Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AIRFLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Effect of Liner Cooling Flow on Combustor Emissions for Commercial Supersonics Technology

An overview is provided of a parametric study conducted to study the effect of liner cooling airflow rates on NOx emissions of a seven-element lean-direct injection (LDI) module with radial airflow main swirlers. The goal of the CFD study was to determine the increase in cooling flow rate at which the NOx emissions would exceed 20% of the predicted emissions with zero liner cooling flow. The Open version of the National Combustion Code (OpenNCC) was used to perform two-phase reacting flow computations with a new LDI injection module design with radial airflow swirlers instead of axial airflow swirlers. CFD analysis with OpenNCC predicted a 20% increase in EINOx emissions was reached when the liner cooling airflow rate was increased to 15% of the baseline combustor airflow rate. The liner cooling flow rate was predicted to have a non-linear effect on increase in overall EINOx of the seven element LDI injection module.

CFD↗

Effect of Liner Cooling Flow on Combustor Emissions for Commercial Supersonics Technology

An overview is provided of a parametric study conducted to study the effect of liner cooling airflow rates on NOx emissions of a seven-element lean-direct injection (LDI) module with radial airflow main swirlers. The goal of the CFD study was to determine the increase in cooling flow rate at which the NOx emissions would exceed 20% of the predicted emissions with zero liner cooling flow. The Open version of the National Combustion Code (OpenNCC) was used to perform two-phase reacting flow computations with a new LDI injection module design with radial airflow swirlers instead of axial airflow swirlers. CFD analysis with OpenNCC predicted a 20% increase in EINOx emissions was reached when the liner cooling airflow rate was increased to 15% of the baseline combustor airflow rate. The liner cooling flow rate was predicted to have a non-linear effect on increase in overall EINOx of the seven element LDI injection module.

CFD↗

Designing for Supply and Return Air System Interaction in Residential Buildings

Standard practice for HVAC return design has evolved from running a dedicated return to each room with a supply, to systems with returns in more centrally located areas of the home with jump ducts, transfer grilles, or simply door undercuts used as return air pathways from isolated rooms . In these latter systems, hallways and stairwells act as large open ducts for conveying air back to a single (or sometimes multiple) central return. When partition doors to an isolated room are closed, the return airflow resistance goes up, significantly impacting airflow balance if an adequate relief pathway is not installed. Airflow imbalances can lead to comfort and building durability issues and increased envelope leakage. To combat this, some jurisdictions have requirements for return air pathways. The supply system topology – or layout - impacts the airflow balance stability in response to adjustments of return pathway resistances. Branching supply topologies typically have reduced static pressure after each split. The static pressure at the final split will be lower than the primary supply plenum. Because of this, if there is a restriction in a room’s return path, supply airflow will tend to redistribute to adjacent ducts at the end of the branch. A properly designed trunk and branch supply system can effectively equalize static pressure by reducing the cross sectional area after each takeoff . Maintaining static pressure within the trunk will reduce the system’s sensitivity to changes in return paths. However, in practice, it is difficult to design and time consuming to install a complex supply plenum. Velocity effects and poor takeoff placement also impact airflow balance. This fact sheet considers return systems in three main categories: distributed, with a return duct to each room; multiple central, with one return grille on each floor of a home; and single central, with a single return grille located near the air handling unit. Three supply categories are also considered: radial splitter box, trunk and branch, and home-run with all ducts connecting directly to a central manifold. A complete description of the modeling work and results can be found in the companion technical report.

buildings↗

Loose Belt Fault Detection and Virtual Flow Meter Development Using Identified Data-driven Energy Model for Fan Systems

An energy model that correlates fan airflow, head, speed, and system power input is essential to detect device faults and optimize control strategies in fan systems. Since the application of variable-frequency drives (VFDs) makes the motor-efficiency data published by manufacturers inapplicable for VFD–motor–fan systems, the fan efficiency and drive (belt–motor–VFD) efficiency must be identified for each individual system to obtain accurate energy models. The objectives of this paper are to identify an energy model of existing VFD–motor–fan systems using available experimental data and demonstrate its applications in loose belt fault detection and virtual airflow meter development for optimal control. First, an approach is developed to identify the fan head, fan efficiency, and drive-efficiency curves using available fan head, speed, and system power input as well as temporarily measured airflow rate without measuring shaft power. Then, the energy model is identified for an existing VFD–motor–fan system. Finally, the identified model is applied to detect the slipped belt faults and develop the virtual airflow meter. The experiment results reveal that the developed approach can effectively obtain the energy model of VFD–motor–fan systems and the model can be applied to effectively detect slipped belt faults and accurately calculate the fan airflow rate.

42 ENGINEERING↗

Transonic performance of Mach 2.65 auxiliary flow axisymmetric inlet

Transonic experimental performance for a large scale Mach 2.65 axisymmetric inlet model with auxiliary airflow systems are presented. The inlet model incorporated both centerbody and cowl auxiliary airflow systems. When the centerbody system was fully open the performance at the simulated compressor face was such that, at 0.10 total pressure distortion the total capture mass flow ratio increased 0.055 and 0.051 and the total pressure recovery increased 0.015 and 0.012 at Mach 0.9 and 1.3, respectively. Flow separation on the centerbody resulted in supercritical centerbody auxiliary throat flow prior to attainment of choked main duct throat flow. Cowl auxiliary airflow had a detrimental effect on compressor-face performance. To overcome the detrimental effect, alternate cowl auxiliary airflow systems are described for efficient merging of auxiliary and main duct airflows and for providing similar auxiliary and main duct throat choking characteristics.

Santman, D. M.↗

Acceleration wave breakup of liquid jets with airstreams

Characteristic mean drop diameters were determined for downstream and upstream injection into nonswirling and swirling airflows. The effects of the aerodynamic and liquid surface forces on the mean drop size were obtained with a scanning radiometer. Water jet breakup was studied primarily in the acceleration wave regime with values of WeRe 10 to the 6th power and the following empirical expression was obtained: D(o)/D(m) =C (WeRe) to the 0.4, power where D(o) and D(m) are the orifice and mean drop diameters, respectively. We and Re are the Weber and Reynolds numbers defined as repectively, We = rho(a)D(o)V(r)/sigma and Re = D(o)V(r)/nu, where V(r) and rho(a) are airstream relative velocity and density, respectively, and sigma and nu are surface tension and kinematic viscosity of the liquid, respectively. The proportionally constant C was evaluated as follows: for downstream injection, C = 0.023 with nonswirling airflow, and C = 0.027 with swirling airflow. For upstream injection, the empirical expression D(o)/D(m) = 0.0045 (WeRe) to the 0.5 power was obtained with nonswirling airflow. Experimental conditions included a water flow rate of 68 liter per hour and an airflow rate per unit area range of 4.6 to 25.2 gm/sq cm sec at 293 K and atmospheric pressure.

Ingebo, R. D.↗

Computational Fluid Dynamics Uncertainty Analysis for Payload Fairing Spacecraft Environmental Control Systems

Spacecraft thermal protection systems are at risk of being damaged due to airflow produced from Environmental Control Systems. There are inherent uncertainties and errors associated with using Computational Fluid Dynamics to predict the airflow field around a spacecraft from the Environmental Control System. This proposal describes an approach to validate the uncertainty in using Computational Fluid Dynamics to predict airflow speeds around an encapsulated spacecraft. The research described here is absolutely cutting edge. Quantifying the uncertainty in analytical predictions is imperative to the success of any simulation-based product. The method could provide an alternative to traditional"validation by test only'' mentality. This method could be extended to other disciplines and has potential to provide uncertainty for any numerical simulation, thus lowering the cost of performing these verifications while increasing the confidence in those predictions. Spacecraft requirements can include a maximum airflow speed to protect delicate instruments during ground processing. Computationaf Fluid Dynamics can be used to veritY these requirements; however, the model must be validated by test data. The proposed research project includes the following three objectives and methods. Objective one is develop, model, and perform a Computational Fluid Dynamics analysis of three (3) generic, non-proprietary, environmental control systems and spacecraft configurations. Several commercially available solvers have the capability to model the turbulent, highly three-dimensional, incompressible flow regime. The proposed method uses FLUENT and OPEN FOAM. Objective two is to perform an uncertainty analysis of the Computational Fluid . . . Dynamics model using the methodology found in "Comprehensive Approach to Verification and Validation of Computational Fluid Dynamics Simulations". This method requires three separate grids and solutions, which quantify the error bars around Computational Fluid Dynamics predictions. The method accounts for all uncertainty terms from both numerical and input variables. Objective three is to compile a table of uncertainty parameters that could be used to estimate the error in a Computational Fluid Dynamics model of the Environmental Control System /spacecraft system. Previous studies have looked at the uncertainty in a Computational Fluid Dynamics model for a single output variable at a single point, for example the re-attachment length of a backward facing step. To date, the author is the only person to look at the uncertainty in the entire computational domain. For the flow regime being analyzed (turbulent, threedimensional, incompressible), the error at a single point can propagate into the solution both via flow physics and numerical methods. Calculating the uncertainty in using Computational Fluid Dynamics to accurately predict airflow speeds around encapsulated spacecraft in is imperative to the success of future missions.

Groves, Curtis E.↗

Dissertation Defense Computational Fluid Dynamics Uncertainty Analysis for Payload Fairing Spacecraft Environmental Control Systems

Spacecraft thermal protection systems are at risk of being damaged due to airflow produced from Environmental Control Systems. There are inherent uncertainties and errors associated with using Computational Fluid Dynamics to predict the airflow field around a spacecraft from the Environmental Control System. This paper describes an approach to quantify the uncertainty in using Computational Fluid Dynamics to predict airflow speeds around an encapsulated spacecraft without the use of test data. Quantifying the uncertainty in analytical predictions is imperative to the success of any simulation-based product. The method could provide an alternative to traditional "validation by test only" mentality. This method could be extended to other disciplines and has potential to provide uncertainty for any numerical simulation, thus lowering the cost of performing these verifications while increasing the confidence in those predictions. Spacecraft requirements can include a maximum airflow speed to protect delicate instruments during ground processing. Computational Fluid Dynamics can be used to verify these requirements; however, the model must be validated by test data. This research includes the following three objectives and methods. Objective one is develop, model, and perform a Computational Fluid Dynamics analysis of three (3) generic, non-proprietary, environmental control systems and spacecraft configurations. Several commercially available and open source solvers have the capability to model the turbulent, highly three-dimensional, incompressible flow regime. The proposed method uses FLUENT, STARCCM+, and OPENFOAM. Objective two is to perform an uncertainty analysis of the Computational Fluid Dynamics model using the methodology found in "Comprehensive Approach to Verification and Validation of Computational Fluid Dynamics Simulations". This method requires three separate grids and solutions, which quantify the error bars around Computational Fluid Dynamics predictions. The method accounts for all uncertainty terms from both numerical and input variables. Objective three is to compile a table of uncertainty parameters that could be used to estimate the error in a Computational Fluid Dynamics model of the Environmental Control System /spacecraft system. Previous studies have looked at the uncertainty in a Computational Fluid Dynamics model for a single output variable at a single point, for example the re-attachment length of a backward facing step. For the flow regime being analyzed (turbulent, three-dimensional, incompressible), the error at a single point can propagate into the solution both via flow physics and numerical methods. Calculating the uncertainty in using Computational Fluid Dynamics to accurately predict airflow speeds around encapsulated spacecraft in is imperative to the success of future missions.

CFD↗

Dissertation Defense: Computational Fluid Dynamics Uncertainty Analysis for Payload Fairing Spacecraft Environmental Control Systems

Spacecraft thermal protection systems are at risk of being damaged due to airflow produced from Environmental Control Systems. There are inherent uncertainties and errors associated with using Computational Fluid Dynamics to predict the airflow field around a spacecraft from the Environmental Control System. This paper describes an approach to quantify the uncertainty in using Computational Fluid Dynamics to predict airflow speeds around an encapsulated spacecraft without the use of test data. Quantifying the uncertainty in analytical predictions is imperative to the success of any simulation-based product. The method could provide an alternative to traditional validation by test only mentality. This method could be extended to other disciplines and has potential to provide uncertainty for any numerical simulation, thus lowering the cost of performing these verifications while increasing the confidence in those predictions.Spacecraft requirements can include a maximum airflow speed to protect delicate instruments during ground processing. Computational Fluid Dynamics can be used to verify these requirements; however, the model must be validated by test data. This research includes the following three objectives and methods. Objective one is develop, model, and perform a Computational Fluid Dynamics analysis of three (3) generic, non-proprietary, environmental control systems and spacecraft configurations. Several commercially available and open source solvers have the capability to model the turbulent, highly three-dimensional, incompressible flow regime. The proposed method uses FLUENT, STARCCM+, and OPENFOAM. Objective two is to perform an uncertainty analysis of the Computational Fluid Dynamics model using the methodology found in Comprehensive Approach to Verification and Validation of Computational Fluid Dynamics Simulations. This method requires three separate grids and solutions, which quantify the error bars around Computational Fluid Dynamics predictions. The method accounts for all uncertainty terms from both numerical and input variables. Objective three is to compile a table of uncertainty parameters that could be used to estimate the error in a Computational Fluid Dynamics model of the Environmental Control System spacecraft system.Previous studies have looked at the uncertainty in a Computational Fluid Dynamics model for a single output variable at a single point, for example the re-attachment length of a backward facing step. For the flow regime being analyzed (turbulent, three-dimensional, incompressible), the error at a single point can propagate into the solution both via flow physics and numerical methods. Calculating the uncertainty in using Computational Fluid Dynamics to accurately predict airflow speeds around encapsulated spacecraft in is imperative to the success of future missions.

Fluid Dynamics↗

Flexible Micropost Arrays for Shear Stress Measurement

Increased fuel costs, heightened environmental protection requirements, and noise abatement continue to place drag reduction at the forefront of aerospace research priorities. Unfortunately, shortfalls still exist in the fundamental understanding of boundary-layer airflow over aerodynamic surfaces, especially regarding drag arising from skin friction. For example, there is insufficient availability of instrumentation to adequately characterize complex flows with strong pressure gradients, heat transfer, wall mass flux, three-dimensionality, separation, shock waves, and transient phenomena. One example is the acoustic liner efficacy on aircraft engine nacelle walls. Active measurement of shear stress in boundary layer airflow would enable a better understanding of how aircraft structure and flight dynamics affect skin friction. Current shear stress measurement techniques suffer from reliability, complexity, and airflow disruption, thereby compromising resultant shear stress data. The state-of-the-art for shear stress sensing uses indirect or direct measurement techniques. Indirect measurements (e.g., hot-wire, heat flux gages, oil interferometry, laser Doppler anemometry, small scale pressure drag surfaces, i.e., fences) require intricate knowledge of the studied flow, restrictive instrument arrangements, large surface areas, flow disruption, or seeding material; with smaller, higher bandwidth probes under development. Direct measurements involve strain displacement of a sensor element and require no prior knowledge of the flow. Unfortunately, conventional "floating" recessed components for direct measurements are mm to cm in size. Whispering gallery mode devices and Fiber Bragg Gratings are examples of recent additions to this type of sensor with much smaller (m) sensor components. Direct detection techniques are often single point measurements and difficult to calibrate and implement in wind tunnel experiments. In addition, the wiring, packaging, and installation of delicate micro-electromechanical devices impede the use of most direct shear sensors. Similarly, the cavity required for sensing element displacement is sensitive to particulate obstruction. This work was focused on developing a shear stress sensor for use in subsonic wind tunnel test facilities applicable to an array of test configurations. The non-displacement shear sensors described here have minimal packaging requirements resulting in minimal or no disturbance of boundary layer flow. Compared to previous concepts, device installation could be simple with reduced cost and down-time. The novelty lies in the creation of low profile (nanoscale to 100 μm) micropost arrays that stay within the viscous sub-layer of the airflow. Aerodynamic forces, which are related to the surface shear stress, cause post deflection and optical property changes. Ultimately, a reliable, accurate shear stress sensor that does not disrupt the airflow has the potential to provide high value data for flow physics researchers, aerodynamicists, and aircraft manufacturers leading to greater flight efficiency arising from more in-depth knowledge on how aircraft design impacts near surface properties.

Wohl, Christopher J.↗

Experimental Investigation of the Effect of Atomizing Electrospray Nozzles on the Cooling and Reduced Humidification of Air

Separating sensible and latent cooling have shown the potential to reduce energy consumption in A/C systems for building HVAC applications. Several technologies exist based on vapor-compression refrigeration, enthalpy wheels, chemical adsorption and absorption materials, and mechanical cooling. However, their thermodynamics limits and high energy consumption hinder their deployment in hot and humid climatic regions. This paper focuses on separating sensible and latent cooling by using a new thermodynamics process and in-kind (i.e., non-vapor compression-based) technology. Highly electrically charged water droplets were sprayed in the airflow. These droplets attracted water vapor molecules to their surfaces and promoted condensation. The phenomenon was the result of simultaneous dielectrophoresis and electro-diffusion interactions. Studies in the literature have shown that using multiple capillary electrodes reduced air moisture by up to 5% when using nanometer-size droplets in the spray. Unfortunately, these studies were limited to low airflow rates, and the objective of this paper was to investigate how to scale up this in-kind approach to airflows typical of buildings. In the present paper, droplets of micrometer size were utilized to control the humidity for a 5-cfm flow rate. While this airflow was still low for building applications, it was 100 times fold the airflows in the literature studies. The air was tested at 20°C and at 50 and 80% relative humidity. A two-fluid atomizing nozzle produced the droplets in the spray, and high DC electric potential, up to 25 kV, was used to charge the fine droplets electrically. The air atomizing nozzle with high voltage potential resembled an evaporative cooler process. However, a measurable reduction of the absolute humidity of up to 2% was observed compared to the case of the nozzle with no high voltage potential. The entire device had one small nozzle selected from off-the-shelf components and had less than a 9 cm2 footprint area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quasi‐dynamic breathing model of the lung incorporating viscoelasticity of the lung tissue

Abstract We advanced a novel model to calculate viscoelastic lung compliance and airflow resistance in presence of mucus, accounting for the quasi‐linear viscoelastic stress–strain response of the parenchyma (alveoli) tissue. We adapted a continuum‐based numerical modeling approach for the lung, integrating the fluid mechanics of the airflow within individual generations of the bronchi and alveoli. The model accounts for elasticity of the deformable bronchioles, resistance to airflow due to the presence of mucus within the bronchioles, and subsequent mucus flow. Simulated quasi‐dynamic inhalation and expiration cycles were used to characterize the net compliance and resistance of the lung, considering the rheology of the mucus and viscoelastic properties of the parenchyma tissue. The structure and material properties of the lung were identified to have an important contribution to the lung compliance and airflow resistance. The secondary objective of this work was to assess whether a higher frequency and smaller volume of harmonic air flow rate compared to a normal ventilator breathing cycle enhanced mucus outflow. Results predict, lower mucus viscosity and higher excitation frequency of breathing are favorable for the flow of mucus up the bronchi tree, towards the trachea.

60 APPLIED LIFE SCIENCES↗

Operator learning for energy-efficient building ventilation control with computational fluid dynamics simulation of a real-world classroom

Energy-efficient ventilation control plays an important role in reducing building energy consumption while ensuring occupant health and comfort. While Computational Fluid Dynamics (CFD) simulations provide detailed and physically accurate representations of indoor airflow, their high computational cost limits their use in real-time building control. In this work, we present a neural operator learning framework that combines the physical accuracy of CFD with the computational efficiency of machine learning to enable building ventilation control with the high-fidelity fluid dynamics models. Our method jointly optimizes the airflow supply rates and vent angles to reduce energy use and adhere to air quality constraints. We train an ensemble of neural operator transformer models to learn the mapping from building control actions to airflow fields using high-resolution CFD data. This learned neural operator is then embedded in an optimization-based control framework for building ventilation control. Experimental results show that our approach achieves significant energy savings compared to maximum airflow rate control, rule-based control, as well as data-driven control methods using spatially averaged CO 2 prediction and deep learning–based reduced-order models, while consistently maintaining safe indoor air quality. These results highlight the practicality and scalability of our method in maintaining energy efficiency and indoor air quality in real-world buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Data Processing Pipeline To Extract A Knowledge Graph From Heterogeneous Data For Socio-technical Analysis Of Critical Infrastructure Influence

The code is written in Python and consists of the following pipeline that is implemented in Apache Airflow. This pipeline intends to understand the companies that are directly or indirectly involved with a type of critical infrastructure system at some point in that system's lifecycle. The pipeline takes a configuration file that specifies a list of initial companies to consider, a geographic region of interest, and a set of SEC form types as well as other data sources (e.g. CrunchBase) from which to extract entities and relations. There are four main components to this pipeline as currently implemented: Entity Extraction, Network Construction, Analysis, and Visualization. First, Entity Extraction, is implemented as the `topear-extract_organizations` Apache Airflow workflow. Given an initial query that specifies a geographic region of interest and a time interval, the software will extract CI facilities of interest and organizations that have a direct influence relationship to those facilities (e.g. ownership). During the course of the LDRD, we focused on Electric Vehicle charging stations and this information is available via the Department of Energy (DOE) database on fueling stations maintained by NREL. Within the context of the DOE CESER project, we have focused on Battery Energy Storage Systems (BESS). Second, the Network Extraction component will iteratively construct a social network graph given the set of organizations and people extracted in the previous step. Organizations (and eventually People if desired) are then fed as a query to the `topgear-construct_social_network` Apache Airflow workflow which given a set of initial companies and data sets (e.g. SEC EDGAR form types, OpenCorporates, Crunchbase). This Airflow workflow will iteratively query such data sources to discover relationships with new organizations and people. For example, this module can iteratively query SEC EDGAR for metadata that documents the number of each type of form for the given set of companies and their location. This forms metadata represents a catalog of data sources from SEC EDGAR for the extracted social network knowledge graph. The pipeline then downloads these forms from the website and saves them in a build directory for further processing. These documents are then parsed for entities and relations. Again, we note that in additional to SEC data sources, this step can also pull in information on organizations via API services such as CrunchBase and OpenCorporates or bulk data sources. At the end of this step, the resultant social network, the Critical Infrastructure network, and the edges that encode relationships between organizations and CI facilities, form the Adversarial Socio-Technical Network (ASTN) that informs the analysis. Third, the Analysis component processes these generated ASTN. Previously, that has included the ability to compare prevalence of different vendors for a given infrastructure component type across different regions as well as identify common public and private investors across those vendors. This was demonstrated for EV Charging Stations across several different metropolitan areas within an IEEE PES GridEdge publication. More recently, we have looked at ways to identify infrastructure owners and operators of BESS with the most nameplate capacity across different states as well as other indictors of risk resulting from changes in ownership over time. Finally, the Visualization component consists of an HTML/CSS/JS framework by which users can interact geospatial, operational, and organizational relationships across a given portfolio of Critical Infrastructure facilities. The objective is to provide a library of UI/UX modules that can be repurposed for stakeholder-specific dashboards. All of the modules are related via a common event model that enables UI actions in one view to percolate across the other views.

Weaver, Gabriel [Idaho National Laboratory (INL), ↗

Building ControlScore: General Service Administration Office Building Deployment

Improvements to building control systems can lead to energy savings and increased occupant comfort. In an optimized system, process variables such as air temperature will closely follow their desired setpoints and avoid excess energy use. Typically, experts must manually inspect individual control loops to identify poor performance and opportunities for improvement. However, this approach is difficult in modern buildings that have a prohibitively large number of controllers. To address this issue, Pacific Northwest National Laboratory (PNNL) created the ControlScore concept, which takes operating data from the many controllers within a building and generates standardized scores for each loop on a scale of 0 to 10 (a score of 0 indicates poor control, a score of 10 indicates good control). PNNL applied the Building ControlScore application to all available data from a General Services Administration office building within the period of January 1, 2023, to March 9, 2023. The building scored a 4.7 overall, with all 74 of the building’s loops fitting a roughly normal distribution centered around 5. These results indicate that the analyzed systems have below-average performance with room for improvement, especially in the poorly scored systems. Airflow loops tended to have much lower scores than zone temperature loops. The lowest and highest performing systems in the building section were identified, as were all loops with a score less than 1. While the ControlScore identifies loops and systems that aren’t meeting their designated setpoints, it does not indicate the cause of those issues. For example, consider a supply air terminal unit’s airflow loop that received a low score due to it delivering less air than specified by the setpoint. The lower-than-desired airflow could be due to equipment limitations (e.g., the terminal unit or duct serving is too small to accommodate that airflow), malfunctioning equipment (e.g., a stuck damper or bad sensor), or something else entirely. The ControlScore does not diagnose problems it simply identifies the symptoms that can be explored and addressed by building operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Glovebox CFD Analysis: Low-Flow, Laminar CFD Analysis of Glovebox Ventilation and Humidity Transport in Ansys Fluent 2025 R1

There are gloveboxes that frequently exceed the 30% relative humidity level required for operations. These exceedances result in alternative operations needing to be utilized. This report documents a computational fluid dynamics (CFD) analysis performed to characterize airflow and humidity transport within a representative glovebox under nominal, low-flow conditions. The analysis focuses on establishing the flow regime, identifying transport-limited regions, and evaluating the implications of laminar flow on humidity removal. A single-phase, laminar flow model with a species transport model was used to represent air and water vapor mixing. Results demonstrate that, at the nominal flow rates, airflow is laminar with weak mixing, which will result in long residence times, tens of minutes long or more, in low-velocity regions. These conclusions suggests that humidity reduction is transport-limited. This analysis provides qualitative insight into airflow structure and humidity transport trends. In addition to characterization of glovebox airflow and humidity transport, results are intended to inform experimental validation and future transient modeling efforts.

42 ENGINEERING↗

Performance Simulation and Analysis of Occupancy-Based Control for Office Buildings with Variable-Air-Volume Systems

Variable-air-volume (VAV) systems are used in many office buildings. The minimum airflow rate setting of VAV terminal boxes has a significant impact on both energy consumption and indoor air quality. Conventional controls usually have the terminal’s minimum airflow rate at a constant (e.g., 30% or more of the terminal design airflow rate), irrespective of the occupancy status, which may cause problems, such as excessive simultaneous heating and cooling, under ventilation, and thermal comfort issues. This paper examines the potential of energy savings from occupancy-based controls (OBCs). The sensed occupancy information, either occupant presence or people count, is used to determine the airflow rate of terminal boxes, the thermostat setpoints, and the lighting control. Using EnergyPlus, a whole-building energy modeling software, the energy savings of OBC strategies are evaluated for representative existing medium office buildings in the U.S. The simulation results show that the conventional OBC, based on occupant presence sensing, can save 8% of whole-building energy use in Miami (hot climate) for systems without air-side economizer and about 13% in both Baltimore (mixed climate) and Chicago (cold climate). Comparatively, the advanced OBC, based on people counting, can save 8% in Miami to 23% in Baltimore for systems with economizers. The outdoor-air fraction of the supply air from air-handling units significantly affects the potential energy savings from the advanced OBC strategy. In addition to energy savings, the advanced OBC satisfies the zone ventilation during all occupied hours over the whole year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Inlet-engine matching for SCAR including application of a bicone variable geometry inlet

Airflow characteristics of variable cycle engines (VCE) designed for Mach 2.32 can have transonic airflow requirements as high as 1.6 times the cruise airflow. This is a formidable requirement for conventional, high performance, axisymmetric, translating centerbody mixed compression inlets. An alternate inlet is defined, where the second cone of a two cone center body collapses to the initial cone angle to provide a large off-design airflow capability, and incorporates modest centerbody translation to minimize spillage drag. Estimates of transonic spillage drag are competitive with those of conventional translating centerbody inlets. The inlet's cruise performance exhibits very low bleed requirements with good recovery and high angle of attack capability.

Wasserbauer, J. F.↗