral vegetation indices (SVIs)1 derived from optical imagery (Hamada et al., 2015, 2021). In both studies, SVIs, more specifically those sensitive to plant chlorophyll or nitrogen contents, showed potential for estimating or predicting biomass yields with a correlation of determination (R2) ranging from 0.54 to 0.96, indicating a value for further investigation as a viable means of quantifying bioenergy feedstock production across large landscapes. Thus, the goal of this study is to evaluate the feasibility of use of SVIs as a means of estimating or predicting switchgrass biomass yields at harvest using publicly available multispectral satellite imagery. The feasibility analysis was performed using four study areas of mature switchgrass located in Virginia. Objectives are to (1) examine the SVIs and establish their relationships with switchgrass biomass yields at harvest, (2) develop a parsimonious image processing model for predicting at-harvest yields by applying the relationships with the most promising spectral index and (3) map switchgrass yields predicted by the image processing model across the study sites. The calibration to field data will rely on switchgrass biomass yields determined by the baling method, representing a potential challenge to the analysis but an important practical aspect for future applications. With this research design, the study aimed to gain insights into enabling remote sensing-based estimation of bioenergy crop yields in a reliable, cost- effective, and timely manner across large, heterogeneous landscapes.

09 BIOMASS FUELS↗

FY23 Progress on Computational Modeling of the Water-Based NSTF

This report summarizes the system-level modeling effort by Argonne National Laboratory (Argonne) of the Natural convection Shutdown heat removal Test Facility (NSTF) in FY23. As a continuation of the modeling effort from FY22, this year’s work focuses on improving the RELAP5-3D model developed previously for two-phase flow simulations. The RELAP5-3D model is updated to more accurately capture the heat loss experienced by the facility. The updated model is compared against experimental data for benchmarking purposes of the RELAP5-3D input model. By correctly accounting for heat loss, the updated RELAP5-3D model can now predict the two-phase baseline case more accurately. The onset and the duration of instability are captured well by the model. Furthermore, analyses are performed to better understand the instability mechanism experienced by the flow where the expansion of the boiling boundary in the chimney is studied in details and the fundamental frequencies of the oscillations are obtained. The updated RELAP5-3D model is further compared against four fault conditions, namely the reduction of riser header inlet flow area, depletion of system inventory, blocked riser channels, and static boiling scenario. For each fault condition, minor modifications and tuning are performed to improve the predictions of the model. The purpose of the analyses is to investigate the capability of RELAP5-3D in predicting complex two-phase flows in possible accident scenarios in actual Reactor Cavity Cooling System (RCCS). Overall, the model is able to capture the behaviors and trends of these fault conditions relatively well. Some discrepancies remain between the experimental data and the predictions, many of which are likely due to the differences in the predicted and experimental vapor generation rate. Future work will focus on the continued development of the current RELAP5-3D input model of the NSTF to both improve the accuracy of the model’s predictive capability and continue supporting the experimental program needs. The mutually beneficial relationship between analysis and experimental efforts has become integral to the parent NSTF program, and the greater objective to fully understand and accurately predict the heat removal performance of a full scale RCCS concept.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Semi-Annual Report for Horizontal Compact High Temperature Gas Reactor (HC-HTGR) Development during Performance Period April 2023 – September 2023

Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed HC-HTGR in 3 years and support its commercialization as a safe, low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. Additionally, Argonne is providing analysis of the primary coolant system to ensure temperatures within the core remain below safety margins during steady-state and potential accident scenarios. This fourth semi-annual report summarized the progress made at Argonne on the two tasks during the second half of FY23. As a part of the RCCS design task, recent efforts have been made to complete a conceptual design of the RCCS for the HC-HTGR, including the design update of the water panel and system configuration favorable in point of view of fabrication and system operation. Design calculations were conducted under various heat load conditions to validate the system design. Transient simulations using RELAP5-3D were conducted to investigate system dynamics under transients of interest and to evaluate the system performance in the design condition. The results demonstrated the overall system feasibility that the RCCS design maintains structures temperatures lower than maximum allowable temperature with sufficient system inventory without any active heat sink. In the primary system thermal hydraulics task, the preliminary analysis was performed for a long term pressurized conduction cooldown (PCC) transient. This analysis used a combination of a fully resolved and coarse homogenized mesh to predict the temperature distribution for the steady-state initial condition and the PCC transient. The steady-state initial condition was determined using a fully resolved full core model with 3D solid to 1D fluid coupling. The fully resolved mesh was also used to model the first 20 seconds of the PCC. The temperature difference between fuel pins and the graphite matrix becomes minimal and the dominant heat transfer shifts to a larger scale radially towards the RCCS. After 20 seconds, a homogenized coarse mesh is used, greatly reducing the computational costs of the model. These results demonstrate that the core is designed to passively remove enough decay heat in a protected loss of primary coolant flow to prevent an unsafe rise of core temperatures.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Summary of Expansions and Updates in R&D GREET ® 2023

The Greenhouse gases, Regulated Emissions, and Energy use in Technologies (GREET®) model was developed by Argonne National Laboratory (Argonne) with the support of the U.S. Department of Energy (DOE) and other federal agencies. R&D GREET is a life cycle analysis (LCA) model, structured to systematically examine the energy and environmental effects of a wide variety of transportation fuels and vehicle technologies in major transportation sectors (i.e., road, air, marine, and rail), other end-use sectors, and energy systems. Argonne has expanded and updated the model in various areas in R&D GREET 2023. This report provides a summary of the expansions and updates.

33 ADVANCED PROPULSION SYSTEMS↗

Rosario Strait Tidal Energy plus Energy Storage — Preliminary Economic Assessment

The Orcas Power and Light Co-op (OPALCO) is a non-profit utility that provides energy services to approximately 11,700 customers across 20 islands in San Juan County, Washington. OPALCO is developing a diverse set of local renewable energy resources to reduce dependence on mainland Washington State for energy and to reduce the regional need for fossil-fueled power. OPALCO’s load doubles in winter but solar production is roughly 20% of levels reached in summer periods. Tidal energy is strong year-round, night and day, and is predictable, requiring much less storage to firm it. To assess the technical and economic feasibility of tidal power, working in combination with multiple other distributed energy resources (DERs), Argonne National Laboratory (Argonne) employed an optimization model to evaluate several economic benefits associated with varying scales of tidal power of between 2.4 and 9.6 megawatts (MW) and other DERs. In addition to existing photovoltaic (PV) and battery energy storage system (BESS) resources located on Decatur Island, Argonne also evaluated the addition of a BESS on southern Orcas Island with power and energy capacities ranging from 1-4 MW and 2-4 hours in storage duration.

25 ENERGY STORAGE↗

SAM Assessment Report

The System Analysis Module (SAM) is a modern system analysis tool being developed at Argonne National Laboratory (Argonne) for advanced non-LWR safety analysis. A series of assessment cases are modeled using SAM and, when applicable, compared against analytical solutions or engineering judgement. This report documents the assessment of SAM for eleven different categories. Each category contains a series of tests that examine different boundary conditions, system configurations, or modeling options. Although relatively simple, these tests cover the basic equation models, basic component models, and basic system level processes and phenomena that may be utilized during advanced reactor safety analyses.

1-D fluid flow↗

A Conceptual Design of the Reactor Cavity Cooling System for the Horizontal Compact High Temperature Gas Reactor (HC-HTGR)

Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed HC-HTGR in 3 years and support its commercialization as a safe, low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. This report documents the design study to derive a conceptual design study of the RCCS for the HC-HTGR. It includes the identification of the functions and requirements of the HC-HTGR RCCS, design analyses including high-level design consideration and the calculations for optimizing design space of the system with supporting component-level analysis to inform the material selection and performance of the water panel, the description of the conceptual design of the HC-HTGR RCCS derived based on the analyses results, and performance evaluation of the conceptual RCCS for the HC-HTGR. A detailed concept of the RCCS has been identified and high-level system requirements has been developed for the HC-HTGR. Design space focusing on the natural circulation loop portion of the RCCS has been investigated to optimize the system performance. The initial baseline dimensions were firstly derived based on the scoping calculations. A component level design analysis was conducted for the water panel to inform the material selection and to assess its conduction performance. A preliminary system-level performance analysis was performed for the 1/8th of the compartment of the initial baseline design of the RCCS using RELAP5-3D. To improve the system thermal performance, the RCCS design has been updated by exploring various design options by design parametric analyses. Based on the results, the conceptual design of the RCCS for the HC-HTGR has been derived, which satisfies the target performance of ~1 MWt at the elevated vessel wall temperature conditions. Transient simulations were conducted for the conceptual RCCS design for the HC-HTGR under various operation modes and heat load conditions using RELAP5-3D. The system dynamics in different operating states was investigated and the system performance under transients of interest was evaluated. The results demonstrated the overall system feasibility that the RCCS design maintains structures temperatures lower than maximum allowable temperature with sufficient system inventory without any active heat removal in the design process with certain transients addressed. The HC-HTGR RCCS will have additional design updates of subsystems or optimization of the system components during the preliminary and final design phases. Since the entire plant has not been integrated yet, this delivered conceptual design is subject to changes for integration, that require additional conceptual design activities and Quality and Assurance implementation (Q&A). The performance assessment of the RCCS for the HC-HTGR will be then revisited and optimized to finalize the system design, and the RCCS integrated primary system analysis will be utilized to simulate selective accident scenarios of interest where efforts are currently undergoing in the project.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Site A and Plot M 2023 Surveillance Report and 2024 Inspection Report

This report is prepared for the U. S. Department of Energy (DOE) Office of Legacy Management (DOE-LM) by the Worker Safety & Environment (WSE) Division at Argonne National Laboratory (Argonne). Beginning in 2024, Argonne drafted a combined report containing the annual inspection results for the current year and the annual surveillance data/discussion from the previous year. The annual inspection results will be contained within an appendix at the end of the surveillance report. The results of the environmental monitoring program at Site A and Plot M and an assessment of the impact of the site on the environment and the public are presented in this publication as well as findings and assigned corrective actions as a result of the Site A/Plot M annual inspection. Funding to support this program was provided by DOE-LM.

54 ENVIRONMENTAL SCIENCES↗

MDDC Multi-Length Scale Data Architecture Contribution Report – PNNL, INL, ANL, LANL and ORNL

This report offers a comprehensive view of data streams currently generated at Pacific Northwest National Laboratory, Idaho National Laboratory, Argonne National Laboratory, Los Alamos National Laboratory, and Oak Ridge National Laboratory set to integrate into the evolving Multi-Dimensional Data Correlation framework at Oak Ridge National Laboratory. Developed by the Advanced Materials and Manufacturing Technologies program, the Multi-Dimensional Data Correlation framework serves as a cutting-edge software to manage data relevant to advanced manufacturing and material behavior in advanced reactors. The report defines data streams, highlights their generation methods and visualization methods both for experimental and computational aspects relevant to the Advanced Materials and Manufacturing Technologies project. A logical next step for this work is to integrate the MDDC framework into PNNL’s, INL’s, ANL’s, LANL’s and ORNL’s fabrication, experimentation, and modelling workflows. This would require setting up the MDDC framework at PNNL, INL, ANL, and LANL and integrating it into the data collection and storage for these different activities.

36 MATERIALS SCIENCE↗

Final work plan : investigation of potential contamination at the former CCC/USDA grain storage facility in Hanover, Kansas.

The Commodity Credit Corporation (CCC), an agency of the U.S. Department of Agriculture (USDA), operated a grain storage facility at the northeastern edge of the city of Hanover, Kansas, from 1950 until the early 1970s. During this time, commercial grain fumigants containing carbon tetrachloride were in common use by the grain storage industry to preserve grain in their facilities. In February 1998, trace to low levels of carbon tetrachloride (below the maximum contaminant level [MCL] of 5.0 {micro}g/L) were detected in two private wells near the former grain storage facility at Hanover, as part of a statewide USDA private well sampling program that was implemented by the Kansas Department of Health and Environment (KDHE) near former CCC/USDA facilities. In April 2007, the CCC/USDA collected near-surface soil samples at 1.8-2 ft BGL (below ground level) at 61 locations across the former CCC/USDA facility. All soil samples were analyzed by the rigorous gas chromatograph-mass spectrometer analytical method (purge-and-trap method). No contamination was found in soil samples above the reporting limit of 10 {micro}g/kg. In July 2007, the CCC/USDA sampled indoor air at nine residences on or adjacent to its former facility to address the residents concerns regarding vapor intrusion. Low levels of carbon tetrachloride were detected at four of the nine homes. Because carbon tetrachloride found in private wells and indoor air at the site might be linked to historical use of fumigants containing carbon tetrachloride at its former grain storage facility, the CCC/USDA is proposing to conduct an investigation to determine the source and extent of the carbon tetrachloride contamination associated with the former facility. This investigation will be conducted in accordance with the intergovernmental agreement between the KDHE and the Farm Service Agency (FSA) of the USDA. The investigation at Hanover will be performed, on behalf of the CCC/USDA, by the Environmental Science Division of Argonne National Laboratory. Argonne is a nonprofit, multidisciplinary research center operated by UChicago Argonne, LLC, for the U.S. Department of Energy (DOE). The CCC/USDA has entered into an interagency agreement with DOE, under which Argonne provides technical assistance to the CCC/USDA with environmental site characterization and remediation at its former grain storage facilities. Seven technical objectives have been proposed for the Hanover investigation. They are as follows: (1) Identify the sources and extent of soil contamination beneath the former CCC/USDA facility; (2) Characterize groundwater contamination beneath the former CCC/USDA facility; (3) Determine groundwater flow patterns; (4) Define the vertical and lateral extent of the groundwater plume outside the former CCC/USDA facility; (5) Evaluate the aquifer and monitor the groundwater system; (6) Identify any other potential sources of contamination that are not related to activities of the CCC/USDA; and (7) Determine whether there is a vapor intrusion problem at the site attributable to the former CCC/USDA facility. The technical objectives will be accomplished in a phased approached. Data collected during each phase will be evaluated to determine whether the subsequent phase is necessary. The KDHE project manager and the CCC/USDA will be contacted during each phase and kept apprised of the results. Whether implementation of each phase of work is necessary will be discussed and mutually agreed upon by the CCC/USDA and KDHE project managers.

54 ENVIRONMENTAL SCIENCES↗

Contingency interim measure for the public water supply at Barnes, Kansas.

This document presents a conceptual design for a contingency interim measure (IM) for treatment of the public water supply system at Barnes, Kansas, should this become necessary. The aquifer that serves the public water supply system at Barnes has been affected by trace to low concentrations of carbon tetrachloride and its degradation product, chloroform. Investigations conducted on behalf of the CCC/USDA by Argonne National Laboratory (Argonne 2008a) have demonstrated that groundwater at the Barnes site is contaminated with carbon tetrachloride at concentrations exceeding the Kansas Tier 2 risk-based screening level (RBSL) and the EPA maximum contaminant level (MCL) of 5.0 {micro}g/L for this compound. The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) formerly operated a grain storage facility in Barnes, approximately 800 ft east-southeast of the public water supply wells. Carbon tetrachloride was used in the treatment of grain. Another potential source identified in an investigation conducted for the KDHE (PRC 1996) is the site of a former agriculture building owned by the local school district (USD 223). This building is located immediately east of well PWS3. The potential contingency IM options evaluated in this report include the treatment of groundwater at the public water supply wellheads and the provision of an alternate water supply via Washington County Rural Water District No.2 (RWD 2). This document was developed in accordance with KDHE Bureau of Environmental Remediation (BER) Policy No.BER-RS-029 (Revised) (KDHE 2006a), supplemented by guidance from the KDHE project manager. Upon the approval of this contingency IM conceptual design by the KDHE, the CCC/USDA will prepare a treatment system design document that will contain the following elements: (1) Description of the approved contingency IM treatment method; (2) Drawings and/or schematics provided by the contractor and/or manufacturer of the approved technology; (3) A detailed work schedule with a generic timetable; (4) A detailed operations and maintenance plan; (5) A proposed performance monitoring plan; and (6) A fact sheet associated with a community relations plan.

54 ENVIRONMENTAL SCIENCES↗

317/319 Phytoremediation site monitoring report - 2009 growing season : final report.

In 1999, Argonne National Laboratory (Argonne) designed and installed a series of engineered plantings consisting of a vegetative cover system and approximately 800 hybrid poplars and willows rooting at various predetermined depths. The plants were installed using various methods including Applied Natural Science's TreeWell{reg_sign} system. The goal of the installation was to protect downgradient surface and groundwater by intercepting the contaminated groundwater with the tree roots, removing moisture from the upgradient soil area, reducing water infiltration, preventing soil erosion, degrading and/or transpiring the residual volatile organic compounds (VOCs), and removing tritium from the subsoil and groundwater. This report presents the results of the monitoring activities conducted by Argonne's Energy Systems (ES) Division in the growing season of 2009. Monitoring of the planted trees began soon after the trees were installed in 1999 and has been conducted every summer since then. As the trees grew and consolidated their growth into the contaminated soil and groundwater, their exposure to the contaminants was progressively shown through tissue sampling. During the 2009 sampling campaign, VOC concentrations found in the French Drain area were in general consistent with or slightly lower than the 2008 results. Additionally, closely repeated, stand wide analyses showed contaminant fluctuations that may indicate short-term contaminant depletion in the area of interest of roots. This data will be useful to determine short-term removal rate by the trees. As in previous years, levels in the Hydraulic Control Area were close to background levels except for a few exceptions.

54 ENVIRONMENTAL SCIENCES↗

Final work plan : phase I investigation of potential contamination at the former CCC/USDA grain storage facility in Montgomery City, Missouri.

From September 1949 until September 1966, the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) leased property at the southeastern end of Montgomery City, Missouri, for the operation of a grain storage facility. During this time, commercial grain fumigants containing carbon tetrachloride were commonly used by the CCC/USDA and the private grain storage industry to preserve grain in their facilities. In January 2000, carbon tetrachloride was detected in a soil sample (220 {micro}g/kg) and two soil gas samples (58 {micro}g/m{sup 3} and 550 {micro}g/m{sup 3}) collected at the former CCC/USDA facility, as a result of a pre-CERCLIS site screening investigation (SSI) performed by TN & Associates, Inc., on behalf of the U.S. Environmental Protection Agency (EPA), Region VII (MoDNR 2001). In June 2001, the Missouri Department of Natural Resources (MoDNR) conducted further sampling of the soils and groundwater at the former CCC/USDA facility as part of a preliminary assessment/site inspection (PA/SI). The MoDNR confirmed the presence of carbon tetrachloride (at a maximum identified concentration of 2,810 {micro}g/kg) and chloroform (maximum 82 {micro}g/kg) in the soils and also detected carbon tetrachloride and chloroform (42.2 {micro}g/L and 58.4 {micro}g/L, respectively) in a groundwater sample collected at the former facility (MoDNR 2001). The carbon tetrachloride levels identified in the soils and groundwater are above the default target level (DTL) values established by the MoDNR for this contaminant in soils of all types (79.6 {micro}g/kg) and in groundwater (5.0 {micro}g/L), as outlined in Missouri Risk-Based Corrective Action (MRBCA): Departmental Technical Guidance (MoDNR 2006a). The corresponding MRBCA DTL values for chloroform are 76.6 {micro}g/kg in soils of all types and 80 {micro}g/L in groundwater. Because the observed contamination at Montgomery City might be linked to the past use of carbon tetrachloride-based fumigants at its former grain storage facility, the CCC/USDA will conduct investigations to (1) characterize the source(s), extent, and factors controlling the possible subsurface distribution and movement of carbon tetrachloride at the Montgomery City site and (2) evaluate the health and environmental threats potentially represented by the contamination. This work will be performed in accord with the Intergovernmental Agreement established between the Farm Service Agency of the USDA and the MoDNR, to address carbon tetrachloride contamination potentially associated with a number of former CCC/USDA grain storage facilities in Missouri. The investigations at Montgomery City will be conducted on behalf of the CCC/USDA by the Environmental Science Division of Argonne National Laboratory. Argonne is a nonprofit, multidisciplinary research center operated by UChicago Argonne, LLC, for the U.S. Department of Energy (DOE). The CCC/USDA has entered into an agreement with DOE, under which Argonne provides technical assistance to the CCC/USDA with environmental site characterization and remediation at its former grain storage facilities. The site characterization at Montgomery City will take place in phases. This approach is recommended by the CCC/USDA and Argonne, so that information obtained and interpretations developed during each incremental stage of the investigation can be used most effectively to guide subsequent phases of the program. This site-specific Work Plan outlines the specific technical objectives and scope of work proposed for Phase I of the Montgomery City investigation. This Work Plan also includes the community relations plan to be followed throughout the CCC/USDA program at the Montgomery City site. Argonne is developing a Master Work Plan specific to operations in the state of Missouri. In the meantime, Argonne has issued a Provisional Master Work Plan (PMWP; Argonne 2007) that has been reviewed and approved by the MoDNR for current use. The PMWP (Argonne 2007) provides detailed information and guidance on the investigative technologies, analytical methodologies, quality assurance-quality control measures, and general health and safety policies to be employed by Argonne for all investigations at former CCC/USDA grain storage facilities in Missouri. Both the PMWP and this site-specific Work Plan must therefore be consulted for a complete description of the planned Phase I work at the former CCC/USDA facility at Montgomery City.

54 ENVIRONMENTAL SCIENCES↗

Earth System Grid Center for Enabling Technologies: Building a Global Infrastructure for Climate Change Research

Established within DOE’s Scientific Discovery through Advanced Computing (SciDAC-) 2 program, with support from ASCR and BER, the Earth System Grid Center for Enabling Technologies (ESG-CET) is a consortium of seven laboratories (Argonne National Laboratory [ANL], Los Alamos National Laboratory [LANL], Lawrence Berkeley National Laboratory [LBNL], Lawrence Livermore National Laboratory [LLNL], National Center for Atmospheric Research [NCAR], Oak Ridge National Laboratory [ORNL], and Pacific Marine Environmental Laboratory [PMEL]), and two institutes (Rensselaer Polytechnic Institute [RPI] and the University of Southern California, Information Sciences Institute [USC/ISI]). The consortium’s mission is to provide climate researchers worldwide with a science gateway to access data, information, models, analysis tools, and computational capabilities required to evaluate extreme-scale data sets. Its stated goals are to (1) make data more useful to climate researchers by developing collaborative technology that enhances data usability; (2) meet the specific needs that national and international climate projects have for distributed databases, data access, and data movement; (3) provide a universal and secure web-based data access portal for broad-based multi-model data collections; and (4) provide a wide range of climate data-analysis tools and diagnostic methods to international climate centers and U.S. government agencies. To this end, the ESG-CET is working to integrate all highly publicized climate data sets—from climate simulations to observations—using distributed storage management, remote high-performance units, high-bandwidth wide-area networks, and user desktop platforms in a collaborative problem-solving environment.

54 ENVIRONMENTAL SCIENCES↗