Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ALTIMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Ranging performance of satellite laser altimeters

Topographic mapping of the earth, moon and planets can be accomplished with high resolution and accuracy using satellite laser altimeters. These systems employ nanosecond laser pulses and microradian beam divergences to achieve submeter vertical range resolution from orbital altitudes of several hundred kilometers. Here, we develop detailed expressions for the range and pulse width measurement accuracies and use the results to evaluate the ranging performances of several satellite laser altimeters currently under development by NASA for launch during the next decade. Our analysis includes the effects of the target surface characteristics, spacecraft pointing jitter and waveform digitizer characteristics. The results show that ranging accuracy is critically dependent on the pointing accuracy and stability of the altimeter especially over high relief terrain where surface slopes are large. At typical orbital altitudes of several hundred kilometers, single-shot accuracies of a few centimeters can be achieved only when the pointing jitter is on the order of 10 mu rad or less.

Gardner, Chester S.↗

Integration of radar altimeter, precision navigation, and digital terrain data for low-altitude flight

A Kalman filter for the integration of a radar altimeter into a terrain database-dependent guidance system was developed. Results obtained from a low-altitude helicopter flight test data acquired over moderately rugged terrain showed that the proposed Kalman filter removes large disparities in predicted above-ground-level (AGL) altitude in the presence of measurement anomalies and dropouts. Integration of a radar altimeter makes it possible to operate a near-terrain guidance system at or below 50 ft (subject to obstacle-avoidance limitations), whereas without radar altimeter integration, a minimum clearance altitude of 220 AGL is needed, as is suggested by previous work.

Zelenka, Richard E.↗

Study of mass and heat transport of the tropical Atlantic Ocean using models and altimeter data

The specific objectives of this proposal are: (1) to assess the quality of the TOPEX/POSEIDON surface altimeter data in regard to its use for a large, low-frequency monitoring of the surface topography of the tropical Atlantic Ocean; (2) to develop a method, on a demonstration basis, to derive from the tropical Atlantic the depth of the thermocline and the heat content changes from the surface altimeter data field; (3) to develop a method of assimilation of altimeter data into Oceanic General Circulation Models (OGCM's) for the purpose of preparing an operational, permanent, three-dimensional now casting of the tropical Atlantic Ocean (a TOGA objective); and (4) to derive from these models global circulation fields and a time series of mass and meridional heat transports across the tropical Atlantic region (a WOCE objective).

Merle, Jacques↗

Lunar Observer Laser Altimeter observations for lunar base site selection

One of the critical datasets for optimal selection of future lunar landing sites is local- to regional-scale topography. Lunar base site selection will require such data for both engineering and scientific operations purposes. The Lunar Geoscience Orbiter or Lunar Observer is the ideal precursory science mission from which to obtain this required information. We suggest that a simple laser altimeter instrument could be employed to measure local-scale slopes, heights, and depths of lunar surface features important to lunar base planning and design. For this reason, we have designed and are currently constructing a breadboard of a Lunar Observer Laser Altimeter (LOLA) instrument capable of acquiring contiguous-footprint topographic profiles with both 30-m and 300-m along-track resolution. This instrument meets all the severe weight, power, size, and data rate limitations imposed by Observer-class spacecraft. In addition, LOLA would be capable of measuring the within-footprint vertical roughness of the lunar surface, and the 1.06-micron relative surface reflectivity at normal incidence. We have used airborne laser altimeter data for a few representative lunar analog landforms to simulate and analyze LOLA performance in a 100-km lunar orbit. We demonstrate that this system in its highest resolution mode (30-m diameter footprints) would quantify the topography of all but the very smallest lunar landforms. At its global mapping resolution (300-m diameter footprints), LOLA would establish the topographic context for lunar landing site selection by providing the basis for constructing a 1-2 km spatial resolution global, geodetic topographic grid that would contain a high density of observations (e.g., approximately 1000 observations per each 1 deg by 1 deg cell at the lunar equator). The high spatial and vertical resolution measurements made with a LOLA-class instrument on a precursory Lunar Observer would be highly synergistic with high-resolution imaging datasets, and will allow for direct quantification of critical slopes, heights, and depths of features visible in images of potential lunar base sites.

Garvin, James B.↗

Tables for calibrating altimeters and computing altitudes based on the standard atmosphere

During 1925 the assumption of an isothermal atmosphere which was in general use as the standard for the calibration of altimeters in the United States was replaced by a standard atmosphere which assumes an altitude-temperature relation closely corresponding to the average of upper air observations at latitude 40 degrees in this country. The same standard atmosphere had already been adopted somewhat earlier in the United States as the aircraft performance standard. National Advisory Committee for Aeronautics Technical Reports nos. 147 and 218 give necessary constants, tables, and information. However, neither of these reports includes all of the tables required for the computation of actual altitudes nor those readily suitable for use in calibrating altimeters, since the altitude intervals for which data are given are not sufficiently small. The present report has been prepared specifically for these purposes. The formulas which define the standard atmosphere are given in this report, together with other formulas giving the corrections to be applied to the standard altitude in order to obtain the actual altitude when the necessary observations of pressure and temperature are available. The tables necessary for the use of this standard atmosphere in calibrating altimeters and in computing altitudes form the principal part of this report. An example of the computation of actual altitudes from observed pressures and temperatures are given in table IV.

Brombacher, W G↗

Pressure element of constant logarithmic stiffness for temperature compensated altimeter

The usual type of altimeter contains a pressure element, the deflections of which are approximately proportional to pressure changes. An evenly divided altitude scale is secured by using a mechanism between the pressure element and pointer which gives the required motion of the pointer. A temperature-compensated altimeter was constructed at the Bureau of Standards for the Bureau of Aeronautics of the Navy Department which contained a manually operated device for controlling the multiplication of the mechanism to the extent necessary for temperature compensation. The introduction of this device made it difficult to adjust the multiplying mechanism to fit an evenly divided altitude scale. To meet this difficulty a pressure element was designed and constructed which gave deflections which were proportional to altitude; that is, to the logarithm of the pressure. The element consisted of a metal bellows of the sylphon type coupled to an internal helical spring which was designed so as to have a variable number of active coils. This report presents a description of and laboratory data relating to the special pressure element for the altimeter. In addition equations which apply generally to springs and pressure elements of constant logarithmic stiffness are developed, including the deflection and the spacing between the coils in terms of the constants of the helical spring and pressure elements. (author)

Brombacher, W G↗

Radar altimeter calibration using SLR

Clearly a calibration of the TOPEX altimeter (and future TOPEX-class altimeters) which is more accurate and better prepared to meet the demands of global sea level trend monitoring is warranted. TOPEX/Posideon (T/P) is in its second year of data acquisition. If it survives or surpasses the two to five year projected baseline, an unprecedented opportunity for monitoring global sea level trends at mm/y levels will have been lost due to insufficient accuracy in its altimeter calibration. It is therefore paramount to revisit the design of the T/P calibration experiment and implement a more direct approach which better utilizes the accuracy of SLR to perform this needed bias assessment.

Klosko, Steven M.↗

Mean sea surface and geoid gradient comparisons with TOPEX altimeter data

Cycles 4 to 54 of TOPEX data have been analyzed through comparisons with the mean sea surface given on the disturbed geophysical data record (GDR). Two inverted barometer correction procedures were considered for the data reduction. One used a constant atmospheric pressure for all data while the one adopted for use, for most computations, introduced a cycle average pressure. The maximum difference between the two estimates was 3.0 cm with a clear annual signal. With the modified correction the TOPEX sea surface was compared to The Ohio State University (OSU) mean sea surface, given on the GDR, to estimate three translations ( delta x = -2.3 cm; delta y = 25.0 cm; delta z = -0.3 cm) and a bias (43.3 cm) between the two surfaces. The only significant translation is delta y which indicates the reference frame of the TOPEX system differs from that used in the OSU mean sea surface system. The bias between the TOPEX mean sea surface and the OSU mean sea surface was used to estimate an equatorial radius of 6,378,136.55 m based on an 18-cm biased estimate of the TOPEX altimeter. Examination of the average difference, by cycle, between the TOPEX sea surface and the OSU mean sea surface suggested a bias change of 3.1 +/- 2.2 mm/yr with a positive sign indicating the average ocean surface is rising or the altimeter measured distance is decreasing. Models were implemented that solved directly for a bias, bias rate annual/semiannual, and tide correction terms. The computations indicated that a simultaneous solution for this bias, bias rate, and annual/semiannual terms gave the most accurate results. Nonsimultaneous solutions led to slightly different bias rate values. The root mean square difference between the TOPEX sea surface and OSU sea surface, after translation and bias correction, was +/- 17 cm for a typical cycle. Some locations were indentified where the difference could reach 2.3 cm and were repeated over several cycles indicating errors in the mean sea surface. Most of the large differences occur in regions lacking altimeter data prior to the TOPEX/POSEIDON mission and/or areas of significant bathymetric signature. Geoid gradients are needed for the reduction of individual track data to a reference track. The accuracy of the determination of such gradients was determined through the comparison of predicted along-track gradients to the observed gradients. Among four mean sea surfaces tested the best agreement was found with the OSU mean sea surface placed on the TOPEX geophysical data record.

Rapp, Richard H.↗

Determination of ocean tides from the first year of TOPEX/POSEIDON altimeter measurements

An improved geocentric global ocean tide model has been determined using 1 year of TOPEX/POSEIDON altimeter measurements to provide corrections to the Cartwright and Ray (1991) model (CR91). The corrections were determined on a 3 deg x 3 deg grid using both the harmonic analysis method and the response method. The two approaches produce similar solutions. The effect on the tide solution of simultaneously adjusting radial orbit correction parameters using altimeter measurements was examined. Four semidiurnal (N(sub 2), M(sub 2), S(sub 2) and K(sub 2)), four diurnal (Q(sdub 1), O(sub 1), P(sub 1), and K(sub 1)), and three long-period (S(sub sa), M(sub m), and M(sub f)) constituents, along with the variations at the annual frequency, were included in the harmomnic analysis solution. The observed annual variations represents the first global measurement describing accurate seasonal changes of the ocean during an El Nino year. The corrections to the M(sub 2) constituent have an root mean square (RMS) of 3.6 cm and display a clear banding pattern with regional highs and lows reaching 8 cm. The improved tide model reduces the weighted altimeter crossover residual from 9.8 cm RMS, when the CR91 tide model is used, to 8.2 cm on RMS. Comparison of the improved model to pelagic tidal constants determined from 80 tide gauges gives RMS differences of 2.7 cm for M(sub 2) and 1.7 cm for K(sub 1). Comparable values when the CR91 model is used are 3.9 cm and 2.0 cm, respectively. Examination of TOPEX/POSEIDON sea level anomaly variations using the new tide model further confirms that the tide model has been improved.

Ma, X. C.↗

A new approach for determining fully empirical altimeter wind speed model functions

A statistical technique is developed for determining fully empirical model functions relating altimeter backscatter (sigma(sub 0)) measurements to near-surface neutral stability wind speed. By assuming that sigma(sub 0) varies monotonically and uniquely with wind speed, the method requires knowledge only of the separate, rather than joint distribution functions of sigma(sub 0) and wind speed. Analytic simplifications result from using a Weibull distribution to approximate the global ocean wind speed distribution; several different wind data sets are used to demonstrate the validity of the Weibull approximation. The technique has been applied to 1 year of Geosat data. Validation of the new and historical model functions using an independent buoy data set demonstrates that the present model function not only has small overall bias and root mean square (RMS) errors, but yields smaller systematic error trends with wind speed and pseudowave age than previously published models. The present analysis suggests that generally accuracte altimeter model functions can be derived without the use of colocated measurements, nor is additional significant wave height information measured by the altimeter necessary.

Freilich, M. H.↗

Monthly Maps of Sea Surface Height in the North Atlantic and Zonal Indices for the Gulf Stream Using TOPEX/Poseidon Altimeter Data

Monthly Maps of sea surface height are constructed for the North Atlantic Ocean using TOPEX/Poseidon altimeter data. Mean sea surface height is reconstructed using a weighted combination of historical, hydrographic data and a synthetic mean obtained by fitting a Gaussian model of the Gulf Stream jet to altimeter data. The resultant mean shows increased resolution over the hydrographic mean, and incorporates recirculation information that is absent in the synthetic mean. Monthly maps, obtained by adding the mean field to altimeter sea surface height residuals, are used to derive a set of zonal indices that describe the annual cycle of meandering as well as position and strength of the Gulf Stream.

GULF STREAM↗

A High Resolution Radar Altimeter to Measure the Topography of Ice Sheets

This thesis is a reference for the Advanced Application Flight Experiment (AAFE) altimeter. The transmitter and receiver subsections are described and measurements of their current state is provided. During the 1994 NASA Greenland Experiment, the altimeter experienced several hardware malfunctions. The process of returning the radar to its fully operational state is presented in detail and necessary design modifications are explained. An updated radar user's manual is included along with various circuit designs which need to be implemented. The thesis is intended to provide an incoming graduate student with a solid foundation of the fundamentals of AAFE altimeter operation.

Pawul, Rudolf A.↗

A digital elevation model of the Greenland ice sheet and validation with airborne laser altimeter data

A 2.5 km resolution digital elevation model (DEM) of the Greenland ice sheet was produced from the 336 days of the geodetic phase of ERS-1. During this period the altimeter was operating in ice-mode over land surfaces providing improved tracking around the margins of the ice sheet. Combined with the high density of tracks during the geodetic phase, a unique data set was available for deriving a DEM of the whole ice sheet. The errors present in the altimeter data were investigated via a comparison with airborne laser altimeter data obtained for the southern half of Greenland. Comparison with coincident satellite data showed a correlation with surface slope. An explanation for the behavior of the bias as a function of surface slope is given in terms of the pattern of surface roughness on the ice sheet.

Bamber, Jonathan L.↗

Correlations Between Topex Altimeter and Temperature Profile Data in the Equatorial Pacific

Observations of sea-surface heights from satellite altimeters have been a major contributor to monitoring the evolution of the recent major El Nino event. Assimilating altimeter data directly into numerical models only takes advantage of the surface signature provided by the data. However, that surface signature is usually indicative of processes occurring at depth, especially in the equatorial Pacific. In order for assimilation schemes to make maximum use of surface data, it is helpful to have knowledge of how to best extend that data in the vertical to account for that variability. Toward that end, the vertical correlation structure between satellite-observed sea-surface heights and in situ temperature measurements is examined using TOPEX altimeter and TOGA TAO profile data for the period 1993-1998. This time period includes several states of the tropical Pacific, including a perturbed state from 1993-1994, a quiescent state encompassing 1995-1996, and the major ENSO event of 1997-1998. Analyses for each of these periods, as well as the total period will be presented. In addition to analyses at specific depth levels, analyses for particular density surfaces will also be presented.

Adamec, David↗

The Laser Vegetation Imaging Sensor (LVIS): An Airborne Laser Altimeter for Mapping Vegetation and Topography

The Laser Vegetation Imaging Sensor (LVIS) is an airborne laser altimeter designed to quickly and extensively map surface topography as well as the relative heights of other reflecting surfaces within the laser footprint. Since 1997, this instrument has primarily been used as the airborne simulator for the Vegetation Canopy Lidar (VCL) mission, a spaceborne mission designed to measure tree height, vertical structure and ground topography (including sub-canopy topography). LVIS is capable of operating from 500 m to 10 km above ground level with footprint sizes from 1 to 60 m. Laser footprints can be randomly spaced within the 7 degree telescope field-of-view, constrained only by the operating frequency of the ND:YAG Q-switched laser (500 Hz). A significant innovation of the LVIS altimeter is that all ranging, waveform recording, and range gating are performed using a single digitizer, clock base, and detector. A portion of the outgoing laser pulse is fiber-optically fed into the detector used to collect the return signal and this entire time history of the outgoing and return pulses is digitized at 500 Msamp/sec. The ground return is then located using software digital signal processing, even in the presence of visibly opaque clouds. The surface height distribution of all reflecting surfaces within the laser footprint can be determined, for example, tree height and ground elevation. To date, the LVIS system has been used to monitor topographic change at Long Valley caldera, CA, as part of NASA's Topography and Surface Change program, and to map tree structure and sub-canopy topography at the La Selva Biological Research Station in Costa Rica, as part of the pre-launch calibration activities for the VCL mission. We present results that show the laser altimeter consistently and accurately maps surface topography, including sub-canopy topography, and vegetation height and structure. These results confirm the measurement concept of VCL and highlight the benefits of airborne prototypes of spaceborne instruments.

Bryan, J.↗

Lidar Altimeter Measurements of Canopy Structure: Methods and Validation for Closed Canopy, Broadleaf Forests

Lidar altimeter observations of vegetated landscapes provide a time-resolved measure of laser pulse backscatter energy from canopy surfaces and the underlying ground. Airborne lidar altimeter data was acquired using the Scanning Lidar Imager of Canopies by Echo Recovery (SLICER) for a successional sequence of four, closed-canopy, deciduous forest stands in eastern Maryland. The four stands were selected so as to include a range of canopy structures of importance to forest ecosystem function, including variation in the height and roughness of the outer-most canopy surface and the vertical organization of canopy stories and gaps. The character of the SLICER backscatter signal is described and a method is developed that accounts for occlusion of the laser energy by canopy surfaces, transforming the backscatter signal to a canopy height profile (CHP) that quantitatively represents the relative vertical distribution of canopy surface area. The transformation applies an increased weighting to the backscatter amplitude as a function of closure through the canopy and assumes a horizontally random distribution of the canopy components. SLICER CHPs, averaged over areas of overlap where lidar ground tracks intersect, are shown to be highly reproducible. CHP transects across the four stands reveal spatial variations in vegetation, at the scale of the individual 10 m diameter laser footprints, within and between stands. Averaged SLICER CHPs are compared to analogous height profile results derived from ground-based sightings to plant intercepts measured on plots within the four stands. Tbe plots were located on the segments of the lidar ground tracks from which averaged SLICER CHPs were derived, and the ground observations were acquired within two weeks of the SLICER data acquisition to minimize temporal change. The differences in canopy structure between the four stands is similarly described by the SLICER and ground-based CHP results, however a Chi-square test of similarity documents differences that are statistically significant. The differences are discussed in terms of measurement properties that define the smoothness of the resulting CHPs and Lidar Altimeter Measurements of Canopy Structure - Harding et al. canopy properties that may vertically bias the CHP representations of canopy structure. The statistical differences are most likely due to the more noisy character of the ground-based CHPs, especially high in the canopy where ground-based sightings are rare resulting in an underestimate of canopy surface area and height, and to departures from the assumption of horizontal randomness which bias the CHPs toward the observer (upward for SLICER and downward for ground-based CHPs). The results demonstrate that the SLICER observations reliably provide a measure of canopy structure that reveals ecologically interesting structural variations such as those characterizing a successional sequence of closed-canopy, broadleaf forest stands.

Harding, D. J.↗

Return Echoes from Medium-Large Footprint Laser Altimeters

For just over 10 years, NASA Goddard Space Flight Center has been at the forefront of developing return echo laser altimeters and analysis techniques for a variety of both space and airborne applications. In 1991, the Laser Remote Sensing Branch began investigating the use of medium-large diameter footprint return waveforms for measuring vegetation height and structure and sub-canopy topography. Over the last 8 years, using a variety of profiling and scanning laser altimeters (i.e. ATLAS, SLICER, SLA, and LVIS), we have collected return waveforms over a variety of terrestrial surface types. We describe the effects of instrument characteristics and within-footprint surface structure on the shape of the return waveform and suggest several techniques for extracting this information. Specifically for vegetation returns, we describe the effects of canopy parameters such as architecture and closure on the shape of the return waveform. Density profiles, statistics, and examples from a variety of vegetation types will be presented, as well as comparisons with small-footprint laser altimeter data.

Blair, J. Bryan↗

Future Applications Using Return-Pulse Correlation from Imaging Laser Altimeters

The Laser Vegetation Imaging Sensor (LVIS) is an airborne, wide-swath, digitization-only laser altimeter capable of collecting full return waveforms (i.e. echoes) from laser footprints ranging in diameter from 1 to 80 m across up to a 1 km wide data swath. The return waveform can be used to enhance the accuracy of laser ranging and to provide information about the vertical structure of vegetation and topography within each laser footprint. Although extremely small laser footprints (< 1 0 cm diameter) generally return simple, impulse responses to their target surface, larger footprints typically exhibit complex returns representing the diverse vertical distributions of surfaces contained in each footprint. Only a handful of airborne and spaceborne laser altimeters record the return echo or return pulse that is reflected from the Earth's surface (i.e. NASA's LVIS, SLA, VCL, and GLAS laser altimeters). Waveforms are currently interpreted to extract a timing or ranging point or points to represent the mean ground elevation or the vertical height of vegetation. But, recent progress using pulse shape correlation techniques shows promise for a variety of science applications involving change detection of surface topography and vegetation as well as potential for improving data processing by correlating images or crossovers to solve systematic biases. We show example correlation images from LVIS and discuss instrument design implications and potential science applications.

Blair, J. Bryan↗