Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AIR-WATER INTERFACE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

149 records · Page 9

Onset dynamics of air-water menisci on rock fracture surfaces

Information on menisci dynamics and equilibrium contact angles, θ e , is needed for modeling multiphase flow of fluids in geologic formations. The wettability of fracture faces is relevant to applications such as waterflooding in enhanced oil recovery and evaluation of caprock integrity for geologic carbon sequestration. We investigated the vertical capillary rise of air-water menisci on exposed fracture faces for a sandstone, a shale, and three granites. The experimental design approximated that employed in the Wilhelmy plate method. Replicate fracture faces were prepared by fracturing cylindrical rock cores using the Brazilian method and splitting the fractured cores apart along their fracture planes. Meniscus onset was imaged from a cross-sectional perspective using dynamic neutron radiography, and quantified with change point analysis. An existing model for meniscus onset fitted the experimental data very well (median R 2 = 0.96). Capillary rise was typified by t 2/3 scaling (where t is time), followed by a constant equilibrium height, z e . The average time taken for the menisci to reach z e was 0.39 s, with no differences between rock types. The menisci achieved a greater vertical extent on the fracture faces of the sedimentary rocks as compared to those of the granites. Apparent θ e values were calculated from the best fit estimates of z e using the Wilhelmy plate equation for a smooth and planar vertical surface. Despite the fractal roughness of some of the fracture faces, there was a significant linear relationship (R 2 = 0.80) between the apparent θ e values and intrinsic θ e values measured on polished surfaces of the same rocks using the sessile drop method. The regression equation indicated the apparent θ e values were consistently greater than the intrinsic values. This overestimation may be due to averaging of pixels at the air-water-solid interface, a required step in the image analysis. Further exploration of the range of applicability and measurement accuracy of this proposed new technique would be valuable.

58 GEOSCIENCES↗

Extracting Natural Biosurfactants from Humus Deposits for Subsurface Engineering Applications

Environmentally benign, economical, and effective surfactants and additives are needed in engineering subsurface energy recovery processes. Biosurfactants have some advantages over chemically synthesized surfactants, but the high costs of microbial-biosynthesis limit their applications in subsurface engineering. In this work, we propose to use naturally occurring biosurfactants contained within Earth's readily available and inexpensive humus deposits for subsurface engineering applications. We collected humus samples of different types from four different regions, and developed a simple method for extracting natural biosurfactant (NBS) using only four common chemicals. The average NBS extraction yields are 16 ± 3% of the raw humus. No significant differences in elemental composition and functional group chemistry were found among the NBS extracted from humus of different origins, suggesting that any humus deposit can be used for NBS extraction. Measurements of interfacial tensions between air-water and supercritical (sc) CO 2 -water interfaces indicate that the NBS is a highly effective surfactant. NBS has good foaming ability. Preliminary tests with only 0.5 mass % NBS in the aqueous phase (no other additives) yielded scCO 2 -in-water foams of 83% foam quality. The apparent viscosity of 13 cP measured at a shear rate of 2320 s -1 indicates that much higher viscosities are achievable at lower shear rates. Finally, these results suggest that NBS merits further research and development for potential applications in subsurface energy production.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Synchrotron X-ray microtomography and interfacial partitioning tracer test measurements of NAPL-water interfacial areas

Interfacial areas between an immiscible organic liquid (NAPL), and water were measured for two natural porous media using two methods, aqueous-phase interfacial partitioning tracer tests and synchrotron X-ray microtomography. The interfacial areas measured with the tracer tests were similar to previously reported values obtained with the method. The values were, however, significantly larger than those obtained from microtomography. Analysis of microtomography data collected before and after introduction of the interfacial tracer solution indicated that the surfactant tracer had minimal impact on fluid-phase configuration and interfacial areas under conditions associated with typical laboratory application. The disparity between the tracer test and microtomography values is attributed primarily to the inability of the microtomography method to resolve interfacial area associated with microscopic surface heterogeneity. This hypothesis is consistent with results recently reported for a comparison of microtomographic analysis and interfacial tracer tests conducted for an air-water system. The tracer test method provides a measure of effective, total (capillary and film) interfacial area, whereas microtomography can be used to determine separately both capillary-associated and film-associated interfacial areas. Both methods appear to provide useful information for given applications. A key to their effective use is recognizing the specific nature of the information provided by each, as well as associated limitations.

54 ENVIRONMENTAL SCIENCES↗

Near infrared leaf reflectance modeling

Near infrared leaf reflectance modeling using Fresnel's equation (Kumar and Silva, 1973) and Snell's Law successfully approximated the spectral curve for a 0.25-mm turgid oak leaf lying on a Halon background. Calculations were made for ten interfaces, air-wax, wax-cellulose, cellulose-water, cellulose-air, air-water, and their inverses. A water path of 0.5 mm yielded acceptable results, and it was found that assignment of more weight to those interfaces involving air versus water or cellulose, and less to those involving wax, decreased the standard deviation of the error for all wavelengths. Data suggest that the air-cell interface is not the only important contributor to the overall reflectance of a leaf. Results also argue against the assertion that the near infrared plateau is a function of cell structure within the leaf.

Parrish, J. B.↗

Boundary layer flow of air over water on a flat plate

A non-similar boundary layer theory for air blowing over a water layer on a flat plate is formulated and studied as a two-fluid problem in which the position of the interface is unknown. The problem is considered at large Reynolds number (based on x), away from the leading edge. A simple non-similar analytic solution of the problem is derived for which the interface height is proportional to x(sub 1/4) and the water and air flow satisfy the Blasius boundary layer equations, with a linear profile in the water and a Blasius profile in the air. Numerical studies of the initial value problem suggests that this asymptotic, non-similar air-water boundary layer solution is a global attractor for all initial conditions.

Nelson, John↗