Efficacy of FTIR Analysis in Determining CO2 Loading on Diglycolamine

In support of advanced air revitalization technologies to enable human spaceflight beyond low earth orbit, performance studies have been conducted using a liquid amine, Diglycolamine (DGA) between teams at NASA?s Johnson Spaceflight Center (JSC) and Ames Research Center (ARC). Liquid amines have been used in regenerable earth-based systems to remove CO2 from industrial systems as well as for closed-environment air revitalization because they can be regenerated at lower temperatures than solid sorbent systems. As an additional advantage to solid sorbent based systems, liquid sorbents can be cycled between an adsorbing contactor and degassing chamber, thereby reducing system complexity by operation in a continuous loop. In an effort to inform a regeneration system design for micro-gravity applications, ARC has performed a number of tests to characterize the degas mechanics of DGA. In order to accurately measure the amount of CO2 captured or released by the amine, methods such as gravimetric weighing and chemical decomposition are reasonable, however the initial design for a scaled down degas system required analysis on small sample sizes. In order to accomplish CO2 loading measurements with a sample size of approximately 500µL, Fourier-transform infrared spectroscopy (FTIR) was used. Calibration against acid decomposition showed relatively good correlation and test data showed reasonable adherence to expected trends, however more extensive testing should be conducted to fully validate the usage of FTIR to determine CO2 loading on DGA.

Diglycolamine↗

Efficacy of FTIR Analysis in Determining CO2 Loading on Diglycolamine

In support of advanced air revitalization technologies to enable human spaceflight beyond low earth orbit, performance studies have been conducted using a liquid amine, Diglycolamine (DGA) between teams at NASA's Johnson Spaceflight Center (JSC) and Ames Research Center (ARC). Liquid amines have been used in regenerable earth-based systems to remove CO2 from industrial systems as well as for closed-environment air revitalization because they can be regenerated at lower temperatures than solid sorbent systems. As an additional advantage to solid sorbent-based systems, liquid sorbents can be cycled between an adsorbing contactor and degassing chamber, thereby reducing system complexity by operation in a continuous loop. In an effort to inform a regeneration system design for micro-gravity applications, ARC has performed a number of tests to characterize the degas mechanics of DGA. In order to accurately measure the amount of CO2 captured or released by the amine, methods such as gravimetric weighing and chemical desorption are reasonable, however the first iteration test setup for a scaled down degas system required analysis on small sample sizes. Fourier-transform infrared spectroscopy (FTIR) analysis was experimentally evaluated to analyze CO2 concentration because it can produce measurements with sample sizes on the order of 100's of μL. Calibration against chemical desorption showed relatively good correlation and test data showed reasonable adherence to expected trends, however more extensive testing should be conducted to fully validate the usage of FTIR to determine CO2 loading on DGA.

Diglycolamine↗

SU-E-T-184: Clinical VMAT QA Practice Using LINAC Delivery Log Files

Purpose: To evaluate the accuracy of volumetric modulated arc therapy (VMAT) treatment delivery dose clouds by comparing linac log data to doses measured using an ionization chamber and film. Methods: A commercial IMRT quality assurance (QA) process utilizing a DICOM-RT framework was tested for clinical practice using 30 prostate and 30 head and neck VMAT plans. Delivered 3D VMAT dose distributions were independently checked using a PinPoint ionization chamber and radiographic film in a solid water phantom. DICOM RT coordinates were used to extract the corresponding point and planar doses from 3D log file dose distributions. Point doses were evaluated by computing the percent error between log file and chamber measured values. A planar dose evaluation was performed for each plan using a 2D gamma analysis with 3% global dose difference and 3 mm isodose point distance criteria. The same analysis was performed to compare treatment planning system (TPS) doses to measured values to establish a baseline assessment of agreement. Results: The mean percent error between log file and ionization chamber dose was 1.0%±2.1% for prostate VMAT plans and −0.2%±1.4% for head and neck plans. The corresponding TPS calculated and measured ionization chamber values agree within 1.7%±1.6%. The average 2D gamma passing rates for the log file comparison to film are 98.8%±1.0% and 96.2%±4.2% for the prostate and head and neck plans, respectively. The corresponding passing rates for the TPS comparison to film are 99.4%±0.5% and 93.9%±5.1%. Overall, the point dose and film data indicate that log file determined doses are in excellent agreement with measured values. Conclusion: Clinical VMAT QA practice using LINAC treatment log files is a fast and reliable method for patient-specific plan evaluation.

60 APPLIED LIFE SCIENCES↗

Advanced and Additive Manufacturing Technologies for Liquid Rocket Engine Components

Overview of advanced manufacturing and additive manufacturing development at NASA for liquid rocket engines. Presentation includes various material, process, design, and hot-fire testing developments demonstrating the use of advanced components for liquid rocket engines on launch vehicles and in-space systems.

Additive Manufacturing↗

A comprehensive investigation of the accuracy and reproducibility of a multitarget single isocenter VMAT radiosurgery technique

Purpose: Recent trends in stereotactic radiosurgery use multifocal volumetric modulated arc therapy (VMAT) plans to simultaneously treat several distinct targets. Conventional verification often involves low resolution measurements in a single plane, a cylinder, or intersecting planes of diodes or ion chambers. This work presents an investigation into the consistency and reproducibility of this new treatment technique using a comprehensive commissioned high-resolution 3D dosimetry system (PRESAGE{sup ®}/Optical-CT).Methods: A complex VMAT plan consisting of a single isocenter but five separate targets was created in Eclipse for a head phantom containing a cylindrical PRESAGE{sup ®} dosimetry insert of 11 cm diameter and height. The plan contained five VMAT arcs delivering target doses from 12 to 20 Gy. The treatment was delivered to four dosimeters positioned in the head phantom and repeated four times, yielding four separate 3D dosimetry verifications. Each delivery was completely independent and was given after image guided radiation therapy (IGRT) positioning using Brainlab ExacTrac and cone beam computed tomography. A final delivery was given to a modified insert containing a pin-point ion chamber enabling calibration of PRESAGE{sup ®} 3D data to dose. Dosimetric data were read out in an optical-CT scanner. Consistency and reproducibility of the treatment technique (including IGRT setup) was investigated by comparing the dose distributions in the four inserts, and with the predicted treatment planning system distribution.Results: Dose distributions from the four dosimeters were registered and analyzed to determine the mean and standard deviation at all points throughout the dosimeters. A dose standard deviation of <3% was found from dosimeter to dosimeter. Global 3D gamma maps show that the predicted and measured dose matched well [3D gamma passing rate was 98.0% (3%, 2 mm)].Conclusions: The deliveries of the irradiation were found to be consistent and matched the treatment plan, demonstrating high accuracy and reproducibility of both the treatment machine and the IGRT procedure. The complexity of the treatment (multiple arcs) and dosimetry (multiple strong gradients) pose a substantial challenge for comprehensive verification. 3D dosimetry can be uniquely effective in this scenario.

61 RADIATION PROTECTION AND DOSIMETRY↗

An algorithm to calculate a collapsed arc dose matrix in volumetric modulated arc therapy

Purpose: The delivery of volumetric modulated arc therapy (VMAT) is more complex than other conformal radiotherapy techniques. In this work, the authors present the feasibility of performing routine verification of VMAT delivery using a dose matrix measured by a gantry mounted 2D ion chamber array and corresponding dose matrix calculated by an inhouse developed algorithm.Methods: Pinnacle, v9.0, treatment planning system (TPS) was used in this study to generate VMAT plans for a 6 MV photon beam from an Elekta-Synergy linear accelerator. An algorithm was developed and implemented with inhouse computer code to calculate the dose matrix resulting from a VMAT arc in a plane perpendicular to the beam at isocenter. The algorithm was validated using measurement of standard patterns and clinical VMAT plans with a 2D ion chamber array. The clinical VMAT plans were also validated using ArcCHECK measurements. The measured and calculated dose matrices were compared using gamma ({gamma}) analysis with 3%/3 mm criteria and {gamma} tolerance of 1.Results: The dose matrix comparison of standard patterns has shown excellent agreement with the mean {gamma} pass rate 97.7 ({sigma}= 0.4)%. The validation of clinical VMAT plans using the dose matrix predicted by the algorithm and the corresponding measured dose matrices also showed good agreement with the mean {gamma} pass rate of 97.6 ({sigma}= 1.6)%. The validation of clinical VMAT plans using ArcCHECK measurements showed a mean pass rate of 95.6 ({sigma}= 1.8)%.Conclusions: The developed algorithm was shown to accurately predict the dose matrix, in a plane perpendicular to the beam, by considering all possible leaf trajectories in a VMAT delivery. This enables the verification of VMAT delivery using a 2D array detector mounted on a treatment head.

61 RADIATION PROTECTION AND DOSIMETRY↗

Volumetric-Modulated Arc Therapy: Effective and Efficient End-to-End Patient-Specific Quality Assurance

Purpose: To explore an effective and efficient end-to-end patient-specific quality-assurance (QA) protocol for volumetric modulated arc radiotherapy (VMAT) and to evaluate the suitability of a stationary radiotherapy QA device (two-dimensional [2D] ion chamber array) for VMAT QA. Methods and Materials: Three methods were used to analyze 39 VMAT treatment plans for brain, spine, and prostate: ion chamber (one-dimensional absolute, n = 39), film (2D relative, coronal/sagittal, n = 8), and 2D ion chamber array (ICA, 2D absolute, coronal/sagittal, n = 39) measurements. All measurements were compared with the treatment planning system dose calculation either via gamma analysis (3%, 3- to 4-mm distance-to-agreement criteria) or absolute point dose comparison. The film and ion chamber results were similarly compared with the ICA measurements. Results: Absolute point dose measurements agreed well with treatment planning system computed doses (ion chamber: median deviation, 1.2%, range, -0.6% to 3.3%; ICA: median deviation, 0.6%, range, -1.8% to 2.9%). The relative 2D dose measurements also showed good agreement with computed doses (>93% of pixels in all films passing gamma, >90% of pixels in all ICA measurements passing gamma). The ICA relative dose results were highly similar to those of film (>90% of pixels passing gamma). The coronal and sagittal ICA measurements were statistically indistinguishable by the paired t test with a hypothesized mean difference of 0.1%. The ion chamber and ICA absolute dose measurements showed a similar trend but had disparities of 2-3% in 18% of plans. Conclusions: After validating the new VMAT implementation with ion chamber, film, and ICA, we were able to maintain an effective yet efficient patient-specific VMAT QA protocol by reducing from five (ion chamber, film, and ICA) to two measurements (ion chamber and single ICA) per plan. The ICA (Matrixx Registered-Sign , IBA Dosimetry) was validated for VMAT QA, but ion chamber measurements are recommended for absolute dose comparison until future developments correct the ICA angular dependence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and operation of the wide angular-range chopper spectrometer ARCS at the Spallation Neutron Source

The wide angular-range chopper spectrometer ARCS at the Spallation Neutron Source (SNS) is optimized to provide a high neutron flux at the sample position with a large solid angle of detector coverage. The instrument incorporates modern neutron instrumentation, such as an elliptically focused neutron guide, high speed magnetic bearing choppers, and a massive array of {sup 3}He linear position sensitive detectors. Novel features of the spectrometer include the use of a large gate valve between the sample and detector vacuum chambers and the placement of the detectors within the vacuum, both of which provide a window-free final flight path to minimize background scattering while allowing rapid changing of the sample and sample environment equipment. ARCS views the SNS decoupled ambient temperature water moderator, using neutrons with incident energy typically in the range from 15 to 1500 meV. This range, coupled with the large detector coverage, allows a wide variety of studies of excitations in condensed matter, such as lattice dynamics and magnetism, in both powder and single-crystal samples. Comparisons of early results to both analytical and Monte Carlo simulation of the instrument performance demonstrate that the instrument is operating as expected and its neutronic performance is understood. ARCS is currently in the SNS user program and continues to improve its scientific productivity by incorporating new instrumentation to increase the range of science covered and improve its effectiveness in data collection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extraction of Thermal Performance Values from Samples in the Lunar Dust Adhesion Bell Jar

A simulation chamber has been developed to test the performance of thermal control surfaces under dusty lunar conditions. The lunar dust adhesion bell jar (LDAB) is a diffusion pumped vacuum chamber (10-8 Torr) built to test material samples less than about 7 cm in diameter. The LDAB has the following lunar dust stimulant processing capabilities: heating and cooling while stirring in order to degas and remove absorbed water; RF air-plasma for activating the dust and for organic contaminant removal; RF H/He-plasma to simulate solar wind; dust sieving system for controlling particle sizes; and a controlled means of introducing the activated dust to the samples under study. The LDAB is also fitted with an in situ Xe arc lamp solar simulator, and a cold box that can reach 30 K. Samples of thermal control surfaces (2.5 cm diameter) are introduced into the chamber for calorimetric evaluation using thermocouple instrumentation. The object of this paper is to present a thermal model of the samples under test conditions, and to outline the procedure to extract the absorptance, emittance, and thermal efficiency from the pristine and sub-monolayer dust covered samples

Gaier, James R.↗

Extraction of Thermal Performance Values from Samples in the Lunar Dust Adhesion Bell Jar

A simulation chamber has been developed to test the performance of thermal control surfaces under dusty lunar conditions. The lunar dust adhesion bell jar (LDAB) is a diffusion pumped vacuum chamber (10(exp -8) Torr) built to test material samples less than about 7 cm in diameter. The LDAB has the following lunar dust simulant processing capabilities: heating and cooling while stirring in order to degas and remove adsorbed water; RF air-plasma for activating the dust and for organic contaminant removal; RF H/He-plasma to simulate solar wind; dust sieving system for controlling particle sizes; and a controlled means of introducing the activated dust to the samples under study. The LDAB is also fitted with an in situ Xe arc lamp solar simulator, and a cold box that can reach 30 K. Samples of thermal control surfaces (2.5 cm diameter) are introduced into the chamber for calorimetric evaluation using thermocouple instrumentation. The object of this paper is to present a thermal model of the samples under test conditions and to outline the procedure to extract the absorptance, emittance, and thermal efficiency from the pristine and sub-monolayer dust covered samples.

Gaier, James R.↗

Extraction of Thermal Performance Values from Samples in the Lunar Dust Adhesion Bell Jar

A simulation chamber has been developed to test the performance of thermal control surfaces under dusty lunar conditions. The lunar dust adhesion bell jar (LDAB) is a diffusion pumped vacuum chamber (10(exp -8) Torr) built to test material samples less than about 7 cm in diameter. The LDAB has the following lunar dust simulant processing capabilities: heating and cooling while stirring in order to degas and remove adsorbed water; RF air-plasma for activating the dust and for organic contaminant removal; RF H/He-plasma to simulate solar wind; dust sieving system for controlling particle sizes; and a controlled means of introducing the activated dust to the samples under study. The LDAB is also fitted with an in situ Xe arc lamp solar simulator, and a cold box that can reach 30 K. Samples of thermal control surfaces (2.5 cm diameter) are introduced into the chamber for calorimetric evaluation using thermocouple instrumentation. The object of this paper is to present a thermal model of the samples under test conditions and to outline the procedure to extract the absorptance, emittance, and thermal efficiency from the pristine and sub-monolayer dust covered samples.

Gaier, James R.↗

A High-Efficiency, Low Cost, High-Temperature Nanocomposite Soft Magnetic Materials for Vehicle Power Electronics.

The charge components for each gas atomization experiment (GA-1-230, GA-1-232, and GA-1-238) was provided by Aegis and consisted of elemental materials, while MPC provided the master alloy arc melted button castings that were added to yield a charge composition of (Co35Fe65)88Zr7B4Cu. The atmosphere in the melting chamber and connected atomization system was evacuated with a mechanical pump prior to backfilling with ultrahigh purity (UHP grade) Ar. The melt was contained in a bottom tapped zirconia crucible with an alumina stopper rod to seal the exit while heating to a pouring temperature of 1550 – 1575oC. When the desired superheat was reached, the stopper rod was lifted and melt flowed through a yttria stabilized zirconia (YSZ) pour tube with a 3.2 mm orifice and was atomized with Ar from a 45-22-052-409 gas atomization nozzle (or atomization die), having a jet apex angle of 45 degrees with 22 cylindrical gas jets (each with diameter of 1.32 mm or 0.052 inches) arrayed around the axis of a 10.4 mm central bore. The Ar atomization gas supply regulator pressure was set to produce nozzle manifold pressures for the series of runs at a pressure of 450 psi. Secondary gas halos of Ar and He also were added to the interior of the spray chamber at various downstream locations for additional cooling of the atomized droplets and to prevent coalescence of the resulting powder. Powder size analysis and size classification were performed with a full set of ASTM sieves, starting with the 106 µm screen and proceeding down through the 20 µm screen. A Microtrac particle size analyzer was used to verify the size classification results of the particulate resulting from the runs. The resulting powder size distribution results are provided with this report labeled with their respective run numbers (GA-1-230, GA-1-232, and GA-1-238). It should be noted that the size distribution results of the first atomization run were quite acceptable and the same parameters were used for the second and third runs to test the reproducibility for technology transfer purposes.

33 ADVANCED PROPULSION SYSTEMS↗

Large Scale and Multi-Alloy Rocket Engine Component Development using Various Metal Additive Manufacturing Techniques

The NASA Marshall Space Flight Center (MSFC) has been involved with various forms of metallic additive manufacturing (AM) for use in liquid rocket engine component design, development, and testing since 2010. These AM techniques have been demonstrated to significantly reduce hardware cost, shorten fabrication schedules, increase reliability by reducing the number of joints, and improve hardware performance by allowing fabrication of designs not feasible by conventional means. The focus at the NASA MSFC for these metal additive manufacturing techniques include laser powder-bed fusion (L-PBF), blown powder directed energy deposition (DED), arc-based deposition, and Laser Wire Direct Closeout (LWDC). A variety of components have been evaluated and tested including thrust chamber injectors, injector components such as faceplates, regeneratively-cooled combustion chambers, regeneratively-cooled nozzles, gas generator and preburner hardware, and augmented spark igniters. To support these component applications in harsh environments, NASA has advanced a variety of “standard” additive manufacturing alloys such as those in the superalloy-family and also evolved new alloys including GRCop-84, GRCop-42, NASA HR-1, and JBK-75. The purpose of this presentation is to discuss the various component programs at the NASA MSFC using AM to develop, fabricate, and test combustion devices hardware and the evolution of the new additive alloys. One of these projects that will be highlighted is Rapid Analysis and Manufacturing Propulsion Technology (RAMPT), which includes new process development for large scale AM components, multi-metallic AM components, including unique component designs using additive manufacturing. Additional information will be provided on the development of other components, hot-fire testing, post-processing of AM techniques including surface enhancements (polishing) techniques, material and process characterization, future development programs, and dissemination of data to industry partners.

Additive Manufacturing↗

Large Scale and Multi-Alloy Rocket Engine Component Development using Various Metal Additive Manufacturing Techniques

The NASA Marshall Space Flight Center (MSFC) has been involved with various forms of metallic additive manufacturing (AM) for use in liquid rocket engine component design, development, and testing since 2010. These AM techniques have been demonstrated to significantly reduce hardware cost, shorten fabrication schedules, increase reliability by reducing the number of joints, and improve hardware performance by allowing fabrication of designs not feasible by conventional means. The focus at the NASA MSFC for these metal additive manufacturing techniques include laser powder-bed fusion (L-PBF), blown powder directed energy deposition (DED), arc-based deposition, and Laser Wire Direct Closeout (LWDC). A variety of components have been evaluated and tested including thrust chamber injectors, injector components such as faceplates, regeneratively-cooled combustion chambers, regeneratively-cooled nozzles, gas generator and preburner hardware, and augmented spark igniters. To support these component applications in harsh environments, NASA has advanced a variety of “standard” additive manufacturing alloys such as those in the superalloy-family and also evolved new alloys including GRCop-84, GRCop-42, NASA HR-1, and JBK-75. The purpose of this presentation is to discuss the various component programs at the NASA MSFC using AM to develop, fabricate, and test combustion devices hardware and the evolution of the new additive alloys. One of these projects that will be highlighted is Rapid Analysis and Manufacturing Propulsion Technology (RAMPT), which includes new process development for large scale AM components, multi-metallic AM components, including unique component designs using additive manufacturing. Additional information will be provided on the development of other components, hot-fire testing, post-processing of AM techniques including surface enhancements (polishing) techniques, material and process characterization, future development programs, and dissemination of data to industry partners.

Additive Manufacturing↗

The Petrogenetic significance of Plagioclase megacrysts in Archean rocks

The petrogenetic significance of plagioclase megacryst-bearing Archean rocks was considered. It was suggested that these developed in mid-to upper-crustal magma chambers that were repeatedly replenished. Crystallization of megacrysts from a primitive liquid that evolves to an Fe-rich tholeiite (with LREE enrichment) is nearly isothermal and is an equilibrium process. Cumulates probably form near the margins of the chambers and liquids with megacrysts are periodically extracted and can appear as volcanics. Some flows and intrusives are found in arc-like settings in greenstone belts. Megacrystic dikes represent large volumes of melt and dike swarms such as the Metachawan swarm of Ontario suggest multiple sources of similar compositions. A complex series of melt ponding and migration are probable and involve large amounts of liquid.

Morrison, D. A.↗

Microgravity Experiments of Solid Waste Conversion into Useful Commodities

This Summer I participated in two projects at Kennedy Space Center in Cape Canaveral, Florida. The projects focus on the NASA's Deep Space Gateway applications for future Mars travel. All of these projects use recycling technology to use resources found on Earth and on other planets for fuel and other environmental applications. The first project I took the lead on is “Plasma Arc Gasification.” Plasma is a high temperature and very efficient way to process waste to create usable byproducts. The plasma chamber in temperature is comparable to that of the sun and this energy will help create an environment in which the waste can be recycled properly for not only plant support, but also for possible fuel application as well. I preformed the tests in a quartz tube, which is used to hold the waste (cotton, plastics, nylon, paper and a human waste simulant) and the waste is then combusted using O2 (present in air) into gases such as H2, H2O, CH4 and CO2. I determined which gases are present using a Fourier-transform infrared spectroscopy (FTIR) machine, which analyzes the peaks of the gases using liquid nitrogen. Problems arose in the beginning from the reactor emitting electromagnetic waves (EMI) that interfered with the technology of the experiment, specifically the thermocouples. This was solved through multiple tests with the positioning of the thermocouple power supply further away from the plasma reactor. I worked with another intern, Daniel Santander, who developed a space plant chamber which uses CO2 and H2O (harvested from the plasma reactor) to grow plants in space. The chamber possess a CO2 monitor, which controls the amount of gas that enters the chamber, along with a water integration system to supply the amount of water needed for proper plan growth. This technology will then be used for plant growth in space for the Astronauts on future space flights and possibly on the International Space Station (ISS). The second project I worked on is the “Orbital Syngas / Commodity Augmentation Reactor (OSCAR)” which focuses on the issues experienced in long-duration space flight regarding waste disposal. In previous space flight missions, waste was stored on board and returned to Earth for disposal. This technique is not applicable to long space flight missions to Mars due to the rocket being months away from Earth. OSCAR is using microgravity waste disposal techniques to produce fuels from the recycled waste. The waste is converted to syngas through a thermal degradation process. This process helps create an environmentally friendly way to dispose and reuse trash on board the space craft. Currently waste is being tested in the form of cotton and plastics. OSCAR is designed as a microgravity reactor that is currently being tested in a drop tower rig at Glenn Research Center. I helped design the 3D model for the insulation that will line the reactor. The first few trials, I dissolved the plastic of the mold in acetone. This method worked, but was very costly. I then received a silicone material to construct the mold from Swamp Works here at Kennedy. Through multiple trials with the silicone, this method worked best for developing the end pieces of the insulation for the chamber.